Laserfiche WebLink
MA <br />X <br />. <br />1/ <br />4 <br />" <br />. <br />MA <br />X <br />. <br />1/ <br />4 <br />" <br />. <br />MA <br />X <br />. <br />1/ <br />2 <br />" <br />. <br />MA <br />X <br />. <br />1/ <br />4 <br />" <br />. <br />(a) <br />vertical change in level <br />(b) <br />beveled change in level <br />2 <br />1 <br />PLATFORM OF APPROVED <br />MATERIALS TO RAISE FLOOR <br />LEVEL OF BALCONY; <br />PLATFORM REQUIRED FOR <br />FINAL INSPECTION <br />MA <br />X <br />. <br />1" <br />. <br />MA <br />X <br />. <br />3/ <br />4 <br />" <br />. <br />2 <br />1 <br />8" MIN. <br />PERMANENTLY <br />INSTALLED RAMP <br />EXTERIOR <br />IMPERVIOUS <br />SURFACE <br />SECONDARY EXTERIOR DOOR <br />THRESHOLD <br />INTERIOR FLOOR LEVEL <br />door <br />REQUIRED <br />DIM. AS <br />REQUIRED <br />DIM. AS <br />RANGE <br />see <br />requirement for <br />functional clear <br />space when <br />door is open <br />COOK TOP <br />forward approach <br />allowed when knee <br />& toe space is <br />provided under the <br />cooktop <br />(a) <br />parallel approach <br />MIN. <br />2'-0" <br />MIN. <br />2'-0" <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />. <br />parallel approach <br />CLCL <br />CL <br />CLMIN. <br />2'-2" <br />CL <br />CL <br />CL <br />U.N.O. <br />37" CLEAR <br />REFRIGERATOR <br />additional clearance <br />required when a <br />wall extends past <br />the face of the <br />appliance <br />clearance required when a wall or cabinet <br />return extends past the face of the appliance <br />door door door <br />REQUIRED <br />DIM. AS <br />REQUIRED <br />DIM. AS <br />REQUIRED <br />DIM. AS <br />U.N.O. <br />33" MIN. <br />WALL OR <br />MICROWAVE OVEN <br />see requirement for <br />functional clear space <br />when door is open <br />DISHWASHER <br />see requirement for <br />functional clear space <br />when door is open <br />TRASH COMPACTOR <br />see requirement for <br />functional clear space <br />when door is open <br />KITCHEN SINK <br />removable base <br />cabinets required see <br />figure 33.4 <br />(b) <br />parallel or forward approach <br />MIN. <br />1'-3". <br />MIN. <br />1'-3". <br />forward <br />approach <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />. <br />when a garbage disposal is provided, <br />the sink drain shall be located to the <br />rear of the sink so the disposal can <br />be mounted clear of the required <br />knee & toe space. <br />provide knee and toe space <br />aligned with the forward <br />clear floor space per figure <br />16.3 <br />work surface area <br />(shown cross-hatched) <br />WORK SURFACE <br />removable base <br />cabinets required see <br />figure 33.4 <br />FHA requires functional space at all appliances with a pull <br />out or pull down door. The clear floor space of adjacent <br />appliances and the 36" wide accessible path through the <br />kitchen can be combined to provide functional clear floor <br />space. At appliances with a pull down door, either a <br />parallel front approach or parallel side approach using a 9" <br />high toe space under the door when it is pulled down can <br />be used. See figure 33.2 (2) for additional information. <br />pa <br />r <br />a <br />l <br />l <br />e <br />l <br /> <br />fr <br />o <br />n <br />t <br />pa <br />r <br />a <br />l <br />l <br />e <br />l <br /> <br />si <br />d <br />e door <br />REQUIRED <br />MIN. AS <br />SPECIFIED APPLIANCE <br />functional space required <br />when appliance has a pull <br />out or pull down door <br />(c) <br />functional clear space <br />CL <br />CL <br />VE <br />R <br />I <br />F <br />Y <br />CLEAR <br />3'-6".6" <br />CL <br />E <br />A <br />R <br /> <br />W <br />I <br />D <br />T <br />H <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />CLEAR WIDTH <br />48" MIN. <br />36" MIN. <br />CLEAR PATH <br />36" MIN. <br />MI <br />N <br />. <br />12 <br />" <br />. <br />WI <br />D <br />T <br />H <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />E <br />A <br />R <br />CL <br />E <br />A <br />R <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />CL <br />E <br />A <br />R <br /> <br />W <br />I <br />D <br />T <br />H <br />60 <br />" <br /> <br /> <br />M <br />I <br />N <br />. <br />TWO -15" BREAD BOARDS (CB) <br />MAY BE PROVIDED IN LIEU OF <br />THE 30" COUNTERTOP WORK <br />SURFACE WITH KNEE AND TOE <br />SPACE OR REPOSITIONING THE <br />WORK SURFACE COUNTERTOP <br />WHEN REQUIRED BY 1133.A4.1 <br />A 60" DIAMETER TURNING <br />CIRCLE OR T-SHAPED <br />TURNING SPACE IS <br />REQUIRED AT THE BASE OF <br />U-SHAPED KITCHENS <br />SEE FIGURE 33.2(3) BELOW <br />FOR ADDITIONAL <br />INFORMATION <br />36" MIN. <br />MI <br />N <br />. <br />1' <br />- <br />2 <br />" <br />A MINIMUM 48" OF CLEAR WIDTH <br />IS REQUIRED WHEN A SINK OR <br />A COOK TOP WITH THE <br />REQUIRED KNEE AND TOE <br />SPACE IS PROVIDED AT THE <br />BASE OF U-SHAPED KITCHENS <br />WHEN A DOOR TO AN APPLIANCE IS <br />OPEN, FUNCTIONAL CLEAR FLOOR <br />SPACE MUST BE