My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1834 W Third St #3 - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Third St
>
1834 W Third St Unit# 3
>
1834 W Third St #3 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/25/2025 5:00:14 AM
Creation date
12/25/2025 5:00:08 AM
Metadata
Fields
Template:
Plan
Permit Number
20187641
101126095
Full Address
1834 W Third St Unit# 3
Street Number
1834
Street Direction
W
Street Name
Third
Street Suffix
St
Unit Number
3
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-8 <br />AN <br />D <br />Y <br /> <br />M <br />A <br />I <br />18 <br />3 <br />4 <br /> <br />W <br /> <br />3 <br />R <br />D <br /> <br />S <br />T <br />, <br /> # <br />3 <br /> <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br /> <br />PH <br />O <br />N <br />E <br /> <br /># <br />: <br /> <br />N <br />/ <br />A <br />REVDATEDESCRIPTION <br />REVISIONS <br />CONTRACTOR INFORMATION <br />GREEN HILL SOLAR INC <br />7020 MIDDLESBURY RIDGE CIR., <br />WEST HILLS, CA 91307 <br />CSLB 938682, C-46 (Exp 10/31/2025) <br />PHONE: (888) 902-3551 <br />ELECTRICAL NOTES <br />1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br />2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. <br />3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND <br />LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. <br />4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY <br />WITH NEC 110.26. <br />5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL <br />NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND <br />STANDARDS. <br />6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE <br />CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br />7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br />8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT <br />RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. <br />9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO <br />GBL-4DBT LAY-IN LUG. <br />10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE <br />NUMBER OF CURRENT <br />CARRYING CONDUCTORS IN <br />EMT <br />4-6 <br />7-9 <br />10-20 <br />PERCENT OF <br />VALUES <br />.80 <br />.70 <br />.50 <br />AMBIENT TEMPERATURE SPECS <br />AMBIENT TEMP (HIGH TEMP 2%) <br />RECORD LOW TEMP 2° <br />31° <br />CONDUIT HEIGHT 7/8" <br />ROOF TOP TEMP 90° <br />CONDUCTOR TEMPERATURE RATE 90° <br />WIRING <br />CALCULATIONS <br />AC CONDUCTOR AMPACITY CALCULATIONS: <br />FROM ROOF TOP JUNCTION BOX TO IQ COMBINER BOX <br />AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT <br />EXPECTED WIRE TEMP (°C): 31° <br />TEMP CORRECTION PER TABLE 310.15: 0.96 <br />#OF CURRENT CARRYING CONDUCTORS: 2 <br />CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a): 1.0 <br />CIRCUIT CONDUCTOR SIZE: 10 AWG <br />CIRCUIT CONDUCTOR AMPACITY: 40A <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B): <br />1.25 X MAX AC OUTPUT CURRENT X # OF INVERTERS PER BRANCH <br />BRANCH A : 1.25 X 1.33 X 5 = 8.31A <br />DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.15 <br />TEMP CORR. PER NEC TABLE 310.15 X <br />CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X <br />CIRCUIT CONDUCTOR AMPACITY = 0.96 X 1.0 X 40 = 38.4A <br />AC CONDUCTOR AMPACITY CALCULATIONS: <br />FROM IQ COMBINER BOX TO SUB PANEL <br />EXPECTED WIRE TEMP (°C): 31° <br />TEMP CORRECTION PER NEC TABLE 310.15: 0.96 <br />CIRCUIT CONDUCTOR SIZE: 10 AWG <br />CIRCUIT CONDUCTOR AMPACITY: 40A <br />#OF CURRENT CARRYING CONDUCTORS: 3 <br />CONDUIT FILL PER NEC 310.15(B)(2)(a): 1.00 <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): <br />1.25 X OUTPUT CURRENT OF LOAD CENTER <br />1.25 X 1.33 X 5 = 8.31A <br />DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.15: <br />TEMP CORR. PER NEC 310.15 X <br />CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X <br />CIRCUIT CONDUCTOR AMPACITY = <br />0.96 X 1.0 X 40 = 38.4A <br />MICRO-INVERTER SPECIFICATIONS <br />MANUFACTURER / MODEL #ENPHASE: IQ8MC-72-M-US <br />NOMINAL OUTPUT CURRENT 1.33 AMP <br />RATED OUTPUT POWER 320 VAC <br /># OF PANELS x NOMINAL <br />OUTPUT CURRENT 5 x 1.33 = 6.65A <br />SOLAR MODULE SPECIFICATIONS <br />MANUFACTURER / <br />MODEL # <br />VMP <br />IMP <br />VOC <br />ISC <br />MISSION SOLAR: MSX10-435HN0B 435W <br />MODULES <br />MODULE DIMENSION <br />33.31V <br />13.07A <br />39.56V <br />13.79A <br />67.79"L x 44.64"W x 1.37"D (In Inch) <br />MODULE TEMPERATURE COEFFICIENT OF Voc -0.25%/°C <br />LICENSED CONTRACTOR SIGNATURE: <br />Simon Sayag
The URL can be used to link to this page
Your browser does not support the video tag.