Laserfiche WebLink
R <br />F.C <br />PEND <br />GD <br />J <br />AT <br />T <br />I <br />C <br />W/H <br />DW <br />RE <br />F <br />Elec. <br />W <br />/ <br />D <br />GD <br />ATTIC R R <br />RR <br />R <br />RR <br />R <br />R <br />R <br />R <br />R <br />R R <br />R <br />R <br />RR <br />R <br />R <br />R <br />PEND <br />PEND <br />RR <br />RR <br />R <br />R <br />R <br />KITCHEN EXHAUST FAN MIN. 130 CFM FOR ELECTRICAL <br />(280 CFM FOR GAS) SHALL BE DUCTED TO OUTSIDE <br />THROUGH ROOF/EXTERIOR WALL <br />L.E.D. RECESSED LIGHT FIXTURE <br />CEILING MOUNTED LINEAR BOX 1X4 LIGHT FIXTURE <br />WALL AIR DIFFUSER <br />GF <br />C <br />I <br />110V DUPLEX OUTLET, ARC FAULT <br />CIRCUIT INTERRUPTER (ENTIRE CIRCUIT) <br />AF <br />C <br />I <br />SWITCH W/ MOTION SENSOR <br />(VACANCY SENSOR) <br />VS <br />2-WAY SWITCH2D <br />HB <br />3/4" HOSE BIBB WITH BACK-FLOW PREVENTOR <br />SMOKE DETECTOR HARDWIRED w/ <br />BATTERY BACK UP, PHOTOELECTRIC TYPE. <br />SD <br />CARBON MONOXIDE DETECTOR ALARM <br />HARDWIRED w/ BATTERY BACK UP, <br />PHOTOELECTRIC TYPE. <br />CD <br />VANITY WALL LIGHT <br />EXTERIOR WALL SCONCE LIGHT-HIGH EFFICACY <br />ELECTRICAL PANEL <br />ATTIC FURNACE <br />AC CONDENSER UNIT ON PAD <br />ELECTRIC VEHICLE CHARGER <br />MEDIA OUTLET <br />CEILING AIR DIFFUSER <br />EXHAUST FAN SHALL BE ENERGY STAR RATED. CEILING <br />MOUNTED LIGHT w/ VENT 50 CFM MIN. INTERMITTENT W/ <br />HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50%-80% <br />SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL <br />RESIDENCE IAQ FAN 45 CFM <br />PER T24 FOR SELECTION <br />110V DUPLEX OUTLET, GROUND FAULT CIRCUIT <br />INTERRUPT (ENTIRE CIRCUIT) <br />VS <br />CEILING MOUNTED HANGING LED LIGHT FIXTURE (PENDANT) <br />GARBAGE DISPOSAL <br />PC : PHOTO CELLW/P : WEATHER -RESISTANT <br />DIMMER SWITCH <br />D <br />J-BOX (CEILING FAN/LIGHT FIXTURE) <br />UNDER CABINET LIGHTING <br />DRYER EXHAUST <br />PUSH BUTTON <br />T THERMOSTAT <br />P PHOTO CELL <br />M <br />BROADBAND/MEDIA CENTERB/B <br />E <br />110V DUPLEX OUTLET, COMBINATION GROUND <br />FAULT CIRCUIT INTERRUPT AND ARC FAULT <br />CIRCUIT INTERRUPTER (ENTIRE CIRCUIT) <br />G/ <br />A <br />ATTIC ACCESS 24X30 <br />WALL MOUNTED A/C <br />OUTDOOR UNIT <br />WALL MOUNTED A/C <br />INDOOR UNIT <br />NEEA RATED HEATPUMP WATER HEATER PER T-24 <br />MODEL: PROPH50 T2 RH37515 (50 GAL, JA13) <br />WALL MOUNTED LIGHT <br />CHANDELIER LIGHT FIXTURE <br />2 <br />1. ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH NEC ARTICLE 210-52. <br />2. LIGHTING OUTLETS CONTROLLED BY A WALL SWITCH SHALL BE PROVIDED IN ACCORDANCE WITH NEC ARTICLE 210-70. <br />3. LIGHT FIXTURES INSTALLED IN CLOTHES CLOSET WILL COMPLY WITH NEC ARTICLE 410-8. <br />4. ELECTRICAL SERVICE SIZE: 200 AMPS, MIN. <br />5. ALL 120V SINGLE PHASE, 15 AND 20 AMP OUTLETS (RWCEPTACLE, LIGHTING, SMOKE DETECTORS, ETC.) SHALL BE PROTECTED BY <br />COMBINATION TYPE ARC-FAULT INTERRUPTER( CEC 