Laserfiche WebLink
COVER SHEET <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-1 <br />AN <br />D <br />Y <br /> <br />M <br />A <br />I <br />18 <br />3 <br />4 <br /> <br />W <br /> <br />3 <br />R <br />D <br /> <br />S <br />T <br />, <br /> # <br />3 <br /> <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br /> <br />PH <br />O <br />N <br />E <br /> <br /># <br />: <br /> <br />N <br />/ <br />A <br />REVDATEDESCRIPTION <br />REVISIONS <br />CONTRACTOR INFORMATION <br />GREEN HILL SOLAR INC <br />7020 MIDDLESBURY RIDGE CIR., <br />WEST HILLS, CA 91307 <br />CSLB 938682, C-46 (Exp 10/31/2025) <br />PHONE: (888) 902-3551 <br />SCOPE OF WORK <br />SYSTEM SIZE: 5 x 435 = 2.18KW <br />CEC AC: 2.03KW <br />MODULES: (5) MISSION SOLAR: MSX10-435HN0B 435W MODULES <br />MODULE MAX POWER (P/MAX): 435W <br />INVERTER: (5) ENPHASE: IQ8MC-72-M-US @ (240V) MICROINVERTERS <br />RACKING: IRONRIDGE XR10 RAIL <br />ATTACHMENT: IRONRIDGE FLASHFOOT 2 <br />VICINITY MAP <br />ADU BUILDING INFORMATION: ONE STORY ADU <br />TYPE OF CONSTRUCTION: V-B <br />OCCUPANCY: RESIDENTIAL GROUP R - 3 <br />APN# 00716318 <br />ROOF TYPE: COMP. SHINGLES <br />ROOF RAFTERS: 2"X6" @ 16" O.C. <br />ELECTRICAL INFORMATION <br />UTILITY COMPANY: SCE <br />MAIN SERVICE AMPERAGE: 200A <br />ARRAY TILT:ARRAY AZIMUTH: <br />#1 - 26°#1 - 180° <br />CODE SUMMARY <br />THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />2022 CALIFORNIA ENERGY CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2020 NATIONAL ELECTRICAL CODE <br />ALL OTHER ORDINANCES ADOPTED BY THE LOCAL <br />GOVERNING AGENCIES. <br />TABLE OF CONTENTS <br />PAGE #DESCRIPTION <br />PV 1 COVER SHEET <br />PV 2 SITE PLAN <br />PV 3 ARRAY DETAIL <br />PV 4 STRING LAYOUT <br />PV 5-6 ATTACHMENT DETAIL <br />PV 7 ELECTRICAL DIAGRAM <br />PV8 ELECTRICAL CALCULATION <br />PV 9 PLACARD <br />PV 10+SPEC SHEETS <br />GENERAL NOTES: <br />·LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR <br />PHOTOVOLTAIC INSTALLATION. <br />·THIS PROJECT SHALL COMPLY WITH LOCAL ORDINANCES <br />·PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED <br />·ALL ELECTRICAL WORK SHOWN ON THESE PLANS WILL BE COMPLETED BY THE UNDERSIGNED <br />·ALL APPLICABLE PV EQUIPMENT LISTED AND COMPLIANT WITH UL2703, UL1741 AND UL1703 <br />·ALL ROOF PENETRATIONS TO BE SEALED WITH A HIGH PERFORMANCE ROOF SEALANT SUCH AS <br />GeoCel 2300 CLEAR SEALANT <br />·THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION <br />AND THE UTILITY IS OBTAINED <br />·THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, <br />OR BUILDING ROOF VENTS <br />·IF THE EXISTING MAIN PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE, IT IS THE <br />NECESSARY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE <br />·EACH MODULE WILL BE GROUNDED UL 2703 OR UL 1703 APPROVED USING THE SUPPLIED <br />CONNECTION POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS" <br />·A LADDER SHALL BE IN PLACE FOR THE INSPECTION IN COMPLIANCE WITH CAL-OSHA <br />REGULATIONS <br />·PHOTOVOLTAIC SYSTEM INVERTER IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED <br />IN THE INVERTER, AND SYSTEM COMPLIES WITH 690.35. <br />·MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. <br />·INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. <br />·ELECTRICAL EQUIPMENT AND MATERIAL TO BE LISTED, LABELED, AND INSTALLED PER THE NEC, <br />THE INSTALLATION STANDARDS/MANUFACTURER'S RECOMMENDATIONS AND IF REQUIRED A <br />RECOGNIZED ELECTRICAL TESTING LABORATORY. <br />·CONDUITS AND CABLES EXPOSED TO SUNLIGHT ON ROOF SHALL BE LOCATED NOT LESS THAN <br />7/8" ABOVE ROOF SURFACE. NEC 310.15(B)(3)(c) <br />·THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITHSTAND <br />A MINIMUM 110 MPH WIND LOAD. <br />LICENSED CONTRACTOR SIGNATURE: <br />Simon Sayag