Laserfiche WebLink
;SIONAL <br />G LICENCES PRINTED ON 08/30/2011 <br />5 GENERAL NOTES AND SPECIFICATIONS <br />10/31/11 1 DESIGN CODE & LOADS <br />1001/11 <br />1. THE STRUCTURES INCLUDED WITHIN THE SCOPE OF THESE DRAWINGS HAVE BEEN <br />11/30411 DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2006 AND 2009 <br />INTERNATIONAL BUILDING CODE (IBC), 2006 AND 2009 INTERNATIONAL <br />12/31/11 licio RESIDENTIAL CODE (IRC) AND THE 2010 CAUFORNIA 8UILDING CODE PROVISIONS <br />THAT ARE LOCALLY ENFORCEABLE AND UNDER THE JURISDICTION OF CfTY AND <br />1201/11 COUNTY BUILDING OFFICIALS. PROVISIONS RELATED SPECIFICALLY TO HOSPITAL-S <br />AND PUBUC SCHOOLS IN CALIFORNIA ARE NOT A PART OF THE SCOPE. <br />12/31/11 <br />2. THE STRUCTURES INCLUDED WITHIN THE SCOPE OF THESE DRAWINGS ARE <br />1231/11 INTENDED FOR RECREATIONAL/OUTDOOR USE AND ARE CONSIDERED <br />NON-HABITABLE STRUCTURES. <br />1281111 <br />3. SEISMIC DESIGN PARAMETERS: <br />123111 1 <br />a. IMPORTANCE FACTOR - 1.0 <br />12'3Ull b. Ss - 2.5 MAX - SEE LRP-6 <br />c. Si - 0.75 (0.60 WITH Sl>30 PSF) <br />12/31/11 d. SITE CLASS - D <br />e. Sos - 1.67 MAX <br />12131/11 f. Soi - 0.75 <br />g. PEISMIC DESIGN CATEGORY - D <br />1281/11 h. R - 1.25 <br />i. Cs - 1.33 MAX <br />01/31/12 j. DESIGN BASE SHEAR - 1.33 MAX W (ULTIMATE) <br />k ANALYSIS METHOD - EQUIV LATERAL FORCE <br />0301/12 <br />4. WHERE ASCE 7 IS REFERENCED, ASCE 7-05 WAS USED FOR THESE <br />03.31/TZ DOCUMENTS. <br />0400/12 5. MINIMUM SOIL BEARING CAPACITY SHALL BE 1000 PSF. <br />04/30/12 <br />04£30/12 11 MATERIALS <br />0130'12 1. ALUMINUM FOR COMPONENTS SHALL BE AS SHOWN ON THE ALLOY AND <br />TEMPER 6005-T5, (UON). <br />013CM 2 <br />2. ALUMINUM SHALL BE PAINTED IN ACCORDANCE WITH THE REQUIREMENTS SET <br />06'Owlz FORTH IN PART 1-A. SECTION 6.6 AND 6.7 OF THE ALUMINUM DESIGN <br />MANUAL (2005) <br />06/30/12 <br />0630fl2 3. SHEET METAL SCREWS (SMS) SHALL BE TYPE AB SCREWS. <br />06/30/12 4. SHEET METAL SCREWS SHALL CONFORM TO THE REQUIREMENTS SET FORTH <br />IN PART 1-A OF THE LATEST ALUMINUM DESIGN MANUAL FOR TAPPING <br />06/30/12 SCREW CONNECTIONS. <br />06930/12 5. EXPANSION ANCHORS SHALL BE HILTT 3/8' UKWIK BOLT TZ" OR APPROVED <br />EQUAL ANCHORS SHALL BE AS DESCRiBED 8Y AND IN5TALLED PER ICC-ES <br />072412 REPORT ESR-1917. ANCHORS SHALL BE PLACED SUCH THAT THE DISTANCE <br />TO CONCRETE