My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1108 3%4 N Harbor Blvd Unit# WCC03 - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Harbor Blvd
>
1108 3/4 N Harbor Blvd Unit# WCC03
>
1108 3%4 N Harbor Blvd Unit# WCC03 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2025 5:00:07 AM
Creation date
12/17/2025 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
101125309
Full Address
1108 3/4 N Harbor Blvd Unit# WCC03
Street Number
1108
Partial
3/4
Street Direction
N
Street Name
Harbor
Street Suffix
Blvd
Unit Number
WCC03
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Eukon <br />www.eukongroup.com <br />65 POST, SUITE 1000 <br />IRVINE, CA 92618 <br />TEL: (949) 553-8566 <br />an SFC Communications, Inc. Company <br />CLL01585 <br />1108 N. HARBOR BLVD. <br />SANTA ANA, CA 92703 <br />REV DATE DESCRIPTION <br />SUBMITTALS <br />A 04/12/25 90% CONSTRUCTION DRAWINGS <br />PROJECT INFORMATION <br />SHEET TITLE <br />SHEET NUMBER <br />DRAWN BY: <br />MG --FE <br />CONSTRUCTION <br />DRAWINGS <br />IT IS A VIOLATION OF LAW FOR ANY PERSON, <br />UNLESS THEY ARE ACTING UNDER THE DIRECTION <br />OF THE LICENSED PROFESSIONAL ENGINEER, <br />TO ALTER THIS DOCUMENT. <br />UTILITIES <br />CHECKED BY: <br />A&E <br /> CHECKED BY: <br />1452 EDINGER AVE. <br />3RD FLOOR <br />TUSTIN, CA 92780 <br />NOT <br /> <br />F <br />O <br />R <br />CON <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br />GN-2 <br />Exp. 3/31/24 <br />No E-19043REGISTEREDPROFESSIONALENGINEER <br />TLECE IRC LAS <br />ROFETAT <br />O FILAC <br />AIN <br />J <br />REMA <br />DS UMMOND <br />EU <br />K <br />O <br />N <br />_ <br />A <br />T <br />& <br />T <br />_ <br />7 <br />5 <br />C <br />D <br />_ <br />M <br />O <br />N <br />O <br />P <br />O <br />L <br />E <br /> <br />T <br />E <br />M <br />P <br />L <br />A <br />T <br />E <br />_ <br />V <br />2 <br />_ <br />1 <br />1 <br />- <br />1 <br />8 <br />- <br />2 <br />2 <br />0 06/27/25 100% CONSTRUCTION DRAWINGS <br />GROUNDING DETAILS <br />NOT USED <br />NOT USED <br />NOT USED <br />CABLE GND. KIT TO ANT. <br />NOT USED <br />NOT USED <br />NOT USED <br />GND. WIRE TO GND. BAR <br />EXOTHERMIC WELD <br />NOT USED <br />GROUND BAR DETAIL <br />MECHANICAL CONNECTION <br />GROUNDING NOTES <br />GND. WIRE TO GRD. BAR <br />SCALE <br />NONE 1 <br />SCALE <br />NONE 2 <br />SCALE <br />NONE 4 <br />SCALE <br />NONE 5 <br />SCALE <br />NONE 7 <br />SCALE <br />NONE 8 <br />SCALE <br />NONE 9 <br />SCALE <br />NONE 10 <br />SCALE <br />NONE 11 <br />SCALE <br />NONE 12 <br />SCALE <br />NONE 13 <br />SCALE <br />NONE 14 <br />SCALE <br />NONE 15 <br />SCALE <br />NONE 16 <br />2. <br />3. <br />1.DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND <br />WIRE DOWN TO GROUND BAR. <br />GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR <br />RECOMMENDED BY CABLE MANUFACTURER. <br />WEATHER PROOFING SHALL BE (TYPE AND PART NUMBER AS SUPPLIED <br />OR RECOMMENDED BY CABLE MANUFACTURER.) <br />2 <br />1 <br />1 <br />/ <br />1 <br />6 <br />" <br /> <br />D <br />I <br />A <br />. <br /> <br />M <br />A <br />X <br />. <br />12" TO 24" <br />NOTES: <br />1. <br />2. <br />ANTENNA CABLE TO BTS <br />EQUIPMENT (TYP) <br />ANDREW SUREGROUND <br />TYPE GROUND KIT <br />(TYPICAL) <br />(SEE NOTE) <br />WEATHERPROOFING <br />KIT (TYP.) <br />ANTENNA GROUND BAR, <br />SIMILAR TO DETAIL 3 <br />WITHOUT INSULATORS. <br />BONDED DIRECTLY TO <br />TOP OF POLE OR <br />TOWER. <br />TX1 <br />CONNECTOR <br />WEATHERPROOFING <br />KIT (TYP.) <br />SEE NOTE 2 <br />COAX JUMPER (TYP.) <br />#6 AWG <br />TO ANTENNAS <br />DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT <br />GROUND WIRE DOWN TO ANTENNA GROUND BAR. <br />WEATHER PROOFING SHALL BE ANDREW TWO-PART TAPE KIT, COLD <br />SHRINK SHALL NOT BE USED. <br />RX1 <br />TWO HOLE