210.12). <br />6. CONVENIENCE OUTLETS IN BATHROOMS, KITCHEN COUNTERTOPS, OUTDOORS, AND IN GARAGES AND BASEMENTS SHALL BE GFI <br />PROTECTED PER NEC ARICLE 210-8. <br />7. PROVIDE ACCESSIBLE JUNCTION BOX AND WRING FOR GROUNDING MAIN ELECTRICAL SERVICE TO REINFORCING BAR IN CONCRETE <br />FOOTING, PER ARTICLE 250.52-68 CEC 20' LONG #4 REBAR MIN. <br />8. ELECTRICAL OUTLET BOXES IN OPPOSITE FACES OF SEPARATION WALLS SHALL BE SEPARATED HORIZONTALLY BY 24". BACK AND <br />SIDES OF BOXES TO BE SEALED WITH 1/8" RESILIENT SEALANT AND BACKER WITH 2" MIN. MINERAL FIBER INSULATION. (TV, PHONE <br />AND INTERCOM OUTLETS MUST BE INSTALLED IN BOXES ACCORDINGLY) <br />9. RECESSED CAN LIGHT FIXTURES IN INSUTATED SPACES AER TO BE IC / AT RATED. <br />10. ELECTRIC UTILITY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION. <br />11. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION OF ADDITIONS > 50%. <br />12. FIELD INSPECTORS TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENT PRIOR TO CONCRETE REPLACEMENT. <br />13. MAINTAIN THREE FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO WALL ANY WALL SURFACE OR OBSTRUCTION. <br />14. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD.275. SOUND LEVEL NOT TO EXCEED 50 DBA (55 DBA <br />WITH TIMER, 65 DBA WITH TIMER AND NEIGHBOR"S CONSENT) PER SECTION 10.26.045 OF THE LOCATION OF MEASUREMENTS TO <br />BE AT FIVE (5) FEET ABOVE GRADE AT PROPERTY LINE. LOCATE EQUIPMENT IN EQUIPMENT WELL ON ROOF IF NECESSARY. <br />15. LAUNDRY AND BATHROOM EXHAUST FANS SHALL PROVIDE A MINIMUM OF 50 CFM. <br />16. PROVIDE COMBINATION SMOKE/ CARBON MONOXIDE DETECTORS IN EACH HALLWAY LEADING TO SLEEPING ROOMS, IN EACH <br />SLEEPING ROOM, AT THE TOP OF STAIRS, AND IN EACH STORY. SMOKE DETECTORS SHALL NOT BE LOCATED IN KITCHEN, GARAGE, <br />OR WITHIN 3 FEET OF DOORS TO KITCHEN OR BATHROOM OR SUPPLY AIR REGISTERS. DETECTORS HARD WIRED WITH BATTERY <br />BACK-UP. DETECTORS TO BE INTERCONNECTED TO SOUND AT THE SAME TIME. <br />17. ALL 125V,15A AND 20A RECEPTACLE OUTLETS SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES. <br />18. ANY FIXED APPLIANCE SUCH AS GARBAGE DISPOSER, DISHWASHER, CLOTHES WASHER, DRYER, BUILT-IN HEATERS, OR ANY <br />OTHER FIXED APPLIANCE WITH 1/4 HP MOTOR OR LARGER, SHALL BE ON A SEPARATE #12 AWG WIRE BRANCH 20 AMP CIRCUIT. <br />19. ALLPERMANENT INSTALLED LIGHTING, INCLUDING HALLWAYS, DINING ROOMS, BEDROOMS, FAMILY ROOMS, BEDROOMS, FAMILY ROOMS, AND <br />LIVING ROOMS MUST BE HIGH EFFICACY. <br />20. LIGHT FIXTURES IN BATHROOMS, GARAGES, LAUNDRY ROOM AND UTILITY ROOMS SHALL BE HIGH EFFICACY. AT LEAST ONE LUMINAIRE IN EACH OF <br />THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR. <br />21. RECESSED LIGHTS THAT ARE TO BE INSTALLED IN AN INSULATED CEILING OR CAVITY ARE REQUIRED TO HAVE A ZERO CLEARANCE INSULATION <br />COVER (IC): BE CERTIFIED THAT THEY ARE TIGHT; AND SEALED WITH A GASKET OR CAULK BETWEEN THE THE HOUSING AND THE CEILING. <br />22. ALL STAIRWAY SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS HAN 1 FOOT CANDLE (11 LUX). <br />23. EXTERIOR LIGHTING MOUNTED ON BUILDING TO BE HIGH EFFICACY AND CONTROLLED BY MANUAL ON/OFF SWITCH MOTION SENSOR WITHOUT <br />OVERRIDE OR BYPASS SWITCH THAT DISABLES MOTION SENSOR AND: <br />A. PHOTO-CONTROL NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES PHOTO-CONTROL <br />B. ASTRONOMICAL TIME CLOCK NOT HAVING OVERRIDE OR BYPASS SWITCH THAT DISABLES ASTRONOMICAL CLOCK <br />C. ENERGY MANAGEMENT CONTROL SYSTEM (EMC5) NOT HAVING OVERRIDE OR BYPASS SWITCH THAT ALLOWS LUMINAIRES TO BE ALWAYS ON <br />D. RATED FOR WET LOCATIONS <br />24. PROVIDE WHOLE HOUSE MECHANICAL VENTILATION PER ASHRAE STANDARD 62.1-2007 SECT. 4, WITH EXCEPTION THAT NATURAL VENTILATION <br />THROUGH DOORS AND WINDOWS IS NOT AN ACCEPTABLE ALTERNATIVE TO WHOLE HOUSE VENTILATION (BEES 152(A), EXCEPTION 5 TO SECTION, <br />MINIMUM REQUIRED RATE OF VENTILATION OF 1 CFM FOR EACH 100SF. OF CONDITIONED FLOOR AREA PLUS 7.5 CFM FOR EACH OCCUPANT (1 <br />OCCUPANT PER BEDROOM +1). VENTILATION TO BE PROVIDED BY EXHAUST AIR, SUPPLY AIR OF COMBINES EXHAUST AND SUPPLY AIR. <br />25. PROVIDE GFCI RECEPTACLES AT BATHROOMS, KITCHEN COUNTERTOP SURFACES,LAUNDRY /WET BAR AREA WITHIN 6FT FROM EDGE OF THE SINKS <br />(CEC 210-8) <br />26. SERVICE EQUIPMENT AND SUBPANELS SHALL HAVE A MIN 30”WIDE BY 36”DEEP CLEAR WORKSPACE. (CEC 110.26) <br />27. PROVIDE A LISTED 1-INCH RACEWAY TO ACCOMMODATE A DEDICATED 208/240-VOLT CIRCUIT FOR FUTURE ELECTRICAL VEHICLE (EV) CHARGER. <br />(CAL GREEN 4.106.4.1) <br />28. ALL RECEPTACLE OUTLETS ARE REQUIRED SHALL BE LISTED TAMPER RESISTANT (CEC 406.12 AND 250.52) <br />29. COMBINATION TYPE AFCI CIRCUIT BREAKERS ARE REQUIRED FOR ALL 120-VOLT SINGLE PHASE 15/20-AMP BRANCH CIRCUITS. EXCEPT FOR <br />BATHROOMS, GARAGES, AND OUTDOORS. (CEC 210.12) <br />30. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48'' <br />MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15'' MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH <br />FLOOR. <br />31. DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, <br />MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. <br />32. ROOMS OR OCCUPIED SPACES WITHIN RESIDENTIAL OCCUPANCIES, WHERE THE OCCUPANTS AREA NONTRANSIENT, SHALL BE DESIGNED TO HAVE <br />MECHANICAL VETILATION AND EXHAUST AIR IN ACCORDANCE WITH SECTION 405 (CMC, 2022) <br />01 <br />-A-20 <br />1 <br />3 <br />01-A-201 <br />6 <br />P <br />WP-WR <br />GFCI, 220V <br />AF <br />C <br />I <br />30A,240V,READY <br />G/A, W/P <br />W/P <br />SD <br />SD <br />SDCD <br />W/P <br />SDCD <br />AFCI <br />AFCI <br />AF <br />C <br />I <br />AFCI <br />AFCI <br />AF <br />C <br />I <br />P <br />39 39 <br />ADUADUADUADU----BED #2BED #2BED #2BED #2 <br />9' 0" CLG <br />WOOD <br />ADUADUADUADU----BED #1BED #1BED #1BED #1 <br />9' 0" CLG <br />WOOD <br />ADUADUADUADU----BATH#2BATH#2BATH#2BATH#2 <br />9' 0" CLG <br />TILE <br />ADUADUADUADU----HALLWAYHALLWAYHALLWAYHALLWAY <br />9' 0" CLG <br />WOOD <br />ADUADUADUADU----BATH#1BATH#1BATH#1BATH#1 <br />9' 0" CLG <br />TILE <br />LIVING + KITCHENLIVING + KITCHENLIVING + KITCHENLIVING + KITCHEN <br />9' 0" CLG <br />WOOD <br />AFCI <br />AFCI <br />AFCI <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AFCI <br />AFCI <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AFCI <br />AFCI <br />AFCI <br />AD <br />U <br />AD <br />U <br />AD <br />U <br />AD <br />U <br />---- <br />CL <br />O <br />S <br />E <br />T <br />CL <br />O <br />S <br />E <br />T <br />CL <br />O <br />S <br />E <br />T <br />CL <br />O <br />S <br />E <br />T <br />ADUADUADUADU----CLOSETCLOSETCLOSETCLOSET <br />50 <br />A <br />, <br />2 <br />4 <br />0 <br />V <br />, <br />R <br />E <br />A <br />D <br />Y <br />G/ <br />A <br />, <br /> <br />W <br />/ <br />P <br />30A,240V,READY <br />GFCI, W/P <br />30 <br />A <br />, <br />2 <br />4 <br />0 <br />V <br />, <br />R <br />E <br />A <br />D <br />Y <br />GF <br />C <br />I <br />, <br /> <br />W <br />/ <br />P <br />220V <br />G/A <br />G/A <br />+48" <br />G/A <br />+48" <br />G/ <br />A <br />+4 <br />8 <br />" <br />G/ <br />A <br />+4 <br />8 <br />" <br />G/ <br />A <br />+4 <br />8 <br />" <br />VS <br />VS <br />VS <br />VS <br />2DD <br />2D2D <br />2D <br />D <br />D <br />1.7 1.3 1.4 1.2 <br />52 <br />54 <br />55 <br />55 <br />51 <br />2D <br />2D <br />2D <br />2D <br />2D <br />2D <br />GF <br />C <br />I <br />GF <br />C <br />I <br />AFCI <br />P <br />P <br />P <br />39 <br />39 <br />39 <br />D <br />D <br />D <br />D <br />32 <br />32 <br />32 <br />P 39 <br />P 39 <br />M <br />33 <br />31 <br />2 <br />2 <br />2 <br />2 <br />D <br />XX DOOR TYPE, SEE SCHEDULE ON SHEET 01-A-202 <br />WINDOW TYPE, SEE SCHEDULE ON SHEET 01-A-202 <br />XX KEY NOTE PER SCHEDULE <br />FLOOR DEPRESSION <br />XX <br />LEGENDLEGENDLEGENDLEGEND <br />WALL TYPE, SEE SCHEDULE ON SHEET 01-A-202NWX <br />ALL SINGLEALL SINGLEALL SINGLEALL SINGLE ----FAMILY RESIDENCES THAT INCLUDE ONE OR TWO DWELLING UNITS SHALL MEET THE FOLLOWING: [150.0(S)]FAMILY RESIDENCES THAT INCLUDE ONE OR TWO DWELLING UNITS SHALL MEET THE FOLLOWING: [150.0(S)]FAMILY RESIDENCES THAT INCLUDE ONE OR TWO DWELLING UNITS SHALL MEET THE FOLLOWING: [150.0(S)]FAMILY RESIDENCES THAT INCLUDE ONE OR TWO DWELLING UNITS SHALL MEET THE FOLLOWING: [150.0(S)] <br />A.A.A.A.AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: <br />1. 1. ESS READY INTERCONNECTION EQUIPMENT WITH A MINIMUM BACKED-UP CAPACITY OF 60 AMPS AND A MINIMUM OF FOUR ESS-SUPPLIED BRANCH CIRCUITS; OR <br />2. A DEDICATED RACEWAY FROM THE MAIN SERVICE TO A PANELBOARD (SUBPANEL) THAT SUPPLIES THE BRANCH CIRCUITS IN SEC. 150.0(S)(2). ALL BRANCH CIRCUITS ARE <br />PERMITTED TO BE SUPPLIED BY THE MAIN SERVICE PANEL PRIOR TO THE INSTALLATION OF AN ESS. THE TRADE SIZE OF THE RACEWAY SHALL BE NOT LESS THAN 1 INCH. <br />THE PANELBOARD THAT SUPPLIES THE BRANCH CIRCUITS (SUBPANEL) MUST BE LABELED “SUBPANEL SHALL INCLUDE ALL BACKED-UP LOAD CIRCUITS.” <br />B. B. B. B. A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE IDENTIFIED AND HAVE THEIR SOURCE OF SUPPLY COLLOCATED AT A SINGLE PANELBOARD SUITABLE TO BE SUPPLIED BY THE <br />ESS. AT LEAST ONE CIRCUIT SHALL SUPPLY THE REFRIGERATOR, ONE LIGHTING CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS AND AT LEAST ONE CIRCUIT SHALL <br />SUPPLY A SLEEPING ROOM RECEPTACLE OUTLET. <br />C.C.C.C.THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING OF 225 AMPS. <br />D.D.D.D.SUFFICIENT SPACE SHALL BE RESERVED TO ALLOW FUTURE INSTALLATION OF A SYSTEM ISOLATION EQUIPMENT/ TRANSFER SWITCH WITHIN 3 FT.OF THE MAIN PANELBOARD. <br />RACEWAYS SHALL BE INSTALLED BETWEEN THE PANELBOARD AND THE SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH LOCATION TO ALLOW THE CONNECTION OF BACKUP <br />POWER SOURCE. <br />A. HEAT PUMP SPACE HEATER READY.A. HEAT PUMP SPACE HEATER READY.A. HEAT PUMP SPACE HEATER READY.A. HEAT PUMP SPACE HEATER READY. <br />SYSTEMS USING PROPANE FURNACE TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: <br />1. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FT. FROM THE FURNACE AND ACCESSIBLE TO THE FURNACE WITH NO OBSTRUCTIONS. THE <br />BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY”. <br />2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKERFOR A FUTURE HEAT PUMP <br />SPACE HEATER INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE.” <br />B. ELECTRIC COOKTOP READY.B. ELECTRIC COOKTOP READY.B. ELECTRIC COOKTOP READY.B. ELECTRIC COOKTOP READY. <br />SYSTEMS USING PROPANE COOKTOP TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: <br />1. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FT. FROM THE COOKTOP AND ACCESSIBLE TO THE COOKTOP WITH NO OBSTRUCTIONS. THE <br />BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 50 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V <br />READY”. <br />2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKERFOR A FUTURE ELECTRIC <br />COOKTOP INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE.” <br />C. ELECTRIC CLOTHES DRYER READY.C. ELECTRIC CLOTHES DRYER READY.C. ELECTRIC CLOTHES DRYER READY.C. ELECTRIC CLOTHES DRYER READY. <br />CLOTHES DRYER LOCATIONS WITH PROPANE PLUMBING TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: <br />1. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FT. FROM THE CLOTHES DRYER LOCATION AND ACCESSIBLE TO THE CLOTHES DRYER <br />LOCATION WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY.” <br />2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKERFOR A FUTURE ELECTRIC <br />CLOTHES DRYER INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE.” <br />2 <br />2025.03 <br />10.10.2025 <br />©2025Sheet No. <br />Rev. <br />Project No. <br />Date Print: <br />Design by <br />TRINH HA. <br />Date. <br />Pr <br />o <br />j <br />e <br />c <br />t <br />: <br />Description. <br />1.07.23.2025Correction 1st. <br />2.09.12.2025Correction 2nd. <br />05-E-001 <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br /> <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br /> <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br /> <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br /> <br />---- <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />Ad <br />d <br />r <br />e <br />s <br />s <br /> <br />M <br />a <br />i <br />n <br /> <br />H <br />o <br />u <br />s <br />e <br />: <br /> <br />4 <br />2 <br />1 <br /> <br />S <br /> <br />C <br />e <br />n <br />t <br />e <br />r <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />92 <br />7 <br />0 <br />3 <br />Ad <br />d <br />r <br />e <br />s <br />s <br /> <br />D <br />e <br />t <br />a <br />c <br />h <br />e <br />d <br /> <br />A <br />D <br />U <br />: <br /> <br />4 <br />2 <br />3 <br /> <br />S <br /> <br />C <br />e <br />n <br />t <br />e <br />r <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br />9 <br />2 <br />7 <br />0 <br />3 <br />PROPOSED_ADU <br />CEILING ELECTRICAL <br />PLAN <br />ELECTRICAL LEGENDELECTRICAL LEGENDELECTRICAL LEGENDELECTRICAL LEGEND <br />ELEC. PLAN KEYNOTEELEC. PLAN KEYNOTEELEC. PLAN KEYNOTEELEC. PLAN KEYNOTE <br />ELECTRICAL NOTESELECTRICAL NOTESELECTRICAL NOTESELECTRICAL NOTES <br />1.2 (N) ELECTRICAL PANEL FOR ADU 200 AMP, WITH A 225A BUS BAR <br />1.3 "(N) 60 AMP SUBPANEL FOR ADU ESS SYSTEM" <br />1.4 (N) ELECTRICAL METER FOR ADU 200 AMP <br />1.7 (N) ELECTRICAL METER FOR MAINHOUSE 200 AMP, RELOCATION <br />31 (N) DUCTLESS MULTI-SPLIT SYSTEM AC. PER T-24 <br />32 (N) WALL MOUNTED AC INDOOR UNIT PER T-24 <br />33 (N) HEAT PUMP WATER HEATERS PER T-24, MODEL: PROPH50 T2 RH37515 (50 GAL, JA13) , EQUIPMENT CABINET TO BE PAINTED TO MATCH THE ADU EXTERIOR <br />MATERIALS <br />39 PHOTOCELL CONTROL / MOTION SENSOR <br />51 (N) 36" COOK-TOP. PROVIDE EXHAUST HOOD WITH LIGHT AND FAN VENT TO OUTSIDE AIR (280 CFM) WITH 8" DUCT. VERIFY DIMENSIONS AND POWER REQUIREMENTS <br />WITH MANUFACTURER'S SPECIFICATIONS. <br />52 THIS SWITCH CONTROLS THE INDOOR AIR QUALITY VENTILATION FOR THE HOME. LEAVE SWITCH IN THE 'ON' POSITION AT ALL TIMES UNLESS THE OUTDOOR AIR <br />QUALITY IS VERYPOOR."[150.0(O)J] <br />54 "MIN. 4"" DIA. TO THE OUTSIDE, EQUIPPED WITH A BACK DRAFT DAMPER. DUCT LENGTH OR SIZES AS PERMITTED OR REQUIRED BY MANUFACTURERS INSTALLATIONS <br />AND APPROVED BY THE BUILDING OFFICIAL (EXHAUST THROUGH EXTERIOR WALL/ROOF)" <br />55 "EXHAUST FAN FOR BATHROOM SHALL BE ENERGY STAR RATED. CEILING MOUNTED LIGHT W/ VENT 50CFM MIN. INTERMITTENT W/HUMIDITY CONTROL PER CMC <br />402.5, BETWEEN 50-80% SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL" <br />1/4" = 1'-0"1PROPOSED- ADU CEILING ELECTRICAL FLOOR <br />ELECTRICELECTRICELECTRICELECTRIC----READY REQUIREMENTSREADY REQUIREMENTSREADY REQUIREMENTSREADY REQUIREMENTS