R
<br />F.C
<br />PEND
<br />GD
<br />J
<br />AT
<br />T
<br />I
<br />C
<br />W/H
<br />DW
<br />RE
<br />F
<br />Elec.
<br />W
<br />/
<br />D
<br />GD
<br />ATTIC R R
<br />RR
<br />R
<br />RR
<br />R
<br />R
<br />R
<br />R
<br />R
<br />R R
<br />R
<br />R
<br />RR
<br />R
<br />R
<br />R
<br />PEND
<br />PEND
<br />RR
<br />RR
<br />R
<br />R
<br />R
<br />KITCHEN EXHAUST FAN MIN. 130 CFM FOR ELECTRICAL
<br />(280 CFM FOR GAS) SHALL BE DUCTED TO OUTSIDE
<br />THROUGH ROOF/EXTERIOR WALL
<br />L.E.D. RECESSED LIGHT FIXTURE
<br />CEILING MOUNTED LINEAR BOX 1X4 LIGHT FIXTURE
<br />WALL AIR DIFFUSER
<br />GF
<br />C
<br />I
<br />110V DUPLEX OUTLET, ARC FAULT
<br />CIRCUIT INTERRUPTER (ENTIRE CIRCUIT)
<br />AF
<br />C
<br />I
<br />SWITCH W/ MOTION SENSOR
<br />(VACANCY SENSOR)
<br />VS
<br />2-WAY SWITCH2D
<br />HB
<br />3/4" HOSE BIBB WITH BACK-FLOW PREVENTOR
<br />SMOKE DETECTOR HARDWIRED w/
<br />BATTERY BACK UP, PHOTOELECTRIC TYPE.
<br />SD
<br />CARBON MONOXIDE DETECTOR ALARM
<br />HARDWIRED w/ BATTERY BACK UP,
<br />PHOTOELECTRIC TYPE.
<br />CD
<br />VANITY WALL LIGHT
<br />EXTERIOR WALL SCONCE LIGHT-HIGH EFFICACY
<br />ELECTRICAL PANEL
<br />ATTIC FURNACE
<br />AC CONDENSER UNIT ON PAD
<br />ELECTRIC VEHICLE CHARGER
<br />MEDIA OUTLET
<br />CEILING AIR DIFFUSER
<br />EXHAUST FAN SHALL BE ENERGY STAR RATED. CEILING
<br />MOUNTED LIGHT w/ VENT 50 CFM MIN. INTERMITTENT W/
<br />HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50%-80%
<br />SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL
<br />RESIDENCE IAQ FAN 45 CFM
<br />PER T24 FOR SELECTION
<br />110V DUPLEX OUTLET, GROUND FAULT CIRCUIT
<br />INTERRUPT (ENTIRE CIRCUIT)
<br />VS
<br />CEILING MOUNTED HANGING LED LIGHT FIXTURE (PENDANT)
<br />GARBAGE DISPOSAL
<br />PC : PHOTO CELLW/P : WEATHER -RESISTANT
<br />DIMMER SWITCH
<br />D
<br />J-BOX (CEILING FAN/LIGHT FIXTURE)
<br />UNDER CABINET LIGHTING
<br />DRYER EXHAUST
<br />PUSH BUTTON
<br />T THERMOSTAT
<br />P PHOTO CELL
<br />M
<br />BROADBAND/MEDIA CENTERB/B
<br />E
<br />110V DUPLEX OUTLET, COMBINATION GROUND
<br />FAULT CIRCUIT INTERRUPT AND ARC FAULT
<br />CIRCUIT INTERRUPTER (ENTIRE CIRCUIT)
<br />G/
<br />A
<br />ATTIC ACCESS 24X30
<br />WALL MOUNTED A/C
<br />OUTDOOR UNIT
<br />WALL MOUNTED A/C
<br />INDOOR UNIT
<br />NEEA RATED HEATPUMP WATER HEATER PER T-24
<br />MODEL: PROPH50 T2 RH37515 (50 GAL, JA13)
<br />WALL MOUNTED LIGHT
<br />CHANDELIER LIGHT FIXTURE
<br />2
<br />1. ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH NEC ARTICLE 210-52.
