Laserfiche WebLink
DOOR TYPES NOTE: "T" INDICATES TEMPERED GLAZING. ALL GLAZING IN DOORS SHALL BE TEMPERED. <br />A B C D <br />DOOR HEIGHT <br />WIDTH <br />DOOR <br />DOOR HEIGHT <br />WIDTH <br />DOOR <br />DOOR HEIGHT <br />DOOR WIDTH <br />E <br />DOOR HEIGHT <br />DOOR WIDTH <br />T T <br />DOOR WIDTH <br />DOOR HEIGHT <br />TYP. <br />10" <br />FINISH FLOOR <br />LOUVER PER MECH'L <br />DWGS.F <br />DOOR HEIGHT <br />WIDTH <br />DOOR <br />T <br />10" <br />DOOR AND WINDOW NOTES <br />1. ONE EXIT DOOR NOT LESS THAN 3' WIDE AND 6'-8" IN HEIGHT AND CAPABLE OF OPENING 90 DEGREES WITH A CLEAR SPACE OF AT LEAST 32" IS <br />REQUIRED. CBC 1010.1.1 <br />2. MANUFACTURED DOORS AND WINDOWS SHALL BE CERTIFIED AND LABELED IN COMPLIANCE WITH THE APPROPRIATE INFILTRATION STANDARDS. <br />3. EGRESS DOORS SHALL BE READILY OPEN FROM THE EGRESS SIDE WITHOUT THE USE OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. CBC <br />10010.1.9. <br />4. ALL SWING DOOR HANDLES SHALL BE LEVER TYPE THROUGHOUT UNLESS OTHERWISE NOTED AND SHALL CURVE AND RETURN TO WITHIN 1/2" OF <br />THE DOOR. <br />5. ALL EXTERIOR STOREFRONT SYSTEM TO BE INTEGRAL LIGHT BRONZE TINT. INCLUDE ANTI-GRAFFITI SHIELDS ON GROUND LEVEL GLAZING <br />6. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT. FLUSH BOLTS OR SURFACE <br />BOLTS ARE PROHIBITED. APPLIES TO ALSO EXIT GATES. THE UNLATCHING OF ANY LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. CBC <br />1010.1.9 <br />7. POST A SIGN ADJACENT TO THE REQUIRED MAIN EXIT DOOR WITH 1" LETTERING STATING "THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS <br />HOURS." MAIN EXIT ONLY. CBC 1010.1.9.3 <br />8. FIELD VERIFY ALL ROUGH OPENINGS FOR STOREFRONT SYSTEMS BEFORE ORDERING. <br />9. VIEW PORT IN FIRE CORRIDOR DOORS MAY BE INSTALLED PROVIDED THE HOLE IS NOT LARGER THAN 1 INCH IN DIAMETER THROUGH THE DOOR, <br />HAVE AT LEAST A 1/4-INCH-THICK GLASS DISC AND THE HOLDER IS OF METAL THAT WILL NOT MELT OUT WHEN SUBJECT TO TEMPERATURE OF 1,700 <br />°F. CBC 716.5.3. ITEM 1 <br />10. ALL EXTERIOR AND INTERIOR GLAZED DOORS TO BE TEMPERED. <br />11. SEE MECHANICAL FOR INTERIOR NON-RATED DOORS THAT SHALL BE UNDERCUT. SEE MECHANICAL FOR SIZE OF UNDERCUT WHERE OCCURS <br />12. GLAZING CONTAINED WITHIN A FIRE RATING DOOR MUST MEET FIRE AND IMPACT CODE REQUIREMENTS. <br />13. EGRESS DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL WHERE SERVING AN OCCUPANT LOAD OF 50 OR MORE PERSONS OR A GROUP <br />H OCCUPANCY REGARDLESS OF THE OCCUPANT LOAD. CBC 1010.1.2.1 <br />14. DOOR CLOSERS & GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE <br />DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM. CBC 1126A.4.1. <br />15. MAX. EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS, SUCH PULL OR <br />PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING <br />DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. CBC1126.4. <br />16. ANY FENESTRATION WITH "U" VALUE