PROVIDED. THE <br />FORWARD APPROACH TO THE SINK <br />PROVIDES THE PARALLEL FRONT <br />APPROACH TO DISHWASHER WHEN <br />IT'S DOOR IS OPEN; SEE FIGURE 16.1 <br />FOR ADDITIONAL INFORMATION. <br />SEE FIGURE 33.2(3) BELOW <br />FOR ADDITIONAL <br />INFORMATION <br />36" MIN. <br />TYPICAL OUTLET AND/OR SWITCH <br />PLACEMENT FOR SIDE APPROACH <br />ACCESS WHEN TOP OF <br />RECEPTACLE BOX IS MOUNTED NO <br />HIGHER THAN 46" ABOVE THE <br />FINISH FLOOR <br />TYPICAL OUTLET LOCATION <br />REQUIRED BY C.E.C. <br />MI <br />N <br />. <br />12 <br />" <br />. <br />MI <br />N <br />. <br />24 <br />" <br />. <br />RANGE DISHWASHER <br />DOOR <br />PA <br />R <br />A <br />L <br />L <br />E <br />L <br /> <br />FR <br />O <br />N <br />T <br />REF <br />WORK <br />SURFACE <br />SI <br />N <br />K <br />(3) ALL OTHER KITCHEN DESIGNS <br />(SEE FIGURE 33.1 FOR CLEAR FLOOR SPACE REQUIREMENTS AT FIXTURES <br />AND APPLIANCES FOR ALL CLEAR WIDTH FIGURES) <br />(2) U-SHAPE KITCHEN WITH A <br />COOKTOP OR SINK LOCATED AT <br />THE BASE OF THE U <br />(1) U-SHAPE KITCHEN WITH PARALLEL <br />APPROACH AT RANGE OR COOKTOP <br />LOCATED AT THE BASE OF THE U <br />REF <br />WORK <br />SURFACE <br />DISH- <br />WASHER SINK <br />RA <br />N <br />G <br />E <br />SINK <br />RA <br />N <br />G <br />E <br />WO <br />R <br />K <br /> <br />SU <br />R <br />F <br />A <br />C <br />E <br />DISHWASHER <br />REF <br />CLEAR WIDTH <br />48" MIN. <br />SINKS WITH REAR LOCATED DRAINS <br />SIMPLIFY KNEE SPACE REQUIREMENTS <br />OF FIGURE <br />THE SIDES OF ADJACENT CABINETS AND <br />THE BACK WALL, WHICH MAY BECOME <br />EXPOSED TO MOISTURE OR FOOD <br />HANDLING WHEN A COUNTERTOP IS <br />LOWERED, SHALL BE CONSTRUCTED OF <br />DURABLE, NONABSORBENT MATERIALS. <br />CABINETS TO BE REMOVABLE WITHOUT <br />THE USE OF SPECIALIZED TOOLS OR <br />KNOWLEDGE <br />EXTEND FINISH FLOOR BENEATH THE <br />KITCHEN SINK COUNTER AREA TO THE WALL <br />25" MAX. <br />MIN. <br />8". <br />MI <br />N <br />. <br />9" <br />. <br />27 <br />" <br /> <br />M <br />I <br />N <br />. <br />co <br />m <br />m <br />o <br />n <br /> <br />a <br />r <br />e <br />a <br /> <br />k <br />i <br />t <br />c <br />h <br />e <br />n <br />s <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />dw <br />e <br />l <br />l <br />i <br />n <br />g <br /> <br />u <br />n <br />i <br />t <br /> <br />k <br />i <br />t <br />c <br />h <br />e <br />n <br />s <br />36 <br />" <br /> <br />M <br />A <br />X <br />. <br />toe <br />knee/apron <br />countertop <br />19" MAX. <br />11" MIN. <br />FAUCET CONTROLS PER 1133A.6 <br />KNEE AND TOE SPACE PER 1133A.7 <br />(SHOWN SHADED) <br />PLUMBING PROTECTION PER <br />1133A.7.1 AT HOT WATER AND <br />DRAIN PIPES PROVIDE <br />INSULATION OR REMOVABLE <br />APPEARANCE PANEL <br />PROTECTION FROM HOT <br />SURFACES <br />WHEN A GARBAGE DISPOSAL IS <br />PROVIDED, THE SINK DRAIN SHALL <br />BE LOCATED TO THE REAR OF THE <br />SINK SO THE DISPOSAL CAN BE <br />MOUNTED CLEAR OF THE <br />REQUIRED KNEE & TOE SPACE. <br />OPENING <br />32" MIN. <br />DOOR WIDTH <br />36" MIN. <br />OPENING <br />32" MIN. <br />44 <br />" <br /> <br />M <br />I <br />N <br />. <br />DOOR AND LANDING WIDTH <br />36" MIN. <br />36" MIN. <br />32" MIN. <br />42 <br />" <br /> <br /> <br />M <br />I <br />N <br />. <br />1'-6" <br />42 <br />" <br /> <br /> <br />M <br />I <br />N <br />. <br />3'-2" <br />2'-10" <br />3' <br />- <br />3 <br /> <br />1 <br />/ <br />4 <br />" <br />1'-6" <br />3' <br />- <br />3 <br />" <br />EXTERIOR WALL SIDE <br />SEE 26/A-3.30.1 <br />(A) <br />INTERIOR DOOR OR SECONDARY <br />EXTERIOR DOOR <br />(B) <br />EXCEPTION 1 <br />36 <br />" <br /> <br />M <br />I <br />N <br />. <br />30 <br />" <br /> <br />M <br />I <br />N <br />. <br />12" MAX. <br />60" MIN. <br />BACK WALL <br />SI <br />D <br />E <br /> <br />W <br />A <br />L <br />L <br />CO <br />N <br />T <br />R <br />O <br />L <br /> <br />E <br />N <br />D <br />SI <br />D <br />E <br /> <br />W <br />A <br />L <br />L <br />(1.2) <br />30"X60" SHOWER STALL <br />(WITH WATER CLOSET PROJECTION SHOWN) <br />36 <br />" <br /> <br />M <br />I <br />N <br />. <br />3' <br />-3" <br /> <br />M <br />I <br />N <br />. <br /> <br />W <br />I <br />T <br />H <br /> <br />SH <br />O <br />W <br />E <br />R <br /> <br />D <br />O <br />O <br />R <br />BACK WALL <br />SI <br />D <br />E <br /> <br />W <br />A <br />L <br />L <br />CO <br />N <br />T <br />R <br />O <br />L <br /> <br />E <br />N <br />D <br />SI <br />D <br />E <br /> <br />W <br />A <br />L <br />L <br />60" MIN. <br />36 <br />" <br /> <br />M <br />I <br />N <br />. <br />3' <br />-3" <br /> <br />M <br />I <br />N <br />. <br /> <br />W <br />I <br />T <br />H <br /> <br />SH <br />O <br />W <br />E <br />R <br /> <br />D <br />O <br />O <br />R <br />(1.3) <br />30"X60" SHOWER STALL WITH 36" ENTRANCE OPENING <br />54 <br />" <br /> <br />( <br />F <br />H <br />A <br /> <br />S <br />E <br />A <br />T <br />) <br />6" <br />3'-0" MIN. <br />3'-3" MIN. WITH <br />SHOWER DOOR <br />48" MIN. <br />CONTROL SIDE WALL <br />42 <br />" <br /> <br />M <br />I <br />N <br />. <br />BA <br />C <br />K <br /> <br />W <br />A <br />L <br />L <br />op <br />e <br />n <br />i <br />n <br />g <br />34 <br />" <br /> <br />c <br />l <br />e <br />a <br />r <br />SIDE WALL <br />(SEAT SIDE FHA) <br />(1.1) <br />42"X48" SHOWER STALL WITH <br />36" ENTRANCE OPENING <br />SHOWER DOOR SHALL <br />PROVIDE 34" CLEAR <br />OPENING WHEN DOOR IS <br />OPEN AT 90 DEGRESS <br />ADDITIONAL CLEAR SPACE <br />REQUIRED TO ALLOW FOR <br />SIDE TRANSFER TO FUTURE <br />SEAT (FHA) <br />REINFORCE FULL WIDTH OF <br />SHOWER FOR FUTURE WALL <br />MOUNTED SEAT STARTING AT <br />THE FLOOR TO A HEIGHT OF <br />2'-0" (FHA) <br />MAX. <br />2'-0". <br />6' <br />- <br />4 <br />" <br />3' <br />- <br />8 <br />" <br /> <br />M <br />A <br />X <br />. <br />shower stall walls <br />full width at all <br />CONTROL END SIDE WALL <br />(C) <br />GRAB BAR REINFORCEMENT FOR ADAPTABLE SHOWERS <br />38 <br />" <br /> <br />M <br />I <br />N <br />. <br />32 <br />" <br /> <br />M <br />A <br />X <br />. <br />MI <br />N <br />. <br />6" <br />CL <br />MAX. <br />2'-0".CL <br />6' <br />- <br />4 <br />" <br />24" MIN. <br />3' <br />- <br />8 <br />" <br />24" MIN. <br />32 <br />" <br /> <br />M <br />A <br />X <br />. <br />CONTROL END (FOOT) WALL HEAD END WALL <br />(B) <br />GRAB BAR REINFORCEMENT FOR ADAPTABLE BATHTUBS <br />BACK WALL SIDE WALL <br />(A) <br />GRAB BAR REINFORCEMENT FOR ADAPTABLE WATER CLOSETS <br />40" MIN. <br />1'-4" <br />MI <br />N <br />. <br />1' <br />- <br />4 <br />" <br />32 <br />" <br /> <br />M <br />A <br />X <br />. <br />38 <br />" <br /> <br />M <br />I <br />N <br />. <br />38 <br />" <br /> <br />M <br />I <br />N <br />. <br />MAX. <br />1'-0"42" MIN. <br />MIN. <br />2'-2". <br />32 <br />" <br /> <br />M <br />A <br />X <br />. <br />PROVIDE ADDITIONAL BACKING FOR <br />FOLD AWAY GRAB BAR WHEN <br />REQUIRED BY 1134A.7 ITEM 2; VERIFY <br />REQUIREMENT WITH SELECTED <br />MANUFACTURER <br />BACK WALL <br />BACK WALL SIDE WALL <br />MAX. <br />6" 48" MIN. <br />MAX. <br />6" <br />6" <br /> <br />M <br />I <br />N <br />. <br />MA <br />X <br />. <br />6" <br />18" MAX. <br />16" MIN. <br />MIN. <br />1'-6" <br />36" MIN. <br />MAX. <br />1'-0" <br />48" MIN. <br />2' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />. <br />36 <br />" <br /> <br />M <br />I <br />N <br />. <br />TU <br />B <br /> <br />A <br />C <br />C <br />E <br />S <br />S <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />48" MIN. <br />MA <br />X <br />. <br />2' <br />- <br />0 <br />" <br />. <br />24" MIN.36" MIN. <br />MAX. <br />1'-0"18" MAX. <br />16" MIN. <br />MIN. <br />1'-6" <br />40" REINFORCED WALL <br />FOR REQUIRED GRAB <br />BAR REINFORCING <br />OVER RIDES 36" MIN. <br />SHOWN; SEE FIGURE <br />FOLD AWAY GRAB <br />BAR REQUIRED AT <br />WATER CLOSET <br />ADJACENT TO <br />TUB; SEE FIGURE <br />.. <br />. <br />TH <br />R <br />E <br />S <br />H <br />O <br />L <br />D <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />1/ <br />2 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />A <br />T <br /> <br />P <br />R <br />I <br />M <br />A <br />R <br />Y <br /> <br />DO <br />O <br />R <br /> <br />3 <br />/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />A <br />T <br /> <br />SE <br />C <br />O <br />N <br />D <br />A <br />R <br />Y <br /> <br />D <br />O <br />O <br />R <br />1/ <br />2 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />F <br />L <br />O <br />O <br />R <br />LE <br />V <br />E <br />L <br /> <br />C <br />H <br />A <br />N <br />G <br />E <br />1/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br />VE <br />R <br />T <br />I <br />C <br />A <br />L <br />RI <br />S <br />E <br />1 2 <br />INTERIOR LANDING <br />(FINISH FLOOR) <br />PRIMARY OR SECONDARY <br />EXTERIOR DOOR <br />DOOR THRESHOLD HARDWARE <br />CHANGES GREATER THAN 1/4" <br />SHALL BE BEVELED 1:2 <br />EXTERIOR LANDING 1/4":12" <br />MAXIMUM SLOPE AWAY FROM <br />THE DOOR <br />FLOOR LEVEL TRANSITION <br />HARDWARE CHANGES GREATER <br />THAN 1/4" SHALL BE BEVELED 1:2 <br />38 <br />" <br />- <br />4 <br />0 <br />" <br /> <br />34 <br />" <br />- <br />4 <br />4 <br />" <br />44 <br />" <br /> <br />M <br />A <br />X <br />. <br />44 <br />" <br /> <br />M <br />A <br />X <br />. <br />42 <br />" <br /> <br />P <br />R <br />E <br />F <br />E <br />R <br />R <br />E <br />D <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />60 <br />" <br /> <br />M <br />A <br />X <br />. <br />78 <br />" <br /> <br />M <br />I <br />N <br />. <br />10 <br />" <br /> <br />M <br />I <br />N <br />. <br />HARDWARE DEADBOLT <br />FIN. FLR.PR <br />E <br />F <br />E <br />R <br />R <br />E <br />D <br />VIEW <br />PORT <br />LOW ** <br />PUSH BUTTON * <br />VIEW PORT HIGH ** <br />BOTTOM OF DOOR CLOSER <br />SMOOTH BOTTOM KICK PLATE MAY OCCUR 16 GA <br />MAX, ANY CAVITIES CREATED SHALL BE CAPPED <br />NO