<br />2. LIGHTING OUTLETS CONTROLLED BY A WALL SWITCH SHALL BE PROVIDED IN ACCORDANCE WITH NEC ARTICLE 210-70.
<br />3. LIGHT FIXTURES INSTALLED IN CLOTHES CLOSET WILL COMPLY WITH NEC ARTICLE 410-8.
<br />4. ELECTRICAL SERVICE SIZE: 200 AMPS, MIN.
<br />5. ALL 120V SINGLE PHASE, 15 AND 20 AMP OUTLETS (RWCEPTACLE, LIGHTING, SMOKE DETECTORS, ETC.) SHALL BE PROTECTED BY
<br />COMBINATION TYPE ARC-FAULT INTERRUPTER( CEC 210.12).
<br />6. CONVENIENCE OUTLETS IN BATHROOMS, KITCHEN COUNTERTOPS, OUTDOORS, AND IN GARAGES AND BASEMENTS SHALL BE GFI
<br />PROTECTED PER NEC ARICLE 210-8.
<br />7. PROVIDE ACCESSIBLE JUNCTION BOX AND WRING FOR GROUNDING MAIN ELECTRICAL SERVICE TO REINFORCING BAR IN CONCRETE
<br />FOOTING, PER ARTICLE 250.52-68 CEC 20' LONG #4 REBAR MIN.
<br />8. ELECTRICAL OUTLET BOXES IN OPPOSITE FACES OF SEPARATION WALLS SHALL BE SEPARATED HORIZONTALLY BY 24". BACK AND
<br />SIDES OF BOXES TO BE SEALED WITH 1/8" RESILIENT SEALANT AND BACKER WITH 2" MIN. MINERAL FIBER INSULATION. (TV, PHONE
<br />AND INTERCOM OUTLETS MUST BE INSTALLED IN BOXES ACCORDINGLY)
<br />9. RECESSED CAN LIGHT FIXTURES IN INSUTATED SPACES AER TO BE IC / AT RATED.
<br />10. ELECTRIC UTILITY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION.
<br />11. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION OF ADDITIONS > 50%.
<br />12. FIELD INSPECTORS TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENT PRIOR TO CONCRETE REPLACEMENT.
<br />13. MAINTAIN THREE FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO WALL ANY WALL SURFACE OR OBSTRUCTION.
<br />14. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD.275. SOUND LEVEL NOT TO EXCEED 50 DBA (55 DBA
<br />WITH TIMER, 65 DBA WITH TIMER AND NEIGHBOR"S CONSENT) PER SECTION 10.26.045 OF THE LOCATION OF MEASUREMENTS TO
<br />BE AT FIVE (5) FEET ABOVE GRADE AT PROPERTY LINE. LOCATE EQUIPMENT IN EQUIPMENT WELL ON ROOF IF NECESSARY.
<br />15. LAUNDRY AND BATHROOM EXHAUST FANS SHALL PROVIDE A MINIMUM OF 50 CFM.
<br />16. PROVIDE COMBINATION SMOKE/ CARBON MONOXIDE DETECTORS IN EACH HALLWAY LEADING TO SLEEPING ROOMS, IN EACH
<br />SLEEPING ROOM, AT THE TOP OF STAIRS, AND IN EACH STORY. SMOKE DETECTORS SHALL NOT BE LOCATED IN KITCHEN, GARAGE,
<br />OR WITHIN 3 FEET OF DOORS TO KITCHEN OR BATHROOM OR SUPPLY AIR REGISTERS. DETECTORS HARD WIRED WITH BATTERY
<br />BACK-UP. DETECTORS TO BE INTERCONNECTED TO SOUND AT THE SAME TIME.
<br />17. ALL 125V,15A AND 20A RECEPTACLE OUTLETS SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES.