LOWER THAN THE DEFAULT VALUE MUST HAVE PERMANENT LABEL. OTHER FENESTRATIONS MAY HAVE A <br />FACTORY REMOVABLE LABEL. <br />17. IF REQUIRED, ONE OPENABLE WINDOW WITH AN OPENABLE AREA OF AT LEAST 5.7 SQUARE FEET, WITH A MIN. CLEAR DIMENSION OF 20" WIDE BY 24" <br />HIGH AND A SILL HEIGHT NOT OVER 44" FROM FINISH FLOOR IS REQUIRED IN ALL SLEEPING ROOMS. CBC. 1030.2 <br />18. THE EMERGENCY ESCAPE AND RESCUE OPENING SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES MEASURED <br />FROM THE FLOOR. CBC 1030.3 <br />19. PANIC HARDWARE SHALL BE LISTED IN ACCORDANCE WITH UL 305; FIRE EXIT HARDWARE SHALL BE LISTED IN ACCORDANCE WITH UL 10C AND UL <br />305; THE ACTUATING PORTION OF THE RELEASING DEVICE SHALL EXTEND AT LEAST 1/2 OF THE DOOR LEAF WIDTH; AND THE MAXIMUM UNLATCHING <br />FORCE SHALL NOT EXCEED 15 LB. (67N). CBC 1010.1.10.1 <br />20. THE MINIMUM WIDTH OF EACH DOOR OPENING SHALL BE SUFFICIENT FOR THE OCCUPANT LOAD THEREOF AND SHALL PROVIDE A CLEAR WIDTH OF <br />NOT LESS THAN 32 INCHES. THE HEIGHT OF DOORS SHALL NOT BE LESS THAN 80 INCHES. CBC 10010.1.1. <br />21. DOORS OPENING INTO EXIT ENCLOSURES SHALL BE PROTECTED PER CBC 716.5 <br />22. EACH PANE OF SAFETY GLAZING INSTALLED IN HAZARDOUS LOCATIONS (PER CBC 2406) SHALL BE IDENTIFIED BY A MANUFACTURERS DESIGNATION <br />SPECIFYING WHO APPLIED THE DESIGNATION, THE MANUFACTURER OR INSTALLER, AND THE SAFETY GLAZING STANDARD. <br />23. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. SEE <br />CBC 10010.1.9 FOR EXCEPTIONS. <br />24. ALL EGRESS DOOR OPERATION SHALL COMPLY WITH CBC 1010.1.9 THRI 1010.1.9.7. <br />25. DOOR HANDLES, LOCK AND OTHER OPERATING DEVICES SHALL BE INSTALLED AT A MIN. 34" AND A MAX. 44" ABOVE THE FINISHED FLOOR. <br />26. RATED DOOR ASSEMBLIES SHALL BE EQUIPPED WITH SMOKE GASKETS AND BE SELF- OR AUTOMATIC-CLOSING AND LATCHING, CBC 716.5.3 AND <br />716.5.9. <br />27. PANIC HARDWARE MUST BE PROVIDED ON ALL DOORS AND GATES ALONG THE POTENTIAL EGRESS PATHS FROM A GROUP A OCCUPANCY OR <br />ASSEMBLY AREA NOT CLASSIFIED AS AN OCCUPANCY E, I-2 OR I-2.1. CBC 1010.1.10.PANIC HARDWARE MAY BE OMITTED FROM A SINGLE DOOR SET <br />OF DOUBLE DOORS SERVING AS THE MAIN ENTRY IF A SIGN READING "THESE DOORS TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" IS <br />PLACED IN A CONSPICUOUS LOCATION NEAR THE DOOR. CBC 10010.1.9.3 AND 10010.1. <br />28. GLAZING AREAS OF WINDOWS SHALL HAVE A U-FACTOR OF 0.28 AND A SHGC OF 0.2 PER T-24 REPORT. <br />29. BUILDING COMMON DOOR AND RESIDENTIAL GLASS DOORS SHALL HAVE A U-FACTOR OF 0.28 AND A SHGC OF 0.2 PER T-24 REPORT. <br />30. VISIBLE TRANSMITTANCE FOR GLAZING AREAS OF WINDOWS AND DOORS IS NOT APPLICABLE PER T-24 REPORT. <br />31. ALL UNIT ENTRY DOORS AND BALCONY DOORS, UNLESS OTHERWISE NOTED (SEE BUILDING PLANS) SHALL HAVE A MIN. STC OF 26. <br />32. ALL UNIT WINDOWS, UNLESS OTHERWISE NOTED (SEE BUILDING PLANS) SHALL HAVE A MIN. STC OF 26. <br />33. ALL DOORS INTENDED FOR USER