Laserfiche WebLink
CITY OF SANTA ANA <br />Planning and Building Agency <br />. I <br />• <br />KEYPLAN <br />'7 <br />0 <br />ro <br />SGrand Ave enterllne <br />CD <br />1- a - i driveway — <br />- rcn� <br />oo e _ <br />-77 <br />G -0 <br />drvveway ;driveway , <br />I ,= <br />P1 <br />TJ �71i4 ark i i��-�1�I rg i <br />v �I <br />1 driveway 2 ...� driveway oI <br />rD <br />a k n l l t` p rki g o s Y m <br />L----�- ------------- ---� <br />a <br />a � <br />1 I_p <br />ELECTRICAL SERVICE NOTES <br />1. REFER TO S.C.E. DRAWING FOR NEW SERVICE FOR NEW COMPLETE INSTALLATION <br />REQUIREMENTS. <br />2. ALL SERVICE CONDUIT SWEEPS AND BENDS SHALL BE SCHEDULE 80 PVC. <br />3. ALL SERVICE CONDUIT SHALL BE MANDRELED AND CLEANED WITH APPROVED <br />PULLROPES INSTALLED. <br />4. CONTACT UTILITY INSPECTION AT LEAST 48 HOURS BEFORE CONSTRUCTION TO <br />SCHEDULE INSPECTION AND OBTAIN "UGS" INSTALLATION DRAWINGS. <br />5. CONTACT UNDERGROUND SERVICE ALERT A MINIMUM OF 2 WORKING DAYS PRIOR <br />TO DIG. <br />6. SUBMIT SHOP DRAWINGS OF ALL PROPOSED SERVICE EQUIPMENT TO SCE FOR <br />APPROVAL PRIOR TO ORDERING. <br />CATV COMMUNICATIONS SPECIFICATIONS <br />FOR UNDERGROUND SERVICE FEED: <br />1. CONTACT CATV SERVICE PLANNER PRIOR TO THE START OF CONSTRUCTION FOR <br />ALL REQUIREMENTS AND INSPECTIONS. <br />2. PVC CONDUIT SCHEDULE 40 (NON -CORRUGATED) OR EQUIVALENT. <br />CONDUIT TO BE PLACED FROM CATV PULLBOX, OR UTILITY POLE (AS MARKED <br />BY CATV REPRESENTATIVE) TO THE HOUSE TO BE CONTIGUOUS WITH NO MORE <br />THAN TWO 90 DEGREE BENDS OR COMBINATION OF BENDS TOTALING 180 <br />DEGREES. <br />3. CONDUIT WILL BE BURIED TO A MINIMUM COVERED DEPTH OF 36" FROM FINAL <br />GRADE ON PRIVATE PROPERTY. MINIMUM OF 12" SEPARATION FROM POWER <br />WHEN IN JOINT TRENCH. <br />4. ALL CONDUIT BENDS SHALL GIVE A MINIMUM RADIUS OF 24". <br />5. MULE TAPE OR EQUIVALENT REQUIRED IN ALL CATV CONDUITS. <br />6. ALL CONDUITS SHALL BE LEFT CLEAN, DRY AND FREE OF DEBRIS OR ANY OTHER <br />OBSTRUCTIONS. UNUSABLE CONDUITS SHALL BE REPLACED AT THE <br />DEVELOPERS/OWNERS EXPENSE. <br />7. PROVIDE AND PLACE AN INSULATED #6 SOLID COPPER GROUND WIRE FROM THE <br />PREWIRE LOCATION TO THE ELECTRICAL GROUND SOURCE, PROVIDING A <br />COMMON BOND WITH A SEPARATE CLAMP. CLAMP IS TO BE ACCESSIBLE. THIS <br />GROUND WIRE IS TO BE INSTALLED BY DEVELOPER'S LICENSED E.C. (SEE NEC <br />ARTICLE 250-81 a OR c, 250-8cm, 250-117). APPLICATIONS WITH 7 OR MORE <br />SERVICES WILL REQUIRE A 4'X4'x 3/4" BACKBOARD. <br />E <br />SITE POWER PLAN <br />GENERAL NOTES <br />ELECTRICAL CONTRACTOR