PROJECTIONS INTO CLEAR OPENING BELOW 34"; A <br />MAXIMUM 4" PROJECTION IS ALLOWED ABOVE 34" <br />* REQUIRED AT ACCESSIBLE/ADAPTABLE DWELLING UNITS <br />** IF PROVIDED INSTALL TWO VIEW PORTS; ONE HIGH AND ONE LOW <br />AT ACCESSIBLE/ADAPTABLE DWELLING UNITS <br />. <br />970 W. 190TH ST. SUITE 250 <br />Torrance, California 90502 <br />310.217.8885 <br />D E S I G N <br />BSB <br />www.bsbdesign.com <br />REVISIONS <br />THESE PLANS AND SPECIFICATIONS ARE PROTECTED UNDER <br />FEDERAL COPYRIGHT LAWS. © BSB DESIGN MAINTAINS <br />OWNERSHIP OF SUCH AND ALL RIGHTS AND PRIVILEGES. <br />A085 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />T <br />I <br />A <br />L <br />21 <br />5 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />S <br />T <br />. <br /> <br />& <br /> <br />2 <br />1 <br />6 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />CBC 11A DIV. IV DWELLING <br />UNIT FEATURES <br />JOB NO: MR230056 <br />DWELLING UNIT FEATURES <br />1. AN ACCESSIBLE ROUTE SHALL BE PROVIDED THROUGH ALL ROOMS AND SPACES OF <br />THE DWELLING UNIT. THE ACCESSIBLE ROUTE SHALL PASS THROUGH THE PRIMARY <br />ENTRY DOOR, AND SHALL CONNECT WITH ALL ADDITIONAL PURPOSE OF THIS SECTION, <br />"ACCESSIBLE ROUTES" MAY INCLUDE HALLWAYS, CORRIDORS, AND RAMPS. 1130A.1 <br />EXCEPTION: AN ACCESSIBLE ROUTE IS NOT REQUIRED FROM THE INTERIOR OF THE <br />UNIT INTO A BASEMENT OR GARAGE, EXCEPT AS PROVIDED IN SECTION 1105A.1. <br />THE ACCESSIBLE ROUTE INTO AND THROUGHOUT COVERED MULTIFAMILY DWELLING <br />UNITS SHALL BE AT LEAST 36 INCHES WIDE. 1130A.2 <br />CHANGES IN LEVEL ON ACCESSIBLE ROUTES <br />1. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2 <br />INCH. WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO <br />GREATER THAN 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL (50-PERCENT SLOPE). <br />CHANGES IN LEVEL NOT EXCEEDING 1/4 INCH MAY BE VERTICAL. 1131A.1 <br /> <br />2. CHANGES IN LEVEL GREATER THAN 1/2 INCH SHALL BE MADE BY MEANS OF A RAMP, <br />ELEVATOR OR PLATFORM (WHEELCHAIR) LIFT. SEE SECTION 1122A FOR RAMPS AND <br />SECTION 1124A.11 FOR PLATFORM (WHEELCHAIR) LIFTS. 1131A.2 <br />DOORS <br />1. THE WIDTH AND HEIGHT OF PRIMARY ENTRY DOORS AND ALL REQUIRED EXIT DOORS <br />SHALL COMPLY WITH SECTION 1126A.1. THE REQUIREMENTS OF SECTIONS 1126A.3 <br />SHALL APPLY TO MANEUVERING CLEARANCES AT THE SIDE OF THE DOOR EXPOSED <br />TO COMMON OR PUBLIC USE SPACES (E.G., ENTRY OR EXIT DOORS WHICH OPEN <br />FROM THE COVERED MULTIFAMILY DWELLING UNIT INTO A CORRIDOR, HALLWAY OR <br />LOBBY, OR DIRECTLY TO THE OUTSIDE). 1132A.1 <br />2. EXCEPT AS ALLOWED BY SECTION 1109A.2, INTERIOR DOORS INTENDED FOR USER <br />PASSAGE AND SECONDARY EXTERIOR DOORS SHALL COMPLY WITH THIS SECTION. <br />THE PROVISIONS OF THIS SECTION SHALL APPLY TO THE DWELLING UNIT SIDE OF <br />DOORS LEADING FROM THE INTERIOR OF THE DWELLING UNIT TO AN UNFINISHED <br />BASEMENT OR AN ATTACHED GARAGE. 1132A.2 <br />3. DOORS SHALL COMPLY WITH THE FOLLOWING: 1132A.3 <br />a. DOORS SHALL NOT BE LESS THAN 6 FEET 8 INCHES IN HEIGHT. <br />b. SWINGING DOORS SHALL PROVIDE A NET CLEAR OPENING WIDTH OF NOT LESS <br />THAN 32 INCHES,MEASURED WITH THE DOOR OR DOORS POSITIONED AT AN <br />ANGLE OF 90 DEGREES FROM THE CLOSED POSITION. A 34-INCH DOOR IS <br />ACCEPTABLE. THE PRIMARY ENTRY DOOR AND ALL REQUIRED EXIT DOORS <br />SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 1126A.1. <br />c. SWINGING DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES. <br />d. A NOMINAL 32-INCH CLEAR OPENING PROVIDED BY A STANDARD 6-FOOT WIDE <br />SLIDING PATIO DOOR ASSEMBLY IS ACCEPTABLE. <br />e. A PAIR OF DOORS, MANUAL OR AUTOMATIC, MUST HAVE AT LEAST ONE LEAF <br />WHICH PROVIDES A CLEAR WIDTH OF NOT LESS THAN 32 INCHES, MEASURED <br />WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED <br />POSITION. <br />f. THE WIDTH OF ANY COMPONENT IN THE MEANS OF EGRESS SYSTEM SHALL <br />NOT BE LESS THAN THE MINIMUM WIDTH REQUIRED BY 1005. <br />4.THE FLOOR OR LANDING ON EACH SIDE OF A DOOR SHALL BE LEVEL. PRIMARY ENTRY <br />DOORS, REQUIRED EXIT DOORS OR SECONDARY EXTERIOR DOORS WITH CHANGES <br />IN HEIGHT BETWEEN THE INTERIOR SURFACE OR FLOOR LEVEL AND THE EXTERIOR <br />SURFACE OR FLOOR LEVEL SHALL COMPLY WITH THE FOLLOWING: 1132A.4 <br />a. EXTERIOR LANDINGS OF IMPERVIOUS CONSTRUCTION (E.G., CONCRETE, BRICK, <br />FLAGSTONE) SERVING PRIMARY ENTRY DOORS AND REQUIRED EXIT DOORS <br />ARE LIMITED TO NOT MORE THAN ½ INCH OF CHANGE IN HEIGHT BETWEEN <br />FLOOR SURFACES. CHANGES IN LEVEL SHALL COMPLY WITH SECTION 1131A. <br />b. EXTERIOR LANDINGS OF PERVIOUS CONSTRUCTION (E.G., WOOD DECKING WITH <br />SPACES) SHALL BE THE SAME LEVEL AS THE INTERIOR LANDING, EXCEPT THAT <br />SECONDARY EXTERIOR DOORS MAY HAVE NO MORE THAN 1/2 INCH OF CHANGE <br />IN HEIGHT BETWEEN FLOOR SURFACES. CHANGES IN LEVEL SHALL COMPLY <br />WITH SECTION 1131A. <br />c. SECONDARY EXTERIOR DOORS ONTO DECKS, PATIOS OR BALCONY SURFACES <br />CONSTRUCTED OF IMPERVIOUS MATERIALS (E.G., CONCRETE, BRICK, <br />FLAGSTONE) MAY