My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10179928_2505 N. DEODAR - Plan (2)
PBA
>
Building
>
Plans
>
D
>
Deodar St
>
2505 N Deodar St
>
10179928_2505 N. DEODAR - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2021 8:34:20 AM
Creation date
10/25/2020 9:46:08 PM
Metadata
Fields
Template:
Plan
Permit Number
10179928
Full Address
2505 N Deodar St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
. MARKING FORMAT: <br />- -WHITE LETTERING ON RED BACKGROUND <br />·MINIMUM 3/8 INCH LETTERING <br />. -ALL LETTERS SHALL BE CAPITALIZED <br />' -ARIAL FONT <br />WARNING LABEL LOCATIONS <br />A. EXISTING MAIN ELECTRICAL SERVICE PANEL <br />REFLECTIVE WEATHER RESISTANT MATERIAL <br />SUITABLE FOR THE ENVIRONMENT. <br />B. NEW NEMA 3R COMBINER FOR MICROINVERTERS ONLY <br />ALL SYSTEM LABELS AND WARNINGS TO BE <br />INSTALLED AT THE SITE AND THEIR LOCATION <br />IN ACCORDANCE WITH ARTICLE 690 OF THE 2010 <br />CALIFORNIA ELECTRICAL CODE. <br />LABEL TO BE INSTALLED AT SERVICE PANEL <br />WARNING <br />ELECTRICAL SHOCK HAZARD IF A <br />GROUND FAULT IS INDICATED, <br />NORMALLY GROUNDED CONDUCTORS <br />MAY BE UNGROUNDED AND ENEGIZED <br />-.- <br />WARNING ..r <br />ELECTRICAL SHOCK HAZARD to <br />IF A GROUND FAULT IS <br />- INDICATED, NORMALLY GROUNDED <br />CONDUCTORS MAY BE UNGROUNDED .... <br />AND ENERGIZED. <br />0WARNING: Ul <br />INVERTER OUTPUT · # <br />U)Z- CONNECTION U)<8 <br />DO NOT RELOCATE THIS 2 & 8 <br />OVERCURRENT DEVICE.E u.1 2 <br />L7 L7 <br />I . <br />- CAUTION: <br />THIS SERVICE IS FED FROM <br />MULTIPLE SOURCES: <br />GRID AND PV ARRAY <br />0 <br />5 9 <br />3.9702 <br />05= c <br />ON® <br />acâ„¢ 0 <br />2 66 I <br />CE 8.2 <br />B. A. <br />CAUTION: - <br />PHOTOVOLTAIC SYSTEM <br />CIRCUIT BREAKER IS BACKFED <br />LABEL TO BE INSTALLED AT EACH: JUNCTION BOX, <br />COMBINER BOX, DISCONNECT AND DEVICE <br />WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY <br />BE EXPOSED DURING SERVICE. ART 690.35 (F)(CEC) <br />WARNING <br />ELECTRICAL SHOCK HAZARD. <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE <br />UNGROUNDED AND MAY BE <br />ENERGIZED. <br />PLANS PREPARED BY: <br />KYLE HUGHES <br />NOTE: WARNING LABELS <br />10 FEET OF CONDUITS, RACEWAYS, <br />ENCLOSURES, AND CABLE ASSEMBLIES. <br />NOTE:Date: 10-15-13 <br />Sheet <br />ALL EQUIPMENT IS SIDE ELEVATION CAUTION: SOLAR CIRCUIT Scale: N.T.S.E-1.5 <br /> MOUNTED BELOW 73" TO EQUIPMENT LOCATION DewinERVANTES <br />TOP OF DISCONNECT