137 SIGN COMPONENTS MANUAL (SAM)October 1, 2013
<br />9. Marking - The following markings or equivalent shall be provided. Markings A and B below shall be marked anywhere where
<br />readily visible during servicing.
<br />A. "Do not attempt to repair or service a damaged sign face. For servicing of this sign, contact ."(Blank to be
<br />replaced by Applicant's Company name, City and State.)
<br />B. "Replace only with , Type ." (Blanks to be replaced by Applicant's Company name and material type or designation.)
<br />SS LIGHT CO LTD
<br />7 SINPUNG-DONG PALDAL-GU
<br />E346996
<br />SUWON-SI, GYEONGGI-DO 442-040 REPUBLIC OF KOREA
<br />Class 2 LED Modules, KPL, PPL, DPL, OSPL, CPL, OCPL, SPL40, SPL4, SPL(Wl), KRD, KBD, KGD, KYD, SDL, SDL(Wl),
<br />SPL, SPLE SCPL, ODL, OPL, OPL40, OPL4, OPLA KSL(Wl), KDL(Wl), CPLOA/1), KPL40/Vl), JRGB3, KR40, KB40, KG40,
<br />CSLOA/1), CSR, CSB, CSG, WSL(V\/1), WSR, WSB, WSG, WPL-(Wl), KOL-le(Wl), KOL-2C, KOL-2C(Wl), KOR-2C, KOB-2C,
<br />KOG-2C, GPL, GPL(V\/1), GRGBD, GRGB), GRGB40, JGRGB), GCS RGB, WGS RGB, WGRGB3, SSL(Wl), SCPL(Wl),
<br />SPL40(Wl), JSRGB3, SCSL, SCSL(Wl), SCS RGB, WSSL, WSSLOA/1), WSS RGB, WSPL(Wl), WSL, GDL, GPL40, GPL40(W),
<br />EPL, GCPL, OPCB 5030 6 (38, OPCB 5030 8 OP), PCB 5030 6 (1 P), PCB 5030 8 (3P), PCB 5030 6 (1 P) KP1, PCB 5030 8 (3P)
<br />KP1, PCB 5030 6 (1 P) KWL PCB 5030 8 (3P) KWL RGB 5030 8 OP), LRGB 5030 10 (313, PCB 5030 OP) R, PCB 5030 (3P) B,
<br />PCB 5030 (3P) G, PCB 4530 - le (213, PCB 4530 Wl - le (219, PCB 4530 R - le (2P), PCB 4530 8 - le (2P), PCB 4530 G - 1C
<br />(2P)m PCB 4545 - 2C (3P), PCB 4545 Wl - 2C (3P), PCB 4545 R - 2C (3P), PCB 4545 B - 2C (3P), PCB 4545 G - 2C (3P), GPCB
<br />5030 8 OP), GPCB 5030 8 (38 W, GRGB 5030 8 (38, LGRGB 5030 10 (3P), SPCB 5030 8 (38, SPCB 5030 8 OP) W, A/L S 18,
<br />A/L S30, A/L S60, A/L PP 18, An- PP30, A/L PP60, A/L 318 (Wl), A/L S30 (Wl), A/L S60 (Wl), A/L PP18 (Wl), A/L PP30
<br />(Wl), A/L PP60 (Wl), A/L S18(R), A/L S30(R), A/L S60(R), A/L PP18(R), A/L PP30(R), A/L PP60(R), A/L S18(B), A/L
<br />S30(B), A/L S60(B), A/L PP18(B), A/L PP30(B), A/L PP60(B), A/L 618(G), A/L S30(G), A/L S60(G), A/L PP 18(G), A/L
<br />PP30(G), A/L PP60(G), A/L RGB S18, A/L RGB S30, A/L RGB S60, A/L RGB P18, A/L RGB P30, A/L RGB P60, A/L GS18, A/L
<br />GS30, A/L GS60, A/L GPP18, A/L GPP30, A/L GPP60, A/L GS18 (Wl), All GS30 (Wl), A/L GS60 (Wl). Al GPP18 (Wl),
<br />Al GPP30 (Wl), Al GPP60 (Wl), A/L GRGB S18, A/L GRGB S30, A/L GRGB S60, A/L GRGB P18, A/L GRGB P30, A/L
<br />GRGB P60, All SS18, Al SS30, Al SS60, Al SPP18, A/L SPP30, A/L SPP60, A/L SS18 (Wl), A/L SS30 (Wl), A/L SS60
<br />(wl), A/L SPP18 (Wl),A/L SPP30 (Wl), A/L SPP60 (Wl), WAL PP18, WAL PP30, WAL PP60, WAL PP18 (Wl),AL PP30
<br />(Wl), WAL PP60 0/VI) WAL PP18(R), WAL PP30(R), WAL PP60(R), WAL PP18(B), WAL PP30(B), WAL PP60(B), WAL
<br />PP18(G), WAL PP30(G), WAL PP60(G), WAL RGB P18, WAL RGB P30, WAL RGB P60, WAL GPP18, WAL GPP30, WAL
<br />GPP60, WAL GPP18 (Wl ), WAL GPP30 (Wl), WAL GPP60 (Wl), WAL GRGB P18, WAL GRGB P30, WAL GRGB P60, WAL
<br />SPP18, WAL SPP30, WAL SPP60, WAL SPP18 (Wl), WAL SPP30 (Wl), WAL SPP60 (Wl)
<br />1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less.
<br />2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy
<br />limited circuit and is rated greater than 12V DC.
<br />3. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output
<br />rating of the Class 2 supply.
<br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volts DC or less.
<br />5. These products are not required to be enclosed or protected from the weather in the end product.
<br />6. These products may be secured in place in the end product by any means available.
<br />Marking: Company name or trademark SS LIGHT and product designation.
<br />STARTEC CO LTD E350879
<br />310-8 YUHYUN-RI
<br />YANGCHON-MYEON
<br />GIMPO-SI, GYEONGGI-DO 415-821 REPUBLIC OF KOREA
<br />Class 2 LED Module, R03-25KN.
<br />1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less.
<br />2. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output
<br />rating of the Class 2 supply.
<br />3. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volts DC or less.
<br />4. These products are not required to be enclosed or protected from the weather in the end product.
<br />5. These products may be secured in place in the end product by any means available.
<br />SUNSIGNLED OPTO-ELECTRONICS CO LTD
<br />2F BLDG B LAOBING INDUSTRY PARK
<br />ZHOUSHIRD
<br />SHIYAN TOWN BAOAN DISTRICT
<br />E359615
<br />518108 SHENZHEN, CHINA
<br />Class 2 powered LED modules, Models IYX225U, IY)(324U, IYX220U, IYX340U, IYX326U, IYX332U, IYX341 U, MYX1 12U,
<br />MY)(120U, MYX 102U, MY)<117U, where X and Y may be replaced by any letter denoting LED color and type respectively.
<br />1. This product is only suitable for connection to a Class 2 power source, rated 12 Volt DC or less.
<br />2. This product has not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and
<br />energy limits and which is rated greater than electrical ratings.
<br />3. This Class 2 LED module is rated as noted in the electrical ratings tables. When units are connected to a Class 2 circuit, they
<br />are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply.
<br />4. This product is suitable for use in dry, damp and wet locations with supply sources rated at electrical ratings or less.
<br />5. This product is not required to be enclosed or protected from the weather in the end product.
<br />6. This product may be secured in place in the end products by any means available.
|