EDGE, CRACKS AND JOINTS IS NOT LESS THAN 4 1/2". <br />07/31.t12 <br />6. WHERE ATTACHMENT TO EXISTING STRUCTURE OCCURS, THE WOOD OF THE <br />07/31/12 EXISTING STRUCTURE SHALL HAVE A MINIMUM SPECIAC GRAWrY OF 0.49. <br />SUCH AS DF. <br />07/31/12 <br />7. WHERE SCREWS ARE INSTALLED INTO WOOD FRAMING, THE CONTRACTOR0781112SHALL VERIFY, THROUGH NON-DESTRUCTIVE MEANS, THAT EACH SCREW HAS <br />0980/12 A MINIMUM OF 1/2" SIDE COVER ON ALL SIDES OF THE SCREW. <br />1120/12 8. ALL WOOD SHOWN WITHIN THESE DRAWINGS SHALL HAVE A SPECIFIC GRAVITY <br />OF 0.49 OR GREATER. LUMBER ALLOWABLE STRESSES HAVE BEEN BASED ON <br />12131/12 THE 2005 NDS. <br />1281/12 9. ALL NAILS AND WOOD 'SCREWS SHALL HAVE THE FOLLOWING MINIMUM YIELD <br />STRENGTH: <br />12£31112 <br />a. 8d:Frb = 100,000 psi <br />1281/12 b. 12d:Frb = 80,000 psi <br />c. 14d:Frb = 70,000 psi <br />1261M2 d. 16d:Frb = 70,000 psi <br />e. 18d:Frb = 60.000 psi <br />12/3112 f. 2Od:Frb = 60,000 psi <br />02'28/13 10. FASTENERS USED FOR ATTACHING TO PRESSURE TREATED LUMBER SHALL BE <br />STAINLESS STEEL. <br />03/31/13 <br />11.UNLESS. OTHERWISE NOTED, ALL STEEL IN CONTACT WITH PRESSURE <br />04m/13 TREATED LUMBER SHALL HAVE A G 185 GALVANIZED COATING. <br />06130/13 <br />12. CONCRETE SHALL BE TYPE V CEMENT WITH A MINIMUM,W/C RAnO OF 0.45 <br />0630113 AND A MINIMUM COMPRESSIVE STRENGTH (FC) = 4500 PSI. WHERE <br />CONCRETE IS NOT EXPOSED TO SULFATE, TYPE Il CEMENT MAY BE USED <br />0861113 AND THE MINIMUM COMPRESSIVE STRENGTH (FC) MAY BE 2500 PSI <br />030,M3 13.STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 <br />01'31/14 14.REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 40 OR 60. <br />0381/14 15 BOLTS SHALL CONFORM TO ASTM A307. <br />IAPMO ES REPORT #0115 <br />111 ROOF SYSTEM <br />1. THE ROOF PANELS SHALL BE AS DEFINED W/IN THIS DRAWING <br />PACKAGE AND PANEL SPANS SHALL BE LIMITED TO THOSE SHOWN. <br />2. UON, MAXIMUM ROOF PANEL OVERHANGS SHALL BE 24*. <br />3. FOR COVERS W/0 AN ENCLOSURE, ROOF PANELS SHAU_ BE <br />SUPPORTED BY A BEAM, POST & FOOTING SYSTEM SUITABLE FOR THE <br />PROPOSED APPUCATION. THE BEAM. POST & FOOTING SYSTEM SHALL <br />BE DEFINED WITHIN A VAUD IAPMO EVALUATION REPORT, A VAUD <br />ICC-ES EVALUATION REPORT OR WrrHIN AN ENGINEERING PACKAGE <br />SIGNED BY A P.E. LICENCED IN THE LOCAL JURISDICTION. A COPY OF <br />SAID REPORT OR ENGINEERING