Laserfiche WebLink
WIRE/CONDUIT SCHEDULE MODULE SPECIFICATION <br />TAG DESCRIPTION <br />1 ARRAY TO TRANSITION BOX <br />2 TRANSITION BOX TO INVERTER <br />3 INVERTER TO AC DISCONNECT <br />4 AC DISCONNECT TO MSP <br />5 BARE COPPER WIRE <br />6 EQUIPMENT GROUND <br />7 POWER TO MONITORING SYSTEM <br />8 INVERTER TO MONITORING SYSTEM <br />MONITORING SYS IEM 10 HOME NEIWORKING <br />9 <br />CONNECTION <br />CONDUIT <br />CONDUCTOR TYPE/SIZE <br />SIZE/TYPE <br />#10 AWG USE-2 N/A <br />#10 AWG THWN-2 i"EMT <br />#10 AWG THWN-2 *'EMT <br />#10 AWG THWN-2 1"EMT <br />#8 AWG SOLID N/A <br />#8 AWG THWN-2 t'EMT <br />#12 AWG THWN-2 *'EMT <br />#22 AWG COM.WIRE 1"EMT <br />UV RES. CAT IV CABLE N/A <br />NOTES MODEL NO.SPR-327NE-WHT-D <br />PEAK POWER 327W <br />FREE AIR RATED VOLTAGE (Vmp)54.7V <br />RATED CURRENT (Imp)5.98A <br />OPEN CIRCUIT VOLTAGE (Voc)64.9V <br />SHORT CIRCUIT CURRENT (Isc)6.46A <br />INVERTER SPECIFICATION <br />INVERTER MAKE POWER ONE <br />INVERTER MODEL PVI-5000-OUTD-US <br />MAX. DC VOLT RATING 600V <br />MAX. AC APPARENT POWER 5000W <br />NOMINAL AC VOLTAGE 240V <br />MAX AC CURRENT 23A <br />- -3 1 -1 GENERAL ELECTRICAL NOTES: <br />+1 <br />1. EQUIPMENT USED SHALL BE NEW, UNLESS OTHERWISE NOTED. <br />- 2. EQUIPMENT SHALL BE INSTALLED PROVIDING ADEQUATE PHYSICAL4 2 1 4 WORKING SPACE AROUND THE EQUIPMENT AND SHALL COMPLY WITH <br />NEC. <br />| 3. COPPER CONDUCTORS SHALL BE USED AND SHALL HAVE INSULATION <br />| ' RATING 600V, 90°C, UNLESS OTHERWISE NOTED. <br />. 4. CONDUCTORS SHALL BE SIZED IN ACCORDANCE TO NEC. <br />1-CONDUCTORS AMPACITY SHALL BE DE-RATED FOR TEMPERATURE 1 0 5. ALL CONDUCTORS, EXCEPT USE-2, SHALL BE INSTALLED IN APPROVEDINCREASE, CONDUIT FILL AND VOLTAGE DROP. <br />Ih CONDUITS OR RACEWAY. CONDUITS SHALL BE ADEQUATELY <br />SUPPORTED AS PER NEC. <br />6. RACKING AND MODULES ARE GROUNDED VIA A CONTINUOUS #10 AWG <br />COPPER CONDUCTOR, GROUNDING CLOPS, GROUNDING LUGS AND/OR <br />-BONDING JUMPERS.-11 7. LOAD SIDE INTER-CONNECTION SHALL COMPLY WITH NEC <br />8. SMOKE ALARM AND CARBON MONOXIDE DETECTORS SHALL BE <br />LOCATED AS REQD PER SEC. R314 & R315 OF THE CALIFORNIA <br />RESIDENTIAL CODE (CRC) <br />9. ALL EQUIPMENT SHALL BE LISTED FOR THE APPLICATION, UL 1703 FOR <br />MODULES. UL 1741 FOR INVERTERS <br />I <br />0 <br />0 <br />h <br />£ <br />ARRAY DETAILS <br />NO. OF MODULE PER STRING 5 <br />NO. OF STRINGS 3 <br />ARRAY WATTS AT STC 4.905kW <br />MAX. VOLTAGE 344.8V <br />UTILITY <br />Bl-DIRECTIONAL <br />ELECTRIC METER <br />EXISTING <br />MAIN SERVICE PANEL <br />125A, 240VAC, 1 PH, <br /> MCB <br />1 100A«D <br />J-BOX <br />NEMA 3R <br />DC INTERFACE POWER ONE PVI-5000-OUTD-US <br />INTEGRATED DC 5000W, 96.5% CEC <br />DISCONNECT 240VAC, 23A AC INTERFACE <br />AC DISCONNECT <br />240VAC, 30A Cih <br />NEMA 3R, UL LISTED 0/ <br />15A Ui <br />3Nll 31 MVhIDVI <br />1 <br />El- <br />/ MPPT 1 ---7- <br />lg MPPT 2 ./ .u <br />DC- <br /> MPPT 1 -1.,-l-6 MPPT 2 1 <br />Ll - <br />L2 <br />0 <br />30A <br />SMS <br />DATA <br />LOGGER <br />i <br />5 GND <br />N L2 Ll <br />EXISTING <br />GROUND <br />ETHERNET <br />CONNECTION <br />TO DSUCABLE <br />MODEM PV 3 <br />714-754-4331 <br />BREA, CA 92821 T: 714-676-8888