Laserfiche WebLink
Page # 5 <br />CALCULATION OF DESIGN WIND LOADS <br />Wind Design Criteria <br />Wind Design Code ASCE 7-05 <br />Wind Design Method Partially/Fully Enclosed Method <br />Basic Wind Speed V 85 mph Fig. 6-1 <br />Exposure Category C Section 6.5.6.3 <br />Roof Style Gable/Hip Roof Fig. 6-11B/C/D-14A/B <br />Mean Roof Height h 15 ft Section.6.2 <br />Effective Roof Slope 20° <br />Effedive Rafter Spacing 24" O.C. <br />Effective Wind Area (1 Module) A 17.6 sf IBC 1509.7.1 <br />Wind Pressure Calculation Coefficients <br />Wind Pressure Exposure Kz <br />Topographic Factor 16 <br />Wind Directionality Factor Kd <br />Importance Factor I <br />Velocity Pressure q <br />0.85 <br />1.00 <br />0.85 <br />1.0 <br />qh = 0.00256 (Kz) (Kzt) (Kd) (VA2) (I) <br />13.3 psf <br />Table 6-3 <br />Section 6.5.7 <br />Table 6-4 <br />Table 6-1 <br />Equation 6-15 <br />Wind Pressure <br />Ext. Pressure Coefficient (Up)-0.88 Fig. 6-11B/C/D-14A/BGCp <up) <br />Ext. Pressure Coefficient (Down)GCM (Down)0.45 Fig. 6-11B/C/D-14A/B <br />Design Wind Pressure p p=Clt (GCD)Equation 6-22 <br />Wind Pressure Up P(UP)-11.7 psf <br />Wind Pressure Down P(down)10.0 psf <br />ALLOWABLE STANDOFF SPACINGS <br />X-Direction Y-Direction <br />Max Allowable Standoff Spacing Landscape 72"39" <br />Max Allowable Cantilever -Landscape 24"7- NA T <br />Standoff Configuration Landscape Not-Staggered <br />Max Standoff Tributary Area Trib 19 sf <br />PV Assembly Dead Load W-PV 3 psf <br />N* Wind Uplift_at Standoff T-actual -195 lbs <br />Uplift Capacity of Standoff T-allow 637 lbs <br />Standoff Demand/Capacity DCR 30.6%