Laserfiche WebLink
F.C <br />W/H <br />EP <br />GD <br />AT <br />T <br />I <br />C <br />DW <br />RE <br />F <br />Elec. <br />W <br />/ <br />D <br />GD <br />ATTIC <br />1. PROVIDE HOUSE STREET NUMBER VISIBLE AND LEGIBLE FROM STREET <br />2. PROVIDE MIN. 2% SLOPE AT FLAT ROOF AND DECK. <br />3. FINISH END WALLS OF CABINETS FLANKING OPENING TO MATCH CABINET FACE. PRIME & <br />PAINT EXPOSED GYP. BD. WALL TO MATCH WALLS. INSTALL MATCHING BASE BD. <br />4. EXTEND FLOORING UNDER APPLIANCES RESTING ON FLOOR. <br />5. SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUB WITH SHOWER HEADS SHALL BE <br />FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 6 FEET <br />ABOVE FLOOR. <br />6. WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED EQUAL TO 70 INCHES ABOVE <br />DRAIN INLET AT SHOWERS OR TUB WITH SHOWERS. PROVIDE APPROVED SHATTER-RESISTANT <br />MATERIALS FOR SHOWER ENCLOSURE AND WINDOWS IF SILL IS LESS THAN 5'-0" ABOVE TUB <br />OR SHOWER FLOOR. <br />7. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL, UNO. <br />8. CEILING HEIGHTS INDICATED ARE MEASURED FROM FINISH FLOOR TO BOTTOM OF CEILING <br />FINISH. <br />9. SMOKE DETECTORS WILL BE PROVIDED PER CHAPTER 3 CRC. THE SMOKE DETECTOR WILL BE <br />HARD WIRED WITH BATTERY BACK-UP AND LOCATED (1) IN EACH BEDROOM, HALLWAYS <br />OUTSIDE BEDROOMS, AND ON EACH STORY. SMOKE DETECTOR ALARM SOUND MUST BE <br />AUDIBLE IN SLEEPING AREAS WHICH MAY REQUIRE INTERCONNECTED SMOKE DETECTORS <br />WITHIN THE UNIT. SEE UTILITY PLANS FOR LOCATIONS. INSTALL AND LOCATE PER MFGR. <br />LISTED REQUIREMENTS. <br />10. SMOKE DETECTOR SHALL BE INTERCONNECTED SUCH THAT THE ACTIVATION OF ONE ALARM <br />WILL ACTIVATE ALL ALARMS. <br />11. SMOKE ALARM AND DETECTORS WILL BE INSTALLED AND MAINTAINED ACCORDING TO <br />MANUFACTURER'S INSTRUCTIONS. <br />12. PROVIDE CARBON MONOXIDE DETECTOR ALARMS ON CEILINGS OR WALLS OUTSIDE SLEEPING <br />ROOMS PER CHAPTER 3 CRC. A DETECTOR IS REQUIRED ON EACH FLOOR <br />13. BATHROOM FANS MUST BE ENERGY STAR W/ HUMIDISTAT CONTROLLER AND MUST BE <br />DUCTED TO THE EXTERIOR OF THE BUILDING <br />14. ALL NEW WINDOWS TO BE DUAL PANES TO MEET CURRENT ENERGY STANDARD <br />REQUIREMENTS. <br />15. ALL WALL ARE 2X4 @16" O.C. U.N.O. <br />16. PROVIDE BACKING FOR ALL ACCESSORIES, FIXTURES AND WINDOW COVERINGS. <br />17. NO HEATING, COOLING, OR INSULATION IN GARAGE. <br />18. PROVIDE TWO LAYERS OF GRADE DOOR 60-MINUTE GRADE D PAPER OVER ALL WOOD BASE <br />SHEATHING AT EXTERIOR WALLS. <br />19. A MINIMUM 26 GAUGE, CORROSION RESISTANT OR PLASTIC WEEP SCREED WITH A MINIMUM <br />VERTICAL FLANGE OF 3½ INCHES SHALL BE PROVIDED AT OR BELOW FOUNDATION PLATE LINE <br />ON EXTERIOR STUD WALLS. SCREED SHALL BE A MINIMUM OF 4 INCHES ABOVE EARTH OR 2 <br />INCHES ABOVE PAVED AREAS. (CRC R703.7.2.1) <br />20. CEILING SHALL NOT BE USED FOR STORAGE PURPOSES <br />21. BOTH ADU AND PRIMARY DWELLING ROOF MUST MATCH AND BE SUBSTANTIALLY SIMILAR IN <br />DESIGN, PITCH, COLOR, MATERIAL AND TEXTURE. <br />22. PER SECTION 301.1.1 CALGREEN AND CIVIL CODE 1101.3(C), ALL NON-COMPLIANT PLUMBING <br />FIXTURES WITHIN THIS RESIDENCE SHALL BE REPLACED WITH WATER-CONSERVING PLUMBING <br />FIXTURES. <br />23. THE HPWH WILL BE INSTALLED ACCORDING TO MANUFACTURER’S REQUIREMENTS <br />24. PRESCRIPTIVE INSTALLATIONS SHALL BE INDOORS AND ON A RIGID R-10 INSULATED <br />SURFACE. HPWH MUST MEET NEEA TIER3ORHIGHER. [150.2(B)1HIII] <br />XX DOOR TYPE, SEE SCHEDULE ON SHEET 01-A-202 <br />WINDOW TYPE, SEE SCHEDULE ON SHEET 01-A-202 <br />XX KEY NOTE PER SCHEDULE <br />FLOOR DEPRESSION <br />XX <br />LEGENDLEGENDLEGENDLEGEND <br />WALL TYPE, SEE SCHEDULE ON SHEET 01-A-202NWX <br />KITCHEN EXHAUST FAN MIN. 130 CFM FOR ELECTRICAL (280 CFM FOR GAS) SHALL <br />BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL <br />2X4 WALL / INFILL WITH INSULATION PER T-24 <br />EXHAUST FAN SHALL BE ENERGY STAR RATED. CEILING MOUNTED LIGHT w/ VENT 50 <br />CFM MIN. INTERMITTENT W/ HUMIDITY CONTROL PER CMC 402.5, BETWEEN <br />50%-80% SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL <br />RESIDENCE IAQ FAN 45 CFM, <br />PER T24 FOR SELECTION <br />HB <br />3/4" HOSE BIBB WITH BACK-FLOW PREVENTOR <br />SMOKE DETECTOR HARDWIRED w/ BATTERY BACK UP, PHOTOELECTRIC TYPE.SD <br />CARBON MONOXIDE DETECTOR ALARM HARDWIRED w/ BATTERY BACK UP, PHOTOELECTRIC TYPE.CD <br />ATTIC FAN COIL UNIT <br />AC CONDENSER UNIT ON PAD 3" MIN. <br />NEEA RATED HEATPUMP WATER HEATER PER T-24 <br />MODEL: PROPH50 T2 RH37515 (50 GAL, JA13) <br />2X4 1-HOUR FIRE RATED WALL <br />LAUNDRY DRYER EXHAUST <br />ELECTRICAL PANEL/METER PER KEYNOTE <br />CEILING AIR DIFFUSER <br />GARBAGE DISPOSAL <br />WALL MOUNTED A/C OUTDOOR UNIT <br />WALL MOUNTED A/C INDOOR UNIT <br />ATTIC ACCESS 24X30 <br />2 <br />R327.1.1 REINFORCEMENT FOR GRAB BARS:R327.1.1 REINFORCEMENT FOR GRAB BARS:R327.1.1 REINFORCEMENT FOR GRAB BARS:R327.1.1 REINFORCEMENT FOR GRAB BARS: <br />AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH REINFORCEMENT <br />INSTALLED IN ACCORDANCE WITH THIS SECTION. WHERE THERE IS NO BATHROOM ON THE ENTRY <br />LEVEL, AT LEAST ONE BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL <br />COMPLY WITH THIS SECTION. <br />1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED <br />BY TH REINFORCING AGENCY. <br />2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH (51 MM BY 203 MM) NOMINAL <br />LUMBER. [11/2 INCH BY 71/4 INCH (38 MM BY 184 MM) ACTUAL DIMENTION] OR OTHER <br />CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORMENT <br />SHALL BE LOCATED BETWEEN 32 INCHES (812.8 MM) AND 39 1/4 INCHES (997 MM) ABOVE <br />THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. <br />3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE <br />FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. <br />4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />5. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTTINUOS <br />ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL <br />REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE <br />LOCATED NO MORE THAN 6 INCHES (152.4 MM) ABOVE THE BATHTUB RIM. <br />EXCEPTIONS:EXCEPTIONS:EXCEPTIONS:EXCEPTIONS: <br />1. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF <br />ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION <br />OF FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS <br />APPROVED BY THE ENFORCING AGENCY. <br />2. REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PREFABRICATED SHOWER <br />ENCLOSURES AND BATHTUB WALL PANELS WITH INTEGRAL FACTORY-INSTALLED GRAB BARS <br />OR WHEN FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. <br />3. SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND /OR <br />GRAB BARS SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR- <br />MOUNTED GRAB BARS OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />4. BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE <br />INSTALLATION OF REINFORCEMENT SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR <br />INSTALLATION OF FLOOR -MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN <br />ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />5. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS AND WATER CLOSETS <br />INSTALLED ON CONCRETE SLAB FLOORS. <br />R327.1.2 ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS:R327.1.2 ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS:R327.1.2 ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS:R327.1.2 ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS: <br />ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR <br />HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE <br />LOCATED NO MORE THAN 48 INCHES (1219.2 MM) MEASURED FROM THE TOP OF THE OUTLET <br />BOX AND NOT LESS THAN 15 INCHES (381 MM) MEASURED FROM THE BOTTOM OF THE OUTLET <br />BOX ABOVE THE FINISH FLOOR. <br />EXCEPTIONS:EXCEPTIONS:EXCEPTIONS:EXCEPTIONS: <br />1. DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS; CONTROLS MOUNTED ON <br />CEILING FANS AND CEILING LIGHTS; AND CONTROLS LOCATED ON APPLIANCES. <br />2. RECEPTACLE OUTLETS REQUIRED BY THE CALIFORNIA ELECTRICAL CODE ON A WALL SPACE <br />WHERE THE DISTANCE BETWEEN THE FINISHEDFLOOR AND A BUILT-IN FEATURE ABOVE THE <br />FINISH FLOOR , SUCH AS A WINDOW, IS LESS THAN 15 INCHES (381 MM) <br />R327.1.3 INTERIOR DOORSR327.1.3 INTERIOR DOORSR327.1.3 INTERIOR DOORSR327.1.3 INTERIOR DOORS <br />EFFECTIVE JULY 1, 2024, AT LEAST ONE BATHROOM AND ONE BEDROOM ON THE ENTRY LEVEL <br />SHALL PROVIDE A DOORWAY WITH A NET CLEAR OPENING OF NOT LESS THAN 32 INCHES (812.8 <br />MM), MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM THE CLOSED <br />POSITION; OR, IN THE CASE OF A TWOOR THREE-STORY SINGLE FAMILY DWELLING, ON THE <br />SECOND OR THIRD FLOOR OF THE DWELLING IF A BATHROOM OR BEDROOM IS NOT LOCATED ON <br />THE ENTRY LEVEL. <br />R327.1.4 DOORBELL BUTTONS:R327.1.4 DOORBELL BUTTONS:R327.1.4 DOORBELL BUTTONS:R327.1.4 DOORBELL BUTTONS: <br />DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED SHALL NOT EXCEED 48 INCHES (1219.2 <br />MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL <br />BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE <br />REQUIRED TO BE INSTALLED ABOVE 48 INCHES (1219.2 MM) MEASURED FROM THE EXTERIOR <br />FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED <br />AT A HEIGHT NOT EXCEEDING 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LADING, <br />MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. <br />2 <br />01-A-201 <br />2 <br />01-A-201 <br />SD <br />SD <br />SDCD <br />(N) PORCH <br />51 SF <br />52 <br />55 <br />55 <br />54 <br />63 <br />1 <br />01-A-201 <br />1 <br />01-A-201 <br />01-A-201 <br />4 <br />01 <br />-A-20 <br />1 <br />3 <br />01 <br />-A-20 <br />1 <br />5 <br />01-A-201 <br />6 <br />1. <br />5 <br />" <br />PHO <br />TOELE <br />C <br />T <br />R <br />IC TYPE. <br />10'-2" <br />42 <br />' <br />- <br />3 <br /> <br />1 <br />/ <br />2 <br />" <br />19 <br />' <br />- <br />0 <br /> <br />1 <br />/ <br />2 <br />" <br />10 <br />' <br />- <br />0 <br /> <br />1 <br />/ <br />2 <br />" <br />2' <br />- <br />5 <br />" <br />10 <br />' <br />- <br />9 <br /> <br />1 <br />/ <br />2 <br />" <br />18'-11" <br />5'-6"2'-8"10'-9" <br />2'-11 1/2"2'-6 1/2"5'-2"5'-7" <br />5' <br />- <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />13 <br />' <br />- <br />7 <br />" <br />4' <br />- <br />0 <br /> <br />1 <br />/ <br />2 <br />" <br />8' <br />- <br />5 <br />" <br />10 <br />' <br />- <br />9 <br /> <br />1 <br />/ <br />2 <br />" <br />3' <br />- <br />1 <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />4' <br />- <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />9'-9 1/2"9'-1 1/2" <br />2'-4"4'-5"2'-7" <br />18'-11" <br />N-7 <br />N-9 <br />N-4 <br />N-3 <br />N-3 <br />N-2 <br />N-5 <br />N-A <br />N-A <br />N-C <br />N-B <br />N-1 <br />LIVING + KITCHENLIVING + KITCHENLIVING + KITCHENLIVING + KITCHEN <br />9' 0" CLG <br />WOOD <br />ADUADUADUADU----BED #1BED #1BED #1BED #1 <br />9' 0" CLG <br />WOOD <br />ADUADUADUADU----BATH#1BATH#1BATH#1BATH#1 <br />9' 0" CLG <br />TILE <br />ADUADUADUADU----BED #2BED #2BED #2BED #2 <br />9' 0" CLG <br />WOOD <br />ADUADUADUADU----BATH#2BATH#2BATH#2BATH#2 <br />9' 0" CLG <br />TILE <br />AD <br />U <br />AD <br />U <br />AD <br />U <br />AD <br />U <br />---- <br />CL <br />O <br />S <br />E <br />T <br />CL <br />O <br />S <br />E <br />T <br />CL <br />O <br />S <br />E <br />T <br />CL <br />O <br />S <br />E <br />T <br />ADUADUADUADU----CLOSETCLOSETCLOSETCLOSET <br />ADUADUADUADU----HALLWAYHALLWAYHALLWAYHALLWAY <br />9' 0" CLG <br />WOOD <br />17 <br />" <br />17 <br />" <br />20 <br />" <br />20 <br />" <br />NW <br />4 <br />NW <br />4 <br />NW <br />4 <br />NW <br />4 <br />NW4 <br />NW4 <br />NW <br />4 <br />NW4 <br />NW4 <br />NW4 <br />10" <br />33 <br />62 <br />51 <br />53 <br />60 <br />65 <br />66 <br />75 58 <br />58 <br />75 <br />66 <br />31 <br />99 <br />28.1 <br />76 <br />76 <br />1.21.41.31.7 <br />50 <br />SDCD <br />10 <br />' <br />- <br />0 <br />" <br />2'-4 1/2"10'-3" <br />9' <br />- <br />8 <br />" <br />2' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />9'-1" <br />13 <br />' <br />- <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />5' <br />- <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />9'-4"8'-8" <br />5'-4 1/2"3'-2" <br />3' <br />- <br />8 <br />" <br />8' <br />- <br />0 <br />" <br />10 <br />' <br />- <br />0 <br />" <br />5'-0" <br />9'-5 1/2" <br />36 <br />' <br />- <br />1 <br />0 <br />" <br />N-8 <br />N-6 <br />N-8 <br />3' <br />- <br />7 <br />" <br />11 <br />' <br />- <br />0 <br />" <br />4' <br />- <br />6 <br />" <br />5' <br />- <br />2 <br /> <br />1 <br />/ <br />2 <br />" <br />4' <br />- <br />1 <br />0 <br />" <br />NW <br />4 <br />75 <br />75 <br />75 <br />75 <br />75 <br />32 <br />32 <br />32 <br />ADUADUADUADU----LAUNDRYLAUNDRYLAUNDRYLAUNDRY <br />9' 0" CLG <br />TILE <br />5'-0" <br />(N) <br />LANDING <br />18 SF <br />6' <br />- <br />0 <br />" <br />3'-0" <br />3' <br />- <br />0 <br />" <br />7'-0" <br />1.5" <br />1. <br />5 <br />" <br />6. <br />5 <br />" <br />2 <br />2 <br />6.5" <br />1. (N) ROOF MATERIAL COVERING CLASS "A" ASPHALT SHINGLES BY CERTAINTEED ICC-ESR# 3537 OR EQUAL. <br />THE INSTALLATION OF ROOF COVERING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. <br />2. PROJECTIONS LESS THAN 3'-0" (HOUSE WITH SPRINKLER) OR 5'-0" (HOUSE WITH NO SPRINKLER) TO <br />PROPERTY LINE TO BE 1-HOUR CONSTRUCTION, TYP. <br />3. PROVIDE MIN. 2% SLOPE AT FLAT ROOF AND DECK (IF OCCUR). <br />4. BOTH ADU AND PRIMARY DWELLING ROOF MUST MATCH AND BE SUBSTANTIALLY SIMILAR IN DESIGN, PITCH, <br />COLOR, MATERIAL AND TEXTURE. <br />5. INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURER’S SPECIFICATIONS. <br />1. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE <br />UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING <br />OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL HAVE AT <br />LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS HAVING A LEAST DIMENSION LARGER THAN <br />1/4" SHALL BE PROVIDED W/. CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, OR <br />SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIM. OF 1/16" MIN. AND 1/4" MAX. OPENINGS IN ROOF <br />FRAMING MEMBERS SHALL CONFORM TO THE REQ'TS. OF CRC R802.7. REQUIRED VENTILATION OPENINGS <br />SHALL OPEN DIRECTLY TO THE OUTSIDE AIR. <br />2. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED. <br />THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/300 IF ONE OR MORE OF THE FOLLOWING ARE <br />MET; 1. IN CLIMATE ZONES 14 & 16, A CLASS I OR II VAPOR RETARDER IS INSTALLED ON THE WARM-IN-WINTER <br />SIDE OF THE CEILING. 2. AT LEAST 40% AND MORE THAN 50% OF THE REQUIRED VENTILATING ARE IS <br />PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER <br />VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE <br />SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF TEH REQUIRED VANTILATION PROVIDED BY EAVE OR <br />CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE <br />INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST OF <br />THE SPACE SHALL BE PERMITTED. <br />3. WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A <br />MIN. OF A 1" SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHT'G. AND AT THE <br />LOCATION OF THE VENT. <br />4. VENTILATORS SHALL BE INSTALLED IN ACCORDANCE WITH MFR'G.'S INSTALLATION INSTRUCTIONS. <br />INSTALLATION OF VENTILATORS IN ROOF SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF SECTION <br />R903. INSTALLATION OF VENTILATORS IN WALL SYSTEMS SHALL BE IN ACCORDANCE W/. THE REQ'TS. OF <br />SECTION R703.1. <br />5. UNVENTED ATTIC ASSEMBLIESUNVENTED ATTIC ASSEMBLIESUNVENTED ATTIC ASSEMBLIESUNVENTED ATTIC ASSEMBLIES (SPACES BETWEEN THE CEILING JOISTS OF THE TOP STORY AND THE ROOF <br />RAFTERS) AND UNVENTED ENCLOSED RAFTER ASSEMBLIESAND UNVENTED ENCLOSED RAFTER ASSEMBLIESAND UNVENTED ENCLOSED RAFTER ASSEMBLIESAND UNVENTED ENCLOSED RAFTER ASSEMBLIES (SPACES BETWEEN CEILINGS THAT ARE APPLIED <br />DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING MEMBER/RAFTERS AND THE STRUCTURAL ROOF SHT'G. AT <br />THE TOP OF THE ROOF FRAMING MEMBERS/RAFTERS) SHALL BE PERMITTED IF ALL OF THE FOLLOWING <br />CONDITIONS ARE MET: <br />1. THE UNVENTED ATTIC SPACE IS COMPLETELY CONTAINED WITHIN THE BUILDING THERMAL ENVELOPE. <br />2. NO INTERIOR CLASS I VAPOR RETARDERS ARE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE <br />UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED RAFTER ASEEMBLY. <br />3. WHERE WOOD SHINGLES OF SHAKES ARE USED, A MIN. 1/4" VENTED AIR SPACE SEPARATES