PASSAGE THAT ARE PROVIDED WITH A SILL/THRESHOLD SHALL COMPLY WILL CBC 1132A.4.1. SEE DETAIL: <br />34. FOR ADDITIONAL DOOR REQUIREMENTS AT ADAPTABLE UNITS SEE DOOR NOTES ON: -------------------------------------------------------------------------- <br />35. ALL EGRESS WINDOWS (ALL SLEEPING ROOMS. SEE PARTIAL ENLARGED BUILDING PLANS FOR LOCATIONS) SHALL COMPLY WITH CBC 1030. REFER <br />TO DETAIL: <br />GLAZING NOTES <br />1. GLAZING WITHIN A 24 INCH ARC OF EITHER SIDE OF A DOOR, ADJACENT TO A WALKING SURFACE (GREATER THAN 9 SQUARE FEET, LESS THAN 18 <br />INCHES FROM THE FLOOR AND GREATER THAN 36 INCHES FROM THE FLOOR), ADJACENT TO THE STAIR LANDING, IN RAILINGS, ADJACENT TO A TUB <br />OR SHOWER, OR A BARRIER FOR A SWIMMING POOL OR SPA MUST BE OF SAFETY GLAZING MATERIAL (CBC 2406 AND BANAL 24-1). SEE CBC 2406.4 <br />FOR MORE INFORMATION ON SAFETY GLAZING AT HAZARDOUS LOCATIONS. <br />DOOR OPERATIONS <br />A. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE <br />OR EFFORT. <br />B. HARDWARE. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS REQUIRED TO BE <br />ACCESSIBLE BY CHAPTER 11A OR 11B SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO <br />OPERATE. CBC 1010.1.9.1 <br />C. HARDWARE HEIGHT. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES SHALL BE INSTALLED 34 INCHES <br />(864 MM) MINIMUM AND 44 INCHES (1370 MM) MAXIMUM ABOVE THE FINISHED FLOOR. LOCKS USED ONLY FOR SECURITY <br />PURPOSES AND NOT USED FOR NORMAL OPERATION ARE PERMITTED AT ANY HEIGHT. SEE CBC 1010.1.9.2 FOR EXCEPTION. <br />D. LOCKS AND LATCHES. LOCKS AND LATCHES SHALL BE PERMITTED TO PREVENT OPERATION OF DOORS WHERE ANY OF THE <br />FOLLOWING EXIST: <br />1. PLACES OF DETENTION OR RESTRAINT. <br />2. IN BUILDINGS IN OCCUPANCY GROUP A HAVING AN OCCUPANT LOAD OF 300 OR LESS, GROUPS B, F, M AND S, AND IN PLACES <br />OF RELIGIOUS WORSHIP, THE MAIN DOOR OF DOORS ARE PERMITTED TO BE EQUIPPED WITH KEY-OPERATED LOCKING <br />DEVICES FROM THE EGRESS SIDE PROVIDED: <br />2.1. THE LOCKING DEVICE IS READILY DISTINGUISHABLE AS LOCKED; <br />2.2. A READILY VISIBLE DURABLE SIGN IS POSTED ON THE EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING: <br />THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. THE SIGN SHALL BE IN LETTERS 1 INCH (25 MM) HIGH ON <br />A CONTRASTING BACKGROUND; AND <br />2.3. THE USE OF THE KEY-OPERATED LOCKING DEVICE IS REVOCABLE BY THE BUILDING OFFICIAL FOR DUE CAUSE. <br />3.WHERE EGRESS DOORS ARE USED IN PAIRS, APPROVED AUTOMATIC FLUSH BOLTS SHALL BE PERMITTED TO BE USED, <br />PROVIDED THAT THE DOOR LEAF HAVING THE AUTOMATIC FLUSH BOLTS DOES NOT HAVE A DOORKNOB OR SURFACE- <br />MOUNTED HARDWARE. <br />4.DOORS FROM INDIVIDUAL DWELLING OR SLEEPING UNITS OF GROUP R OCCUPANCIES HAVING AN OCCUPANT LOAD OF 10 OR <br />LESS ARE PERMITTED TO BE EQUIPPED WITH A NIGHT LATCH, DEAD BOLT OR SECURITY CHAIN, PROVIDED SUCH DEVICES ARE <br />OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR TOOL. <br />5. FIRE DOORS AFTER THE MINIMUM ELEVATED TEMPERATURE HAS DISABLED THE UNLATCHING MECHANISM IN <br />ACCORDANCE WITH LISTED FIRE DOOR TEST PROCEDURES. <br />E.BOLT LOCKS. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED. <br />EXCEPTIONS: <br />1. ON DOORS NOT REQUIRED FOR EGRESS IN INDIVIDUAL DWELLING UNITS OR SLEEPING UNITS. <br />2. WHERE A PAIR OF DOORS SERVES A STORAGE OF EQUIPMENT ROOM, MANUALLY OPERATED EDGE-OR SURFACE-MOUNTED <br />BOLTS ARE PERMITTED ON THE INACTIVE LEAF. <br />3. WHERE A PAIR OF DOORS SERVES AN OCCUPANT LOAD OF LESS THAN 50 PERSONS IN A GROUP B, F OR S OCCUPANCY, <br />MANUALLY OPERATED EDGE-OR SURFACE-MOUNTED BOLTS ARE PERMITTED ON THE INACTIVE LEAF. THE INACTIVE LEAF <br />SHALL CONTAIN NO DOORKNOBS, PANIC BARS OR SIMILAR OPERATING HARDWARE. <br />4. WHERE A PAIR OF DOORS SERVES A GROUP B, F OR S OCCUPANCY, MANUALLY OPERATED EDGE-OR SURFACE-MOUNTED <br />BOLTS ARE PERMITTED ON THE INACTIVE LEAF PROVIDED SUCH INACTIVE LEAF IS NOT NEEDED TO MEET EGRESS CAPACITY <br />REQUIREMENTS AND THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE <br />WITH CBC 903.3.1.1. THE INACTIVE LEAF SHALL NOT CONTAIN DOORKNOBS, PANIC BARS OR SIMILAR OPERATING HARDWARE. <br />F.UNLATCHING. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ON OPERATION. EXCEPT: <br />1. WHERE MANUALLY OPERATED BOLT LOCKS ARE PERMITTED BY CBC1010.1.9.4. <br />2. DOORS WITH AUTOMATIC FLUSH BOLTS AS PERMITTED BY CBC 1010.1.9.3, ITEM 3. <br />3. DOORS FROM INDIVIDUAL DWELLING UNITS AND SLEEPING UNITS OF GROUP R OCCUPANCIES AS PERMITTED BY CBC <br />1010.1.9.3, ITEM 4 <br />1. G.SENSOR RELEASE OF ELECTRICALLY LOCKED EGRESS DOORS. THE ELECTRIC LOCKS ON SENSOR RELEASED DOORS <br />LOCATED IN A MEANS OF EGRESS IN BUILDINGS WITH AN OCCUPANCY IN GROUP A, B, I-2, I-4, M, R-1, R-2 OR R-2-1 AND <br />ENTRANCE DOORS TO TENANT SPACES IN OCCUPANCIES IN GROUP A, B, I-2, I-4, M, R-1, R-2 OR R-2.1 ARE PERMITTED WHERE <br />INSTALLED AND OPERATED IN ACCORDANCE WITH ALL OF THE FOLLOWING CRITERIA: <br />1. THE SENSOR SHALL BE INSTALLED ON THE EGRESS SIDE, ARRANGED TO DETECT AN OCCUPANT APPROACHING THE DOORS. <br />THE DOORS SHALL BE ARRANGED TO UNLOCK BY A SIGNAL FROM OR LOSS OF POWER TO THE SENSOR. <br />2. LOSS OF POWER TO THE LOCK OR LOCKING SYSTEM SHALL AUTOMATICALLY UNLOCK THE DOORS. <br />3. THE DOORS SHALL BE ARRANGED TO UNLOCK FROM A MANUAL UNLOCKING DEVICE LOCATED 40 inches to 48 inches (1016 MM <br />TO 1219 MM) VERTICALLY ABOVE THE FLOOR AND WITHIN 5 FEET (1524 MM) OF THE SECURED DOORS. READY ACCESS SHALL <br />BE PROVIDED TO THE MANUAL UNLOCKING DEVICE AND THE DEVICE SHALL BE CLEARLY IDENTIFIED BY A SIGN THAT READS <br />"PUSH TO EXIT." WHEN OPERATED, THE MANUAL UNLOCKING DEVICE SHALL RESULT IN DIRECT INTERRUPTION OF POWER TO <br />THE LOCK-INDEPENDENT OF OTHER ELECTRONICS-AND THE DOORS SHALL REMAIN UNLOCKED FOR NOT LESS THAN 30 <br />SECONDS. <br />4. ACTIVATION OF THE BUILDING