*,,SANTA <br />NA <br />ILI\]IIG <br />iIUut\[ <br />IfiIfi <br />Planning & Building Agency <br />Building Safety Division <br />20 Civic Center Plaza <br />P.O. Box 1988 (M-'19) <br />Santa Ana, CA 92702 <br />(714) 647-s800 <br />www.santa-ana.or9 <br />RESIDENT!AL <br />PHOTOVOLTAIC <br />CHECKLIST <br />sol-o1 cBc 2013 <br />Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Onty <br />lnstructions: The licensed contraclor of record shall complete all sections, answer the ten questions and <br />sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of <br />minimum 11" x 17" size. lf answerino NO t o anv of the ouestions. o lan check shall be required. <br />Project Address:V1a6"\-r <br />Contractor Company Name:t-!o ta-Ll o LLC <br />contractor License Number, llll f L, <br />YES NO Are the following applicable to the proposed project? <br />Will the PV system layout provide the required three-foot wide clear access pathways <br />per Section 605.11 of the California Fire Code, and is this shown on the roof plan? <br />Will the PV system be installed on a rool having only one roofing layer with no <br />overlays? <br />Will the PV array be flush mounted to the exasting roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 4 pounds per square feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2" minimum to 10" maximum between <br />the underside of modules and the surface of the roof? <br />Will the PV system be installed without using any ballast system or counter-weight <br />system? <br />Will the anchors be installed with a maximum horizontal ancho[ spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed with a minimum ot 2-112inch <br />embedment into roof rafters (with pre-drilled holes) and is this minimum embedment <br />shown on the plans? <br />Are ALL the struclural pages ofthe plans stamped and signed by a California <br />licensed professional engineer? (including prolect speciflc site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's PV support information.) <br />(u <br />2 ETE <br />3 Ertr <br />4va <br />5. EI-tr <br />6 Ertr <br />7 EItr <br />8 EI-tr <br />9 EItr <br />10 qc <br />I certity underlp <br />Print Name: L <br />e na lty of perjury under the laws of th <br />L'l^/V <br />e State of Cali iat h[f,7!.o'" i..,u.' <br />Signature <br />Phone Number:67'L q +l)1 o Date <br />Email Address: fi)etnt t <br />Rev: 11/'19/2015 <br />Ur*o la,r.u *'t <br />+ri <br />1.