My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10179612_1631 S. SPRUCE - Plan (2)
PBA
>
Building
>
Plans
>
S
>
Spruce St
>
1631 S Spruce St
>
10179612_1631 S. SPRUCE - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2021 11:54:10 PM
Creation date
10/25/2020 9:44:53 PM
Metadata
Fields
Template:
Plan
Permit Number
10179612
Full Address
1631 S Spruce St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
NOTES:£-6 L *(301,3 <br />1. All exposed photovoltaic system conductors on the roof will be USE-2 or PV wire. <br />2. All photovoltaic system conductors will be 90 degree C rated in accordance with CEC 690.31B, Table 310.16, Table 310.17. <br />3. Where DC conductors are run inside the building or attic, they shall be contained in a metal raceway in accordance with CEC 690.31 E. <br />4. All exterior conduit, fittings and boxes shall be rain-tight and approved for use in wet locations in accordance with CEC 314.15. <br />5. All conductors exposed to sunlight shall be listed as sunlight resistant in accordance with CEC 300.6 Cl, 310.8 D. <br />6. All photovoltaic output circuits operating above 30 volts shall be installed in readily accessible location and in electrical raceways in accordance <br />with CEC 690.31. <br />7. All metallic raceways and equipment shall be bonded and electrically continuous in accordance with CEC 250.90,250.96. <br />8. The photovoltaic arrays shall be provided with DC ground-fault protection in accordance with CEC 690.5. <br />9. The DC grounding electrode conductor shall be sized according to CEC 250.166,690.47B <br />10. The DC grounding electrode shall be bonded to the AC grounding electrode and the conductor shall be no smaller than the largest grounding <br />electrode conductor, either AC or DC CEC 690.47 C 7. <br />11. The AC grounding electrode conductor shall be sized according to NEC 250.66, Table 310.15 B 6, CEC 690.47. <br />12. Grounding bushings are required around pre-punched concentric knock outs on the DC side ofthe system. CEC 250.97 <br />13. The grounding electrode to be protected from physical damage between the grounding electrode and the panel or inverter if smaller than #6 <br />copper wire in accordance with CEC 250.64B. <br />14. Grounding electrode conductor will be continuous, except for splices or joints at bus bars within listed equipment in accordance with CEC 250.64 C. <br />15. If a water pipe is use for the grounding an additional driven rod ufer ground will be installed in accordance with CEC 250.50. <br />16. PV backfed breaker to be installed on the opposite end of the bus bar from the main breaker and labeled " WARNING- PHOTOVOLTAIC <br />CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE". <br />17. City Building Inspector shall inspect accessible structural connections and the house current side ofthe system, all other equipment shall be UL listed and approved. <br />18. A smoke detector, approved and listed by the State Fire Marshall, shall be installed in each dwelling when a permit for alterations, repairs or additions exceed $1,000.00. <br />A battery powered smoke detector satisfies the requirements for a smoke detector. (907.2.10.2 CBC) <br />19. Approved combined smoke alarms and carbon dioxide alarms shall be acceptable. <br />20. A carbon monoxide detector shall be installed in the specific existing dwelling unit that have attached garages or fuel-burning appliances for which a permit is issued for alterations, repairs <br />or additions exceeding $1,000.00. Listed single-or multi-station carbon monoxide alarms may be used. The alarm shall receive its primary power from the building wiring except it is permitted <br />to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of an attic. (R.315 CRC) <br />.
The URL can be used to link to this page
Your browser does not support the video tag.