Laserfiche WebLink
51 SIGN COMPONENTS MANUAL (SAM)October 1, 20.3 <br />LED 60CV 12P 100 - 277 0.8-0.3 12 60 <br />LED 60CV 24P 100 - 277 0.8 - 0.3 24 60 <br />3. These power supplies are only suitable for use in dry and damp locations. <br />4. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum,2 inches spacing to top of enclosure. <br />Compahy name or trademarks Light€:ch™ d Ligh·echLED Driver Hologen Tran#forme#and model designation. <br />GE LIGHTING SOLUTIONS LLC <br />BLDG 338E <br />1975 NOBLE RD <br />EAST CLEVELAND, OH 44112 USA <br />E219167 <br />Border tube kits, Includes Lens Cat. No. GExxBTL; Lens connector Cat. No. GExxBILC: End cap Cat. No. GExxBTLEC: Exterior <br />corner kit Cat No GExxBTLXC, Interior corner kit Cat. No. GExxBTLIC: Base reflector Cat No. GEBTBR: Base connector Cat. <br />No. GEBTBC; Cam lock Cat. No. GEBTCL. Canopy Kits. Cat. No. GECPL (8 ft length), GECPEC (end cap), GECPLC, (lers <br />connector), GESTBCL, GEBTBC. Light guide kits includes: Light guide Cat. No. GEXNLGXX-XXX, Light Guide End Cap Cat. <br />No. GEXXXNLGECZZ, XXX may be any alpha letter representing color. ZZ may be any alpha letter representing size. Light <br />Guide Connector Cat. No. GEXXXNLGYZZ, XXX may be any alpha letter representing color, Y can be any alpha character <br />describing the type of connector. ZZ may be any alpha letter representing size.. Mounting clip Cat. No GEXNMCXX; Supply <br />wire Cat. No. GEXNSXX: Spice connector Cat. No. GEXNSC1: Weather box Cat. No. GEXWBXX-XXX. <br />1. Border Tube Kit, Canopy Kit and Light Guide Kit are for Wet Location only use when enclosing LED's connected to a Class 2 <br />circuit operating at under 30V continuous DC. 12.4'V interrupted at a rate of 10-200Hz DC, or 15 VAC. <br />2. The LED border tube kit and Canopy Kit was not evaluated as an electrical enclosure. <br />3. The LED border tube kit and Canopy Kit was not evaluated as a watertight housing. <br />LED power supplies, Cat. No. GEXLPS21, GEXNPS30-120, GEXNPS31-120 <br />1. This component has been judged on the basis of the required spacings in the Standard for Class 2 Power Units, UL 1310, <br />Fourth Edition, which would cover the component itself if submitted for Listing. <br />2.The supply terminals and connectors are suitable for factory pbring only of solid or tinned stranded No. 18 AWG conductors. <br />3.The equipment was submitted and tested for a maximum manufacturer's recommended ambient (Trnra) of 40 C. <br />4. Leakage current measurements shall be performed when more than four LED drivers are used in the equipment or when the <br />LED driver is used in combination with other equipment in the end-use product. <br />5. The drivers are intended for installation inside an electrital enclosure. <br />6. The ground connectipn is not suitable as the equipment ground for a sign. Separate provision for sign grounding must be <br />provided. <br />7. The drivers are suitable for dry location use only except the drivers Models GEXNPS30-120 and GEXLPS21 are suitable for <br />damp location use. <br />LED array drivers, Models GEXLPS21-U, GEPS12-60U, GE060/MV/\/12T12T1-A <br />1. These components have been judged on the basis of the required spacing in the Standard for Class 2 Power Units, UL 1310, <br />Fourth Edition, which would cover:the component itself if submitted for Listing. <br />2. The terminals and connectors afe suitable for factory wiring only of solid or tinned stranded No. 18 AWG conductors. <br />3. The equipment was submitted and tested for a maximum manufacturer's recommended ambient (Tmra) of 40°C. <br />4. The insulation system of;the main isolation transformer designated (T2) in these models is a Class 105(A) insulation system. <br />Unless the modules are mounted as specified in condition of acceptability number 7, a temperature test is required when these <br />models installed within an electrical enclosure or raceway. <br />5. The maximum measured leakage current of a single unit is 0.49 mA. Leakage current measurements shall be performed when <br />multiple LED drivers are used in the final equipment or when the LED driver is used in combination with other equipment in the <br />end-use product. <br />6. The unit is intended for installation inside an electrical enclosure. <br />7. The unit may be used within an electrical enclosure or raceway without temperature test provided they are mounted not closer <br />than 1 in. end to end or 4 in. side to side from adjacent LED power supplies. <br />8. The ground connection 'is not suitable as the equipment ground for a sign. Separate provision for sign grounding must be <br />provided. <br />LED power supplies, Model GEPS24-100U, GE100/MVA/24T1-A. <br />1. This component has been judged on the basis of the required spacing in the Standard for Class 2 Power Units, UL 1310, Fourth <br />Edition, which would cover the component itself if submitted for Listing. <br />2. The supplyterminals and connectors are suitable for factory wiring only of solid or tinned stranded No. 18 AWG conductors. <br />3. The equipment was submitted and tested for a maximum manufacturer's recommended ambient (Tmra) of 40 C. <br />4. This unit is provided with a Class 105(A) insulation system. A temperature test is requited when the unit is installed within an <br />electrical enclosure or raceway. <br />5. Leakage current measurements shall be performed when more than four LED drivers are used in the equipment or when the <br />LED driver is used in combination with other equipment in the end-use product. <br />6. The unit is intended for installation inside an electrical enclosure. <br />7. The unit may be used within an electrical enclosure or raceway Without temperature test provjded they are mounted not closer <br />than 1 in. end to end or 4 in. side to side from adjacent LED power supplies. <br />LED array drivers, Models GEPS 12-20, GEPS 24-20. <br />1. The maximum measured output voltage, current and power at the output of these models was found in compliance with the <br />limits for Class 2 output requirements. <br />2. The transformers of these units employ Class 105 insulation system. <br />3. These components were intended for use in indoor Dry and DAMP location only.