Laserfiche WebLink
REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />JE <br />F <br />F <br />R <br />E <br />Y <br /> <br />C <br />H <br />E <br />N <br />G <br />ANSI B <br />11" X 17" <br />DATEDESCRIPTION <br />REVISIONS <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-1 <br />CONTRACTOR NAME <br />CONTRACTOR INFORMATION <br />PH <br />O <br />N <br />E <br />: <br />- <br /> <br />+1 <br />4 <br />1 <br />5 <br />3 <br />6 <br />1 <br />0 <br />8 <br />4 <br />5 <br />27 <br />0 <br />9 <br /> <br />D <br />A <br />Y <br />N <br />A <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />AH <br />J <br />: <br />- <br /> <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />I <br />T <br />Y <br />CO <br />U <br />N <br />T <br />Y <br />: <br />- <br /> <br />(O <br />R <br />A <br />N <br />G <br />E <br /> <br />C <br />O <br />U <br />N <br />T <br />Y <br />) <br />SOLAR OPTIMUM <br />501 W. GLENOAKS BLVD #555 <br />GLENDALE, CA, 91202 <br />(818) 804-3122 <br />CALIFORNIA C-10 <br />LIC# 972228 <br />ARPIAR TARVERDI <br />COVER SHEET <br />SCOPE OF WORK <br />SYSTEM SIZE: 25 X 435 = 10.88KW <br />CEC AC: 9.92KW <br />MODULES: (25) MISSION SOLAR: MSX10-435HN0B 435W MODULES <br />MCI: (09) TESLA MCI-2 (240V) <br />MODULE MAX POWER (P/MAX): 435W <br />INVERTER: (01) TESLA POWERWALL 3 @ (240V) <br /> (01) TESLA POWERWALL 3 EXPANSION UNIT <br />RACKING: UNIRAC LIGHT RAIL <br />ATTACHMENT: UNIRAC FLASH LOC DUO <br />VICINITY MAP <br />GENERAL NOTES: <br />CODE SUMMARY <br />THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />2022 CALIFORNIA ENERGY CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2020 NATIONAL ELECTRICAL CODE <br />ALL OTHER ORDINANCES ADOPTED BY THE LOCAL <br />GOVERNING AGENCIES. <br />·LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. <br />·THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES <br />·PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED <br />·ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED <br />·ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703, UL1741 AND UL1703 <br />·ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS GeoCel 2300 CLEAR SEALANT <br />·THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED <br />·THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS <br />·IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE, IT IS THE NECESSARY TO INSTALL A <br />SUPPLEMENTAL GROUNDING ELECTRODE <br />·EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED ON THE <br />MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS" <br />·A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH CAL-OSHA REGULATIONS <br />·PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER, AND SYSTEM <br />COMPLIES WITH 690.35. <br />·MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. <br />·INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. <br />·ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED, LABELED, AND INSTALLED PER THE NEC, THE INSTALLATION <br />STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A RECOGNIZED ELECTRICAL TESTING LABORATORY. <br />·CONDUITS AND CABLES EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN 7/8" ABOVE ROOF SURFACE. NEC <br />310.15(B)(3)(c) <br />·THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITHSTAND A MINIMUM 110 MPH WIND LOAD. <br />BUILDING INFORMATION: 1 STORY HOUSE <br />TYPE OF CONSTRUCTION: V-B <br />OCCUPANCY: RESIDENTIAL GROUP R - 3 <br />ASSESSOR PARCEL: 39053211 <br />ROOF TYPE: COMPOSITE SHINGLE <br />ROOF RAFTERS: 2"X6" @ 24" O.C. <br />ELECTRICAL INFORMATION <br />UTILITY COMPANY: SCE (UNDERGROUND) <br />MAIN SERVICE AMPERAGE: 225A <br />ARRAY TILT:ARRAY AZIMUTH: <br />#1 - 22°#1 - 180° <br />#2 - 22°#2 - 90° <br />TABLE OF CONTENTS <br />PAGE #DESCRIPTION <br />PV 1 COVER SHEET <br />PV 2 SITE PLAN <br />PV 3 ARRAY DETAIL <br />PV 4 STRING LAYOUT <br />PV 5-6B ATTACHMENT DETAIL <br />PV 7 ELECTRICAL DIAGRAM <br />PV 8 ELECTRICAL CALCULATION <br />PV 9 PLACARD <br />PV 10+SPEC SHEETS