HAVE A MAXIMUM CHANGE IN HEIGHT FROM THE INTERIOR <br />LANDING OF 4 INCHES. CHANGES IN HEIGHT GREATER THAN 1/2 INCH SHALL BE <br />ACCOMPLISHED BY MEANS OF A RAMP COMPLYING WITH SECTION 1114A OR BY <br />MEANS OF A PLATFORM CONSTRUCTED TO THE LEVEL OF THE FLOOR AS <br />ILLUSTRATED IN (FIGURE 11A-8J). <br />d. SECONDARY EXTERIOR DOORS ONTO DECKS, PATIOS OR BALCONY SURFACES <br />CONSTRUCTED OF IMPERVIOUS MATERIALS (E.G., CONCRETE, BRICK, <br />FLAGSTONE) MAY HAVE A MAXIMUM CHANGE IN HEIGHT FROM THE INTERIOR <br />LANDING OF 1 INCH, PROVIDED A RAMP WITH A MAXIMUM SLOPE OF 1:8 IS <br />PERMANENTLY INSTALLED. (SEE FIGURE 11A-8K). <br /> FIGURE 11A-8K <br />e. IN BUILDINGS CONTAINING COVERED MULTIFAMILY DWELLING UNITS, THE <br />FLOOR OR LANDING IMMEDIATELY OUTSIDE THE ENTRY MAY BE SLOPED UP TO <br />1/4 INCH PER FOOT (12 INCHES), IN A DIRECTION AWAY FROM THE PRIMARY <br />ENTRANCE OF THE DWELLING UNIT FOR DRAINAGE. <br />5. THRESHOLDS AT THE PRIMARY ENTRY AND REQUIRED EXIT DOORS SHALL BE NO <br />HIGHER THAN 1/2". THRESHOLDS AT SECONDARY EXTERIOR DOORS, INCLUDING <br />SLIDING DOOR TRACKS, SHALL BE NO HIGHER THAN 3/4". CHANGES IN HEIGHT AT <br />INTERIOR DOOR THRESHOLDS (E.G., FLOOR MATERIAL CHANGES AT DOOR <br />THRESHOLDS) SHALL NOT EXCEED 1/2". THRESHOLDS SHALL COMPLY WITH THE <br />FOLLOWING: 1132A.4.1 <br />a. THRESHOLDS WITH A CHANGE IN HEIGHT OF NOT MORE THAN 1/4" MAY BE <br />VERTICAL. <br />b. THRESHOLDS WITH A CHANGE IN HEIGHT BETWEEN 1/4 INCH AND 3/4" SHALL BE <br />BEVELED WITH A SLOPE NO GREATER THAN 1 UNIT VERTICAL IN 2 UNITS <br />HORIZONTAL (50-PERCENT SLOPE). <br />6. MANEUVERING CLEARANCES AT INTERIOR DOORS SHALL PROVIDE A MINIMUM <br />LENGTH ON BOTH SIDES OF THE DOOR OF AT LEAST 42 INCHES MEASURED AT A <br />RIGHT ANGLE TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION. 1132A.5.1 <br />EXCEPTIONS: <br />a. A 39-INCH LENGTH IS ACCEPTABLE WHEN A MINIMUM CLEAR OPENING WIDTH OF <br />34 INCHES IS PROVIDED. <br />b. THE FLOOR OR LANDING ON THE DWELLING UNIT SIDE OF THE PRIMARY ENTRY <br />DOOR AND ANY REQUIRED EXIT DOOR SHALL HAVE A MINIMUM LENGTH OF NOT <br />LESS THAN 44 INCHES. SECTION 1126A.3 SHALL APPLY TO MANEUVERING <br />CLEARANCES AT THE SIDE OF THE DOOR EXPOSED TO COMMON OR PUBLIC <br />USE SPACES. <br />KITCHENS <br />KITCHENS WITHIN ADAPTABLE DWELLING UNITS SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL COMPLY <br />WITH THIS SECTION. (SEE FIGURE 11A-10A). 1133A.1 <br />1. CLEAR FLOOR SPACE AT KITCHENS SHALL COMPLY WITH THE FOLLOWING: 1133A.2 <br />a. A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES THAT ALLOWS A PARALLEL <br />APPROACH BY A PERSON IN A WHEELCHAIR SHALL BE PROVIDED AT THE RANGE OR <br />COOKTOP. <br />b. A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES THAT ALLOWS EITHER A PARALLEL <br />OR FORWARD APPROACH SHALL BE PROVIDED AT THE KITCHEN SINK AND ALL OTHER <br />FIXTURES OR APPLIANCES INCLUDING THE OVEN, DISHWASHER, REFRIGERATOR/FREEZER <br />AND TRASH COMPACTOR <br />c. A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES THAT ALLOWS EITHER A PARALLEL <br />OR A FORWARD APPROACH SHALL BE PROVIDED AT THE WORK SURFACE REQUIRED BY <br />SECTION 1133A.4. <br />d. THE CENTERLINE OF THE 30 INCH BY 48 INCH CLEAR FLOOR SPACE PROVIDED FOR PARALLEL <br />OR FORWARD APPROACH SHALL BE ALIGNED WITH THE CENTERLINE OF THE WORK SURFACE, <br />APPLIANCE OR FIXTURE. <br />BATHING & TOILET FACILITIES <br />1. ONLY ONE BATHROOM NEED TO BE ACCESSIBLE PROVIDED IT COMPLIES WITH THE <br />FOLLOWING ADDITIONAL REQUIREMENTS AND ALL OTHER BATHROOMS INCLUDING POWDER <br />ROOMS WITHIN THE UNIT ARE ON ACCESSIBLE ROUTE WITH USABLE ENTRY DOORS. <br />1134A.2 OPTION 2 <br />A. WHEN BOTH TUB AND SHOWER FIXTURES ARE PROVIDED, AT LEAST ONE SHALL BE <br />MADE ACCESSIBLE. WHEN TWO OR MORE LAVATORIES IN A BATHROOM ARE <br />PROVIDED, AT LEAST ONE SHALL BE MADE ACCESSIBLE. 1134A.2 OPTION 2.6 <br />B. TOILETS SHALL BE LOCATED IN A MANNER THAT PERMIT A GRAB BAR TO BE INSTALLED <br />ON ONE SIDE OF THE FIXTURE. IN LOCATIONS WHERE TOILETS ARE ADJACENT TO <br />WALLS OR BATH-TUBS, THE CENTERLINE OF THE FIXTURE MUST BE A MINIMUM OF 1'-6" <br />FROM THE OBSTACLE. THE OTHER (NON-GRAB BAR) SIDE OF THE TOILET FIXTURE <br />MUST BE A MINIMUM OF 1'-6" FROM THE FINISHED SURFACE OF ADJOINING WALLS, <br />VANITIES OR FROM THE EDGE OF THE LAVATORY. 