<br />REV DATE DESCRIPTION
<br />SUBMITTALS
<br />A 04/12/25 90% CONSTRUCTION DRAWINGS
<br />PROJECT INFORMATION
<br />SHEET TITLE
<br />SHEET NUMBER
<br />DRAWN BY:
<br />MG --FE
<br />CONSTRUCTION
<br />DRAWINGS
<br />IT IS A VIOLATION OF LAW FOR ANY PERSON,
<br />UNLESS THEY ARE ACTING UNDER THE DIRECTION
<br />OF THE LICENSED PROFESSIONAL ENGINEER,
<br />TO ALTER THIS DOCUMENT.
<br />UTILITIES
<br />CHECKED BY:
<br />A&E
<br /> CHECKED BY:
<br />1452 EDINGER AVE.
<br />3RD FLOOR
<br />TUSTIN, CA 92780
<br />NOT
<br />
<br />F
<br />O
<br />R
<br />CON
<br />S
<br />T
<br />R
<br />U
<br />C
<br />T
<br />I
<br />O
<br />N
<br />T-2
<br />EU
<br />K
<br />O
<br />N
<br />_
<br />A
<br />T
<br />&
<br />T
<br />_
<br />7
<br />5
<br />C
<br />D
<br />_
<br />M
<br />O
<br />N
<br />O
<br />P
<br />O
<br />L
<br />E
<br />
<br />T
<br />E
<br />M
<br />P
<br />L
<br />A
<br />T
<br />E
<br />_
<br />V
<br />2
<br />_
<br />1
<br />1
<br />-
<br />1
<br />8
<br />-
<br />2
<br />2
<br />0 06/27/25 100% CONSTRUCTION DRAWINGS
<br />ABBREVIATIONS
<br />GENERAL NOTES,
<br />LEGEND, AND
<br />ABBREVIATIONS
<br />GENERAL NOTES 15
<br />1.THE FACILITY IS AN UNOCCUPIED DIGITAL TELECOMMUNICATION FACILITY.
<br />2.PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED
<br />OTHERWISE. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR
<br />NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.
<br />3.PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS SHALL VISIT THE JOB SITE AND BE RESPONSIBLE
<br />FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS, AND CONFIRMING THAT THE WORK
<br />MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES ARE
<br />TO BE BROUGHT TO THE ATTENTION OF THE IMPLEMENTATION ENGINEER AND ENGINEER PRIOR TO
<br />PROCEEDING WITH THE WORK.
<br />4.THE CONTRACTOR SHALL OBTAIN, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON
<br />ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS.
<br />5.THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S
<br />RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE OR WHERE LOCAL CODES OR
<br />REGULATIONS TAKE PRECEDENCE.
<br />6.ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE
<br />CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL
<br />LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING
<br />THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN
<br />ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND
<br />STATE JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS.
<br />7.THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE BEST SKILLS AND
<br />ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS,
<br />TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK
<br />UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE IMPLEMENTATION ENGINEER
<br />AND WITH THE LANDLORD'S AUTHORIZED REPRESENTATIVE.
<br />8.SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH U.L. LISTED AND FIRE CODE APPROVED MATERIALS.
<br />9.PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75
<br />FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA DURING CONSTRUCTION.
<br />10.DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO
<br />SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE
<br />WORK.
<br />11.REPRESENTATIONS OF TRUE NORTH, OTHER THAN THOSE FOUND ON THE PLOT OF SURVEY DRAWING
<br />(SHEET LS1 OR SHEET C-1), SHALL NOT BE USED TO IDENTIFY OR ESTABLISH THE BEARING OF TRUE NORTH
<br />AT THE SITE. THE CONTRACTOR SHALL RELY SOLELY ON THE PLOT OF SURVEY DRAWING AND ANY
<br />SURVEYOR'S MARKINGS AT THE SITE FOR THE ESTABLISHMENT OF TRUE NORTH, AND SHALL NOTIFY THE
<br />ENGINEER PRIOR TO PROCEEDING WITH THE WORK IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS
<br />ELEMENTS OF THE WORKING DRAWINGS AND THE TRUE NORTH ORIENTATION AS DEPICTED ON THE CIVIL
<br />SURVEY. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO NOTIFY THE ENGINEER.
<br />12.THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, PAVING,
<br />CURBS, VEGETATION, GALVANIZED SURFACES, ETC., AND UPON COMPLETION OF WORK REPAIR ANY DAMAGE
<br />THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF AT&T.