<br />18. ANY FIXED APPLIANCE SUCH AS GARBAGE DISPOSER, DISHWASHER, CLOTHES WASHER, DRYER, BUILT-IN HEATERS, OR ANY
<br />OTHER FIXED APPLIANCE WITH 1/4 HP MOTOR OR LARGER, SHALL BE ON A SEPARATE #12 AWG WIRE BRANCH 20 AMP CIRCUIT.
<br />19. ALLPERMANENT INSTALLED LIGHTING, INCLUDING HALLWAYS, DINING ROOMS, BEDROOMS, FAMILY ROOMS, BEDROOMS, FAMILY ROOMS, AND
<br />LIVING ROOMS MUST BE HIGH EFFICACY.
<br />20. LIGHT FIXTURES IN BATHROOMS, GARAGES, LAUNDRY ROOM AND UTILITY ROOMS SHALL BE HIGH EFFICACY. AT LEAST ONE LUMINAIRE IN EACH OF
<br />THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR.
<br />21. RECESSED LIGHTS THAT ARE TO BE INSTALLED IN AN INSULATED CEILING OR CAVITY ARE REQUIRED TO HAVE A ZERO CLEARANCE INSULATION
<br />COVER (IC): BE CERTIFIED THAT THEY ARE TIGHT; AND SEALED WITH A GASKET OR CAULK BETWEEN THE THE HOUSING AND THE CEILING.
<br />22. ALL STAIRWAY SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS HAN 1 FOOT CANDLE (11 LUX).
<br />23. EXTERIOR LIGHTING MOUNTED ON BUILDING TO BE HIGH EFFICACY AND CONTROLLED BY MANUAL ON/OFF SWITCH MOTION SENSOR WITHOUT
<br />OVERRIDE OR BYPASS SWITCH THAT DISABLES MOTION SENSOR AND:
<br />A. PHOTO-CONTROL NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES PHOTO-CONTROL
<br />B. ASTRONOMICAL TIME CLOCK NOT HAVING OVERRIDE OR BYPASS SWITCH THAT DISABLES ASTRONOMICAL CLOCK
<br />C. ENERGY MANAGEMENT CONTROL SYSTEM (EMC5) NOT HAVING OVERRIDE OR BYPASS SWITCH THAT ALLOWS LUMINAIRES TO BE ALWAYS ON
<br />D. RATED FOR WET LOCATIONS
<br />24. PROVIDE WHOLE HOUSE MECHANICAL VENTILATION PER ASHRAE STANDARD 62.1-2007 SECT. 4, WITH EXCEPTION THAT NATURAL VENTILATION
<br />THROUGH DOORS AND WINDOWS IS NOT AN ACCEPTABLE ALTERNATIVE TO WHOLE HOUSE VENTILATION (BEES 152(A), EXCEPTION 5 TO SECTION,
<br />MINIMUM REQUIRED RATE OF VENTILATION OF 1 CFM FOR EACH 100SF. OF CONDITIONED FLOOR AREA PLUS 7.5 CFM FOR EACH OCCUPANT (1
<br />OCCUPANT PER BEDROOM +1). VENTILATION TO BE PROVIDED BY EXHAUST AIR, SUPPLY AIR OF COMBINES EXHAUST AND SUPPLY AIR.
<br />25. PROVIDE GFCI RECEPTACLES AT BATHROOMS, KITCHEN COUNTERTOP SURFACES,LAUNDRY /WET BAR AREA WITHIN 6FT FROM EDGE OF THE SINKS
<br />(CEC 210-8)
<br />26. SERVICE EQUIPMENT AND SUBPANELS SHALL HAVE A MIN 30”WIDE BY 36”DEEP CLEAR WORKSPACE. (CEC 110.26)
<br />27. PROVIDE A LISTED 1-INCH RACEWAY TO ACCOMMODATE A DEDICATED 208/240-VOLT CIRCUIT FOR FUTURE ELECTRICAL VEHICLE (EV) CHARGER.