1134A.7.1 <br />C. VANITIES AND LAVATORIES SHALL BE INSTALLED WITH THE CENTERLINE OF THE <br />FIXTURE A MINIMUM OF 1'-6" HORIZONTALLY FROM AN ADJOINING WALL OR FIXTURE. <br />THE TOP OF THE FIXTURE RIM SHALL BE A MAXIMUM OF 2'-10" ABOVE THE FINISHED <br />FLOOR. <br />2. ALL POWDER ROOMS SHALL BE DESIGNED TO COMPLY WITH SECTION 1134A.2, OPTION 2, <br />ITEMS 8 THROUGH 12. WHEN THE POWDER ROOM IS THE ONLY TOILET FACILITY LOCATED ON <br />AN ACCESSIBLE LEVEL, IT SHALL COMPLY WITH THE OPTION 2 ITEMS LISTED ABOVE, PLUS <br />ALL ADDITIONAL REQUIREMENTS LOCATED IN SECTIONS 1134A.4,1134A.7 AND 1134A.8. <br />1134A.3 <br />3. BATHING AND TOILET FACILITIES REQUIRED TO BE ADAPTABLE SHALL PROVIDE SUFFICIENT <br />MANEUVERING SPACE FOR A PERSON USING A WHEELCHAIR OR OTHER MOBILITY AID TO <br />ENTER AND CLOSE THE DOOR, USE THE FIXTURES, REOPEN THE DOOR AND EXIT. <br />WHERE THE DOOR SWINGS INTO THE BATHROOM OR POWDER ROOM, THERE SHALL BE A <br />CLEAR MANEUVERING SPACE OUTSIDE THE SWING OF THE DOOR OF AT LEAST 30 INCHES BY <br />48 INCHES WITHIN THE ROOM. THE CLEAR MANEUVERING SPACE SHALL ALLOW THE USER TO <br />POSITION A WHEELCHAIR OR OTHER MOBILITY AID CLEAR OF THE PATH OF THE DOOR AS IT <br />IS CLOSED AND TO PERMIT USE OF FIXTURES. <br />DOORS MAY SWING INTO THE REQUIRED CLEAR SPACE AT ANY FIXTURE WHEN A CLEAR <br />MANEUVERING SPACE IS PROVIDED OUTSIDE THE SWING ARC OF THE DOOR SO IT CAN BE <br />CLOSED. <br />MANEUVERING SPACES MAY INCLUDE ANY KNEE SPACE OR TOE SPACE AVAILABLE BELOW <br />BATHROOM FIXTURES. 1134A.4 <br />4. BATHTUBS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH THE FOLLOWING: 1134A.5 <br />A. THERE SHALL BE A MINIMUM CLEAR FLOOR SPACE 48 INCHES PARALLEL BY 30 INCHES <br />PERPENDICULAR TO THE SIDE OF A BATHTUB OR BATHTUB-SHOWER COMBINATION <br />(MEASURED FROM THE FOOT OR DRAIN END OF THE BATHTUB) TO PROVIDE FOR THE <br />MANEUVERING OF A WHEELCHAIR AND TRANSFER TO AND FROM THE BATHING <br />FACILITIES. THE AREA UNDER A LAVATORY MAY BE INCLUDED IN THE CLEAR FLOOR <br />SPACE PROVIDED THE KNEE AND TOE SPACE COMPLY WITH SECTION 1134A.8. <br />CABINETS UNDER LAVATORIES AND TOILETS SHALL NOT ENCROACH INTO THE CLEAR <br />FLOOR SPACE. <br />B. A BATHTUB INSTALLED WITHOUT SURROUNDING WALLS SHALL PROVIDE REINFORCED <br />AREAS FOR THE INSTALLATION OF FLOOR-MOUNTED GRAB BARS. <br />WHERE A BATHTUB IS INSTALLED WITH SURROUNDING WALLS, GRAB BAR <br />REINFORCEMENT SHALL BE LOCATED ON EACH END OF THE BATHTUB, 32 INCHES TO <br />38 INCHES ABOVE THE FLOOR, EXTENDING A MINIMUM OF 24 INCHES FROM THE FRONT <br />EDGE OF THE BATHTUB TOWARD THE BACK WALL OF THE BATHTUB. THE GRAB BAR <br />REINFORCEMENT SHALL BE A MINIMUM OF 6 INCHES NOMINAL IN HEIGHT. SEE FIGURE <br />11A-9G. <br />GRAB BAR REINFORCEMENT SHALL BE INSTALLED ON THE BACK WALL OF THE <br />BATHTUB A MAXIMUM OF 6 INCHES ABOVE THE BATHTUB RIM EXTENDING UPWARD TO <br />AT LEAST 38 INCHES ABOVE THE FLOOR. GRAB BAR BACKING SHALL BE INSTALLED <br />HORIZONTALLY TO PERMIT THE INSTALLATION OF A 48-INCH GRAB BAR WITH EACH END <br />A MAXIMUM OF 6 INCHES FROM THE END WALLS OF THE BATHTUB. THE GRAB BAR <br />REINFORCEMENT SHALL BE A MINIMUM OF 6 INCHES NOMINAL IN HEIGHT. <br />C. FAUCET CONTROLS AND OPERATION MECHANISMS SHALL BE OPERABLE WITH ONE <br />HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE <br />WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 <br />POUND-FORCE. LEVER OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED <br />MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. <br />D. A SHOWER SPRAY UNIT IS NOT REQUIRED IN BATHTUBS. <br />E. DOORS AND PANELS OF BATHTUB ENCLOSURES SHALL BE SUBSTANTIALLY <br />CONSTRUCTED FROM APPROVED, SHATTER-RESISTANT MATERIALS. HINGED DOORS <br />SHALL OPEN OUTWARD. GLAZING USED IN DOORS AND PANELS OF BATHTUB <br />ENCLOSURES SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVED <br />PLASTIC. WHEN GLASS IS USED, IT SHALL HAVE MINIMUM THICKNESS OF NOT LESS <br />THAN 1/8 INCH WHEN FULLY TEMPERED, OR 1/4 INCH WHEN LAMINATED, AND SHALL <br />PASS THE TEST REQUIREMENTS OF THIS PART, CHAPTER 24 GLASS AND GLAZING. <br />PLASTICS USED IN DOORS AND PANELS OF BATHTUB ENCLOSURES SHALL BE OF A <br />SHATTER-RESISTANT TYPE. <br />DOORS (cont.) <br />7. THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL <br />EXTEND 18 INCHES PAST THE STRIKE EDGE FOR ALL DOORS. THE WIDTH OF THE <br />LEVEL AREA AT THE EXTERIOR SIDE OF THE PRIMARY ENTRY DOOR AND ANY <br />REQUIRED EXIT DOORS SHALL COMPLY WITH SECTION 1126A. <br />a. SEE SECTION 1134A FOR BATHROOMS THAT ARE REQUIRED TO BE ACCESSIBLE. <br />b. TWENTY-FOUR INCHES IS PREFERRED FOR STRIKE EDGE CLEARANCE. <br />8.MAXIMUM EFFORT TO OPERATE DOOR SHALL NOT EXCEED 8 1/2 POUNDS (38 N) FOR <br />EXTERIOR DOORS AND 5 POUNDS (22 N) FOR INTERIOR DOORS, SUCH PULL OR PUSH <br />EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER <br />PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC <br />DOOR OPERATORS MAY BE UTILIZED TO MEET THESE STANDARDS. WHEN FIRE <br />DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE <br />INCREASED TO THE MINIMUM ALLOWABLE BY THE APPROPRIATE ENFORCEMENT <br />AGENCY, NOT TO EXCEED 15 POUNDS (66.7 N). 1132A.6 <br />9.THE TYPE OF LATCH AND LOCK REQUIRED FOR ALL DOORS SHALL BE IN <br />ACCORDANCE WITH SECTION 1132A.8 AND CHAPTER 10, SECTION 1010. 