<br />13.KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH AND REMOVE
<br />EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN CONDITION AND
<br />FREE FROM PAINT SPOTS, DUST OR SMUDGES OF ANY NATURE.
<br />14.PENETRATIONS OF ROOF MEMBRANES SHALL BE PATCHED/FLASHED AND MADE WATERTIGHT USING LIKE
<br />MATERIALS IN ACCORDANCE WITH NRCA ROOFING STANDARDS AND DETAILS. CONTRACTOR SHALL OBTAIN
<br />DETAILING CLARIFICATION FOR SITE-SPECIFIC CONDITIONS FROM ENGINEER, IF NECESSARY, BEFORE
<br />PROCEEDING.
<br />15.BEFORE ORDERING AND/OR BEFORE FABRICATING/CONSTRUCTING/INSTALLING ANY ITEMS, VERIFY THE
<br />TYPES AND QUANTITIES.
<br />16.CONTRACTOR SHALL PROVIDE SITE FOREMAN WITH A CELLULAR PHONE AND PAGER, AND KEEP SAME ON
<br />SITE WHENEVER PERSONNEL ARE ON SITE.
<br />17.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON THE SITE AND NOTIFY THE PROJECT
<br />MANAGER OF ANY DISCREPANCIES BEFORE STARTING ANY WORK.
<br />18.CONTRACTOR TO PROVIDE COMPLETE SET OF AS BUILT DRAWINGS WITHIN 10 WORKING DAYS OF PROJECT
<br />COMPLETION.
<br />19.CONTRACTOR IS TO EXCAVATE 6" BELOW EXISTING GRADE AND SPRAY WITH WEED CONTROL. REPLACE WITH
<br />CLASS II AGGREGATE BASE AND CRUSHED WASHED ROCK. AS SPECIFIED ON SITE PLAN.
<br />20.CONTRACTOR SHALL PROVIDE TOILET FACILITY DURING ALL PHASES OF CONSTRUCTION.
<br />21.PRIOR TO THE COMMENCEMENT OF CONSTRUCTION OR THE FABRICATION OF MATERIALS TO BE INSTALLED
<br />AT THE SITE, THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS INCLUDING AS-BUILT DIMENSIONS OF
<br />EXISTING STRUCTURES OR STRUCTURAL ELEMENTS HAVING A BEARING ON THE SCOPE OF THE WORK TO BE
<br />PERFORMED. IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING
<br />DRAWINGS AND THE DIMENSIONS OR CONDITIONS FOUND TO BE EXISTING IN THE FIELD, THE CONTRACTOR
<br />SHALL NOTIFY THE ENGINEER AND OBTAIN DESIGN RESOLUTION PRIOR TO PROCEEDING WITH THE
<br />PORTION(S) OF THE WORK AFFECTED. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE
<br />TO SO NOTIFY THE ENGINEER AND OBTAIN RESOLUTION BEFORE PROCEEDING.
<br />NOTES FOR EXISTING AT&T CELL SITES:
<br />1.PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING SUBCONTRACTOR SHALL VISIT THE CELL SITE TO
<br />FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS
<br />SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE
<br />ATTENTION OF CONTRACTOR.
<br />2.SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING ANY
<br />WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS MUST BE VERIFIED.
<br />SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL
<br />OR PROCEEDING WITH CONSTRUCTION.
<br />3.THE EXISTING CELL SITE IS IN FULL COMMERCIAL OPERATION. ANY CONSTRUCTION WORK BY
<br />SUBCONTRACTOR SHALL NOT DISRUPT THE EXISTING NORMAL OPERATION. ANY WORK ON EXISTING
<br />EQUIPMENT MUST BE COORDINATED WITH CONTRACTOR. ALSO, WORK SHOULD BE SCHEDULED FOR AN
<br />APPROPRIATE MAINTENANCE WINDOW USUALLY IN LOW TRAFFIC PERIODS AFTER MIDNIGHT.
<br />4.SINCE THE CELL SITE IS ACTIVE, ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN WORKING AROUND HIGH
<br />LEVELS OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE SHUTDOWN PRIOR TO PERFORMING
<br />ANY WORK THAT COULD EXPOSE THE WORKERS TO DANGER. PERSONAL RF EXPOSURE MONITORS ARE
<br />ADVISED TO BE WORN TO ALERT OF ANY DANGEROUS EXPOSURE LEVELS.
