My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10179612_1631 S. SPRUCE - Plan (2)
PBA
>
Building
>
Plans
>
S
>
Spruce St
>
1631 S Spruce St
>
10179612_1631 S. SPRUCE - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2021 11:54:10 PM
Creation date
10/25/2020 9:44:53 PM
Metadata
Fields
Template:
Plan
Permit Number
10179612
Full Address
1631 S Spruce St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PLAQUES AND LABELING <br />PV MODULE RATINGS @ STC (Guide Section 5) <br />MODULE MAKE SUNPOWER <br />MODULE MODEL SPR-X20-250-BLK-D <br />MAX POWER-POINT CURRENT (Ip,p)5.84 A <br />MAX POWER-POINT VOLTAGE (VMp)42.8 v <br />OPEN-CIRCUIT VOLTAGE (Voc)50.9 v <br />SHORT-CIRCUIT CURRENT ('sc)6.20 A <br />MAX SERIES FUSE (OCPD) 2 A <br />MAXIMUM POWER (MAX 250 w <br />MAD< VOLTAGE (TYP 600Vc)600 v <br />VOC TEMP COEFF (mv/°C[aor °/0/°co -125.6 <br />IF COEFF SUPPLIED, CIRCLE UNITS <br />Label for DC conduit and j-boxes <br />CAUTION: DC SOLAR CIRCUIT <br />NOTES FOR ALL DRAWINGS: <br />OCPD = OVERCURRENT PROTECTION DEVICE <br />NATIONAL ELECTRICAL CODE® REFERENCES <br />SHOWN AS (NEC)00<.XX) <br />INVERTER RATINGS (Guide Section 41 <br />INVERTER MAKE POWER-ONE <br />INVERTER MO[)EL PVI-3.0-OUTD-S-US (240V) <br />MAX DC VOLT RATING 600 v <br />MAX POWER @ 40°C 3000 w <br />NOMINAL AC VOLTAGE 211 -264 v <br />M AX AC CURRENT 14.5 A <br />MAX OCPD RATING 20 A <br />SIGNS-SEE GUIDE SECTION 7 <br />SIGN FOR DC DISCONNECTWORST CASE <br />PHOTOVOLTAIC POWER SOURCE <br />RATED MPP CURRENT 5.84 A <br />RATED MPP VOLTAGE 257 v <br />MAX SYSTEM VOLTAGE 342 v <br />MAX CIRCUIT CURRENT 7.75 A <br />WARNING: ELECTRICAL SHOCK <br />HAZARD-LINE AND LOAD MAY BE <br />ENERGIZED IN OPEN POSITION <br />SIGN FOR INVERTER OCPD AND <br />AC DISCONNECT (IF USED) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />AC OUTPUT CURRENT 14.5 A <br />NOMINAL AC VOGAGE 240 v <br />THIS PANEL FED BY MULTIPLE <br />SOURCES (UTILITY AND SOLAR) <br />NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D):NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): <br />1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN <br />EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP -4 °C <br />2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST <br />MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE 44 °C <br />1) IF UTILITY REQUIRES A VISIBLE-BREAILSWITCH, DOES THIS SWITCH MEET THE <br />REQUIREMENT? YES[ZI No 14/ALI <br />2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE <br />REQUIREMENT? YES 0 NO ¤ N/A ¤ <br />3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX <br />2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED <br />47°C IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1°C). FOR LESS THAN 9 <br />CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT <br />LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF <br />47°C OR LESS (ALL OF UNITED STATES), <br />CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT <br />4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER <br />OCPD AMPERE RATING. (See Guide Section 9) <br />5) TOTAL OF 1 INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL <br />a) 12 AWG, 90°C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER <br />FUSE. <br />b) 10 AWG, 90°C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER <br />FUSE. <br />SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? <br />YES 171 NO[1 <br />Contractor Name,Notes for One-Line Standard Electrical <br />Address and Phone: <br />SUNPRO SOLAR Diagram for Single-Phase PV Systems <br />34859 FREDRICK ST. 101 Site Name: Jimmv Stephan1. RATED MPP CIJRRENT: 5.84A( Imp) x 1(Strings)(Worst Case) = 5.84A WILDOMAR, CA. 92595 Site Address: 1631 S Spruce Street, Santa Ana, CA 92704951-678-7733 <br />2. RATED MPP VOLTAGE: 42.8V(Vmp) x 6(Modules) = 256.8V (257V)System AC Size: 2.641<Wac <br />SIZE FSCM NO DWG NO REDrawn By: Bob Kornmann El.23. MAX SYSTEM VOLTAGE: <br />50.9V(Voc) x 1.12(Temp Correction) x 6(Modules) = 342.05V (342V)Checked By:2//1.»94 SCALE NTS Date: 8/27/13 SHEET <br />4. MAX CIRCUIT CURRENT: 6.20A(Isc) x 1(Strings)(Worst Case) x 125% = 7.75A
The URL can be used to link to this page
Your browser does not support the video tag.