PACKAGE SHALL BE SUBMITTED TO THE <br />BUILDING OFFICIAL @ THE TIME OF PERMIT APPUCATION. <br />IV WALL SYSTEMS <br />1. FOR COVERS WITH AN ENCLOSURE, THE ENCLOSURE SYSTEM SHALL BE <br />SUITABLE FOR THE PROPOSED APPUCAnON.THE ENCLOSURE SYSTEM <br />SHALL BE DEFINED WITHIN A VAUD LAPMO EVALUATION REPORT, A <br />VALID ICC-ES EVALUAPON REPORT OR WITHIN AN ENGINEERING <br />PACKAGE SIGNED BY A P.E UCENSED IN THE LOCAL JURISDICTION. A <br />COPY OF SAID REPORT OR ENGINEERING PACKAGE SHALL BE <br />SUBMITTED TO THE BUILDING OFFICIAL AT THE nME OF PERMIT <br />APPUCATION. <br />V LAMINA-FED ROOF PANELS <br />1. THE FOAM CORE ROOF PANELS DEPICTED WITHIN THIS DRAWING ARE <br />INTENDED FOR USE ON RESIDENTIAL PAROS AS REGULATED BY APPENDIX <br />CHAPTER I OF THE INTERNATIONAL BUILDING CODE OR APPENDIX <br />CHAPTER H OF THE INTERNATIONAL RESIDENTIAL CODE <br />2. MATERIALS: <br />o. INTERIOR FACING MATERIAL SHALL BE ALUMINUM CONFORMING TO <br />THE REQUIREMENTS FOR 3105-H 14 ALLOY AND TEMPER. <br />THICKNESS OF SKIN SHALL BE AS SHOWN IN THE APPROPRIATE <br />ALLOWABLE SPAN TABLE. <br />b. EXTERIOR FACING MATERIAL SHALL BE ALUMINUM CONFORMING TO <br />THE REQUIREMENTS FOR 3105-H 14 ALLOY AND TEMPER. <br />THICKNESS OF SKIN SHALL BE AS SHOWN IN THE APPROPRIATE <br />ALLOWABLE SPAN TABLE. <br />c. THE FOAM CORE SHALL BE AS DEFINED BELOW AND HAVING A <br />NOMINAL DENSnY AS SHOWN IN THE ALLOWABLE SPAN TABLE: <br />i. PREFORMED EXPANDED POLYSTYRENE BOARD (EPS), AS <br />MANUFACTURED BY HOUSTON FOAM PLASTICS OF HOUSTON, <br />TEXAS. THE FOAM PLASnC SHALL MEET THE REQUIREMENTS FOR <br />CLASS A MATERIAL PER CHAPTER 8 OF THE 2006 IBC. FOAM <br />PLASnC IS CLASSIFIED AS TYPE 11 FOAM IN ACCORDANCE WITH <br />ASTM C578. <br />d. THE COMPONENTS ARE BONDED TOGETHER USING AN ADHESIVE <br />PROVIDED 8Y ASHLAND SPECIALTY CHEMICALS AND KNOWN AS <br />ISOGRIP SP50400.THE ADHESIVE IS RECOGNIZED UNDER BC-ES <br />ESR-1140. <br />3. THE MANUFACTURER OF ANY COMPONENT CITED IN ITEM 2 ABOVE SHALL <br />PROVIDE CERTIFICATION WITH EACH SHIPMENT THAT ALL COMPONENTS <br />PROVIDED WITHIN THE SHIPMENT CONFORM TO THE APPLICABLE <br />SPECIFICATION (S) AND/OR DEFINITION (S) OUTUNED ABOVE. <br />4. THE MAXIMUM ALLOWABLE SPAN, FOR A GIVEN APPLIED LOAD SHALL NOT <br />EXCEED THE SPAN PROVIDED IN THE ALLOWABLE SPAN TABLE FOR SAID <br />LOAD.EXTRAPOLATION OF THE INFORMATION