<br />(CAL GREEN 4.106.4.1)
<br />28. ALL RECEPTACLE OUTLETS ARE REQUIRED SHALL BE LISTED TAMPER RESISTANT (CEC 406.12 AND 250.52)
<br />29. COMBINATION TYPE AFCI CIRCUIT BREAKERS ARE REQUIRED FOR ALL 120-VOLT SINGLE PHASE 15/20-AMP BRANCH CIRCUITS. EXCEPT FOR
<br />BATHROOMS, GARAGES, AND OUTDOORS. (CEC 210.12)
<br />30. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48''
<br />MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15'' MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH
<br />FLOOR.
<br />31. DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING,
<br />MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY.
<br />32. ROOMS OR OCCUPIED SPACES WITHIN RESIDENTIAL OCCUPANCIES, WHERE THE OCCUPANTS AREA NONTRANSIENT, SHALL BE DESIGNED TO HAVE
<br />MECHANICAL VETILATION AND EXHAUST AIR IN ACCORDANCE WITH SECTION 405 (CMC, 2022)
<br />01
<br />-A-20
<br />1
<br />3
<br />01-A-201
<br />6
<br />P
<br />WP-WR
<br />GFCI, 220V
<br />AF
<br />C
<br />I
<br />30A,240V,READY
<br />G/A, W/P
<br />W/P
<br />SD
<br />SD
<br />SDCD
<br />W/P
<br />SDCD
<br />AFCI
<br />AFCI
<br />AF
<br />C
<br />I
<br />AFCI
<br />AFCI
<br />AF
<br />C
<br />I
<br />P
<br />39 39
<br />ADUADUADUADU----BED #2BED #2BED #2BED #2
<br />9' 0" CLG
<br />WOOD
<br />ADUADUADUADU----BED #1BED #1BED #1BED #1
<br />9' 0" CLG
<br />WOOD
<br />ADUADUADUADU----BATH#2BATH#2BATH#2BATH#2
<br />9' 0" CLG
<br />TILE
<br />ADUADUADUADU----HALLWAYHALLWAYHALLWAYHALLWAY
<br />9' 0" CLG
<br />WOOD
<br />ADUADUADUADU----BATH#1BATH#1BATH#1BATH#1
<br />9' 0" CLG
<br />TILE
<br />LIVING + KITCHENLIVING + KITCHENLIVING + KITCHENLIVING + KITCHEN
<br />9' 0" CLG
<br />WOOD
<br />AFCI
<br />AFCI
<br />AFCI
<br />AF
<br />C
<br />I
<br />AF
<br />C
<br />I
<br />AFCI
<br />AFCI
<br />AF
<br />C
<br />I
<br />AF
<br />C
<br />I
<br />AF
<br />C
<br />I
<br />AF
<br />C
<br />I
<br />AFCI
<br />AFCI
<br />AFCI
<br />AD
<br />U
<br />AD
<br />U
<br />AD
<br />U
<br />AD
<br />U
<br />----
<br />CL
<br />O
<br />S
<br />E
<br />T
<br />CL
<br />O
<br />S
<br />E
<br />T
<br />CL
<br />O
<br />S
<br />E
<br />T
<br />CL
<br />O
<br />S
<br />E
<br />T
<br />ADUADUADUADU----CLOSETCLOSETCLOSETCLOSET
<br />50
<br />A
<br />,
<br />2
<br />4
<br />0
<br />V
<br />,
<br />R
<br />E
<br />A
<br />D
<br />Y
<br />G/
<br />A
<br />,
<br />
<br />W
<br />/
<br />P
<br />30A,240V,READY
<br />GFCI, W/P
<br />30
<br />A
<br />,
<br />2
<br />4
<br />0
<br />V
<br />,
<br />R
<br />E
<br />A
<br />D
<br />Y
<br />GF
<br />C
<br />I
<br />,
<br />
<br />W
<br />/
<br />P
<br />220V
<br />G/A
<br />G/A
