Page # 6 <br />CALCULATION OF ROOF DEAD AND LIVE LOADS <br />Roof Dead Load Material Load <br />Roof Category Description All MPs <br />Roofing Type Comp Roof 2.5 psf <br />Number of Layers 1 <br />Underlayment Roofing Paper 0.5 psf <br />Plywood Sheathing Yes 1.5 psf <br />Board Sheathinq None 0.0 psf <br />Rafter Size and Spacng 2 x 6 @ 24 in. O.C.1.1 psf <br />Vaulted Ceiling None 0.0 psf <br />Miscellaneous Miscellaneous Items 1.4 psf <br />Total Roof Dead Load 7.0 psf7 psf (All MPs) <br />Reduced Roof Live Load Symbol Value ASCE 7-05 <br />Roof Live Load Lo 20.0 Rsf Table 4-1 <br />Member Tributary Area At £ 200 sf <br />Roof Slope 3/12 <br />Tributary Area Reduction Rl 1 Section 4.9 <br />Sloped Roof Reduction Rz 1 Section 4.9 <br />Reduced Roof Uve Load Lr 4 = Lo (Rl) (R2)Equation 4-2 <br />Reduced Roof Live Load Lr 20 psf (All MPs)20.0 psf <br />Ceiling Dead Load Material Load <br />Ceiling Joist Size and Spacing_____ _2 x 6 _ @ 16 in. O.C.1.7 psf <br />Insulation Yes 1.4 psf <br />Finish 1/2" Gypsum Board _2.2 psf <br />Miscellaneous Miscellaneous Items 1.7 psf <br />Total Ceiling Dead Load 7 psf (All MPs)7.0 psf <br />Interior Walls Material Load <br />Finish (Side A) _1/2" Gypsum Bpard 2.2 psf <br />Wall Studs . 2x4 @ 16 in. O.C. -1.-1 psf <br />Insulation No 0.0 psf <br />finish (Side B)1/2" Gypsum Board 2.2 psf <br />Miscellaneous Miscellaneous Items 0.5 psf <br />Total Interior Wall Load 6 psf (All MPs)6.0 psf <br />Exterior Walls <br />Exterior Finish <br />Wall 54'ds ___ <br />Insulation <br />interior F#lish <br />Miscellaneous <br />Total Exterior Wall Load <br />Material Load <br />7/8" Stucco 12.0 psf <br />2 x 4_ _ _ - ___@ 1676. 0.6 -- - ii psf <br />Yes 1.4 psf <br />1/21Gyb®jil ®acd__-f_ -_f. 3_32 pst_ <br />Miscellaneous Items 1.3 psf <br />18 psf (All MPs)18.0 psf <br />r