THE SHINGLES <br />OR SHAKES AND THE ROOFING UNDERLAYMENT ABOVE THE STRUCTURAL SHT'G. <br />4. IN CALIFORNIA CLIMATE ZONES 14 & 16, ANY AIR-IMPERMEABLE INSULATION SHALL BE A CLASS II VAPOR <br />RETARDER, OR SHALL HAVE A CLASS III VAPOR RETARDER COATING OR COVERING IN DIRECT CONTACT W/. <br />THE UNDERSIDE OF THE INSULATION (SEE TITLE 24, PART 6, FIG. 100.1-A) <br />5. EITHER ITEMS 5.1, 5.2 OR 5.3 SHALL BE MET, DEPENDING ON THE AIR PERMEABILITY OF THE INSULATION <br />DIRECTLY UNDER THE STRUCTURAL ROOF SHT'G. (NO INSULATION SHALL BE REQ'D. WHEN ROOF TILES, WOOD <br />SHINGLES OR WOOD SHAKES, OR ANY OTHER ROOFING SYSTEM USING BATTENS AND NO CONT. <br />UNDERLAYMENT IS INSTALLED. A CONT. LAYER SHALL BE CONSIDERED TO EXIST IF SHT'G., ROOFING PAPER OR <br />ANY CONT. LAYER WHICH HAS A PERM RATE OF NO MORE THAN ONE PERM UNDER THE DRY CUP METHOD.); <br />5.1. AIR-IMPERMEABLE INSULATION ONLY. INSULATION SHALL BE APPLIED IN DIRECT CONTACT W/. THE <br />UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. <br />5.2. AIR-PERMEABLE INSULATION ONLY. IN ADDITION TO THE AIR-PERMEABLE INSULATION INSTALLED <br />DIRECTLY BELOW THE STRUCTURAL SHT'G., RIDGE BOARD OR SHEET INSULATION W/. AN R-VALUE OR R-4 <br />SHALL BE INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION CONTROL. <br />5.3. AIR-IMPERMEABLE AND AIR-PERMEABLE INSULATION. THE AIR-IMPERMEABLE INSULATION SHALL BE <br />APPLIED IN DIRECT CONTACT W/. THE UNDERSIDE OF THE STRUCTURAL ROOF SHT'G. FOR CONDENSATION <br />CONTROL. THE AIR-PERMEABLE INSULATION SHALL BE INSTALLED DIRECTLY UNDER TH AIR-PERMEABLE <br />INSULATION. <br />5.4. WHERE PREFORMED INSULATION BOARD IS USED AS THE AIR0IMPERMEABLE INSULATION LAYER, IT <br />SHALL BE SEALED AT THE PERIMETER OF EACH INDIVIDUAL SHEET INTERIOR SURFACE TO FORM A CONT. <br />LAYER. <br />6.VENT OPENINGS SHALL BE PROVIDED WITH CORROSION-RESISTANT WIRE MESH WITH 1/16'' MINIMUM TO <br />1/4'' MAXIMUM OPENINGS. A MINIMUM OF A 1-INCH AIRSPACE MUST BE MAINTAINED BETWEEN THE <br />INSULATION AND THE ROOF SHEATHING AT THE LOCATIONS OF THE VENTS. [CRC R806] <br />NEW DETACHED ADU ATTIC AREA : 749 SFNEW DETACHED ADU ATTIC AREA : 749 SFNEW DETACHED ADU ATTIC AREA : 749 SFNEW DETACHED ADU ATTIC AREA : 749 SF <br />NET VENT AREA REQUIRE: 749/150 x 144SQ.IN = 719 SQ.IN <br />USE 10 O'HAGIN 72 SQ. IN/UNIT, SEE SPEC. <br />2 <br />01-A-201 <br />2 <br />01-A-201 <br />1 <br />01-A-201 <br />1 <br />01-A-201 <br />01-A-201 <br />4 <br />01 <br />-A-20 <br />1 <br />3 <br />01 <br />-A-20 <br />1 <br />5 <br />01-A-201 <br />6 <br />3'-0" <br />(N) DETACHED ADU(N) DETACHED ADU(N) DETACHED ADU(N) DETACHED ADU <br />1 STORY1 STORY1 STORY1 STORY <br />(N) ROOF <br />1' <br />- <br />0 <br />" <br />6" <br />1'-0" <br />6' <br />- <br />5 <br /> <br />1 <br />/ <br />2 <br />" <br />10'-4" <br />1' <br />- <br />0 <br />" <br />(N) ATTIC <br />AREA <br />749 SF <br />2.7 kWdc (PER T2.7 kWdc (PER T2.7 kWdc (PER T2.7 kWdc (PER T ----24) 24) 24) 24) <br />PV SYSTEMPV SYSTEMPV SYSTEMPV SYSTEM <br />(N) SOLAR PANEL(N) SOLAR PANEL(N) SOLAR PANEL(N) SOLAR PANEL <br />(N) O'HAGIN VENTILATION(N) O'HAGIN VENTILATION(N) O'HAGIN VENTILATION(N) O'HAGIN VENTILATION <br />(N) ROOF MATERIAL COVERING CLASS "A" <br />ASPHALT SHINGLES BY CERTAINTEED <br />ICC-ESR# 3537 OR EQUAL. OVER PLYWOOD <br />SHEATING OVER RADIANT BARRIER OVER <br />RAFTERS PER STRUCTURAL DWGS. ROOF <br />COLOR AND MATERIAL TO MATCH WITH <br />EXISTING BUILDING, EQUAL. <br />(N) PORCH BELOW(N) PORCH BELOW(N) PORCH BELOW(N) PORCH BELOW <br />(N) POST BELOW <br />3:123:12 <br />3:123:12 <br />WA <br />L <br />L <br /> <br />L <br />I <br />N <br />E <br /> <br />B <br />E <br />L <br />O <br />W <br />, <br /> <br />T <br />Y <br />P <br />. <br />WA <br />L <br />L <br /> <br />L <br />I <br />N <br />E <br /> <br />B <br />E <br />L <br />O <br />W <br />, <br /> <br />T <br />Y <br />P <br />. <br />WALL LINE BELOW, TYP. <br />WALL LINE BELOW, TYP. <br />WALL LINE BELOW, TYP. <br />BEAM LINE BELOW, TYP. <br />BE <br />A <br />M <br /> <br />L <br />I <br />N <br />E <br /> <br />B <br />E <br />L <br />O <br />W <br />, <br /> <br />T <br />Y <br />P <br />. <br />1 <br />01-A-301 <br />3 <br />01-A-301 <br />4 <br />01-A-301 <br />2 <br />01-A-301 <br />2025.03 <br />10.10.2025 <br />©2025Sheet No. <br />Rev. <br />Project No. <br />Date Print: <br />Design by <br />TRINH HA. <br />Date. <br />Pr <br />o <br />j <br />e <br />c <br />t <br />: <br />Description. <br />1.07.23.2025Correction 1st. <br />2.09.12.2025Correction 2nd. <br />01-A-200 <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br /> <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br /> <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br /> <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br /> <br />---- <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />Ad <br />d <br />r <br />e <br />s <br />s <br /> <br />M <br />a <br />i <br />n <br /> <br />H <br />o <br />u <br />s <br />e <br />: <br /> <br />4 <br />2 <br />1 <br /> <br />S <br /> <br />C <br />e <br />n <br />t <br />e <br />r <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />92 <br />7 <br />0 <br />3 <br />Ad <br />d <br />r <br />e <br />s <br />s <br /> <br />D <br />e <br />t <br />a <br />c <br />h <br />e <br />d <br /> <br />A <br />D <br />U <br />: <br /> <br />4 <br />2 <br />3 <br /> <br />S <br /> <br />C <br />e <br />n <br />t <br />e <br />r <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br />9 <br />2 <br />7 <br />0 <br />3 <br />PROPOSED_ ADU <br />FLOOR & ROOF <br />PLAN <br />FLOOR PLAN NOTESFLOOR PLAN NOTESFLOOR PLAN NOTESFLOOR PLAN NOTES <br />FLOOR PLAN LEGENDSFLOOR PLAN LEGENDSFLOOR PLAN LEGENDSFLOOR PLAN LEGENDS FLOOR PLAN KEYNOTESFLOOR PLAN KEYNOTESFLOOR PLAN KEYNOTESFLOOR PLAN KEYNOTES <br />1.2 (N) ELECTRICAL PANEL FOR ADU 200 AMP, WITH A 225A BUS BAR <br />1.3 "(N) 60 AMP SUBPANEL FOR ADU ESS SYSTEM" <br />1.4 (N) ELECTRICAL METER FOR ADU 200 AMP <br />1.7 (N) ELECTRICAL METER FOR MAINHOUSE 200 AMP, RELOCATION <br />28.1 (N) POST, PER STRUCT. <br />31 (N) DUCTLESS MULTI-SPLIT SYSTEM AC. PER T-24 <br />32 (N) WALL MOUNTED AC INDOOR UNIT PER T-24 <br />33 (N) HEAT PUMP WATER HEATERS PER T-24, MODEL: PROPH50 T2 RH37515 (50 GAL, JA13) , EQUIPMENT CABINET TO BE <br />PAINTED TO MATCH THE ADU EXTERIOR MATERIALS <br />50 (N) 24"X30" ATTIC ACCESS <br />51 (N) 36" COOK-TOP. PROVIDE EXHAUST HOOD WITH LIGHT AND FAN VENT TO OUTSIDE AIR (280 CFM) WITH 8" DUCT. VERIFY <br />DIMENSIONS AND POWER REQUIREMENTS WITH MANUFACTURER'S SPECIFICATIONS. <br />52 THIS SWITCH CONTROLS THE INDOOR AIR QUALITY VENTILATION FOR THE HOME. LEAVE SWITCH IN THE 'ON' POSITION AT ALL <br />TIMES UNLESS THE OUTDOOR AIR QUALITY IS VERYPOOR."