<br />+48"
<br />G/A
<br />+48"
<br />G/
<br />A
<br />+4
<br />8
<br />"
<br />G/
<br />A
<br />+4
<br />8
<br />"
<br />G/
<br />A
<br />+4
<br />8
<br />"
<br />VS
<br />VS
<br />VS
<br />VS
<br />2DD
<br />2D2D
<br />2D
<br />D
<br />D
<br />1.7 1.3 1.4 1.2
<br />52
<br />54
<br />55
<br />55
<br />51
<br />2D
<br />2D
<br />2D
<br />2D
<br />2D
<br />2D
<br />GF
<br />C
<br />I
<br />GF
<br />C
<br />I
<br />AFCI
<br />P
<br />P
<br />P
<br />39
<br />39
<br />39
<br />D
<br />D
<br />D
<br />D
<br />32
<br />32
<br />32
<br />P 39
<br />P 39
<br />M
<br />33
<br />31
<br />2
<br />2
<br />2
<br />2
<br />D
<br />XX DOOR TYPE, SEE SCHEDULE ON SHEET 01-A-202
<br />WINDOW TYPE, SEE SCHEDULE ON SHEET 01-A-202
<br />XX KEY NOTE PER SCHEDULE
<br />FLOOR DEPRESSION
<br />XX
<br />LEGENDLEGENDLEGENDLEGEND
<br />WALL TYPE, SEE SCHEDULE ON SHEET 01-A-202NWX
<br />ALL SINGLEALL SINGLEALL SINGLEALL SINGLE ----FAMILY RESIDENCES THAT INCLUDE ONE OR TWO DWELLING UNITS SHALL MEET THE FOLLOWING: [150.0(S)]FAMILY RESIDENCES THAT INCLUDE ONE OR TWO DWELLING UNITS SHALL MEET THE FOLLOWING: [150.0(S)]FAMILY RESIDENCES THAT INCLUDE ONE OR TWO DWELLING UNITS SHALL MEET THE FOLLOWING: [150.0(S)]FAMILY RESIDENCES THAT INCLUDE ONE OR TWO DWELLING UNITS SHALL MEET THE FOLLOWING: [150.0(S)]
<br />A.A.A.A.AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED:
<br />1. 1. ESS READY INTERCONNECTION EQUIPMENT WITH A MINIMUM BACKED-UP CAPACITY OF 60 AMPS AND A MINIMUM OF FOUR ESS-SUPPLIED BRANCH CIRCUITS; OR
<br />2. A DEDICATED RACEWAY FROM THE MAIN SERVICE TO A PANELBOARD (SUBPANEL) THAT SUPPLIES THE BRANCH CIRCUITS IN SEC. 150.0(S)(2). ALL BRANCH CIRCUITS ARE
<br />PERMITTED TO BE SUPPLIED BY THE MAIN SERVICE PANEL PRIOR TO THE INSTALLATION OF AN ESS. THE TRADE SIZE OF THE RACEWAY SHALL BE NOT LESS THAN 1 INCH.
<br />THE PANELBOARD THAT SUPPLIES THE BRANCH CIRCUITS (SUBPANEL) MUST BE LABELED “SUBPANEL SHALL INCLUDE ALL BACKED-UP LOAD CIRCUITS.”
<br />B. B. B. B. A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE IDENTIFIED AND HAVE THEIR SOURCE OF SUPPLY COLLOCATED AT A SINGLE PANELBOARD SUITABLE TO BE SUPPLIED BY THE
<br />ESS. AT LEAST ONE CIRCUIT SHALL SUPPLY THE REFRIGERATOR, ONE LIGHTING CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS AND AT LEAST ONE CIRCUIT SHALL
<br />SUPPLY A SLEEPING ROOM RECEPTACLE OUTLET.
<br />C.C.C.C.THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING OF 225 AMPS.
<br />D.D.D.D.SUFFICIENT SPACE SHALL BE RESERVED TO ALLOW FUTURE INSTALLATION OF A SYSTEM ISOLATION EQUIPMENT/ TRANSFER SWITCH WITHIN 3 FT.OF THE MAIN PANELBOARD.
