Laserfiche WebLink
al <br />l <br /> <br />i <br />d <br />e <br />a <br />s <br />, <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />s <br /> <br />a <br />n <br />d <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />r <br />e <br />p <br />r <br />e <br />s <br />e <br />n <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />t <br />h <br />i <br />s <br /> <br />d <br />r <br />aw <br />i <br />n <br />g <br /> <br />a <br />r <br />e <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />c <br />l <br />u <br />s <br />i <br />v <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br /> <br />bs <br />b <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />, <br /> <br />i <br />n <br />c <br />. <br /> <br />an <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />i <br />n <br /> <br />w <br />h <br />o <br />l <br />e <br /> <br />o <br />r <br /> <br />i <br />n <br /> <br />p <br />a <br />r <br />t <br /> <br />w <br />i <br />t <br />ho <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br /> <br />p <br />r <br />i <br />o <br />r <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />o <br />f <br /> <br />s <br />a <br />i <br />d <br /> <br />a <br />rc <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />, <br /> <br />a <br />n <br />y <br /> <br />u <br />n <br />a <br />u <br />t <br />h <br />o <br />r <br />iz <br />e <br />d <br /> <br />r <br />e <br />u <br />s <br />e <br /> <br />o <br />f <br /> <br />t <br />h <br />e <br />s <br />e <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />o <br />t <br />h <br />e <br />r <br /> <br />t <br />h <br />a <br />n <br /> <br />f <br />o <br />r <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />j <br />e <br />c <br />t <br />a <br />n <br />d <br /> <br />l <br />o <br />c <br />a <br />t <br />i <br />o <br />n <br /> <br />s <br />h <br />o <br />w <br />n <br /> <br />i <br />s <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br />JOB NO. <br />SUBMITTAL <br />DATE <br />SHEET TITLE <br />SHEET NO. <br />CLIENT: <br />Plot Date:File: <br />REVISION <br />DATE <br />21 <br />3 <br />0 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br /> <br /># <br />2 <br />0 <br />0 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />1ST PLAN CHECK SUBMITTAL 08/20/2024 <br />970 W. 190TH ST., STE 250, TORRANCE CA 90502 <br />O: 310.217.8885 <br />BSBDESIGN.COM <br />D E S I G N <br />BSB <br />4TH P.C. SUBMITTAL <br />07/08/2025 <br />2ND PLAN CHECK SUBMITTAL 01/29/2025 <br />3RD PLAN CHECK SUBMITTAL 04/17/2025 <br />4TH PLAN CHECK SUBMITTAL 07/08/2025 <br />11/4/2025 8:52:23 PM <br />MR230056 <br />A041 <br />CAL GREEN Notes - Residential <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />T <br />I <br />A <br />L <br />21 <br />5 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />S <br />T <br />. <br /> <br />& <br /> <br />2 <br />1 <br />6 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br />SECTION 4.106 SITE DEVELOPMENT <br />4.106.1 GENERAL <br />PRESERVATION AND USE OF AVAILABLE NATURAL RESOURCES SHALL BE <br />ACCOMPLISHED THROUGH EVALUATION AND CAREFUL PLANNING TO MINIMIZE <br />NEGATIVE EFFECTS ON THE SITE AND ADJACENT AREAS. PRESERVATION OF SLOPES, <br />MANAGEMENT OF STORM WATER DRAINAGE AND EROSION CONTROLS SHALL COMPLY <br />WITH THIS SECTION. <br />4.106.2 STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION. <br />PROJECTS WHICH DISTURB LESS THAN ONE ACRE OF SOIL AND ARE NOT PART OF A <br />LARGER COMMON PLAN OF DEVELOPMENT WHICH IN TOTAL DISTURBS ONE ACRE OR <br />MORE, SHALL MANAGE STORM WATER DRAINAGE DURING CONSTRUCTION. IN ORDER <br />TO MANAGE STORM WATER DRAINAGE DURING CONSTRUCTION, ONE OR MORE OF <br />THE FOLLOWING MEASURES SHALL BE IMPLEMENTED TO PREVENT FLOODING OF <br />ADJACENT PROPERTY, PREVENT EROSION AND RETAIN SOIL RUNOFF ON THE SITE. <br />1. RETENTION BASINS OF SUFFICIENT SIZE SHALL BE UTILIZED TO RETAIN STORM <br />WATER ON THE SITE. <br />2. WHERE STORM WATER IS CONVEYED TO A PUBLIC DRAINAGE SYSTEM, <br />COLLECTION POINT, GUTTER OR SIMILAR DISPOSAL METHOD, WATER SHALL BE <br />FILTERED BY USE OF A BARRIER SYSTEM, WATTLE OR OTHER METHOD <br />APPROVED BY THE ENFORCING AGENCY. <br />3. COMPLIANCE WITH A LAWFULLY ENACTED STORM WATER MANAGEMENT <br />ORDINANCE. <br />NOTE: REFER TO THE STORM WATER RESOURCE CONTROL BOARD FOR THE <br />PROJECTS WHICH DISTURB ONE ACRE OR MORE OF SOIL, OR ARE PART OF A LARGER <br />COMMON PLAN OF DEVELOPMENT WHICH IN TOTAL DISTURBS ONE ACRE OR MORE OF <br />SOIL. <br />4.106.3 GRADING AND PAVING <br />CONSTRUCTION PLANS SHALL INDICATE HOW THE SITE GRADING OR DRAINAGE <br />SYSTEM WILL MANAGE ALL SURFACE WATER FLOWS TO KEEP WATER FROM ENTERING <br />BUILDINGS. EXAMPLES OF METHODS TO MANAGE SURFACE WATER INCLUDE, BUT ARE <br />NOT LIMITED TO, THE FOLLOWING: <br />1. SWALES <br />2. WATER COLLECTION AND DISPOSAL SYSTEMS <br />3. FRENCH DRAINS <br />4. WATER RETENTION GARDENS <br />5. OTHER WATER MEASURES WHICH KEEP SURFACE WATER AWAY FROM <br />BUILDINGS AND AID IN GROUNDWATER RECHARGE <br />EXCEPTION: ADDITIONS AND ALTERATIONS NOT ALTERING THE DRAINAGE PATH. <br />SECTION 4.303 <br />INDOOR WATER USE <br />4.303.1 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS <br />PLUMBING FIXTURES (WATER CLOSETS AND URINALS) AND FITTINGS (FAUCETS AND <br />SHOWERHEADS) SHALL COMPLY WITH THE FOLLOWING: <br />4.303.1.1 WATER CLOSETS. <br />THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT EXCEED 1.28 <br />GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE <br />PERFORMANCE CRITERIA OF THE U.S. EPA WATERSENSE SPECIFICATION FOR TANK- <br />TYPE TOILETS. <br />NOTE: THE EFFECTIVE FLUSH VOLUME OF DUAL FLUSH TOILETS IS DEFINED AS THE <br />COMPOSITE, AVERAGE FLUSH VOLUME OF TWO REDUCED FLUSHES AND ONE FULL <br />FLUSH. <br />4303.1.2 URINALS <br />THE EFFECTIVE FLUSH VOLUME OF WALL-MOUNTED URINALS SHALL NOT EXCEED .125 <br />GALLONS PER FLUSH. THE EFFECTIVE FLUSH VOLUME OF ALL OTHER URINALS SHALL <br />NOT EXCEED 0.5 GALLONS PER FLUSH. <br />4.303.1.3 SHOWER HEADS <br />4.303.1.3.1 SINGLE SHOWER HEADS <br />SHOWERHEADS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 1.8 <br />GALLONS PER MINUTE @ 80 PSI. SHOWERHEADS SHALL BE CERTIFIED TO THE <br />PERFORMANCE CRITERIA OF THE U.S. EPA WATERSENSE SPECIFICATION FOR <br />SHOWERHEADS. <br />4.303.1.3.2 MULTIPLE SHOWER HEADS <br />WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED <br />FLOW RATE OF ALL SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED <br />BY A SINGLE VALVE SHALL NOT EXCEED 1.8 GALLONS PER MINUTE @ 80 PSI. OR THE <br />SHOWER SHALL BE DESIGNED TO ALLOW ONLY ONE SHOWER OUTLET TO BE IN <br />OPERATION AT A TIME. <br />NOTE: A HAND-HELD SHOWER SHALL BE CONSIDERED A SHOWERHEAD. <br />4.303.1.4 FAUCETS <br />4.303.1.4.1 RESIDENTIAL LAVATORY FAUCETS. <br />THE MAXIMUM FLOW RATE OF RESIDENTIAL LAVATORY FAUCETS SHALL NOT <br />EXCEED 1.2 GALLONS PER MINUTE AT 60 PSI. THE MINIMUM <br />FLOW RATE