<br />5.SUBCONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, GROUNDING
<br />CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN DRAWING. SUBCONTRACTOR SHALL
<br />UTILIZE EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS NECESSARY. SUBCONTRACTOR SHALL CONFIRM
<br />THE ACTUAL ROUTING WITH THE CONTRACTOR.
<br />6.SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL
<br />CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE
<br />RETURNED TO THE OWNER'S DESIGNATED LOCATION.
<br />LEGEND 7
<br />-
<br />-
<br />-
<br />-
<br />A AMPERE
<br />A&E ARCHITECTURE AND ENGINEERING
<br />A.B. ANCHOR BOLT
<br />ABV. ABOVE
<br />AC ALTERNATE CURRENT/AIR CONDITIONER
<br />ACCA ANTENNA CABLE COVER ASSEMBLY
<br />ADD'L ADDITIONAL
<br />A.F.F. ABOVE FINISHED FLOOR
<br />A.F.G. ABOVE FINISHED GRADE
<br />AIC AMPERE INTERRUPTING CAPACITY
<br />ALUM. ALUMINUM
<br />ALT. ALTERNATE
<br />ANT. ANTENNA
<br />APPR0X. APPROXIMATE(LY)
<br />ARCH. ARCHITECT(URAL)
<br />AT. AMPERE TRIP
<br />AWG. AMERICAN WIRE GAUGE
<br />BATT. BATTERY
<br />BD. BOARD
<br />BLDG. BUILDING
<br />BLK. BLOCK
<br />BLKG. BLOCKING
<br />BM. BEAM
<br />B.N. BOUNDARY NAILING
<br />BR. BRANCH
<br />BRKR. BREAKER
<br />BTCW. BARE TINNED COPPER WIRE
<br />BTS. BASE TRANSMISSION SYSTEM
<br />B.O.F. BOTTOM OF FOOTING
<br />B/U BACK-UP CABINET
<br />C CONDUIT
<br />CAB. CABINET
<br />CANT. CANTILEVER(ED)
<br />CB. CIRCUIT BREAKER
<br />CDMA CODE-DIVISION MULTIPLE ACCESS
<br />CDUK CONSOLIDATION DISTRIBUTION UNIT KIT
<br />C.I.P. CAST IN PLACE
<br />CKT. CIRCUIT
<br />C CENTERLINE
<br />CLG. CEILING
<br />CLR. CLEAR
<br />CMU CONCRETE MASONRY UNIT
<br />COL. COLUMN
<br />CONC. CONCRETE
<br />CONN. CONNECTION(OR)
<br />CONST. CONSTRUCTION
<br />CONT. CONTINUOUS
<br />d PENNY (NAILS)
<br />DBL. DOUBLE
<br />DC DIRECT CURRENT
<br />DEM. DEMAND
<br />DEPT. DEPARTMENT
<br />D.F. DOUGLAS FIR
<br />DIA. DIAMETER
<br />DIAG. DIAGONAL
<br />DIM. DIMENSION
<br />DO DITO (THE SAME)
<br />DWG. DRAWING(S)
<br />DWL. DOWEL(S)
<br />(E)EXISTING
<br />EA. EACH
<br />EGR. EMERGENCY GENERATOR RECEPTACLE
<br />EL. ELEVATION
<br />ELEC. ELECTRICAL
<br />ELEV. ELEVATOR
<br />EMT. ELECTRICAL METALLIC TUBING
<br />E.N. EDGE NAIL
<br />ENCL. ENCLOSURE
<br />ENG. ENGINEER
<br />EQ. EQUAL
<br />ESR EVALUATION SERVICE REPORT
<br />EXP. EXPANSION
<br />EXT. EXTERIOR
<br />FAB. FABRICATION(OR)
<br />FAC. FACTOR
<br />F/A FIRE ALARM
<br />F.F. FINISH FLOOR
<br />F.G. FINISH GRADE
<br />F.J. FLOOR JOIST
<br />FIN. FINISH(ED)
<br />FLR. FLOOR
<br />FLUOR FLUORESCENT
<br />FDN. FOUNDATION
<br />F.O.C. FACE OF CONCRETE
<br />F.O.M. FACE OF MASONRY
<br />F.O.S. FACE OF STUD
<br />F.O.W. FACE OF WALL
<br />FRP FIBER REINFORCE POLYMER
<br />F.S. FINISH SURFACE
<br />FT.(') FOOT (FEET)
<br />FTG. FOOTING
<br />FU FUSE
<br />G GROUND
<br />GR GROWTH (CABINET)
