GROUND-FAULT DETECDON AND INTERRUPTION <br />TO BE INSTALLED AT INVERTER PER <br />NEC 2008 690.5 (C) <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />IF A GROUND FAULT IS INDICATED, <br />NORMALLY GROUNDED CONDUCTORS <br />MAY BE UNGROUNDED AND ENERGIZED <br />DISCONNECTION MEANS; TO BE INSTALLED <br />AT ALL AC AND DC DISCONNECTS <br />RESPECTIVELY PER NEC 2008 690.14(C)(2) <br />SOLAR AC DISCONNECT <br />SOLAR DC DISCONNECT <br />DISCONNECTING MEANS MAY BE ENERGIZED IN <br />THE OPEN POSmON; TO BE INSTALLED <br />AT DISCONNECTING MEANS <br />PER NEC 2008 690.17 <br />INVERTER OUTPlJT CONNECTION TO BE <br />INSTALLED AT MAIN SERVICE PANEL <br />PER NEC 2008 690.64 (B)(7) <br />WARNING <br />INVERTER OUTPUT CONNECTION <br />DO NOT RELOCATE <br />THIS OVERCURRENT DEVICE LOCACTED <br />ADJACENT TO BACKFED BREAKER <br />MARKING SHOULD BE PLACED ON ALL <br />INTERIOR AND EXTERIOR PV CONDUIT, <br />RACEWAYS, ENCLOSURES, AND CABLE <br />ASSEMBLIES, EVERY 10 FEET, AT TURNS AND <br />ABOVE AND/OR BEU)W PENETRATIONS AND <br />All PV COMBINER AND JUNCTION BOXES. <br />0 SHALL BE REFLECTIVE WEATHER <br />RESISTANT MATERIAL <br />CAUTION: SOLAR CIRCUIT <br />TO BE LOCATED AT MAIN SERVICE PANEL: <br />CAUTION: <br />MAX PV VOLTAGE & CURRENT CALC'S: <br />RECORD LOW TEMP. CC): -5 <br />VOLTAGE CORRECnON PER NEC 690.7: 1.12 <br />MAX PV SYSTEM VOLTAGE (PER NEC 690.7): <br />Vcorrection X Voc X # MODULES IN SERIES <br />1.12 X 38.40 X9= 387.07V <br />MAX PV CURRENT PER NEC 690.8(A)(1): <br />1.25 X Isc <br />1.25 X 8.79 = 10.99A <br />DC CONDUCTOR AMPACITY CALCULATIONS: <br />ARRAY TO JUNCTION BOX <br />EXPECTED WIRE TEMP ('C): 88' <br />TEMP CORRECnON PER TABLE 310.16: 0.91 <br /># OF CURRENT CARRYING CONDUCTORS: 4 <br />CONDUIT FILL CORRECPON PER NEC 310.15(B)(2)(a): 0.8 <br />CIRCUIT CONDUCTOR SIZE: 10 AWG <br />CIRCUIT CONDUCTOR AMPACITY: 40 A <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(UB): <br />1.25 X 1.25 X Isc = <br />AC CONDUCTOR AMPACITY CALCULATIONS: <br /># OF INVERTERS: 1 <br />EXPECTED WIRE TEMP ¢C): 88' <br />TEMP CORRECTION PER NEC TABLE 310.16: 0.91 <br />CIRCUIT CONDUCTOR SIZE: 10 AWG <br /># OF CURRENT CARRYING CONDUCTORS: 3 <br />CONDUIT FILL PER NEC 310.15(B)(2)(a): 1 <br />CIRCUIT CONDUCTOR AMPACITY: 40 A <br />REQUIRED CIRCUIT CONDUCTOR AMPACHY PER NEC 690.8(B): <br />1.25 X MAX INVERTER OUTPUT CURRENT= <br />1.25 X 16.00 = 20.00 A <br />DERATED AWACITY OF aRCL.ff CONDUCTOE PER FEC TABLE 310.1& <br />TEMP CORR. PER NEC 310.16 X <br />CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X <br />CIRCUIT CONDUCTOR AMPACITY = <br />0.91 X1X40= 36.40 A <br />WARNING <br />ELECTRIC SHOCK HAZARD. <br />DO NOT TOUCH TERMINALS. <br />TERMINALS ON BOTH THE UNE AND <br />LOAD SIDE MAY BE ENERGIZED <br />IN THE OPEN POSmON. <br />PHOTOVOLTAIC POWER SOURCE SHALL BE <br />LABELED WITH THE FOLLOWING WARNING AT <br />EACH JUNCTION BOX, COMBINER BOX, <br />DISCONNECT, AND DEVICE WHERE ENERGIZED, <br />UNGROUNDED CIRCUITS MAY BE EXPOSED <br />DURING SERVICE PER NEC690.35(F) <br />WARNING <br />ELECTRIC SHOCK HAZARD. <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE <br />UNGROUNDED AND MAY BE ENERGIZED <br />DIRECT-CURRENT PHOTOVOLTAIC POWER <br />SOURCE TO BE INSTALLED AT <br />INVERTER PER NEC 690.53 & 690.54 <br />MAX INVERTER OUTPUT 3.6KW, 164 240VAC <br />OPERATING CURRENT: 8A <br />OPERARNG VOLTAGE: 273V <br />SHORT-CIRCUIT CURRENT: 1 OA <br />MAX SYSTEM VOLTAGE: 387V <br />SOLAR ELECTRIC SYSTEM CONNECTED <br />TO BE INSTALLED ON THE FACE OF THE <br />SERVICE METER PANEL PER <br />NEC 2008 705.10 <br />CAUTION: <br />POWER TO THIS BUILDING IS ALSO SUPPUED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN <br />AT: 1 <br />METER AND MAIN SERVICE <br />R AC DISCONNECT <br />Ill'lll'lll.Ill DC DISCONNECT <br />'·'.[[[O INVERTER <br />09 % <br />9 <br />54 <br />MARKING CONTENT AND FORMAT <br />o RED BACKGROUND <br />o WHITE LETTERING <br />o MINIMUM 3/80 LETTER HEIGHT <br />u ALL CAPITAL LETTERS <br />0 ARIAL OR SIMILAR FONT, NON-BOLD <br />o WEATHER RESISTANT MATERIAL <br />SUITABLE FOR THE ENVIRONMENT <br />(DURABLE ADHESIVE MATERIALS MUST <br />MEET THIS REQUIREMENT <br />1.25 X 1.25 X 8.79 = 13.73A <br />DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 <br />TEMP CORR. PER NEC TABLE 310.16 X <br />CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X <br />CIRCUIT CONDUCTOR AMPACITY = <br />0.91 X 0.8 X 40 = 29.12A <br />DC CONDUCTOR AMPACITY CALCULATIONS: <br />FROM JUNCTION BOX TO INVERTER <br />AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT <br />PER NEC 310.15(B)(2)(c): + 22' <br />EXPECTED WIRE TEMP CC): 41' + 22' <br />TEMP CORRECION PER TABLE 310.16: 0.58 <br /># OF CURRENT CARRYING CONDUCTORS: 4 <br />CONDUIT FILL CORRECnON PER NEC 310.15(B)(2)(a): 0.8 <br />CIRCUIT CONDUCTOR SIZE: 10 AWG <br />CIRCUIT CONDUCTOR AMPACITY: 40 A <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B): <br />1.25 X 1.25 X Isc <br />1.25 X 1.25 X 8.79 = 13.73 A <br />DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 <br />TEMP CORR. PER NEC TABLE 310.16 X <br />CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X <br />CIRCUIT CONDUCTOR AM PACITY = <br />0.58 X 0.8 X 40 = 18.56 A <br />PV-4 <br />C.\Uiers\Icid\appdato\local\temp\AcPublish_7948\Dletz (Sonto Ano) SO-13-12-143.dwg Jan 16, 2014 - 9 42am $(GETVAR,?9) »Id <br />F: <br />® <br />101 <br />® <br />0 <br />bIUNAGE & NO I ES <br />Lic.#935263,4 <br />QI 1 <br />18 2ve -0 e em r