OF RESIDENTIAL LAVATORY FAUCETS SHALL NOT BE LESS <br />THAN 0.8 GALLONS PER MINUTE AT 20 PSI. <br />4.303.1.4.2 LAVATORY FAUCETS IN COMMON AND PUBLIC USE AREAS. <br />THE MAXIMUM FLOW RATE OF LAVATORY FAUCETS INSTALLED IN COMMON AND <br />PUBLIC USE AREAS (OUTSIDE OF DWELLINGS OR SLEEPING UNITS) IN RESIDENTIAL <br />BUILDINGS SHALL NOT EXCEED 0.5 GALLONS PER MINUTE AT 60 PSI. <br />4.303.1.4.3 METERING FAUCETS. <br />METERING FAUCETS WHEN INSTALLED IN RESIDENTIAL BUILDINGS SHALL NOT <br />DELIVER MORE THAN 0.25 GALLONS PER CYCLE. <br />4.303.1.4.4 KITCHEN FAUCETS. <br />THE MAXIMUM FLOW RATE OF KITCHEN FAUCETS SHALL NOT EXCEED 1.8 GALLONS <br />PER MINUTE AT 60 PSI. KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE FLOW <br />ABOVE THE MAXIMUM RATE, BUT NOT TO EXCEED 2.2 GALLONS PER MINUTE AT 60 PSI, <br />AND MUST DEFAULT TO A MAXIMUM <br />FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. <br />NOTE: WHERE COMPLYING FAUCETS ARE UNAVAILABLE, AERATORS <br />OR OTHER MEANS MAY BE USED TO ACHIEVE REDUCTION. <br />4.303.2 STANDARDS FOR PLUMBING FIXTURES AND FITTINGS. <br />PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />CALIFORNIA PLUMBING CODE, AND SHALL MEET THE APPLICABLE STANDARDS <br />REFERENCED IN TABLE 1701.1 OF CALIFORNIA PLUMBING CODE <br />SECTION 4.304 <br />OUTDOOR WATER USE <br />4.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. <br />RESIDENTIAL DEVELOPMENTS SHALL COMPLY WITH A LOCAL WATER EFFICIENT <br />LANDSCAPE ORDINANCE OR THE CURRENT CALIFORNIA DEPARTMENT OF WATER <br />RESOURCES' MODEL WATER EFFICIENT ORDINANCE (MWELO), WHICHEVER IS MORE <br />STRINGENT. <br />NOTES: <br />1. THE MODEL WATER EFFICIENT LANDSCAPE ORDINANCE (MWELO) IS <br />LOCATED IN THE CALIFORNIA CODE OF REGULATIONS, TITLE 23, CHAPTER <br />2.7, DIVISION 2. <br />2. MWELO AND SUPPORTING DOCUMENTS INCLUDING WATER BUDGET <br />CALCULATOR, ARE AVAILABLE AT: <br />http://www.water.ca.gov <br />SECTION 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE <br />4.406.1 RODENT PROOFING. <br />ANNULAR SPACES AROUND PIPES, ELEC-TRIC CABLES, CONDUITS OR OTHER <br />OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE PROTECTED <br />AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT <br />MORTAR, CONCRETE MASONRY OR A SIMILAR METHOD ACCEPTABLE TO THE <br />ENFORCING AGENCY. <br />4.408.1 CONSTRUCTION WASTE MANAGEMENT <br />RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65 PERCENT OF THE <br />NONHAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH <br />EITHER SECTION 4.408.2, 4.408.3 OR 4.408.4, OR MEET A MORE STRINGENT LOCAL <br />CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE. <br />EXCEPTIONS: <br />1. EXCAVATED SOIL AND LAND-CLEARING DEBRIS. <br />2. ALTERNATE WASTE REDUCTION METHODS DEVELOPED BY WORKING WITH <br />LOCAL AGENCIES IF DIVERSION OR RECYCLE FACILITIES CAPABLE OF <br />COMPLIANCE WITH THIS ITEM DO NOT EXIST OR ARE NOT LOCATED REASONABLY <br />CLOSE TO THE JOBSITE. <br />3. THE ENFORCING AGENCY MAY MAKE EXCEPTIONS TO THE REQUIREMENTS OF <br />THIS SECTION WHEN ISOLATED JOBSITES ARE LOCATED IN AREAS BEYOND THE <br />HAUL BOUNDARIES OF THE DIVERSION FACILITY. <br />4.