My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10179443_3102 S. BAKER - Plan (2)
PBA
>
Building
>
Plans
>
B
>
Baker St
>
3102 S Baker St
>
10179443_3102 S. BAKER - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2022 12:03:24 AM
Creation date
10/25/2020 9:44:15 PM
Metadata
Fields
Template:
Plan
Permit Number
10179443
Full Address
3102 S Baker St
Fully Linked
True
Document Relationships
10179443 - Permit
(Permit - Plan)
Path:
\Building\Permits\B\Baker St\3102 S Baker St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SOLARMOUNT Technical Datasheets :1: UNI RAC <br />A 1111.Ti GROUPCOMPANY <br />SolarMount Beam Connection Hardware <br />SolarMount L-Foot <br />Part No. 304000C, 304000D <br />L-Foot <br />rrated <br />Flange Nu <br />Y <br />L-Foot material: One of the following extruded aluminum alloys: 6005- <br />T5, 6105-T5, 6061-T6 <br />Ultimate tensile: 38ksi, Yield: 35 ksi <br />Finish: Clear or Dark Anodized <br />L-Foot weight: varies based on height: -0.215 lbs (98g) <br />Allowable and design loads are valid when components are <br />assembled with SolarMount series beams according to authorized <br />UNIRAC documents <br />For the beam to L-Foot connection: <br />· Assemble with one ASTM F593 %"-16 hex head screw and one <br />ASTM F594 %"serrated flange nut <br />· Use anti-seize and tighten to 30 ft-lbs of torque <br />Resistance factors and safety factors are determined according to part <br />1 section 9 of the 2005 Aluminum Design Manual and third-party test <br />results from an IAS accredited laboratory <br />L.x <br />r E <br />1 1 <br />- 1 <br />- Aol <br />3X SLOT FOR . <br />4 MAA£*ARE + - <br />, <br />(1 1... , <br />Dimensions specified in inches unless noted <br />NOTE: Loads are given for the L-Foot to beam connection only; be <br />sure to check load limits for standoff, lag screw, or other <br />attachment method <br />Applied Load Average Safety Design Resistance <br />Direction Ultimate Allowable Load Factor,Load Factor, <br />lbs (N)lbs (N)FS lbs (N) ® <br />Sliding, Zi 1766 (7856)755 (3356)2.34 1141 (5077)0.646 <br />Tension, Y+1859 (8269)707 (3144)2.63 1069 (4755)0.575 <br />Compression, Y- 3258 (14492)1325 (5893)2.46 2004 (8913)0.615 <br />Traverse, Xi:486 (2162)213 (949)2.28 323 (1436)0.664 <br />0 <br />e
The URL can be used to link to this page
Your browser does not support the video tag.