LONG BARREL LUG. TO <br />BE USED WITH # 2 AWG CU <br />STRANDED WIRE WITH GREEN, 600V <br />THWN INSULATION TO BTS CABINET. <br />USE STAINLESS STEEL HARDWARE. <br />#6 AWG STRANDED CU WIRE WITH <br />GREEN, 600V, THWN INSULATION <br />(AS REQUIRED) <br />- <br />8 <br />NOTES: <br />1 <br />1- UNIVERSAL TINNED COPPER BUSS BAR <br />WITH HARDWARE: <br />BY ANDREW CORPORATION <br />UGBKIT-0420-T : 1/4"x4"x20" (SHOWN) <br />UGBKIT-0412-T : 1/4"x4"x12" <br />UGBKIT-0210-T : 1/4"x2"x10" <br />GB-HKU : MOUNTING HARDWARE KIT <br />2-ANDREW #MTC9674KEY TAMPER RESISTANT <br />BUSS BAR BOLT KIT <br />2 <br />NOTE: <br />HOLE CENTERS TO MATCH NEMA <br />DOUBLE LUG CONFIGURATION. <br />NOTES <br />1.NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA <br />LOCATION, AND CONNECTION ORIENTATION, THE SUBCONTRACTOR SHALL BE RESPONSIBLE <br />FOR INSTALLING ADDITIONAL GROUNDING BAR AS REQUIRED, PROVIDING 50% SPARE <br />CONNECTION POINTS. <br />2.DO NOT INSTALL CABLE GROUNDING KIT AT A BEND AND ALWAYS DIRECT GROUNDING <br />CONDUCTOR DOWN TO GROUNDING BAR. <br />3.GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY <br />CABLE MANUFACTURER. <br />4.WEATHER PROOFING SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY <br />CABLE MANUFACTURER. <br />5.PROVIDE GROUNDING KIT 6” BEFORE TURN TRANSITION FROM TOWER TO ICE BRIDGE. <br />6.WHEN THE SCOPE OF WORK REQUIRES THE ADDITION OF A GROUNDING BAR TO AN EXISTING <br />TOWER, THE SUBCONTRACTOR SHALL OBTAIN APPROVAL FROM THE TOWER OWNER PRIOR <br />TO MOUNTING THE GROUNDING BARS TO THE TOWER. <br />7.EXTEND TWO (2) #2 AWG TINNED CU CONDUCTOR FROM BURIED GROUNDING RING AND <br />CONNECT TO THE PROPOSED TOWER, FOLLOW MANUFACTURERS RECOMMENDATIONS FOR <br />GROUNDING CONNECTIONS TO THE TOWER. (APPLICABLE TO NEW TOWERS ONLY.) <br />8.BUILDINGS AND/OR NEW TOWERS GREATER THAN 75 FEET IN HEIGHT AND THE MAIN <br />GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR <br />SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOF-TOP, TOWERS, AND WATER <br />TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING <br />CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 AWG COPPER, ROOF-TOP GROUNDING RING <br />SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, <br />LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR <br />NONFERROUS METAL PIPING ONLY), SEE AT&T GROUNDING AND BONDING STANDARDS <br />TP—76416 SPECIFICATION 6.5.2.2. <br />9.FLEX CONDUIT TO BE INSTALLED ON PROPOSED COPPER CONDUCTOR UP TO GROUNDING <br />BAR AND, SEALED AT ENDS TO PROTECT FROM OUTSIDE MOISTURE AND DEBRIS. <br />NEW EQUIPMENT <br />GROUND BAR#6 SWG STRANDED COPPER <br />GROUND WIRE <br />(GROUNDED TO GROUND BAR) <br />(SEE NOTE 1 & 2) <br />CABLE GROUND KIT <br />WEATHERPROOFING KIT <br />(SEE NOTE 3) <br />ANTENNA CABLE <br />1 BOLT <br />PARALLEL <br />CLAMP <br />CAST ``T'' <br />SPLICER <br />2 HOLE LUG <br />``U'' BOLT <br />PIPE CLAMP <br />1 BOLT <br />PARALLEL <br />CLAMP <br />UNIVERSAL <br />PIPE <br />CLAMPS <br />50H2 <br />CROSS RUN <br />CLAMP UNIVERSAL <br />PIPE <br />CLAMPS <br />75/1.25 <br />2 BOLT <br />PARALLEL <br />SPLICER <br />BOLT GRND. <br />ROD CLAMP <br />TYPE RRTYPE PCTYPE GL LUGTYPE GRTYPE XA <br />TYPE LJ TYPE HA TYPE VS TYPE NX1 TYPE ND <br />TYPE NCTYPE GYTYPE GTTYPE PG <br />TYPE SS TYPE TA TYPE VB TYPE PH TYPE GR <br />NOT <br /> <br />F <br />O <br />R <br />CON <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br />NOT <br /> <br />F <br />O <br />R <br />CON <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br />NOT <br /> <br />F <br />O <br />R <br />CON <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br />NOT <br /> <br />F <br />O <br />R <br />CON <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N
The URL can be used to link to this page
Your browser does not support the video tag.