[150.0(O)J] <br />53 LOUVERED DOOR HAVE 100SQ.IN AIR GRILL TO MAKEUP AIR <br />54 <br />"MIN. 4"" DIA. TO THE OUTSIDE, EQUIPPED WITH A BACK DRAFT DAMPER. DUCT LENGTH OR SIZES AS PERMITTED OR <br />REQUIRED BY MANUFACTURERS INSTALLATIONS AND APPROVED BY THE BUILDING OFFICIAL (EXHAUST THROUGH EXTERIOR <br />WALL/ROOF)" <br />55 <br />"EXHAUST FAN FOR BATHROOM SHALL BE ENERGY STAR RATED. CEILING MOUNTED LIGHT W/ VENT 50CFM MIN. <br />INTERMITTENT W/HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50-80% SHALL BE DUCTED TO OUTSIDE THROUGH <br />ROOF/EXTERIOR WALL" <br />58 2" SHOWER CURB <br />60 FUTURE INSTALLED FLOOR MOUNTED FOLDABLE GRAB BAR <br />62 36'' HIGH CUSTOM COUNTERTOP w/ 6'' SPLASH & RETURN <br />63 BUILT-IN UNDER-COUNTER DISHWASHER. VERIFY DIMENSIONS WITH MANUFACTURER'S SPECIFICATIONS. <br />65 GRAB BAR REINFORCEMENT, TYP. <br />66 SMOOTH, NON-ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLE. <br />75 TEMPERED GLASS <br />76 "TEMPERED, OBSCURED GLASS" <br />99 1HR FIRE-RATED WALL PROVIDE UNPROTECTED OPENING MAX 25% OF WALL AREA, SEE CALCUALTION ON ELEVATION VIEW. <br />ADUADUADUADU---- DOOR SCHEDULEDOOR SCHEDULEDOOR SCHEDULEDOOR SCHEDULE <br />ADUADUADUADU---- WINDOW SCHEDULEWINDOW SCHEDULEWINDOW SCHEDULEWINDOW SCHEDULEAGINGAGINGAGINGAGING----IN PLACE NOTES:IN PLACE NOTES:IN PLACE NOTES:IN PLACE NOTES: <br />1/4" = 1'-0"1PROPOSED ADU FLOOR PLAN <br />ID QTY DOOR SIZE DESCRIPTION U-FACTOR SHGC REMARK <br />N-1 1 3' - 0" x 6' - 8" EXTEIOR DOOR, SWING DOOR, HOLLOW CORE, WOOD FRAME, TEMPERED <br />GLASS, PAINTED FINISH. <br />0.5 ENTRY DOOR (1), (2), (3), (9) <br />N-2 1 2' - 8" x 6' - 8" SWING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.INTERIOR DOOR <br />N-3 2 2' - 10" x 6' - 8" SWING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.INTERIOR DOOR <br />N-4 1 2' - 4" x 6' - 8" SWING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.INTERIOR DOOR <br />N-5 1 3' - 0" x 6' - 8" FRENCH DOOR 2-PANEL SWING/GLASS, WITH LOUVER, WOOD FRAME, <br />PAINTED FINISH <br />LOUVER DOOR <br />N-6 1 5' - 0" x 6' - 8" SLIDING DOOR, HOLLOW CORE, WOOD FRAME, TEMPERED GLASS, PAINTED <br />FINISH. <br />0.3 0.23 EXTERIOR DOOR <br />N-7 1 5' - 6" x 6' - 8" SLIDING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.INTERIOR DOOR <br />N-8 2 6' - 0" x 6' - 8" SLIDING DOOR, HOLLOW CORE, WOOD FRAME, TEMPERED GLASS, PAINTED <br />FINISH. <br />0.3 0.23 EXTERIOR DOOR <br />N-9 1 5' - 0" x 6' - 8" SLIDING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.INTERIOR DOOR <br />TOTAL: 11 <br />ID QTY WINDOW SIZE DESCRIPTION U-FACTOR SHGC REMARK <br />N-A 2 3' - 0" x 2' - 0" SLIDER, DUAL GLASS/ FIBERGLASS FRAME, SOLID CORE, FINISH PER MFGR. 0.3 0.23 TEMP. OBSCURED @BATH (5), (10) <br />N-B 1 3' - 0" x 3' - 6" SLIDER, DUAL GLASS/ FIBERGLASS FRAME, SOLID CORE, FINISH PER MFGR. 0.3 0.23 <br />N-C 1 4' - 0" x 4' - 0" SLIDER, DUAL GLASS/ FIBERGLASS FRAME, SOLID CORE, FINISH PER MFGR. 0.3 0.23 <br />TOTAL: 4 <br />ROOF PLAN GENERAL NOTESROOF PLAN GENERAL NOTESROOF PLAN GENERAL NOTESROOF PLAN GENERAL NOTES <br />VENTILATION NOTESVENTILATION NOTESVENTILATION NOTESVENTILATION NOTES <br />ATTIC & RAFTER CAVITY VENTILATIONATTIC & RAFTER CAVITY VENTILATIONATTIC & RAFTER CAVITY VENTILATIONATTIC & RAFTER CAVITY VENTILATION <br />1/4" = 1'-0"2PROPOSED ADU ROOF PLAN