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN <br />SUBMIT A CONSTRUCTION WASTE MANAGEMENT PLAN IN CONFORMANCE WITH ITEMS <br />1 -5. THE CONSTRUCTION WASTE MANAGEMENT PLAN SHALL BE UPDATED AS <br />NECESSARY AND SHALL BE AVAILABLE DURING CONSTRUCTION FOR EXAMINATION BY <br />THE ENFORCING AGENCY. <br />1. IDENTIFY THE CONSTRUCTION & DEMOLITION WASTE MATERIALS TO BE <br />DIVERTED FROM DISPOSAL BY RECYCLING, REUSE ON THE PROJECT OR <br />SALVAGE FOR FUTURE USE. <br />2. SPECIFY IF CONSTRUCTION & DEMOLITION WASTE MATERIALS WILL BE SORTED <br />ON SITE (SOURCE-SEPARATED) OR BULK MIXED (SINGLE STREAM). <br />3. IDENTIFY DIVERSION FACILITIES WHERE THE CONSTRUCTION & DEMOLITION <br />WASTE MATERIAL WILL BE TAKEN. <br />4. IDENTIFY CONSTRUCTION METHODS EMPLOYED TO REDUCE THE AMOUNT OF <br />CONSTRUCTION & DEMOLITION WASTE GENERATED. <br />5. SPECIFY THAT THE AMOUNT OF CONSTRUCTION & DEMOLITION WASTE <br />MATERIALS DIVERTED SHALL BE CALCULATED BY WEIGHT OR VOLUME, BUT NOT <br />BY BOTH. <br />4.408.3 WASTE MANAGEMENT COMPANY <br />UTILIZE A WASTE MANAGEMENT COMPANY APPROVED BY THE ENFORCING AGENCY, <br />WHICH CAN PROVIDE VERIFIABLE DOCUMENTATION THAT THE PERCENTAGE OF <br />CONSTRUCTION & DEMOLITION WASTE MATERIAL DIVERTED FROM THE LANDFILL <br />COMPLIES WITH SECTION 4.408.1. <br />NOTE: <br />THE OWNER OR CONTRACTOR MAY MAKE THE DETERMINATION IF THE CONSTRUCTION <br />AND DEMOLITION WASTE MATERIALS WILL BE DIVERTED BY A WASTE MANAGEMENT <br />COMPANY. <br />4.408.4 WASTE STREAM REDUCTION ALTERNATIVE. <br />PROJECTS THAT GENERATE A TOTAL COMBINED WEIGHT OF CONSTRUCTION & <br />DEMOLITION WASTE DISPOSED OF IN LANDFILLS, WHICH DO NOT EXCEED 3.4 LBS./SQ. <br />FT. OF THE BUILDING AREA SHALL MEET THE MINIMUM 65 PERCENT CONSTRUCTION <br />WASTE REDUCTION REQUIREMENT IN SECTION 4.408.1. <br />4.408.4.1 WASTE STREAM REDUCTION ALTERNATIVE. <br />PROJECTS THAT GENERATE A TOTAL COMBINED WEIGHT OF CONSTRUCTION <br />AND DEMOLITION WASTE DISPOSED OF IN LANDFILLS, WHICH DO NOT <br />EXCEED TWO (2) POUNDS PER SQUARE FOOT OF THE BUILDING AREA, <br />SHALL MEET THE MINIMUM 65-PERCENT CONSTRUCTION WASTE <br />REDUCTION REQUIREMENT IN SECTION 4.408.1. <br />4.408.5 DOCUMENTATION SHALL BE PROVIDED TO THE ENFORCING AGENCY WHICH <br />DEMONSTRATES COMPLIANCE WITH SECTION 4.408.2, ITEMS 1-5, SECTION 4.408.3 OR <br />4.408.4. <br />SECTION 4.410 <br />BUILDING MAINTENANCE AND OPERATION <br />4.410.1 OPERATION AND MAINTENANCE MANUAL. <br />AT THE TIME OF FINAL INSPECTION, A MANUAL, COMPACT DISC, WEB-BASED <br />REFERENCE OR OTHER MEDIA ACCEPTABLE TO THE ENFORCING AGENCY WHICH <br />INCLUDES ALL OF THE FOLLOWING SHALL BE PLACED IN THE BUILDING: <br />1. DIRECTIONS TO THE OWNER OR OCCUPANT THAT THE MANUAL SHALL <br />REMAIN WITH THE BUILDING THROUGHOUT THE LIFE CYCLE OF THE <br />STRUCTURE. <br />2. OPERATION AND MAINTENANCE INSTRUCTIONS FOR THE FOLLOWING: <br />a. EQUIPMENT AND APPLIANCES, INCLUDING WATER-SAVING DEVICES <br />AND SYSTEMS, HVAC SYSTEMS, PHOTOVOLTAIC SYSTEMS, ELECTRIC <br />VEHICLE CHARGERS, WATER-HEATING SYSTEMS AND OTHER MAJOR <br />APPLIANCES AND EQUIPMENT. <br />b. ROOF AND YARD DRAINAGE, INCLUDING GUTTERS AND <br />DOWNSPOUTS. <br />c. SPACE CONDITIONING SYSTEMS, INCLUDING CONDENSERS AND AIR <br />FILTERS. <br />d. LANDSCAPE IRRIGATION SYSTEMS. <br />e. WATER REUSE SYSTEMS. <br />3. INFORMATION FROM LOCAL UTILITY, WATER AND WASTE RECOVERY <br />PROVIDERS ON METHODS TO FURTHER REDUCE RESOURCE <br />CONSUMPTION, INCLUDING RECYCLE PROGRAMS AND LOCATIONS. <br />4. PUBLIC TRANSPORTATION AND/OR CARPOOL OPTIONS AVAILABLE IN THE <br />AREA. <br />5. EDUCATIONAL MATERIAL ON THE POSITIVE IMPACTS OF AN INTERIOR <br />RELATIVE HUMIDITY BETWEEN 30-60 PERCENT AND WHAT METHODS AN <br />OCCUPANT MAY USE TO MAINTAIN THE RELATIVE HUMIDITY LEVEL IN THAT <br />RANGE. <br />6. INFORMATION ABOUT WATER-CONSERVING LANDSCAPE AND IRRIGATION <br />DESIGN AND CONTROLLERS WHICH CONSERVE WATER. <br />7. INSTRUCTIONS FOR MAINTAINING GUTTERS AND DOWNSPOUTS AND THE <br />IMPORTANCE OF DIVERTING WATER AT LEAST 5 FEET AWAY FROM THE <br />FOUNDATION. <br />8. INFORMATION ON REQUIRED ROUTINE MAINTENANCE MEASURES, <br />INCLUDING, BUT NOT LIMITED TO, CAULKING, PAINTING, GRADING AROUND <br />THE BUILDING, ETC. <br />9. INFORMATION ABOUT STATE SOLAR ENERGY AND INCENTIVE PROGRAMS <br />AVAILABLE. <br />10. A COPY OF ALL SPECIAL INSPECTIONS VERIFICATIONS REQUIRED BY THE <br />ENFORCING AGENCY OR THIS [CALIFORNIA GREEN BUILDING STANDARDS] <br />CODE. <br />11. INFORMATION FROM THE DEPARTMENT OF FORESTRY AND FIRE <br />PROTECTION ON MAINTENANCE OF DEFENSIBLE SPACE AROUND <br />RESIDENTIAL STRUCTURES. <br />12. INFORMATION AND/OR DRAWINGS IDENTIFYING THE LOCATION OF GRAB <br />BAR REINFORCEMENTS. <br />4.410.2 RECYCLING PER OCCUPANTS <br />WHERE 5 OR MORE MULTIFAMILY DWELLING UNITS ARE CONSTRUCTED ON A BUILDING <br />SITE, PROVIDE READILY ACCESSIBLE AREA(S) THAT SERVES ALL BUILDINGS ON THE <br />SITE AND IS IDENTIFIED FOR THE DEPOSITING, STORAGE AND COLLECTION OF NON- <br />HAZARADOUS MATERIALS FOR RECYCLING, INCLUDING (AT A MINIMUM) PAPER, <br />CORRUGATED CARDBOARD, GLASS, PLASTICS, ORGANIC WASTER, AND METALS, OR <br />MEET A LAWFULLY ENACTED LOCAL RECYCLING ORDINANCE, IF MORE RESTRICTIVE. <br />SECTION 4.503 <br />FIREPLACES <br />4.503.1 GENERAL. <br />ANY INSTALLED GAS FIREPLACE SHALL BE A DIRECT-VENT SEALED-COMBUSTION TYPE. <br />ANY INSTALLED WOODSTOVE OR PELLET STOVE SHALL COMPLY WITH U.S. EPA NEW <br />SOURCE PERFORMANCE STANDARDS (NSPS) EMISSION LIMITS AS APPLICABLE AND <br />SHALL HAVE A PERMANENT LABEL INDICATING THEY ARE CERTIFIED TO MEET THE <br />EMISSION LIMITS. WOODSTOVES, PELLET STOVES AND FIREPLACES SHALL ALSO <br />COMPLY WITH APPLICABLE LOCAL ORDINANCES. <br />SECTION 4.504 <br />POLLUTANT CONTROL <br />4.504.1 COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL EQUIPMENT <br />DURING CONSTRUCTION. <br />AT THE TIME OF ROUGH INSTALLATION OR DURING STORAGE ON THE CONSTRUCTION <br />SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING <br />EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT <br />OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL OR OTHER <br />METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF <br />WATER, DUST AND DEBRIS WHICH MAY ENTER THE SYSTEM. <br />4.504.2 FINISH MATERIAL POLLUTANT CONTROL. <br />FINISH MATERIALS SHALL COMPLY WITH THIS SECTION. <br />4.504.2.1 ADHESIVES, SEALANTS AND CAULKS. <br />ADHESIVES, SEALANTS AND CAULKS USED ON THE PROJECT SHALL MEET THE <br />REQUIREMENTS OF THE FOLLOWING STANDARDS UNLESS MORE STRINGENT <br />LOCAL OR REGIONAL AIR POLLUTION OR AIR QUALITY MANAGEMENT <br />DISTRICT RULES APPLY: <br />1. ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS, <br />SEALANT PRIMERS, AND CAULKS SHALL COMPLY WITH LOCAL OR REGIONAL AIR <br />POLLUTION CONTROL OR AIR QUALITY MANAGEMENT DISTRICT RULES WHERE <br />APPLICABLE OR SCAQMD RULE 1168 VOC LIMITS, AS SHOWN IN TABLE 4.504.1 OR <br />4.504.2, AS APPLICABLE. SUCH PRODUCTS ALSO SHALL COMPLY WITH THE RULE <br />1168 PROHIBITION ON THE USE OF CERTAIN TOXIC COMPOUNDS (CHLOROFORM, <br />ETHYLENE DICHLORIDE, METHYLENE CHLORIDE, PERCHLOROETHYLENE AND <br />TRICHLOROETHYLENE), EXCEPT FOR AEROSOL PRODUCTS, AS SPECIFIED IN <br />SUBSECTION 2 BELOW. <br />2. AEROSOL ADHESIVES, AND SMALLER