FIRE ALARM SYSTEM, WHERE PROVIDED, SHALL AUTOMATICALLY UNLOCK THE DOORS, AND <br />THE DOORS SHALL REMAIN UNLOCKED UNTIL THE FIRE ALARM SYSTEM HAS BEEN RESET. <br />5. ACTIVATION OF THE BUILDING AUTOMATIC SPRINKLER SYSTEM OR FIRE DETECTION SYSTEM, WHERE PROVIDED, SHALL <br />AUTOMATICALLY UNLOCK THE DOORS. THE DOORS SHALL REMAIN UNLOCKED UNTIL THE FIRE ALARM SYSTEM HAS BEEN <br />RESET. <br />6. THE DOOR LOCKING SYSTEM UNITS SHALL BE LISTED IN ACCORDANCE WITH UL 294. <br />H.ELECTROMAGNETICALLY LOCKED EGRESS DOORS. DOORS IN THE MEANS OF EGRESS IN BUILDINGS WITH AN OCCUPANCY IN <br />GROUP A, B, E, I-1, I-2, I-4, M, R-1 OR R-2 AND DOORS TO TENANT SPACES IN GROUP A, B, E, I-1, I-2, I-4, M, R-1 OR R-2 SHALL BE <br />PERMITTED TO BE LOCKED WITH AN ELECTROMAGNETIC LOCKING SYSTEM WHERE EQUIPPED WITH HARDWARE THAT <br />INCORPORATES A BUILT-IN SWITCH AND WHERE INSTALLED AND OPERATED IN ACCORDANCE WITH ALL OF THE FOLLOWING: <br />1. THE HARDWARE THAT IS AFFIXED TO THE DOOR LEAF HAS AN OBVIOUS METHOD OF OPERATION THAT IS READILY OPERATED <br />UNDER ALL LIGHTING CONDITIONS. <br />2. THE HARDWARE IS CAPABLE OF BEING OPERATED WITH ON HAND. <br />3. OPERATION OF THE HARDWARE DIRECTLY INTERRUPTS THE POWER TO THE ELECTROMAGNETIC LOCK AND UNLOCKS THE <br />DOOR IMMEDIATELY. <br />4. LOSS OF POWER TO THE LOCKING SYSTEM AUTOMATICALLY UNLOCKS THE DOOR. <br />5. WHERE PANIC OR FIRE EXIT HARDWARE IS REQUIRED BY CBC 1010.1.10, OPERATION OF THE PANIC OR FIRE EXIT HARDWARE <br />ALSO RELEASES THE ELECTROMAGNETIC LOCK. <br />6. THE LOCKING SYSTEM UNITS SHALL BE LISTED IN ACCORDANCE WITH UL 294. <br />A <br />/13 A852 <br />/3 A821 <br />WINDOW TYPES NOTE: ALL GLAZING IN DOORS SHALL BE TEMPERED. <br />1 2 <br />WDW HT. <br />PER SCHEDULE <br />WIDTH <br />PER SCHEDULE <br />HEIGHT <br />PER SCHEDULE <br />HEIGHT <br />PER SCHEDULE <br />WIDTH <br />NOTE: SEE WALL SECTIONS FOR WINDOW DETAIL REFERENCES <br />T.O. SHEATHING <br />(U <br />. <br />O <br />. <br />N <br />) <br />8' <br /> <br />- <br /> <br />0 <br />" <br />A 3' <br /> <br />- <br /> <br />0 <br />" <br />X O <br />@ <br />E <br />G <br />R <br />E <br />S <br />S <br /> <br />W <br />D <br />W <br />MA <br />X <br />. <br /> <br />4 <br />4 <br />" <br /> <br />A <br />. <br />F <br />. <br />F <br />A <br />X O <br />al <br />l <br /> <br />i <br />d <br />e <br />a <br />s <br />, <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />s <br /> <br />a <br />n <br />d <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />r <br />e <br />p <br />r <br />e <br />s <br />e <br />n <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />t <br />h <br />i <br />s <br /> <br />d <br />r <br />aw <br />i <br />n <br />g <br /> <br />a <br />r <br />e <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />c <br />l <br />u <br />s <br />i <br />v <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br /> <br />bs <br />b <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />, <br /> <br />i <br />n <br />c <br />. <br /> <br />an <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />i <br />n <br /> <br />w <br />h <br />o <br />l <br />e <br /> <br />o <br />r <br /> <br />i <br />n <br /> <br />p <br />a <br />r <br />t <br /> <br />w <br />i <br />t <br />ho <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br /> <br />p <br />r <br />i <br />o <br />r <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />o <br />f <br /> <br />s <br />a <br />i <br />d <br /> <br />a <br />rc <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />, <br /> <br />a <br />n <br />y <br /> <br />u <br />n <br />a <br />u <br />t <br />h <br />o <br />r <br />iz <br />e <br />d <br /> <br />r <br />e <br />u <br />s <br />e <br /> <br />o <br />f <br /> <br />t <br />h <br />e <br />s <br />e <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />o <br />t <br />h <br />e <br />r <br /> <br />t <br />h <br />a <br />n <br /> <br />f <br />o <br />r <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />j <br />e <br />c <br />t <br />a <br />n <br />d <br /> <br />l <br />o <br />c <br />a <br />t <br />i <br />o <br />n <br /> <br />s <br />h <br />o <br />w <br />n <br /> <br />i <br />s <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br />JOB NO. <br />SUBMITTAL <br />DATE <br />SHEET TITLE <br />SHEET NO. <br />CLIENT: <br />Plot Date:File: <br />REVISION <br />DATE <br />21 <br />3 <br />0 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br /> <br /># <br />2 <br />0 <br />0 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />1ST PLAN CHECK SUBMITTAL 08/20/2024 <br />970 W. 190TH ST., STE 250, TORRANCE CA 90502 <br />O: 310.217.8885 <br />BSBDESIGN.COM <br />D E S I G N <br />BSB <br />4TH P.C. SUBMITTAL <br />07/08/2025 <br />2ND PLAN CHECK SUBMITTAL 01/29/2025 <br />3RD PLAN CHECK SUBMITTAL 04/17/2025 <br />4TH PLAN CHECK SUBMITTAL 07/08/2025 <br />11/4/2025 8:52:49 PM <br />MR230056 <br />A400 <br />DOOR & WINDOW SCHEDULE <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />T <br />I <br />A <br />L <br />21 <br />5 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />S <br />T <br />. <br /> <br />& <br /> <br />2 <br />1 <br />6 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br />*WINDOW SCHEDULE <br />SYMBOL TYPE <br />Construction <br />Type WIDTH HEIGHT <br />FRAME <br />MATERIAL COLOR Detail_Sill Detail_Jamb Detail_Head WINDOW NOTES <br />A 1 SLIDER XO 5' - 0" 5' - 0" VINYL WHITE 1&2&5/A822 3&6/A822 4&7/A822 <br />B 2 SLIDER XO 3' - 0" 1' - 0" VINYL WHITE 2/A822 3/A822 4/A822 FROSTED GLASS, PROVIDE SAMPLES FOR OWNER APPROVAL <br />*DOOR SCHEDULE_UNITS <br />SYMBOL ROOM NAME TYPE WIDTH HEIGHT THICK CONSTRUCTION FACE FINISH FRAME <br />FIRE <br />RATING <br />DETAILS <br />DOOR NOTESSILL DETAIL JAMB DETAIL <br />HEAD <br />DETAIL <br />U1 UNIT ENTRY A 3' - 0" 7' - 0" 1 3/4" FIBERGLASS FLUSH <br />PANEL <br />PAINT/FACTORY <br />PRIMED, ALL SIX <br />(6) SIDES <br />BALD W/O <br />CLIPS TIMELY <br />FRAMED-PRIM <br />ED <br />20 MIN 8, 12, <br />&13/A852 <br />13 & 15/ A822 13 & 15/ <br />A822 <br />SELF-CLOSING, SELF-LATCHING, SMOKE <br />SEALS, VIEWER HOLE, DOOR BELL <br />U2 COAT CLOSET B 2' - 0" 7' - 0" 1 3/4" HOLLOW <br />CORE WOOD <br />FLUSH <br />PANEL <br />PAINT WOOD NR 9/A852 (SIM) 15/A822 (SIM) 15/A822 <br />U3 BEDROOM B 3' - 0" 6' - 8" 1 3/4" HOLLOW <br />CORE WOOD <br />FLUSH <br />PANEL <br />PAINT WOOD NR 9/A852 (SIM) 15/A822 SIM. 15/A822 <br />U4 BEDOOM CLOSET C 5' - 6" 6' - 8" 1 3/4" HOLLOW <br />CORE WOOD <br />FLUSH <br />PANEL <br />PAINT WOOD NR 17/A822 18/A822 19/A822 BI-PASS WARDROBE DOOR <br />U5 BEDROOM CLOSET C 6' - 0" 6' - 8" 1 3/4" HOLLOW <br />CORE WOOD <br />FLUSH <br />PANEL <br />PAINT WOOD NR 17/A822 18/A822 19/A822 BI-PASS WARDROBE DOOR <br />U6 UTILITY CLOSET D 5' - 0" 7' - 0" 1 3/4" HOLLOW <br />METAL <br />FLUSH <br />PANEL <br />PAINT HOLLOW <br />METAL <br />NR 4/A852 (SIM) 11/A822 11/A822 ONE LITE TO BE EQUIPPED WITH LOCK IN <br />PLACE FEATURE <br />U7 BATH B 3' - 0" 6' - 8" 1 3/4" HOLLOW <br />CORE WOOD <br />FLUSH <br />PANEL <br />PAINT WOOD NR 9/A852 (SIM) 15/A822 SIM. 15/A822 <br />*DOOR SCHEDULE_COMMON AREA <br />SYMBOL ROOM NAME TYPE WIDTH HEIGHT THICK CONSTRUCTION FINISH FRA ME <br />FIRE <br />RATING SILL DTL JAMB DTL HEAD DTL DOOR NOTES <br />100 BLDG A1 CORRIDOR E 6' - 0" 7' - 0" 1 3/4" FRENCH PAINT HM NR 4/ A852 10/ A822 9/ A822 SELF-CLOSING, -SELF-LATCHING & PANIC <br />HARDWARE <br />101 BLDG A2 CORRIDOR E 6' - 0" 7' - 0" 1 3/4" FRENCH PAINT HM NR 4/ A852 10/ A822 9/ A822 SELF-CLOSING, -SELF-LATCHING & PANIC <br />HARDWARE <br />102 COMM ROOM A 3' - 0" 7' - 0" 1 3/4" FIBERGLASS PAINT TIMELY 20 MIN 9, 10/ A852 14/ A822 14/ A822 SELF-CLOSING, SELF-LATCHING, SMOKE SEALS, <br />VIEWER HOLE, DOOR BELL <br />103 CONFERENCE ROOM F 3' - 0" 6' - 8" 1 3/4" FRENCH PAINT WOOD NR 9, 10/A852 15/A822 15/A822 SELF-CLOSING & SELF-LATCHING <br />104 RESTROOM B 3' - 0" 6' - 8" 1 3/4" WOOD PAINT WOOD NR 9, 10/A852 15/A822 15/A822 SELF-CLOSING, -SELF-LATCHING & IN-USE <br />INDICATOR. ACCESSIBLE SIGNAGE AT DOOR PER <br />8/A089 <br />105 JANITOR CLOSET B 3' - 0" 6' - 8" 1 3/4" WOOD PAINT WOOD NR 9 /A852 15/A822 15/A822 <br />106 CLOSET B 2' - 0" 7' - 0" 1 3/4" WOOD PAINT WOOD NR 9, 10/A852 15/A822 15/A822 <br />107 LAUNDRY F 3' - 0" 6' - 8" 1 3/4" FRENCH PAINT WOOD NR 9, 10/A852 15/A822 15/A822 SELF-CLOSING & SELF-LATCHING <br />108 CLOSET C 5' - 6" 6' - 8" 1 3/4" WOOD PAINT WOOD NR 17/A822 18/A822 19/A822 BI-PASS DOOR <br />109 CORRIDOR F 3' - 0" 7' - 0" 1 3/4" FRENCH PAINT HM NR 9, 10/A852 15/A822 15/A822 SELF-CLOSING, -SELF-LATCHING & PANIC <br />HARDWARE <br />A <br />B A <br />B <br />B <br />C <br />A PC COMMENTS RESPONSE #1 01/29/2025 <br />B PC COMMENTS RESPONSE #2 04/17/2025 <br />C PC COMMENTS RESPONSE #3 07/08/2025 <br />1 DELTA 1 10/31/2025 <br />1 <br />1