<br />GA. GAUGE
<br />GALV. GALVANIZE(D)
<br />GEN. GENERATOR
<br />G.F.C.I. GROUND FAULT CIRCUIT INTERRUPTER
<br />GLB. (GLU-LAM) GLUE LAMINATED BEAM
<br />GND GROUND
<br />GPS GLOBAL POSITIONING SYSTEM
<br />GRND. GROUND
<br />GSM GLOBAL SYSTEM MOBILE
<br />HDBC HARD DRAWN COPPER WIRE
<br />HDR. HEADER
<br />HGR. HANGER
<br />HPS HIGH PRESSURE SODIUM
<br />HT. HEIGHT
<br />ICC INTERNATIONAL CODE COUNCIL
<br />ICGB. ISOLATED COPPER GROUND BUS
<br />ILC INTEGRATED LEAD CENTER
<br />IN.(") INCH(ES)
<br />INT. INTERIOR
<br />L.LONG(ITUDINAL)
<br />LARR LOS ANGELES RESEARCH REPORT
<br />LB.(#) POUND(S)
<br />L.B. LAG BOLTS
<br />L.F. LINEAR FEET (FOOT)
<br />LG. LENGTH
<br />LPS LOW PRESSURE SODIUM
<br />LTE LONG TERM EVOLUTION
<br />MAS. MASONRY
<br />MAX. MAXIMUM
<br />M.B. MACHINE BOLT
<br />MECH. MECHANICAL
<br />MFR. MANUFACTURER
<br />MIN. MINIMUM
<br />MISC. MISCELLANEOUS
<br />MLO MAIN LUGS ONLY
<br />MTD. MOUNTED
<br />MTG. MOUNTING
<br />MTL. METAL
<br />MTS. MANUAL TRANSFER SWITCH
<br />N NEUTRAL
<br />(N) NEW
<br />NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOC.
<br />NO.(#) NUMBER
<br />N.T.S. NOT TO SCALE
<br />OBIF OPTICAL BASEBAND INTERFACE
<br />OH OVERHEAD
<br />O.C. ON CENTER
<br />OPNG. OPENING
<br />(P)PROPOSED
<br />P POLE
<br />P/C PRECAST CONCRETE
<br />PCS PERSONAL COMMUNICATION SERVICES
<br />PH PHASE
<br />PLY. PLYWOOD
<br />PNLBD PANELBOARD
<br />PPC POWER PROTECTION CABINET
<br />PRC PRIMARY RADIO CABINET
<br />L.PROPERTY OR PROPERTY LINE
<br />PRI PRIMARY
<br />P.S.F. POUNDS PER SQUARE FOOT
<br />P.S.I. POUNDS PER SQUARE INCH
<br />P.T. PRESSURE TREATED
<br />P.T.D.F. PRESSURE TREATED DOUGLAS FUR
<br />PWR. POWER
<br />QTY. QUANTITY
<br />RAD.RADIATION
<br />R RADIUS
<br />RBS RADIO BASE STATION
<br />RCPT. RECEPTACLE
<br />REF. REFERENCE
<br />REINF. REINFORCEMENT(ING)
<br />REQ'D. REQUIRED
<br />RF RADIO FREQUENCY
<br />RGS. RIGID GALVANIZED STEEL
<br />R.J. ROOF JOIST
<br />R.R. ROOF RAFTER
<br />RRU REMOTE RADIO UNIT (RADIO TRANSCEIVER)
<br />RX-AIT RECEIVER AIR INTERFACE TRAY
<br />SAF SAFETY
<br />SAQ SITE ACQUISITION
<br />SCH. SCHEDULE
<br />SDBC SOFT DRAWN BARE COPPER SEC SECONDARY
<br />SHT. SHEET
<br />SIM. SIMILAR
<br />S.N. SOLID NEUTRAL
<br />SPEC. SPECIFICATION(S)
<br />SQ. SQUARE
<br />S.S. STAINLESS STEEL
<br />STD. STANDARD
<br />STL. STEEL
<br />STRUC. STRUCTURAL
<br />SURF SURFACE
<br />SW SWITCH
<br />TEL. TELEPHONE
<br />TEMP. TEMPORARY
<br />THK. THICK(NESS)
<br />TMA TOWER MOUNTED AMPLIFIER (DC SUPPLY VOLTAGE)
<br />T.N. TOE NAIL
<br />T.O.A. TOP OF ANTENNA
<br />T.O.C. TOP OF CURB
<br />T.O.F. TOP OF FOUNDATION
<br />T.O.P. TOP OF PLATE OR PARAPET
<br />T.O.R.TOP OF ROOF
<br />T.O.S. TOP OF STEEL
<br />T.O.W. TOP OF WALL
<br />TYP. TYPICAL
<br />U.G. UNDER GROUND
<br />U.L. UNDERWRITERS LABORATORY INC.
