WIRE/CO'NDUIT SCHEDULE <br />NUMBEROF <br />TAG DESCRIPTION CONDUCTOR TYPE/SIZE CONDUCTORS CONDUIT SIZE/TYPE <br />1 ARRAY TO JUNCTION BOX #10 AWG PV WIRE 4 N/A <br />2 JUNCTION BOX TO INVERTER #10 AWG THWN-2 4 l' EMT <br />3 INVERTER TO ITRON METER #8 AWG THWN-2 3 f' EMT <br />4 ITRON METER TO AC DISCONNECT#8 AWG THWN-2 3 + EMT <br />5 AC DISCONNECT TO MSP #8 AWG THWN-2 3 1" EMT <br />6 EQUIPMENT GROUND #8 AWG SOLID COPPER 1 N/A <br />7 EQUIPMENT GROUND #8 AWG THWN-2 1 t EMT <br />GENERAL ELECTRICAL NOTES: <br />MPPT 1 DETAILS MPPT 2 DETAILS <br />NOTES NO. OF MODULE PER STRING 11 No. OF MODULE PER STRING 11 <br />FREE AIR NO. OF STRINGS 1 NO. OF STRINGS 1 <br />ARRAY WATTS AT STC 2.750kW ARRAY WATTS AT STC 2.750kW <br />MAX. VOLTAGE 441.2V MAX. VOLTAGE 441.2V <br />MODULE SPECIFICATION <br />CANADIAN SOLAR <br />MODEL NO.CS6P-250P <br />PEAK POWER 250W <br />RATED VOLTAGE (Vmp)30.1V <br />RATED CURRENT (Imp)8.30A <br />OPEN CIRCUIT VOLTAGE (Voc)37.2V <br />SHORT CIRCUIT CURRENT (ls©8.87A <br />INVERTER SPECIFICATION <br />1. EQUIPMENT USED SHALL BE NEW, UNLESS OTHERWISE NOTED. <br />2. EQUIPMENT SHALL BE INSTALLED PROVIDING ADEQUATE PHYSICAL <br />WORKING SPACE;AROUND THE EQUIPMENT AND SHALL COMPLY WITH <br />NEC. <br />3. COPPER CONDUCTORS SHALL BE USED AND SHALL HAVE INSULATION <br />RATING 600V, 90°C, UNLESS OTHERWISE NOTED. <br />4. CONDUCTORS SHALL BE SIZED IN ACCORDANCE TO NEC. <br />CONDUCTORS AMPACITY SHALL BE DE-RATED FOR TEMPERATURE <br />INCREASE, CONDUIT FILL AND VOLTAGE DROP. <br />5. ALL CONDUCTORS, EXCEPT USE-2, SHALL BE INSTALLED IN APPROVED <br />CONDUITS OR RACEWAY. CONDUITS SHALL BE ADEQUATELY <br />SUPPORTED AS PER NEC. <br />6. RACKING AND MODULES ARE GROUNDED VIA A CONTINUOUS #10 AWG <br />COPPER CONDUCTOR, GROUNDING CLOPS, GROUNDING LUGS AND/OR <br />BONDING JUMPERS. <br />7. LOAD SIDE INTER-CONNECTION SHALL COMPLY WITH NEC <br />8. SMOKE ALARM AND CARBON MONOXIDE DETECTORS SHALL BE <br />LOCATED AS REQD PER' SEC. R314 & R315 OF THE CALIFORNIA <br />RESIDENTIAL CODE (CRC) <br />9. ALL EQUIPMENT SHALL BE LISTED FOR THE APPLICATION, UL 1703 FOR <br />MODULES, UL 1741 FOR INVERTERS <br />INVERTER MAKE POWER-ONE - <br />INVERTER MODEL PVI-5000-OUTD-US 8 r <br />>r- n <br />MAX. DC VOLT RATING 600V <br />MAX. AC APPARENT POWER 5000W <br />NOMINAL AC VOLTAGE 240V CE CO <br />00 <br />MAO< AC CURRENT 23A <br />UTILITY <br />81-DIRECTIONAL <br />ELECTRIC METER ti <br />go <br />vo <br />111 U.1 m -r <br />5>ZO. <br />EXISTING MAIN SERVICE PANEL 2£ S Ul .· <br />125A, 240VAC, 1 PH 711.11< < <br />'\ O\ NEW -O kz( <br />\__jMCB 6-1 0<C! <br /> j 100A Wz is, <br />9592; <br />PVI-5000-OUTD-US <br />DCINTERFACE POWER-ONE <br />INTEGRATED DE 5.OKW, 96.5% CEC <br />DISCONNECT 240VAC. 23A ACINTERFACE <br />DC+ <br />IRIMPPT 1 Ll - <br />''MPPT 21le L2 C <br />DC- <br />19'Mper 11 Llc <br />V <br />DEDICATED PHOTOVOLTAIC <br />POWER SYSTEM <br />KILOWATT-HOUR METER <br />100A. 240VAC. FORM ZS <br />ACDISCONNECT <br />240VAC, 3OA <br />LU NEMA 3R, UL LISTED <br />J-BOX 30A <br />NEMA 3R -*T--1 <br />1 <br />7 KWMI 1 <br />A <br />UJ <br />l METER J <br />1- g 1921 DVI <br />7 <br />U <br />EMPPT 2 <br />--1.--- - <br />V V <br />5 GND <br />N L.2 Ll <br />-1- EXISTING <br />-:- GROUND <br />PV 3