UNIT SIZES OF ADHESIVES, AND SEALANT <br />OR CAULKING COMPOUNDS (IN UNITS OF PRODUCT, LESS PACKAGING, WHICH DO <br />NOT WEIGH MORE THAN 1 POUND AND DO NOT CONSIST OF MORE THAN 16 FLUID <br />OUNCES) SHALL COMPLY WITH STATEWIDE VOC STANDARDS AND OTHER <br />REQUIREMENTS, INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC <br />COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS, TITLE 17, COMMENCING <br />WITH SECTION 94507. <br />4.504.2.2 PAINTS AND COATINGS. <br />ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH VOC LIMITS IN TABLE 1 <br />OF THE ARB ARCHITECTURAL SUGGESTED CONTROL MEASURE, AS SHOWN IN TABLE <br />4.504.3, UNLESS MORE STRINGENT LOCAL LIMITS APPLY. THE VOC CONTENT LIMIT FOR <br />COATINGS THAT DO NOT MEET THE DEFINITIONS FOR THE SPECIALTY COATINGS <br />CATEGORIES LISTED IN TABLE 4.504.3 SHALL BE DETERMINED BY CLASSIFYING THE <br />COATING AS A FLAT, NONFLAT OR NONFLAT-HIGH GLOSS COATING, BASED ON ITS <br />GLOSS, AS DEFINED IN SUBSECTIONS 4.21, 4.36, AND 4.37 OF THE 2007 CALIFORNIA AIR <br />RESOURCES BOARD, SUGGESTED CONTROL MEASURE, AND THE CORRESPONDING <br />FLAT, NONFLAT OR NONFLAT-HIGH GLOSS VOC LIMIT IN TABLE 4.504.3 SHALL <br />APPLY. <br />4.504.2.3 AEROSOL PAINTS AND COATINGS. <br />AEROSOL PAINTS AND COATINGS SHALL MEET THE PRODUCT-WEIGHTED MIR LIMITS <br />FOR ROC IN SECTION 94522(A)(2) AND OTHER REQUIREMENTS, INCLUDING <br />PROHIBITIONS ON USE OF CERTAIN TOXIC COMPOUNDS AND OZONE DEPLETING <br />SUBSTANCES, IN SECTIONS 94522(E)(1) AND (F)(1) OF CALIFORNIA CODE OF <br />REGULATIONS, TITLE 17, COMMENCING WITH SECTION 94520; AND IN AREAS UNDER <br />THE JURISDICTION OF THE BAY AREA AIR QUALITY MANAGEMENT DISTRICT <br />ADDITIONALLY COMPLY WITH THE PERCENT VOC BY WEIGHT OF PRODUCT LIMITS OF <br />REGULATION 8, RULE 49. <br />4.504.2.4 VERIFICATION. <br />VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AT THE <br />REQUEST OF THE ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS NOT <br />LIMITED TO THE FOLLOWING: <br />1. MANUFACTURER'S PRODUCT SPECIFICATION. <br />2. FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS. <br />4.504.3 CARPET SYSTEMS. <br />ALL CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE REQUIREMENTS <br />OF THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, “STANDARD METHOD FOR THE <br />TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM <br />INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS,”VERSION 1.2, JANUARY 2017 <br />(EMISSION TESTING METHOD FOR CALIFORNIA SPECIFICATION 01350). <br />SEE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH’S WEBSITE FOR CER-TIFICATION <br />PROGRAMS AND TESTING LABS. <br />HTTPS://WWW.CDPH.CA.GOV/PROGRAMS/CCDPHP/DEODC/EHLB/IAQ/PAGES/VOC.ASPX <br />4.504.3.1 CARPET CUSHION. <br />ALL CARPET CUSHION INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE <br />REQUIREMENTS OF THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, “STANDARD <br />METHOD FOR THE TESTING AND EVALUATION OF VOLATILE ORGANIC CHEMICAL <br />EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS,”VERSION <br />1.2, JANUARY 2017 (EMISSION TESTING METHOD FOR CALIFORNIA SPECIFICATION <br />01350). <br />SEE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH’S WEBSITE FOR CERTIFICATION <br />PROGRAMS AND TESTING LABS. <br />HTTPS://WWW.CDPH.CA.GOV/PROGRAMS/CCDPHP/DEODC/EHLB/IAQ/PAGES/VOC.ASPX <br />4.504.3.2 CARPET ADHESIVE. <br />ALL CARPET ADHESIVE SHALL MEET THE REQUIREMENTS OF TABLE 4.504.1. <br />4.504.4 RESILIENT FLOORING SYSTEMS. <br />WHERE RESILIENT FLOORING IS INSTALLED, AT LEAST 80 PERCENT OF FLOOR AREA <br />RECEIVING RESILIENT FLOORING SHALL MEET THE REQUIREMENTS OF THE <br />CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, “STANDARD METHOD FOR THE TESTING <br />AND EVALUATION OF VOLATILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR <br />SOURCES USING ENVIRONMENTAL CHAMBERS,”VERSION <br />1.2, JANUARY 2017 (EMISSION TESTING METHOD FOR CALIFORNIA SPECIFICATION <br />01350). <br />SEE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH’S WEBSITE FOR CER-TIFICATION <br />PROGRAMS AND TESTING LABS. <br />HTTPS://WWW.CDPH.CA.GOV/PROGRAMS/CCDPHP/DEODC/EHLB/IAQ/PAGES/VOC.ASPX <br />4.504.5 COMPOSITE WOOD PRODUCTS. <br />HARDWOOD PLYWOOD, PARTICLEBOARD AND MEDIUM DENSITY FIBERBOARD <br />COMPOSITE WOOD PRODUCTS USED ON THE INTERIOR OR EXTERIOR OF THE <br />BUILDING SHALL MEET THE REQUIREMENTS FOR FORMALDEHYDE AS SPECIFIED IN <br />ARB'S AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD (17 CCR <br />93120 ET SEQ.), BY OR BEFORE THE DATES SPECIFIED IN THOSE SECTIONS, <br />AS SHOWN IN TABLE 4.504.5. <br />4.504.5.1 DOCUMENTATION. <br />VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED AS <br />REQUESTED BY THE ENFORCING AGENCY. DOCUMENTATION SHALL INCLUDE AT LEAST <br />ONE OF THE FOLLOWING: <br />1. PRODUCT CERTIFICATIONS AND SPECIFICATIONS <br />2. CHAIN OF CUSTODY CERTIFICATIONS <br />1. PRODUCT LABELED AND INVOICED AS MEETING THE COMPOSITE WOOD <br />PRODUCTS REGULATION. (SEE CCR, TITLE 17, SECTION 93120, ET SEQ.). <br />3. EXTERIOR GRADE PRODUCTS MARKED AS MEETING THE PS-1 OR PS-2 <br />STANDARDS OF THE ENGINEERED WOOD ASSOCIATION, AUSTRALIAN AS/NZS <br />2269 OR EUROPEAN 636 3S STANDARDS, AND CANADIAN CSA 0121, CSA 0151, CSA <br />0153 AND CSA 0325 STANDARDS. <br />4. OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY. <br />SECTION 4.505 <br />INTERIOR MOISTURE CONTROL <br />4.505.1 GENERAL. <br />BUILDINGS SHALL MEET OR EXCEED THE PROVISIONS OF THE CALIFORNIA BUILDING <br />STANDARDS CODE. <br />4.505.2 CONCRETE SLAB FOUNDATIONS. <br />CONCRETE SLAB FOUNDATIONS REQUIRED TO HAVE A VAPOR RETARDER BY <br />CALIFORNIA BUILDING CODE, CHAPTER 19, OR CONCRETE SLAB ON GRADE FLOORS <br />REQUIRED TO HAVE A VAPOR RETARDER BY THE CALIFORNIA RESIDENTIAL CODE, <br />CHAPTER 5, SHALL ALSO COMPLY WITH THIS SECTION. <br />4.505.2.1 CAPILLARY BREAK. <br />A CAPILLARY BREAK SHALL BE INSTALLED IN COMPLIANCE WITH AT LEAST ONE OF THE <br />FOLLOWING: <br />1. A 4-INCH (101.6 MM) THICK BASE OF 1/2 INCH (12.7 MM) OR LARGER CLEAN <br />AGGREGATE SHALL BE PROVIDED WITH A VAPOR RETARDER IN DIRECT CONTACT <br />WITH CONCRETE AND A CONCRETE MIX DESIGN, WHICH WILL ADDRESS <br />BLEEDING, SHRINKAGE, AND CURLING, SHALL BE USED. FOR ADDITIONAL <br />INFORMATION, SEE AMERICAN CONCRETE INSTITUTE, ACI 302.2R-06. <br />2. OTHER EQUIVALENT METHODS APPROVED BY THE ENFORCING AGENCY. <br />3. A SLAB DESIGN SPECIFIED BY A LICENSED DESIGN PROFESSIONAL. <br />4.505.3 MOISTURE CONTENT OF BUILDING MATERIALS. <br />BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHALL NOT BE <br />INSTALLED. WALL AND FLOOR FRAMING SHALL NOT BE ENCLOSED WHEN THE FRAMING <br />MEMBERS EXCEED 19 PERCENT MOISTURE CONTENT. MOISTURE CONTENT SHALL BE <br />VERIFIED IN COMPLIANCE WITH THE FOLLOWING: <br />1. MOISTURE CONTENT SHALL BE DETERMINED WITH EITHER A PROBE-TYPE OR <br />CONTACT-TYPE MOISTURE METER. EQUIVALENT MOISTURE VERIFICATION <br />METHODS MAY BE APPROVED BY THE ENFORCING AGENCY AND SHALL SATISFY <br />REQUIREMENTS FOUND IN SECTION 101.8 OF THIS CODE. <br />2. MOISTURE READINGS SHALL BE TAKEN AT A POINT 2 FEET (610 MM) TO 4 FEET <br />(1219 MM) FROM THE GRADE STAMPED END OF EACH PIECE TO BE VERIFIED. <br />3. AT LEAST THREE RANDOM MOISTURE READINGS SHALL BE PERFORMED ON <br />WALL AND FLOOR FRAMING WITH DOCUMENTATION ACCEPTABLE TO THE <br />ENFORCING AGENCY PROVIDED AT THE TIME OF APPROVAL TO ENCLOSE THE <br />WALL AND FLOOR FRAMING. <br />INSULATION PRODUCTS WHICH ARE VISIBLY WET OR HAVE A HIGH <br />MOISTURE CONTENT SHALL BE REPLACED OR ALLOWED TO DRY PRIOR TO <br />ENCLOSURE IN WALL OR FLOOR CAVITIES. WET-APPLIED INSULATION PRODUCTS <br />SHALL FOLLOW THE MANUFACTURERS' DRYING RECOMMENDATIONS <br />PRIOR TO ENCLOSURE. <br />SECTION 4.506 <br />INDOOR AIR QUALITY AND EXHAUST <br />4.506.1 BATHROOM EXHAUST FANS. <br />EACH BATHROOM SHALL BE MECHANICALLY VENTILATED AND SHALL COMPLY WITH <br />THE FOLLOWING: <br />1. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE <br />OUTSIDE THE BUILDING. <br />2. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION <br />SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL. <br />A. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A <br />RELATIVE HUMIDITY RANGE OF LESS THAN OR EQUAL TO 50 PERCENT TO A <br />MAXIMUM 80 PERCENT. A HUMIDITY CONTROL MAY UTILIZE MANUAL OR <br />AUTOMATIC MEANS OF ADJUSTMENT. <br />B. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO THE EXHAUST <br />FAN AND IS NOT REQUIRED TO BE INTEGRAL (BUILT-IN). <br />SECTION 4.507 <br />ENVIRONMENTAL COMFORT <br />4.507.2 HEATING AND AIR-CONDITIONING SYSTEM DESIGN. <br />HEATING AND AIR-CONDITIONING SYSTEMS SHALL BE SIZED, DESIGNED AND <br />HAVE THEIR EQUIPMENT SELECTED USING THE FOLLOWING METHODS: <br />1. THE HEAT LOSS AND HEAT GAIN IS ESTABLISHED ACCORDING TO ANSI/ACCA 2 <br />MANUAL J, -2016 (RESIDENTIAL LOAD CALCULATION), ASHRAE HANDBOOKS OR <br />OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. <br />2. DUCT SYSTEMS ARE SIZED ACCORDING TO ANSI/ACCA 1 MANUAL D -2016 <br />(RESIDENTIAL DUCT SYSTEMS),ASHRAE HANDBOOKS OR OTHER EQUIVALENT <br />DESIGN SOFTWARE OR METHODS. <br />3. SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ANSI/ACCA 3 <br />MANUAL S-2014 (RESIDENTIAL EQUIPMENT SELECTION) OR OTHER EQUIVALENT <br />DESIGN SOFTWARE OR METHODS. <br />EXCEPTION: USE OF ALTERNATE DESIGN TEMPERATURES NECESSARY TO <br />ENSURE THE SYSTEMS FUNCTION ARE ACCEPTABLE. <br />CAL GREEN RESIDENTIAL MANDATORY MEASURES NOTES <br />1. INSULATION SHALL BE GREEN GUARD CERTIFIED. <br />2. USE OF MATERIALS FOR ALL CABINETS, COUNTERTOPS AND SHELVING THAT IS <br />FREE OF ADDED FORMALDEHYDE OR FULLY SEALED ON ALL SIX SIDES BY <br />LAMINATES AND/OR A LOW-VOC PRIMER OR SEALANT (150 g/l OR LESS). <br />3. CARPET WILL CONTAIN RECYCLED CONTENT OR THAT RECYCLED CONTENT <br />AGGREGATE FOR THE ROAD BASE (CLIENT TO DETERMINE). <br />4. AT MINIMUM THE PROJECT SHALL RECYCLE AND/OR SALVAGE 65% OF NON- <br />HAZARDOUS CONSTRUCTION AND DEMOLITION DEBRIS. <br />SUSTAINABILITY NOTES <br />PRIOR TO THE FINAL INSPECTION THE LICENSED CONTRACTOR, ARCHITECT OR <br />ENGINEER IN RESPONSIBLE CHARGE OF THE OVERALL CONSTRUCTION MUST PROVIDE <br />TO THE BUILDING DEPARTMENT OFFICIAL WRITTEN VERIFICATION THAT ALL <br />APPLICABLE PROVISIONS FROM THE GREEN BUILDING STANDARDS CODE HAVE BEEN <br />IMPLEMENTED AS PART OF THE CONSTRUCTION. CGC 102.3 <br />COMPLIANCE NOTES