SHALL EXERCISE EXTREME CAUTION IN EXCAVATING <br />ANDTRENCHING ON THIS SITE TO AVOID EXISTING CONDUITS, PIPING AND <br />DUCTS, ETC. AND TO PREVENT HAZARD TO PERSONNEL AND DAMAGE TO <br />EXISTING UNDERGROUND UTILITIES OR STRUCTURES. THE ENGINEER IS NOT <br />RESPONSIBLE FOR THE LOCATION OF UNDERGROUND UTILITIES OR <br />STRUCTURES WHETHER OR NOT SHOWN OR DETAILED AND INSTALLED BY THIS <br />OR ANY OTHER CONTRACTS. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY <br />THE OWNER SHOULD SUCH UNIDENTIFIED CONDITIONS BE DISCOVERED. THESE <br />DRAWINGS AND SPECIFICATIONS DO NOT INCLUDE NECESSARY COMPONENTS <br />FOR CONSTRUCTION SAFETY. <br />E.C. SHALL PROVIDE AND MAINTAIN REQUIRED WORK SPACE, ACCESS TO WORK <br />SPACE AND HEAD ROOM ABOUT ELECTRICAL EQUIPMENT AS PER TABLE <br />110.26(A)(1). <br />— — — — — — — — — — — <br />I <br />I <br />L------------ <br />1=1 1=rTDVr DnnRA <br />1/T — I -V <br />1. PROPOSED TRANSFORMER LOCATION, E.C. TO PROVIDE AND INSTALL PRECAST 101X12' <br />TRANSFORMER PAD. CONFIRM LOCATION AND REQUIREMENTS WITH UTILITY COMPANY <br />PRIOR TO COMMENCEMENT OF WORK. <br />2. COORDINATE EXACT LOCATIONS OF UTILITY SOURCES WITH CIVIL SITE UTILITIES PLAN <br />DRAWINGS. <br />3. MAIN SERVICE SWITCH BOARD'MSA' 2000A, 480Y/277V, 3P, 4W. <br />4. E.C. SHALL FURNISH AND INSTALL AND TRENCHING 2 BANKS OF (4) 4"C, 45-0", SPACED A <br />MIN. OF 6 APART PER TABLE 6-2 SCE WITH 3 #350 MCM AL IN EACH. FROM THE UTILITY <br />CO POINT OF CONNECTION TO THE UTILITY TRANSFORMER. CONFIRM ALL <br />INFORMATION WITH THE UTILITY COMPANY PRIOR TO INSTALLATION. <br />5. CONDUITS SIZE FOR UNDERGROUND PRIMARY SHALL BE DETERMINE BY S.C.E. <br />ENGINEER. <br />6. ELECTRIC SERVICE, PROVIDED AND INSTALLED BY E.C. <br />7. PROVIDE PROTECTIVE BARRIER AS DETERMINED MAX. 4'-6" APART. <br />8. E.C. SHALL FURNISH AND INSTALL CONDUIT, CONDUCTORS AND TRENCHING FROM THE <br />UTILITY CO POINT OF CONNECTION TO THE SERVICE EQUIPMENT. <br />2 BANKS OF (4) 4"C SPACED A MIN. OF 6' APART PER TABLE 6-2 SCE. <br />CONFIRM ALL INFORMATION WITH THE UTILITY COMPANY PRIOR TO INSTALLATION. <br />9. NEW SWITCHBOARD'MSA', 2000A, 277/480V, 3PH, 4W. <br />10. EXISTING PANEL'HB', 200A, 208/120V, 3P, 4W. WITH EXISTING FEEDER FROM DRY <br />TRANSFORMER'TT. <br />KEYNOTES <br />11. EXISTING DRY TRANSFORMER73', 75 KVA, E.C. IS TO INTERCEPT THE EXISTING <br />FEEDERS AND PROVIDE A JUNCTION BOX (SIZE TO MEET MINIMUM CEC REQUIREMENTS) <br />TO TRANSITION AND EXTEND FEEDERS TO RECONNECT TO NEW SWITCHBOARD'MSA'. <br />12. NEW PANEL, 700A, 480/277V, 3P, 4W. WITH NEW FEEDER