Laserfiche WebLink
1. ALL DOORS AND WINDOWS SHALL MEET CITY'S SECURITY ORDINANCE. <br />2. ALL EXTERIOR DOORS & WINDOWS SHALL BE WEATHER TIED AND PROVIDE WITH INSECT <br />SCREEN-METAL. DOORS & WINDOWS SHALL BE IN COMPLIANCE WITH ANSI. STD. A13 OR <br />A1342. <br />3. THE MANUFACTURED WINDOWS AND SLIDING DOOR SHALL HAVE A LABEL ATTACHED <br />CERTIFIED BY THE NATIONALS FENESTRATION RATING COUNCIL (NFRC) AND COMPLIANCE <br />WITH THE ENERGY CALCULATIONS. <br />4. THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN <br />ACCORDANCE WITH ASTM E1300. <br />5. ALL TEMPERED GLASS (T.G.) SHALL BE ACID-ETCHED, SAND-BLASTED, CERAMIC-FIRED, <br />LASER-ETCHED, OR EMBOSSED PER CRC 2406.3. <br />6. GLAZING AND INSULATION SHALL CONFORM TO THE STATE ENERGY INSULATION STANDARD. <br />7. DEAD BOLT LOCKS ARE REQUIRED ON ALL EXTERIOR DOORS (INCLUDING HOUSE TO <br />GARAGE) <br />8. GLAZING SHALL BE SAFETY GLAZING IF LESS THAN 72" ABOVE BATHROOM FINISH FLOOR <br />9. SLIDING GLASS DOORS AND WINDOWS LOCATED LESS THAN 16 FEET ABOVE ANY SURFACE <br />AVAILABLE FOR USE BY THE PUBLIC SHALL BE CAPABLE OF BEING LOCKING SECURELY. <br />MOVEABLE PANELS SHALL NOT BE EASILY REMOVED FROM THE FRAME. <br />10. ALL MAIN OR FRONT ENTRY TO DWELLINGS SHALL BE ARRANGED SO THAT THE OCCUPANT <br />HAS A VIEW OF THE AREA IMMEDIATELY OUTSIDE WITHOUT OPENING DOOR. SUCH VIEW MAY <br />BE POVIDED BY A DOOR VIEW, A VIEW PORT, WINDOW, OR OTHER OPENING. <br />11. ALL SWINGING DOORS SHALL BE EQUIPPED WITH A DEAD BOLT WITH A MINIMUM THROW OF <br />1 INCH AND AN EMBEDMENT OF NOT LESS THAN 5/8 INCH. <br />12. THE INACTIVE LEAF OF A PAIR OF DOORS AND THE UPPER LEAF OF DUTCH DOORS SHALL BE <br />EQUIPPED WITH A DEAD BOLT. <br />13. NON-REMOVABLE PINS SHALL BE USED IN PIN TYPE HINGES WHICH ARE ACCESSIBLE FROM <br />THE OUTSIDE WHEN THE DOOR IS CLOSED. <br />14. UNFRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THAN 1/2" THICK. <br />15. NARROW-FRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THAN 1/4" <br />THICK. <br />16. ANY GLASS WHICH IS LOCATED WITHIN 40 INCHES OF THE BLOCKING DEVICE ON A DOOR <br />SHALL BE FULLY TEMPERED, OR HAVE APPROVED METAL BARS, SCREENS OR GRILLS. <br />17. IT IS CONTRACTOR'S RESPONSIBILITY TO CONFIRM DOOR/WINDOW ROUGH OPENING <br />DIMENSIONS WITH THE MANUFACTURE/SUPPLIER PRIOR TO BEGIN CONSTRUCTION <br />18. AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH <br />UL 325. (R309.4) <br />19. WINDOW AREA OF HABITABLE ROOMS MUST BE AT LEAST 8% OF THE ROOM FLOOR AREA. <br />(R303.10) <br />20. OPENABLE WINDOWAREA OFHABITABLEROOMS MUST BE 4% OFTHEROOM FLOOR AREA. <br />(CRC R303.1) <br />21. EMERGENCY EGRESS: <br />A. MIN. SET CLEAR OPENING OF 5.7 SQUARE FEET. <br />B. MIN. SET CLEAR HEIGHT OF 24 INCHES AND 20 INCH WIDTH. <br />C. WINDOW SILL CLEAR OPENING EMERGENCY EGRESS NO MORE THAN 44 INCHES ABOVE <br />THE FLOOR. <br />1. STRING SHALL BE FABRICATED FROM EITHER HARD-DRAWN SPRING WIRE ( PER ASTM A227-21) OR <br />OIL-TEMPERED WIRE ( PER ASTM A229-71) <br />2. MINIMUM DESIGN STANDARD SHALL BE 9000 CYCLES. <br />3. PHYSICAL CYCLING TESTS SHALL BE EQUIPPED WITH AN APPROVED TESTING AGENCY. <br />4. PHYSICAL CYCLING TESTS SHALL BE EQUIPPED WITH AN APPROVED DEVICE CAPABLE OF <br />RESTRAINING THE SPRING OR ANY PART THERE OF IN THE EVENT IT BREAKS. CONTAINMENT DEVICE <br />SHALL BE TESTED AND CERTIFIED BY AN APPROVED TESTING AGENCY. <br />GARAGE DOOR STRINGS PER SEC. R309.5GARAGE DOOR STRINGS PER SEC. R309.5GARAGE DOOR STRINGS PER SEC. R309.5GARAGE DOOR STRINGS PER SEC. R309.5 <br />(1) DOOR SHALL HAVE A MINIMUM CLEAR WIDTH OF 32" WHEN MEASURED BETWEEN THE FACE OF THE <br />DOOR AND THE STOP,WITH THE DOOR OPEN AT 90 DEGREE. <br />(2) DOOR SHALL HAVE A MINIMUM CLEAR HEIGHT OF 78", MEASURED FROM THE TOP OF THE <br />THRESHOLD TO THE BOTTOM OF THE STOP <br />(3) DOOR SHALL BE READILY OPENABLE FROM THE INSIDE THE DWELLING WITHOUT THE USE OF A KEY <br />OR SPECIAL KNOWLEDGE OR EFFORT. <br />(4) SELF-CLOSING, TIGHT FITTING, SOLID WOOD, 1-3/8'' THICK DOOR, NOT LESS THAN 20-MIN FIRERATED <br />DOOR AT OPENING TO DWELLING (CBC 715.4.3). <br />(5) MIN. 72'' ABOVE FINISH FLOOR IN BATHROOMS. <br />(6) THE MANUFACTURED WINDOWS AND SLIDING DOOR SHALL HAVE A LABEL ATTACHED CERTIFIED BY <br />THE NATIONALS FENESTRATION RATING COUNCIL (NFRC) AND COMPLIANCE WITH THE ENERGY <br />CALCULATIONS. <br />(7) THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN ACCORDANCE <br />WITH ASTM E1300. <br />(8) ALL TEMPERED GLASS (T.G.) SHALL BE ACID-ETCHED, SAND-BLASTED, CERAMIC-FIRED, ASER-ETCHED, <br />OR EMBOSSED PER CRC 2406.3. <br />(9) DEAD BOLT LOCKS ARE REQUIRED ON ALL EXTERIOR DOORS (INCLUDING HOUSE TO GARAGE <br />(10) GLAZING SHALL BE SAFETY GLAZING IF LESS THAN 72" ABOVE BATHROOM FINISH FLOOR <br />DOOR/WINDOW REMARKSDOOR/WINDOW REMARKSDOOR/WINDOW REMARKSDOOR/WINDOW REMARKS <br />(1) SEAL AND PAINTED W/ A COAT FLAT VINYL. <br />(2) UNDERCOAT AND FINISH W/SEMI-GLOSS ENAMEL. <br />(3) KNOCKDOWN TEXTURE. <br />(4) TAPED DRYWALL JOINTS. <br />(5) SPRAYED SIMULATED ACOUSTIC PLASTER. <br />(6) ORANGE PEEL FINISH. <br />FINISH NOTES:FINISH NOTES:FINISH NOTES:FINISH NOTES: <br />NW4 4" WALL NEW WALL <br />WALL ID WALL THICKNESS REMARK <br />EW4 4" WALL EXISTING WALL <br />NW6 6" WALL NEW WALL <br />1. GYPSUM BOARD SHALL NOT BE USED WHERE THERE WILL BE DIRECT <br />EXPOSURE TO WATER, OR IN AREAS SUBJECT TO CONTINUOUS HIGH <br />HUMIDITY. CRC R702.3.7.1 <br />2. ALL DOORS & WINDOWS SHALL MEET CITY'S SECURITY ORDINANCE <br />3. CONCRETE SLAB AND UNDER FLOOR INSPECTIONS SHALL BE MADE AFTER IN- <br />SLAB OR UNDER-FLOOR REINFORCING STEEL AND BUILDING SERVICE <br />EQUIPMENT, CONDUITS, PIPING OR OTHER ANCILLARY BUILDING TRADE <br />PRODUCTS OR EQUIPMENT ARE INSTALLED, BUT BEFORE ANY CONCRETE IS <br />PLACED OR FLOOR SHEATHING IS INSTALLED, INCLUDING THE SUBFLOOR <br />R109.1.1.1 <br />4. ROUGH INSPECTION OF PLUMBING, MECHANICAL, GAS AND ELECTRICAL <br />SYSTEMS SHALL BE MADE PRIOR TO COVERING OR CONCEALMENT, BEFORE <br />FIXTURES OR APPLIANCES ARE SET OR INSTALLED, AND PRIOR TO FRAMING <br />INSPECTION R109.1.2 <br />5. FIRE SPRINKLER PLANS STAMPED APPROVED BY THE CITY'S FIRE <br />DEPARTMENT SHALL BE PROVIDED AT THE SITE AT TIME OF FRAMING <br />INSPECTION. <br />6. WATER PIPING MATERIAL WITHIN A BUILDING SHALL BE IN ACCORDANCE <br />WITH SEC 604.1 OF THE CALIFORNIA PLUMBING CODE. PEX, CPVC AND OTHER <br />PLASTIC WATER PIPING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH <br />THE REQUIREMENTS OF SEC 604 OF THE CPC, INSTALLATION STANDARDS OF <br />APPENDIX 1 OF THE CPC AND MANUFACTURERS RECOMMENDED <br />INSTALLATION STANDARDS. CPVC WATER PIPING REQUIRESA