My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10179835_2800 N. MAIN - Plan (2)
PBA
>
Building
>
Plans
>
M
>
Main St
>
2800 N Main St Unit# 1038
>
10179835_2800 N. MAIN - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2021 11:51:22 AM
Creation date
10/25/2020 9:45:54 PM
Metadata
Fields
Template:
Plan
Permit Number
10179835
Full Address
2800 N Main St Unit# 1038
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
LED CHANNEL LETTER INSTALLAMON INSTRUCTIONS <br />Flush Mount Channel Letter Installation Instructions - LED Channel Letters <br />This sign is intended to be installed in accordance with the requirements of Article 600 of the <br />National Electrical Code andfor other applicable local codes. This includes proper grounding and <br />bonding of the sign. <br />1. Refer to the drawing included with the letter set that depicts the arrangement of the <br />subassemblies. <br />2. Unroll paper pattern, and tape to substrate. Level and center pattern on wall. Drill holes for <br />secondary low voltage whips and mounting holes, and then remove pattern. Mount letters on the <br />wall using the drawing as a guide. if letter set does not have rivet nuts, remove faces push <br />secondary low voltage whips through substrate. mount letters onto substrate, and then replace <br />faces. If the letterset does hme rivet nuts. install threaded rod into rivet nuts then push secondary <br />low voltage whips (run in metal conduit) through substrate and secure with hardware from the back <br />side of substrate. <br />3. Refer to wiring diagram below (igure 1) and the transformer breakdown diagram (provided with <br />letter set) to spike the secondary conductors. Each secondary circuit has a dedicated <br />transformer and is color coded on the transformer breakdown sheet. Connect all of the positive <br />leads (red or white insulation) from each letter in the secondary cifcuil together in parallel using UL <br />approved wire nuts or crimp connectors (crimped with manufacturer's specified crimping tool) <br />Next connect all of the negative leads (black insulation) from each letter the secondary circuit <br />together in parallel using UL approved wire nuts or crimp connectors (crimped with manufacturer's <br />specified crimping tool). Finally, connect all of the ground leads (bare wire with no insulation) from <br />each letter the secondary circuit together in parallel using UL approved wire nuts or crimp <br />connectors (crimped with manufacturer's specified crimping tool). Repeat this process for each <br />secondary circuit. <br />4. If a Sloan damp location rated transfomier is supplied, no transformer box is required (skip to <br />step 6). [fany other transformer is supplied, a transformer box will also be supplied. In this case, <br />mount the transformer boxes; OPEN SIDE UP, as close as possible to the center of the circuit <br />that will be powering. It should be mounted at the same height as the letter set to minimize whip <br />lengths. Next, install the transformer in the box as specified per the transformer box <br />manufacturer's instructions included. <br />5. Route the three secondary circuit leads (positive, negative and ground) inside tha transformer <br />box. <br />6. Connect the three secondary circuit leads (positive. negative and ground) to the transformer <br />and/or transformer box as specified per the transformer and/or transformer box manufacturefs <br />instructions included. <br />7. Connect the primary electrical supply to the transformer per the transformer manufacturer's <br />instructions included. <br />8. Repeat the steps above for each transformer Circuit. <br />9. At least one On/off switch, raled for the application, must be installed on the primary "hot" lead <br />within the line of sight of the transformers <br />10. Signs cannot be connected to a branch circuit exceeding 30 amperes. <br />Secondary Secondary <br />Circuit #1 Circuit #2 <br />9P#EPT <br />21520 kathern Street <br />Carloga Park, CA 91304 <br />T 800.525.55 19 <br />F 818.737.0415 <br />www.visiblegraphics.com <br />9,9" <br />I, j S f. ' : :E z: :·L-i .:E - {GI-}IIRith ff FI.·. H.:it-} ii::fici::i*S .-(i j· t f.: f.-{j\-·:- 44.: <br />./..
The URL can be used to link to this page
Your browser does not support the video tag.