Laserfiche WebLink
,,-SANTA <br />NA <br />IIT$IM <br />lilI'F{ <br />lmil <br />Planning & Building AgencY <br />Euitding Satety Division <br />20 Civic C.rter Plr:t <br />P.O. Bt x ,988 (Mlg) <br />Santa Ana" CA 92702 <br />(71a) 6/r7-5t0o <br />www.santa-ana.org <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />CHECKL]ST <br />soL41 CBC 2013 <br />SolarPhotovoltaic(PV)ChecklistforDetachedSlNGLEFAMlLYRESlDENCESonly <br />lnstructions: The licensed contractor of record shall compl ete all 6ection6, ans:wer the ten questions and <br />srgn the certiMiol sectixt bdow. A copy 0f this foflr shaH be attached to each d TWO sets of ptans' of <br />minimum 11 x 17 s ize. lf an rinq NO t o anv ot lhe ouestions,Dlan check shall be req uired. <br />2021 West Wilshire Ave., Santa Ana, CA 927MProiect Address: <br />Contractor ComPanY Name: <br />Contractor Licefl se Number: <br />2 Etr <br />trD <br />4 EE <br />5 EIEI <br />Complete Solar <br />YES NOtrtr <br />951988 <br />Are the following applic.Uc to ttB p3opo€Gd proi6ct? <br />Will the PV system layout provide the required three-foot wide clear access pathways <br />per Section 505.1 1 of the California Flre Code, and is this shown on lhe rcot plan? <br />Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />!1/ill the PV array be flush mounted to lhe existing roof so that the plane of the <br />modules (panels) are paratlel to the plane of the roof? <br />Witl the PV system weigh maximum 4 pounds per square feel or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Wll th€ PV system b€ install€d with a srElfp of 2 rninimum to 10 maximum between <br />the understde of modules and the $rrface of the roof? <br />Wll the PV system be installed without using any ballast system or counter-weight <br />system? <br />will the anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />vYill the n{nimum 5/16 hg screws be installed with a minimum ot 21n nch <br />emb€drnent into roof rafteE (with pre-drilled holes) and is this minimum embedment <br />shown on fie dans? <br />Are ALL the structural pages of the plans WET stamped and signed by a Califomia <br />{icensed pro{essional engineer? (including prqect specific site plan, PV layout, <br />,n"i'orrj" spacing, ancfiorage d;tails and manufacturer s PV support information ) <br />6 <br />7 <br />Etr <br />Etr <br />8 trtr <br />I Eltr <br />10 trtr <br />lcertifyunderp€naltyofperjuryunderthelawsofthestateofcallfomiathattheaboveistrue: <br />Print Name: Steve Galindo S€nan re <br />Phone Number <br />Email Address: <br />Rev: &1712015 <br />650 - 704-402l Date: 04l17l18