PROVIDED IN THE <br />ALLOWABLE SPAN TABLE IS NOT PERMITrED. <br />5. PANELS SHALL BE CONTINUOUS IN THE DIRECTION OF SPAN WITH NO <br />TRANSVERSE JOINTS. <br />6. THE STRUCTURAL SUPPORT AND 5rRUCTURAL ATTACHMENT OF THE <br />SUBJECT PANELS SHALL BE SUBSTANTIATED BY EITHER APPROVED <br />EVALUATION REPORT PLANS OR STRUCTURAL PLANS APPROVED BY THE <br />GOVERNING JUR{SDICTION. THE GOVERNING JURISDICTION SHALL CONFIRM <br />THAT SAlD PLANS ARE INTENDED FOR USE WITH THE DESIRED PANEL <br />LOADS AND SPANS FOR EACH SPECIFIC PROJ.ECT. <br />7. ALL PANEL EDGES SHALL BE SHIELDED IN ALUMINUM SECTIONS. ALL <br />INTERFACES BETWEEN THE ALUMINUM SECTONS AND PANEL SHALL BE <br />CAULKED WITH· APPROPRIATE SEALANT. <br />8. METAL PANEL FASTENERS SHALL BE ALUMINUM. STAINLESS STEEL OR <br />ALUMINIZED, HOT-DIP GALVANIZED OR ELECTROGALVANIZED STEEL. <br />Z <br />C <br />GLRP-:£ 1 30 2 133HS 'DU02!Af 'OPDAIN '0 <br />THIS BAR FULL SCALE <br />IAPMO PAGE NUMBER 2 OF 23 6 <br />Z <br />mNOTE TO DEALER, CONTRACTOR AND M <br />BUILDING OFFICIAL: <br />1. STRUCTURES INCLUDED WfTHIN THIS PACKAGE SHALL NOT BE ATTACHED <br />TO SINGLE COAr STUCCO SYSTEMS UNLESS THE ATTACHMENT METHOD <br />IS SPECIFICALLY DESIGNED FOR "SINGLE COAr 5TUCCO SYSTEMS. - <br />2. SNOW LOADS PRESENTED WITHIN THESE PLANS ARE EQUIVALENT <br />UNIFORM SNOW LOADS. CONSIDERATION SHALL BE GIVEN TO SITE <br />SPECIFIC CONDmONS INCLUDING, BUT NOT UMITED TO, DRIFTING AND „ <br />SUDING SNOW. <br />3. STRUCTURAL ADEQUACY OF AN EXISTING STRUCTURE IS NOT INCLUDED 1 69WITHIN THE SCOPE OF THIS PACKAGE.STRUCTURAL ADEQUACY SHALL <br />BE INVESTIGATED BY OTHERS UNLESS DEEMED ADEQUATE BY THE W P <br />BUILDING OFFICIAL 520 <br />4. THESE PLANS APPLY TO MULTIPLE LOADING CONDmONS (WIND AND 1-Lz <br />GRAVITY). THE DEALER, CONTRACTOR OR EOR SHALL -MARK-UP' EACH 00 <br />PACKAGE TO CONFIRM THAT THE SITE SPECIFIC REQUIREMENTS ARE 24 <br />WRHIN THE SCOPE OF THE PACKAGE. D <br />&4 <br />IN PLAIN ENGLISH, THE PERSON USING THIS SET OF STANDARD PLANS -1 21 <br />SHALL USE THE PLANS, SECTIONS, DETAILS. TABLES AND INSTRUCTIONS <br />WITHIN THE PACKAGE TO CONFIRM THAT THE SITE SPECIFIC CONDmONS <br />ARE WrTHIN THE ALLOWABLE PARAMETERS PRESENTED WITHIN THIS SET <br />OF STANDARD PLANS.% <br />AMONG THE ACTIVITIES WHICH SHALL BE PERFORMED BY THE DEALER, <br />CONTRACTOR OR EOR ARE:.