CERTIFICATION <br />OF COMPLIANCE AS SPECIFIED IN SEC 604.4.1.1 OF THE CPC PRIOR TO <br />PERMIT ISSUANCE. <br />BUILDING DEPT. NOTES:BUILDING DEPT. NOTES:BUILDING DEPT. NOTES:BUILDING DEPT. NOTES: <br />2025.03 <br />10.10.2025 <br />©2025Sheet No. <br />Rev. <br />Project No. <br />Date Print: <br />Design by <br />TRINH HA. <br />Date. <br />Pr <br />o <br />j <br />e <br />c <br />t <br />: <br />Description. <br />1.07.23.2025Correction 1st. <br />2.09.12.2025Correction 2nd. <br />01-A-202 <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br /> <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br /> <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br /> <br />CE <br />N <br />T <br />E <br />R <br /> <br />S <br />T <br /> <br />---- <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />Ad <br />d <br />r <br />e <br />s <br />s <br /> <br />M <br />a <br />i <br />n <br /> <br />H <br />o <br />u <br />s <br />e <br />: <br /> <br />4 <br />2 <br />1 <br /> <br />S <br /> <br />C <br />e <br />n <br />t <br />e <br />r <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />92 <br />7 <br />0 <br />3 <br />Ad <br />d <br />r <br />e <br />s <br />s <br /> <br />D <br />e <br />t <br />a <br />c <br />h <br />e <br />d <br /> <br />A <br />D <br />U <br />: <br /> <br />4 <br />2 <br />3 <br /> <br />S <br /> <br />C <br />e <br />n <br />t <br />e <br />r <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br />9 <br />2 <br />7 <br />0 <br />3 <br />DOOR & WINDOW <br />SCHEDULE <br />DOOR / WINDOW NOTESDOOR / WINDOW NOTESDOOR / WINDOW NOTESDOOR / WINDOW NOTESWALL FINISH SCHEDULEWALL FINISH SCHEDULEWALL FINISH SCHEDULEWALL FINISH SCHEDULEDOOR SCHEDULEDOOR SCHEDULEDOOR SCHEDULEDOOR SCHEDULE WINDOW SCHEDULEWINDOW SCHEDULEWINDOW SCHEDULEWINDOW SCHEDULE <br />ID QTY WINDOW SIZE DESCRIPTION U-FACTOR SHGC REMARK <br />N-A 2 3' - 0" x 2' - 0" SLIDER, DUAL GLASS/ FIBERGLASS FRAME, SOLID CORE, FINISH PER MFGR. 0.3 0.23 TEMP. OBSCURED @BATH (5), (10) <br />N-B 1 3' - 0" x 3' - 6" SLIDER, DUAL GLASS/ FIBERGLASS FRAME, SOLID CORE, FINISH PER MFGR. 0.3 0.23 <br />N-C 1 4' - 0" x 4' - 0" SLIDER, DUAL GLASS/ FIBERGLASS FRAME, SOLID CORE, FINISH PER MFGR. 0.3 0.23 <br />TOTAL: 4 <br />ID QTY DOOR SIZE DESCRIPTION U-FACTOR SHGC REMARK <br />N-1 1 3' - 0" x 6' - 8" EXTEIOR DOOR, SWING DOOR, HOLLOW CORE, WOOD FRAME, TEMPERED GLASS, PAINTED FINISH. 0.5 ENTRY DOOR (1), (2), (3), (9) <br />N-2 1 2' - 8" x 6' - 8" SWING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.INTERIOR DOOR <br />N-3 2 2' - 10" x 6' - 8" SWING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.INTERIOR DOOR <br />N-4 1 2' - 4" x 6' - 8" SWING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.INTERIOR DOOR <br />N-5 1 3' - 0" x 6' - 8" FRENCH DOOR 2-PANEL SWING/GLASS, WITH LOUVER, WOOD FRAME, PAINTED FINISH LOUVER DOOR <br />N-6 1 5' - 0" x 6' - 8" SLIDING DOOR, HOLLOW CORE, WOOD FRAME, TEMPERED GLASS, PAINTED FINISH. 0.3 0.23 EXTERIOR DOOR <br />N-7 1 5' - 6" x 6' - 8" SLIDING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.INTERIOR DOOR <br />N-8 2 6' - 0" x 6' - 8" SLIDING DOOR, HOLLOW CORE, WOOD FRAME, TEMPERED GLASS, PAINTED FINISH. 0.3 0.23 EXTERIOR DOOR <br />N-9 1 5' - 0" x 6' - 8" SLIDING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.INTERIOR DOOR <br />TOTAL: 11