<br />RACEWAYS SHALL BE INSTALLED BETWEEN THE PANELBOARD AND THE SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH LOCATION TO ALLOW THE CONNECTION OF BACKUP
<br />POWER SOURCE.
<br />A. HEAT PUMP SPACE HEATER READY.A. HEAT PUMP SPACE HEATER READY.A. HEAT PUMP SPACE HEATER READY.A. HEAT PUMP SPACE HEATER READY.
<br />SYSTEMS USING PROPANE FURNACE TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING:
<br />1. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FT. FROM THE FURNACE AND ACCESSIBLE TO THE FURNACE WITH NO OBSTRUCTIONS. THE
<br />BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY”.
<br />2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKERFOR A FUTURE HEAT PUMP
<br />SPACE HEATER INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE.”
<br />B. ELECTRIC COOKTOP READY.B. ELECTRIC COOKTOP READY.B. ELECTRIC COOKTOP READY.B. ELECTRIC COOKTOP READY.
<br />SYSTEMS USING PROPANE COOKTOP TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING:
<br />1. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FT. FROM THE COOKTOP AND ACCESSIBLE TO THE COOKTOP WITH NO OBSTRUCTIONS. THE
<br />BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 50 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V
<br />READY”.
<br />2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKERFOR A FUTURE ELECTRIC
<br />COOKTOP INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE.”
<br />C. ELECTRIC CLOTHES DRYER READY.C. ELECTRIC CLOTHES DRYER READY.C. ELECTRIC CLOTHES DRYER READY.C. ELECTRIC CLOTHES DRYER READY.
<br />CLOTHES DRYER LOCATIONS WITH PROPANE PLUMBING TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING:
<br />1. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FT. FROM THE CLOTHES DRYER LOCATION AND ACCESSIBLE TO THE CLOTHES DRYER
<br />LOCATION WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY.”
<br />2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKERFOR A FUTURE ELECTRIC
<br />CLOTHES DRYER INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE.”
<br />2
<br />2025.03
<br />10.10.2025
<br />©2025Sheet No.
<br />Rev.
<br />Project No.
<br />Date Print:
<br />Design by
<br />TRINH HA.
<br />Date.
<br />Pr
<br />o
<br />j
<br />e
<br />c
<br />t
<br />:
<br />Description.
<br />1.07.23.2025Correction 1st.
<br />2.09.12.2025Correction 2nd.
<br />05-E-001
<br />CE
<br />N
<br />T
<br />E
<br />R
<br />
<br />S
<br />T
<br />
<br />CE
<br />N
<br />T
<br />E
<br />R
<br />
<br />S
<br />T
<br />
<br />CE
<br />N
<br />T
<br />E
<br />R
<br />
<br />S
<br />T
<br />
<br />CE
<br />N
<br />T
<br />E
<br />R
<br />
<br />S
<br />T
<br />
<br />----
<br />RE
<br />S
<br />I
<br />D
<br />E
<br />N
<br />C
<br />E
<br />RE
<br />S
<br />I
<br />D
<br />E
<br />N
<br />C
<br />E
<br />RE
<br />S
<br />I
<br />D