<br />UMTS UNIVERSAL MOBIL TECH. SYS.
<br />U.N.O. UNLESS NOTED OTHERWISE
<br />V VOLT
<br />VAC VOLT ALTERNATING CURRENT
<br />V.I.F. VERIFY IN FIELD
<br />W WATT OR WIRE
<br />WD WIDE(WIDTH)
<br />W/ WITH
<br />W/O WITHOUT
<br />WD. WOOD
<br />W.P. WEATHERPROOF
<br />WT. WEIGHT
<br />XFER TRANSFER
<br />XFMR TRANSFORMER
<br />XLPE CROSS-LINK POLYETHYLENE
<br />1
<br />1
<br />L
<br />PROPERTY LINE / LEASE AREA
<br />NEW POWER CABLE
<br />NEW FIBER CABLE
<br />NEW POWER AND FIBER CABLES
<br />NEW HYBRID CABLES
<br />OVERHEAD POWER CABLES
<br />OVERHEAD COMMUNICATIONS CABLES
<br />EXISTING POWER CABLES
<br />EXISTING COMMUNICATION CABLES
<br />EXISTING WATER PIPES
<br />EXISTING SEWER PIPES
<br />EXISTING STORM DRAIN PIPES
<br />EXISTING GAS PIPES
<br />EXISTING GASOLINE PIPES
<br />CHAIN-LINK FENCING
<br />GROUTED OR PLASTER
<br />BRICK
<br />MASONRY
<br />CONCRETE
<br />STEEL
<br />EARTH
<br />GRAVEL
<br />PLYWOOD
<br />SAND
<br />WOOD CONTINUOUS
<br />WOOD BLOCKING
<br />SPOT ELEVATION
<br />REVISION
<br />GRID REFERENCE
<br />ELECTRICAL BOX
<br />TELEPHONE BOX
<br />ELECTRICAL METER
<br />SAFETY SWITCH (DISCONNECT)
<br />AUTOMATIC TRANSFER SWITCH
<br />CIRCUIT BREAKER
<br />ELECTRICAL SWITCH
<br />SMOKE DETECTOR
<br />TRANSFORMER
<br />UTILITY POLE
<br />POLE MOUNTED XFMR
<br />PAD MOUNTED XFMR
<br />DETAIL REFERENCE
<br />ELEVATION REFERENCE
<br />SECTION REFERENCE
<br />PWR
<br />FBR
<br />OHP
<br />OHT
<br />E
<br />T
<br />W
<br />S
<br />SD
<br />G
<br />GS
<br />X
<br />CENTER LINE
<br />E
<br />T
<br />M
<br />-
<br />-
<br />NEW COAX CABLES
<br />S
<br />S
<br />P/F
<br />HYBD
<br />COAX
<br />GROUND ROD
<br />GROUND ROD WITH INSPECTION/TEST WELL
<br />EXOTHERMIC GROUND CONNECTION
<br />COMPRESSION GROUND CONNECTION
<br />CHEMICAL ELECTROLYTIC GROUNDING
<br />GROUNDING CONDUCTOR
<br />GROUND BAR
<br />NOT
<br />
<br />F
<br />O
<br />R
<br />CON
<br />S
<br />T
<br />R
<br />U
<br />C
<br />T
<br />I
<br />O
<br />N
<br />NOT
<br />
<br />F
<br />O
<br />R
<br />CON
<br />S
<br />T
<br />R
<br />U
<br />C
<br />T
<br />I
<br />O
<br />N
<br />NOT
<br />
<br />F
<br />O
<br />R
<br />CON
<br />S
<br />T
<br />R
<br />U
<br />C
<br />T
<br />I
<br />O
<br />N
<br />NOT
<br />
<br />F
<br />O
<br />R
<br />CON
<br />S
<br />T
<br />R
<br />U
<br />C
<br />T
<br />I
<br />O
<br />N
|