Laserfiche WebLink
IGALVANIZED 21/2·x 12"x 7 GAGE THICK <br />fl STEEL STRAP W/4-5/8'0 LAGS <br />1 <br />- APPROVED CAP <br />i_ <br />31/2 <br />1+1 <br />4'x4' - J <br />POST-- <br />44 BEAM <br />4'x BEAM <br />9 -4-0- 4'14' KNEE bN. /BRACE N2.-A .1- 1 /t /1 <br />12-1/2' 0 x 5' LONG LAGS SCREWS -1-xe KNEE <br />j' A EACH END 1...d BRACE <br />---%- 1(SEE DETAIL'E') <br />/. <br />A I 444' POST MINIMUM LA J- <br />¥ <br />DETAIL "B"DETAIL "B" ALTERNATE <br />STANDOFF 1 .-1 -» <br />ISTAND-OFF -1' STAND-OFF <br />APOST/ 18ASE- FS>1 <br />• 12'1 4.x BEAM <br />ANCHOR <br />BOLT <br />EMBEDI .1 <br />ANCHORS IN K--·... <br />CONCRETEI ·-7 <br />-26-0 1 <br />GRADE-1 <br />DETAIL <br />+1 <br />31/2'1 <br />lili 0 <br />\ IGALVANIZED <br /> 12'x12'x7 GAGE <br />+ IT W/6-5/8' 0 LAGS <br />- 4'x POST . <br />x.2 2 94* I <br />/ <br />"C"4- <br />MI Ul NOTES: <br /> 1. ALL MATERIALS: LUMBER, HARDWARE, PLYWOOD, ROOFING, ETC. SHALL BE NEW <br />2. ALL CONSTRUCTION SHALL CONFORM TO THE CALIFORNIA BUILOING <br />AND BEAR MANUFACTURER'S OR CERTIFIED AGENCY'S GRADE MARK. <br />CODE CURRENTLY IN EFFECT.1 '4 6 4. POSTS SHALL BE MINIMUM 4°x4°.CONCRETE SLAB TO BE MINIMUM 31/2" THICK. <br />-4 D 00 5. BOTTOM OF POSTS SHALL BE ONE INCH (1 °) ABOVE SLAB.6. · ROOF SHEATING SHALL BE: <br />a. 1/2° PLYWOOD, CDX, 5 PLY EXTERIOR GLUE, WITH INDEX 32/16, T&G <br />rn O STRUCTURAL I, WITH 10 d AT 6' O/C AT SUPPORTED ENDS, AN[)12" O/C ALONG <br />INTERMEDIATE FRAMING MEMBERS, OR4 -b. 1" BOARD SPAN 32°; 2° SOLID T&G SPAN 8'-0°; 2%<2' SELF-SPACED SPAN 6'-0'. <br />7. ROOFING SHALL BE MIN. CLASS 'C" ROOF COVERING (CBC TABLE 1505.1) OF: <br />LO a. WOOD SHAKES: 4/12 PITCH <br />b. WOOD SHINGLES: 3/12 PITCH <br />c. BUICT-UP ROOF SLOPE TO DRAIN (MINIMUM 1/4°/FT.) <br />d. CLAY AND CONCRETE ROOF TILES INSTALLED IN ACCORDANCE WITH <br />MANUFACTURER'S INSTRUCTIONS. <br />8. MAXIMUM HEIGHT FOR A PATIO COVER IS TWELVE FEET. <br />9. PATIO COVER SHALL BE·USED ONLY FOR RECREATIONAL OUTDOOR LIVING <br />PURPOSE AND NOTAS CARPORT, GARAGE, STORAGE ROOM OR HABITABLE ROOM. <br />10. ENCLOSURE WALLS MAY HAVE ANY CONFIGURATION, PROVIDED THE OPEN AREA <br />OF THE LONGER WACLAND ONE ADDITIONAL WALL IS EQUAL TO AT LEAST SIXTY- <br />- FIVE PERCENT·QF THE AREA BELOW A MINIMUM'OF 6'-8' OF EACH WALL, <br />MEASURED FROM THE FLOOR. <br />11. OPENINGS MAY BE ENCLOSED WITH INSECT SCREENING OR PLASTIC THAT IS <br />REAbILY REMOVABLE, TRANSLUCENT, OR TRANSPARENT PLASTIC NOT MORE THAN <br />la INCH IN THICKNESS. <br />12. EMERGENCY EGRESS OR RESCUE WINDOWS FROM SLEEPING ROOMS MAY OPEN <br />INTO AN AREA OF AN UNENCLOSED PATIO COVER. <br />13. PAT10 COVER MUST BE AT LEAST 5 FEET FROM PROPERTY LINES. <br />DETAIL "D" <br />- 4')(4' KNEE BRACE <br />r 2-1/2» 0 )(5» LONG LAG SCREWS <br />-0-0- <br />1-1- <br />E- 4'x POST <br />--4- <br />DETAIL "E" <br />PERSON RESPONSIBLE FOR DESIGN AND CONSTRUCTION OF PATIO COVER: <br />-TAN/\ 2409 6.J -32%C 1/>4//3 <br />PRINT NAME SIGNATURE DATE{ <br />rev: 07/19/2011 Page 2 of 2 <br />. <br />..2- .