<br />E
<br />N
<br />C
<br />E
<br />RE
<br />S
<br />I
<br />D
<br />E
<br />N
<br />C
<br />E
<br />Ad
<br />d
<br />r
<br />e
<br />s
<br />s
<br />
<br />M
<br />a
<br />i
<br />n
<br />
<br />H
<br />o
<br />u
<br />s
<br />e
<br />:
<br />
<br />4
<br />2
<br />1
<br />
<br />S
<br />
<br />C
<br />e
<br />n
<br />t
<br />e
<br />r
<br />
<br />S
<br />t
<br />,
<br />
<br />S
<br />a
<br />n
<br />t
<br />a
<br />
<br />A
<br />n
<br />a
<br />,
<br />
<br />C
<br />A
<br />
<br />92
<br />7
<br />0
<br />3
<br />Ad
<br />d
<br />r
<br />e
<br />s
<br />s
<br />
<br />D
<br />e
<br />t
<br />a
<br />c
<br />h
<br />e
<br />d
<br />
<br />A
<br />D
<br />U
<br />:
<br />
<br />4
<br />2
<br />3
<br />
<br />S
<br />
<br />C
<br />e
<br />n
<br />t
<br />e
<br />r
<br />
<br />S
<br />t
<br />,
<br />
<br />S
<br />a
<br />n
<br />t
<br />a
<br />
<br />A
<br />n
<br />a
<br />,
<br />
<br />C
<br />A
<br />9
<br />2
<br />7
<br />0
<br />3
<br />PROPOSED_ADU
<br />CEILING ELECTRICAL
<br />PLAN
<br />ELECTRICAL LEGENDELECTRICAL LEGENDELECTRICAL LEGENDELECTRICAL LEGEND
<br />ELEC. PLAN KEYNOTEELEC. PLAN KEYNOTEELEC. PLAN KEYNOTEELEC. PLAN KEYNOTE
<br />ELECTRICAL NOTESELECTRICAL NOTESELECTRICAL NOTESELECTRICAL NOTES
<br />1.2 (N) ELECTRICAL PANEL FOR ADU 200 AMP, WITH A 225A BUS BAR
<br />1.3 "(N) 60 AMP SUBPANEL FOR ADU ESS SYSTEM"
<br />1.4 (N) ELECTRICAL METER FOR ADU 200 AMP
<br />1.7 (N) ELECTRICAL METER FOR MAINHOUSE 200 AMP, RELOCATION
<br />31 (N) DUCTLESS MULTI-SPLIT SYSTEM AC. PER T-24
<br />32 (N) WALL MOUNTED AC INDOOR UNIT PER T-24
<br />33 (N) HEAT PUMP WATER HEATERS PER T-24, MODEL: PROPH50 T2 RH37515 (50 GAL, JA13) , EQUIPMENT CABINET TO BE PAINTED TO MATCH THE ADU EXTERIOR
<br />MATERIALS
<br />39 PHOTOCELL CONTROL / MOTION SENSOR
<br />51 (N) 36" COOK-TOP. PROVIDE EXHAUST HOOD WITH LIGHT AND FAN VENT TO OUTSIDE AIR (280 CFM) WITH 8" DUCT. VERIFY DIMENSIONS AND POWER REQUIREMENTS
<br />WITH MANUFACTURER'S SPECIFICATIONS.
<br />52 THIS SWITCH CONTROLS THE INDOOR AIR QUALITY VENTILATION FOR THE HOME. LEAVE SWITCH IN THE 'ON' POSITION AT ALL TIMES UNLESS THE OUTDOOR AIR
<br />QUALITY IS VERYPOOR."[150.0(O)J]
<br />54 "MIN. 4"" DIA. TO THE OUTSIDE, EQUIPPED WITH A BACK DRAFT DAMPER. DUCT LENGTH OR SIZES AS PERMITTED OR REQUIRED BY MANUFACTURERS INSTALLATIONS
<br />AND APPROVED BY THE BUILDING OFFICIAL (EXHAUST THROUGH EXTERIOR WALL/ROOF)"
<br />55 "EXHAUST FAN FOR BATHROOM SHALL BE ENERGY STAR RATED. CEILING MOUNTED LIGHT W/ VENT 50CFM MIN. INTERMITTENT W/HUMIDITY CONTROL PER CMC
<br />402.5, BETWEEN 50-80% SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL"
<br />1/4" = 1'-0"1PROPOSED- ADU CEILING ELECTRICAL FLOOR
<br />ELECTRICELECTRICELECTRICELECTRIC----READY REQUIREMENTSREADY REQUIREMENTSREADY REQUIREMENTSREADY REQUIREMENTS
|