FROM NEW SWITCHBOARD <br />'MSA'. <br />13. EXISTING 800A SERVICE SWITCHBOARD, FEEDER AND CONDUIT TO BE REMOVED BY E.C. <br />14. EXISTING 'T2' DRY TRANSFORMER, FEEDER AND CONDUIT TO BE REMOVED BY E.C. <br />15. EXISTING PANEL'HA', 200A, 480/277V, 3P, 4W. E.C. IS TO INTERCEPT THE EXISTING <br />FEEDERS AND PROVIDE A JUNCTION BOX (SIZE TO MEET MINIMUM CEC REQUIREMENTS) <br />TO TRANSITION AND EXTEND FEEDERS TO RECONNECT TO NEW SWITCHBOARD'MSA'. <br />16. EXISTING DRY TRANSFORMER71', 75 KVA, WITH EXISTING FEEDER FROM EXISTING <br />PANEL'HA'. <br />17. EXISTING PANEL 'LA', 200A, 2081120V, 3P, 4W. WITH EXISTING FEEDER FROM EXISTING <br />DRY TRANSFORMER'T1'. <br />18. EXISTING PANEL'LAA', 100A, 208/120V, 3P, 4W. WITH EXISTING FEEDER FROM EXISTING <br />PANEL 'LA'. <br />19. EXISTING PANEL'LAA1',100A, 208/120V, 1F, 3W. WITH EXISTING FEEDER FROM EXISTING <br />PANEL 'LAA'. <br />20. ALL ELECTRIC ROOM DOORS SHALL HAVE PANIC HARDWARE. ALL DOORS SHALL OPEN <br />IN THE DIRECTION OF EGRESS. COMPLY WITH ALL REQUIREMENTS OF CEC 110.26(C)(3). <br />0;® <br />02 UTILITY <br />,zo 0eGRGG:Z <br />MEP ENGINES ING <br />P <br />.1egr, z.c <br />FOR PFRM1c1Thqw2,c3wa I,1,1, <br />110. Q52l ric !ANC <br />ate:" <br />1/8" = 1'-0" 1 <br />0 <br />21. E.C. SHALL VISIT THE SITE PRIOR TO BID AND VERIFY LOCATIONS OF ALL EQUIPMENT <br />AND DEVICES. WHERE DISCREPANCIES OR OMISSIONS ARE FOUND, THE CONTRACTOR <br />SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND ENGINEER AND ADJUST THEIR BID <br />ACCORDINGLY. NO ALLOWANCES WILL BE MADE FOR EXISTING CONDITIONS (UNLESS <br />CONCEALED) OR THE CONTRACTORS FAILURE TO ACCOMMODATE EXISTING <br />CONDITIONS ON ANY BID. <br />22. PROVIDE FENCE FOR SCREENING; SEE TRANSFORMER DETAIL. SEE DETAIL No.3 ON <br />SHEET E2.0. VERIFY REQUIREMENTS WITH UTILITY AND ARCHITECT. <br />MEP Project No.: 25-070 <br />AL In <br />i <br />r: <br />ARCHITE.0 <br />CONSULTANTS: <br />SEAL & SIGNATURE: <br />QROF ESSlbi <br />P�\RI RA -1 <br />No. E20918 Z m <br />xp. 09 30. 26• <br />kp <br />CT R\G� Q� <br />OF CA L <br />ISSUED FOR: <br />DESCRIPTION: <br />UJ <br />U <br />/ <br />or. <br />W <br />� <br />Lo <br />0 <br />W <br />Q <br />N <br />0') <br />Z <br />Q <br />U <br />Q <br />Q <br />Q <br />O <br />(D <br />Q <br />O <br />O <br />6 <br />� <br />Q <br />� <br />NC:)a <br />U) <br />W <br />Z <br />KEY PLAN <br />NORTH <br />SHEET NAME: <br />DATE: <br />GROUNDFLOOR <br />POWER PLAN <br />PROJECT NO.: SHEET NO.: <br />25-070 <br />DRAWN BY: <br />CHECKED BY: El m0 <br />SCALE: <br />QQ Copyright 120DEGREEZ 2019 <br />