&2 * <br />A. REVIEW ALL NOTES TO CONFIRM WHAT WILL BE CONSTRUCTED <br />MEETS THE REQUIREMENTS PRESENTED WffHIN THE NOTES, <br />B. CONFIRM LOADING REQUIREMENTS W[TH THE LOCAL BUILDING <br />OFFICIAL, <br />C. IDENTIFY PARAMETERS WITHIN STEPS I TO VII ON SHEETS LRP-3 <br />TO LRP-7 WHICH ARE APPUCABLE TO THE SPECIFIC ROOF BBNG <br />CONSTRUCTED. <br />D. CROSS OUT ALL ELEMENTS MTHIN THE ENTIRE PACKAGE WHICH 8& <br />ARE NOT USED WITHIN THE SPECIAC ROOF.a= <br />ABBREVIATIONS mm <br />¢ DIAMETER FDN FOUNDAnON SIT SHEET <br />FTG FOOTING SIM SIMILAR 2== <br />AB ANCHOR BOLT SMS SHEET METAL SCREWS 5== 6 <br />At)DL ADDmONAL GA GAGE SP SPACE (S, ED) <br />ALUM ALUMINUM GALV GALVANIZED SPEC SPECIFICATION, <br />ANCH ANCHOR HGT HEIGHT SQ SQUARE C= & <br />SPECIFIED =2 <br />APPROX APPROXIMATE(CO <br />INFO INFORMATION SST STAINLESS STEEL-'fft' c <br />SAL BALANCE STAG STAGGERED <br />BLDG BUILDING him MANUFACTURER STD STANDARD qll iBM8EAMMlNMINIMUMSnFSnFFENER <br />B.0.BOTTOM OF MWFRS MAIN WIND FORCE STL STEEL- <br />RESTING SYSTEM STRUC STRUCTURE (S, URAL) -8OT 801TOM <br />SYhi SYMMETRICAL <br />C/C CENTER TO CENTER NA NOT ALLOWED T&B TOP AND BorrOMCt CEN1ERLINE NR NOT REQUIRED THD THREADED <br />COL COLUMN NTS NOT TO SCALE <br />THK THICK (NESS)CONC CONCRETE OC ON CENTER T.O.TOP OF <br />OD OUTSIDE DIA TYP PrPICAL NE iCONTCONTINUOUS33 5OH OVERHANG UON UNLESS 01}iERWISE NOTED . .U, fl/, =CTR CENTER (ED) . <m m .OPNG(S) OPENING(S)O.80' <br />OPP OPPOSITE VERT VERTICAL 90 W Z <br />DET DETAIL go I O <br />OPT OPTION (AL)801,2DF DOUG FIR W/ WITH Zm&g&DWG(S) DRAWING(S) PL PLATE W/0 WITHOUT <br />PROJ PRNECRON WS WOOD SCREW S S IN 3 S <br />EA EACH WT WEIGHT <br />RAD RADIUS -.1 0 . coEMBED EMBEDMENT <br />EQ EQUAL (LY)REF REFERENCE / REFER S /1/ i i <br />REINF REINFORCE (11 INC)ES EACH SIDE <br />EXP EXPANSION REQD REQUIRED <br />EXST E)(15nNG REV gi"C•gt. <br />f' 6 <br />g 1 02 <br />95 =%0 <br />0 8 N <br />//3\ <br />-- <br />5 sle Zagga¤ 13-P <br />S ul,l.17NA <br />* Af=A)#a=%920=2 <br />25,925•¤§1282:*RmFIRE:08=659*92*RES*gARe= STATE £2 <br />0 <br />PHONE: (000) 827-6045 <br />GENERAL NOTES <br />a BY COMMENT <br />FAX: (972) 882-8818 <br />DATE: <br />APRIL 2004X:\TJCAA - Stordard Plons\2003 Projects\30301-UUI, Enclosure STP Eng\LRP Revision 6.00.0 (IAPMO-2011 -08-30)\ MUI, LRP Standard Mon 05/30/11 13:55 andria XREFS: Tjco-bar, TJCAA Stomp List Inse <br />Utoh,