1132A.7 <br />10. HAND-ACTIVATED DOOR LATCHING, LOCKING AND OPENING HARDWARE SHALL BE <br />CENTERED BETWEEN 30 INCHES AND 44 INCHES ABOVE THE FLOOR. LATCHING AND <br />LOCKING DOORS THAT ARE HAND-ACTIVATED AND ON AN ACCESSIBLE ROUTE SHALL <br />BE OPERABLE WITH A SINGLE EFFORT BY LEVER-TYPE HARDWARE, PANIC BARS, <br />PUSH-PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE <br />PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. <br />LOCKED EXIT DOORS SHALL OPERATE CONSISTENT WITH SECTION 1132A.6,IN THE <br />DIRECTION OF EGRESS. <br />11. THE LEVER OR LEVER OF ACTUATED LATCHES OR LOCKS SHALL BE CURVED WITH A <br />RETURN TO WITHIN 1/2" OF THE DOOR TO PREVENT CATCHING ON THE CLOTHING <br />OF PERSONS DURING EGRESS IN GROUP R AND U OCCUPANCIES OF AN OCCUPANT <br />LOAD GREATER THAN 10. 1132A.8.1 <br />12. THE BOTTOM 10" OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A <br />SMOOTH, UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A <br />WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS <br />CONDITION. WHERE NARROW FRAME DOORS ARE USED, A 10" HIGH SMOOTH PANEL <br />SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR, WHICH WILL ALLOW THE <br />DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR <br />HAZARDOUS CONDITION. 1132A.9 <br />EXCEPTION: AUTOMATIC AND SLIDING DOORS. <br />13.EVERY PRIMARY ENTRANCE TO A COVERED MULTIFAMILY DWELLING UNIT SHALL BE <br />PROVIDED WITH A DOOR BUZZER, BELL, CHIME OR EQUIVALENT. THE ACTIVATING <br />MECHANISM SHALL BE MOUNTED A MAXIMUM OF 48 INCHES ABOVE THE FLOOR AND <br />CONNECTED TO PERMANENT WIRING. 1132A.10 <br />KITCHENS (cont.) <br />2. KITCHENS SHALL HAVE A MINIMUM CLEAR WIDTH MEASURED BETWEEN ANY CABINET, <br />COUNTERTOP, OR THE FACE OF ANY APPLIANCE (EXCLUDING HANDLES AND <br />CONTROLS) THAT PROJECTS INTO THE KITCHEN AND THE OPPOSING CABINET, <br />COUNTERTOP, APPLIANCE, OR WALL AS FOLLOWS: 1133A.2.1 <br />a. U-SHAPED KITCHENS, DESIGNED WITH PARALLEL APPROACH AT A RANGE OR <br />COOKTOP LOCATED AT THE BASE OF THE U, SHALL HAVE A MINIMUM CLEAR <br />WIDTH OF AT LEAST 60 INCHES. (SEE FIGURE 11A-10A). <br />b. U-SHAPED KITCHENS, DESIGNED WITH A COOKTOP OR SINK LOCATED AT THE <br />BASE OF THE U, WHICH PROVIDES KNEE AND TOE SPACE IN ACCORDANCE WITH <br />SECTION 1133A.7 TO ALLOW FOR A FORWARD APPROACH, SHALL HAVE A CLEAR <br />WIDTH OF AT LEAST 48 INCHES. (SEE FIGURE 11A-10A). <br />c. ALL OTHER KITCHEN DESIGNS SHALL PROVIDE A MINIMUM CLEAR WIDTH OF AT <br />LEAST 48 INCHES. (SEE FIGURE 11A-10A). <br />3.BASE CABINETS DIRECTLY UNDER THE KITCHEN SINK COUNTER AREA, INCLUDING <br />TOEBOARD AND SHELVING, SHALL BE REMOVABLE WITHOUT THE USE OF <br />SPECIALIZED TOOLS OR SPECIALIZED KNOWLEDGE IN ORDER TO PROVIDE KNEE <br />AND TOE SPACE FOR A WHEELCHAIR. THE FINISH FLOOR BENEATH THE KITCHEN SINK <br />COUNTER AREA SHALL BE EXTENDED TO THE WALL. 1133A.3 <br />4.KITCHEN COUNTERTOPS SHALL BE PROVIDED WITH THE FOLLOWING: 1133A.4. <br />a. A MINIMUM LINEAR LENGTH OF 30 INCHES OF COUNTERTOP SHALL BE <br />PROVIDED FOR THE KITCHEN SINK INSTALLATION. <br />b. A MINIMUM LINEAR LENGTH OF 30 INCHES OF COUNTERTOP SHALL BE <br />PROVIDED FOR A WORK SURFACE. THE SINK AND WORK SURFACE MAY BE A <br />SINGLE INTEGRAL UNIT A MINIMUM OF 60 INCHES IN LENGTH, OR BE SEPARATE <br />COMPONENTS. <br />EXCEPTION: TWO 15-INCH MINIMUM WIDTH BREADBOARDS MAY BE PROVIDED IN LIEU <br />OF THE REQUIRED 30 INCHES OF COUNTERTOP WORK SURFACE. <br />5.REPOSITIONABLE COUNTERTOPS SHALL BE PROVIDED IN A MINIMUM OF FIVE <br />PERCENT OF THE COVERED MULTIFAMILY DWELLING UNITS. REPOSITIONABLE <br />COUNTERTOPS SHALL COMPLY WITH THE FOLLOWING: 1133A.4.1 <br />a. SINKS AND WORK SURFACE SPACE REQUIRED BY SECTION 1133A.4 SHALL BE <br />DESIGNED TO ENABLE REPOSITIONING TO A MINIMUM HEIGHT OF 28 INCHES. <br />b. BASE CABINETS DIRECTLY UNDER THE KITCHEN SINK COUNTER AREA AND <br />WORK SURFACE SHALL BE REMOVABLE AS REQUIRED IN SECTION 1133A.3. <br />c. THE SIDES OF ADJACENT CABINETS AND THE BACK WALL, WHICH MAY BECOME <br />EXPOSED TO MOISTURE OR FOOD HANDLING WHEN A COUNTERTOP IS <br />LOWERED, SHALL BE CONSTRUCTED OF DURABLE, NONABSORBENT MATERIALS <br />APPROPRIATE FOR SUCH USES. <br />d. FINISHED FLOORING SHALL BE EXTENDED TO THE WALL BENEATH THE SINK <br />AND WORK SURFACE. <br />EXCEPTIONS: <br />1. STONE, CULTURED STONE AND TILED COUNTERTOPS MAY BE USED <br />WITHOUT MEETING THE REPOSITIONING REQUIREMENTS. <br />2. TWO 15-INCH MINIMUM WIDTH BREADBOARDS MAY BE PROVIDED IN LIEU <br />OF THE REQUIRED 30 INCHES OF COUNTERTOP WORK SURFACE. <br />6.LOWER SHELVING AND/OR DRAWER SPACE SHALL BE PROVIDED IN THE KITCHEN AT A <br />HEIGHT OF NO MORE THAN 48 INCHES ABOVE THE FLOOR. 1133A.5 <br />7.FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE <br />HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE <br />WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN <br />5 POUND FORCE. LEVER-OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED <br />MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING VALVES ARE <br />ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. 1133A.6 <br />8.KNEE AND TOE SPACE, WHEN REQUIRED BY SECTION 1133A, SHALL COMPLY WITH <br />THE FOLLOWING: 1133A.7. <br />a. THE KNEE AND TOE SPACE SHALL BE CLEAR AND UNOBSTRUCTED, OR <br />REMOVABLE BASE CABINETS IN COMPLIANCE WITH SECTION 1133A.3 SHALL BE <br />PROVIDED. <br />b. THE KNEE AND TOE SPACE SHALL BE 30 INCHES WIDE MINIMUM, CENTERED ON <br />THE SINK, COUNTERTOP OR APPLIANCE. <br />c. THE KNEE SPACE SHALL BE AT LEAST 27 INCHES ABOVE THE FINISH FLOOR. <br />d. THE KNEE SPACE SHALL BE 11 INCHES DEEP MINIMUM AT 9 INCHES ABOVE THE <br />FINISH FLOOR, AND 8 INCHES DEEP MINIMUM AT 27 INCHES ABOVE THE FINISH <br />FLOOR, MEASURED FROM THE FRONT EDGE. <br />e. THE TOE SPACE SHALL BE AT LEAST 9 INCHES ABOVE THE FINISH FLOOR. <br />f. A CLEAR FLOOR SPACE SHALL NOT EXTEND INTO THE KNEE AND TOE SPACE <br />MORE THAN 19 INCHES. <br />9.WATER SUPPLY AND DRAIN PIPES UNDER KITCHEN SINKS SHALL BE INSULATED OR <br />OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER <br />KITCHEN SINKS. 1133A.7.1. <br />BATHING & TOILET FACILITIES (cont.) <br />5. SHOWERS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH THE FOLLOWING: 1134A.6 <br />A. WHEN ONE OR MORE SHOWER STALLS ARE PROVIDED WITHIN THE SAME DWELLING UNITS, <br />AT LEAST ONE SHOWER STALL SHALL COMPLY WITH ONE OF THE FOLLOWING <br />REQUIREMENTS: <br />1. THE SHOWER STALL SHALL MEASURE AT LEAST 42 INCHES WIDE BY 48 INCHES DEEP <br />WITH AN ENTRANCE OPENING OF AT LEAST 36 INCHES; OR <br />2. THE SHOWER STALL SHALL MEASURE AT LEAST 30 INCHES DEEP BY 60 INCHES WIDE <br />WITH AN ENTRANCE OPENING OF AT LEAST 60 INCHES. A WATER CLOSET MAY <br />PROJECT A MAXIMUM OF 12 INCHES INTO THE OPENING, PROVIDED THAT A MINIMUM <br />OF 36 INCHES CLEAR SPACE IS MAINTAINED BETWEEN THE WATER CLOSET AND THE <br />SHOWER WALL AS ILLUSTRATED IN FIGURE 11A-9L: OR <br />3. OTHER SHOWER STALL CONFIGURATIONS SHALL MEASURE AT LEAST 36 INCHES DEEP <br />BY 60 INCHES WIDE WITH AN ENTRANCE OPENING OF AT LEAST 36 INCHES WHEN A <br />WALL IS INSTALLED ON THE OPENING SIDE. <br />B. THE MAXIMUM SLOPE OF THE SHOWER FLOOR SHALL BE 1/2 INCH PER FOOT IN ANY <br />DIRECTION AND SHALL SLOPE TO A DRAIN. THE FLOOR SURFACES SHALL BE OF <br />CARBORUNDUM OR GRIT-FACED TILE OR OF MATERIAL PROVIDING EQUIVALENT SLIP <br />RESISTANCE. <br />C. A CLEAR MANEUVERING SPACE AT LEAST 30 INCHES IN WIDTH BY 48 INCHES IN LENGTH <br />SHALL BE LOCATED OUTSIDE THE SHOWER, FLUSH AND PARALLEL TO THE CONTROL WALL. <br />D. GRAB BAR REINFORCEMENT SHALL BE INSTALLED CONTINUOUS IN THE WALLS OF <br />SHOWERS 32 INCHES TO 38 INCHES ABOVE THE FLOOR. THE GRAB BAR REINFORCEMENT <br />SHALL BE A MINIMUM OF 6 INCHES NOMINAL IN HEIGHT. GLASS-WALLED SHOWER STALLS <br />SHALL PROVIDE REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED OR CEILING- <br />MOUNTED GRAB BARS. <br />E. WHEN A THRESHOLD IS USED, IT SHALL BE A MAXIMUM OF 2 INCHES IN HEIGHT AND HAVE A <br />BEVELED OR SLOPED ANGLE NOT EXCEEDING 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL (26.6 <br />DEGREES FROM THE HORIZONTAL). THRESHOLDS 1/2 INCH OR LESS IN HEIGHT MAY HAVE A <br />BEVELED OR SLOPED ANGLE NOT EXCEEDING 1 UNIT VERTICAL IN 1 UNIT HORIZONTAL (45 <br />DEGREES FROM HORIZONTAL). <br />F. FAUCET CONTROLS AND OPERATION MECHANISMS SHALL BE OPERABLE WITH ONE HAND <br />AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE <br />FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUND-FORCE. <br />LEVER OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE <br />EXAMPLES OF ACCEPTABLE DESIGNS. <br />G. DOORS AND PANELS OF SHOWER ENCLOSURES SHALL BE SUBSTANTIALLY CONSTRUCTED <br />FROM APPROVED, SHATTER-RESISTANT MATERIALS. HINGED SHOWER DOORS SHALL OPEN <br />OUTWARD. GLAZING USED IN DOORS AND PANELS OF SHOWER ENCLOSURES SHALL BE <br />FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC. WHEN GLASS IS <br />USED, IT SHALL HAVE MINIMUM THICKNESS OF NOT LESS THAN 1/8 INCH WHEN FULLY <br />TEMPERED, OR 1/4 INCH WHEN LAMINATED, AND SHALL PASS THE TEST REQUIREMENTS OF <br />THIS PART, CHAPTER 24 GLASS AND GLAZING. PLASTICS USED IN DOORS AND PANELS OF <br />SHOWERS ENCLOSURES SHALL BE OF A SHATTER-RESISTANT TYPE. <br />6.WATER CLOSETS IN BATHROOMS OR POWDER ROOMS REQUIRED TO BE ACCESSIBLE SHALL <br />COMPLY WITH THE FOLLOWING: 1134A.7 <br />A. THE MINIMUM FLOOR SPACE PROVIDED AT A WATER CLOSET SHALL BE 48 INCHES IN CLEAR <br />WIDTH. THE CLEAR FLOOR SPACE SHALL EXTEND PAST THE FRONT EDGE OF THE WATER <br />CLOSET AT LEAST 36 INCHES. SEE FIGURE 11A-9M. <br />EXCEPTION: THE 48 INCHES MINIMUM CLEAR WIDTH MAY BE REDUCED TO 36 INCHES FOR <br />LAVATORIES, CABINETS, WING WALLS OR PRIVACY WALLS LOCATED IMMEDIATELY ADJACENT <br />TO A WATER CLOSET WHICH EXTEND NO MORE THAN 24 INCHES IN DEPTH. <br />C <br />C 07/08/2025 PC COMMENTS RESPONSE <br />#3 <br />1131A.1 - Change in Level1 <br />1132A.4.3 - Secondary Exterior Door <br />1132A.4.4 - ramp at secondary ext. door <br />1133A.2.3 - Clear floor space <br />cabinet sections, typ. <br />1133A.3 - Removable base cabinets <br />1133A.7.1 - Knee and toe space <br />1132A5.1 - Maneauvering clearance at dwelling unit doors <br />1134A.6 - Shower sizes <br />1134A.5.2 - Reinforcement for Grab Bars <br />1134A.7.1 - Wing Wall / Cabinet at Water Closet <br />1132A.8 - Floor Level Change up to 1/2" at Threshold <br />1132A.9 - Typical Location of Door and Gate Elements