Laserfiche WebLink
A B C <br />1 <br />2 <br />3 <br />4 <br />D <br />ROOF FRAMING <br />PLAN <br />KITCHEN REMODEL <br />2431 BONNIE BRAE <br />SANTA ANA, CA, 92706 <br />25-1021 <br />6/2/2025 <br />1/4" = 1'-0" <br />S101 <br />Jeffrey Schaefer, P.E. <br />(562) 850-1223 <br />License Number - C91734 <br />Expiration Date - Dec 31, 2026 <br />3325 E 4th St. <br />Long Beach, CA 90814 <br />N <br />(E) RIDGE BOARD <br />OUTLINE OF FIRST <br />FLOOR WALLS <br />OUTLINE OF SECOND <br />FLOOR WALLS <br />(E) 2X8 RR @ 24" <br />O.C. TO REMAIN <br />(E) 2X8 RR @ 24" <br />O.C. TO REMAIN <br />(E) 2X8 RR <br />@ 24" O.C. <br />TO REMAIN <br />(E <br />) <br /> <br />R <br />I <br />D <br />G <br />E <br /> <br />B <br />O <br />A <br />R <br />D <br />(E) 2X8 RR <br />@ 24" O.C. <br />TO REMAIN <br />(E <br />) <br /> <br />2 <br />X <br />8 <br /> <br />R <br />R <br /> <br />@ <br /> <br />2 <br />4 <br />" <br />O. <br />C <br />. <br /> <br />T <br />O <br /> <br />R <br />E <br />M <br />A <br />I <br />N <br />(E <br />) <br /> <br />2 <br />X <br />8 <br /> <br />R <br />R <br /> <br />@ <br /> <br />2 <br />4 <br />" <br />O. <br />C <br />. <br /> <br />T <br />O <br /> <br />R <br />E <br />M <br />A <br />I <br />N <br />(E <br />) <br /> <br />2 <br />X <br />8 <br /> <br />R <br />R <br /> <br />@ <br /> <br />2 <br />4 <br />" <br />O. <br />C <br />. <br /> <br />T <br />O <br /> <br />R <br />E <br />M <br />A <br />I <br />N <br />(E <br />) <br /> <br />2 <br />X <br />8 <br /> <br />R <br />R <br /> <br />@ <br /> <br />2 <br />4 <br />" <br />O. <br />C <br />. <br /> <br />T <br />O <br /> <br />R <br />E <br />M <br />A <br />I <br />N <br />(E <br />) <br /> <br />R <br />I <br />D <br />G <br />E <br /> <br />B <br />O <br />A <br />R <br />D <br />(E) ROOF BEAM TO REMAIN <br />(E <br />) <br /> <br />2 <br />X <br />8 <br /> <br />R <br />R <br /> <br />@ <br /> <br />2 <br />4 <br />" <br />O. <br />C <br />. <br /> <br />T <br />O <br /> <br />R <br />E <br />M <br />A <br />I <br />N <br />(E) RIDGE BOARD <br />OUTLINE OF SECOND <br />FLOOR WALLS <br />(E) 5.25X14 2.2E PSL 2ND FLOOR BEAM (E) 6X12 2ND FLOOR BEAM (E) 6X12 2ND FLOOR BEAM <br />(E <br />) <br /> <br />5 <br />. <br />2 <br />5 <br />X <br />1 <br />1 <br />. <br />2 <br />5 <br /> <br />P <br />S <br />L <br /> <br />2 <br />N <br />D <br /> <br />F <br />L <br />O <br />O <br />R <br />/ <br /> <br />B <br />E <br />A <br />M <br />(E) 6X12 2ND FLOOR BEAM <br />(E <br />) <br /> <br />5 <br />. <br />2 <br />5 <br />X <br />1 <br />1 <br />. <br />2 <br />5 <br /> <br />P <br />S <br />L <br /> <br />2 <br />N <br />D <br /> <br />F <br />L <br />O <br />O <br />R <br />/ <br /> <br />B <br />E <br />A <br />M <br />(E) 6X12 2ND FLOOR BEAM(E) 6X12 2ND FLOOR BEAM <br />14 <br />' <br />- <br />0 <br />" <br />STRUCTURAL ENGINEERING <br />1. ON SITE VERIFICATION OF ALL DIMENSIONS AND CONDITIONS SHALL BE THE RESPONSIBILITY OF <br />THE CONTRACTOR AND SUB-CONTRACTORS. NOTES AND DIMENSIONS TAKES PRECEDENCE OVER <br />SCALING OF THE DRAWING. EACH CONTRACTOR OR SUB-CONTRACTOR SHALL REPORT TO <br />PROJECT OWNER AND DESIGNER ALL CONDITIONS WHICH PREVENT THE PROPER EXECUTION OF <br />THEIR WORK. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS <br />2. NO DEVIATIONS FROM STRUCTURAL DETAILS SHALL BE MADE WITHOUT THE WRITTEN APPROVAL <br />OF THE STRUCTURAL DESIGN ENGINEER. APPROVAL BY CITY INSPECTOR DOES NOT CONSTITUTE <br />AUTHORITY TO DEVIATE FROM PLANS OR SPECIFICATIONS. <br />3. STRUCTURAL DESIGN DOES NOT CONSIDER EFFECTS OF MECHANICAL EQUIPMENT. <br />4. THE DESIGN ADEQUACY AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, <br />ETC. IS SOLE RESPONSIBILITY OF THE CONTRACTOR AND HAS NOT BEEN CONSIDERED BY THE <br />ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE PRIOR TO <br />THE APPLICATION OF ALL SHEAR WALLS, ROOF AND FLOOR DIAPHRAGMS AND FINISH MATERIALS. <br />STRUCTURAL DESIGN CRITERIA <br />1. SOIL BEARING CAPACITY ASSUMED TO BE 1,500 PSF <br />2. DESIGN VALUES ARE BASED OFF THE FOLLOWING CRITERIA: <br />2.1. RISK CATEGORY: II <br />2.2. GROUND FLOOR LIVE LOAD: 40 PSF <br />2.3. ROOF LIVE LOAD: 20 PSF <br />2.4. ROOF DEAD LOAD: 15 PSF (19 PSF WHERE SOLAR PANELS) <br />2.5. FLOOR LIVE LOAD: 30 PSF (BEDROOM AREA) <br />2.6. FLOOR LIVE LOAD: 40 PSF (OTHER AREAS) <br />2.7. FLOOR DEAD LOAD: 15 PSF <br />2.8. GROUND SNOW LOAD: 0 PSF <br />2.9. BASIC WIND SPEED: 95 MPH <br />2.10. EXPOSURE CATEGORY: B <br />2.11. ENCLOSURE CLASSIFICATION: ENCLOSED <br />2.12. SEISMIC SITE CLASS: D <br />2.13. SEISMIC DESIGN CATEGORY: D <br />2.14. RESPONSE MODIFICATION FACTOR: 6.5 <br />2.15. SEISMIC DESIGN COEFFICIENTS: SDS=1.19, SD1=0.82 <br />1 <br />S104 <br />2 <br />S104 <br />3 <br />S104 <br />3 <br />(E <br />) <br /> <br />2 <br />X <br />8 <br /> <br />F <br />J <br /> <br />@ <br /> <br />1 <br />6 <br />" <br />O. <br />C <br />. <br /> <br />T <br />O <br /> <br />R <br />E <br />M <br />A <br />I <br />N <br />REMOVE EXISTING BEAM / POST AND <br />REPLACE WITH NEW 5.25X11.25 2.2E PSL <br />BEAM. EXISTING FLOOR BEAMS TO BEAR <br />DIRECTLY OVERTOP NEW PSL BEAM. BOTTOM <br />OF BEAM TO ALIGN WITH EXISTING CEILING <br />JOISTS (NO DROP BEAM). EXISTING CEILING <br />FLOOR CAVITY SUFFICIENT DEPTH TO <br />ACCOMMODATE BEAM AND FLUSH CEILING <br />(E) 2X6 CJ @ 16" <br />O.C. TO REMAIN <br />(E) 2X6 CJ @ 16" <br />O.C. TO REMAIN <br />S104 <br />(E) 2X6 CJ @ 16" <br />O.C. TO REMAIN <br />(E <br />) <br /> <br />2 <br />X <br />8 <br /> <br />F <br />J <br /> <br />@ <br /> <br />1 <br />6 <br />" <br />O. <br />C <br />. <br /> <br />T <br />O <br /> <br />R <br />E <br />M <br />A <br />I <br />N <br />(E) 2X6 CJ <br />@ 16" o.c. <br />(E) 2X6 CJ <br />@ 16" o.c. <br />601 N. Ross Street, Santa Ana,CA 92701 <br />P.O.Box 4048, Santa Ana,CA 92702-4048 <br />www.ocpublicworks.com <br />714.667.8888| myOCeServices.ocgov.com <br />Special Inspection Program and Designation of <br />Special Inspectors <br />SPECIAL INSPECTIONS <br />(Only checked items are required) <br />INSPECTION ITEMS <br />SPECIAL INSPECTORS(S) <br />NAME, PHONE NUMBER, REGISTRATION # <br />□Concrete (Design Mix, Form Work, Placement, etc., per table 1705.3) <br />□Erection of Pre-Cast Concrete Members <br />□Bolts Installed in Concrete <br />□Reinforcing Steel and Pre-Stressing Steel Tendons <br />□Structural Welding/Rebar Welding <br />□High-Strength Bolting/Material Verification <br />□Steel Frame Joint Details <br />□All Masonry Construction <br />□Sprayed Fire-Resistive Materials <br />□Shotcrete (Curing Temperature, Design Mix, Placement, Strength <br />etc. per table 1705.3) <br />□Soils (Excavation, Fill, etc. per table 1705.6) <br />□Smoke-Control System <br />□Driven Piles per Table 1705.7 <br />□Cast in Place Piles per Table 1705.8 <br />□Mastic and Intumescent Fire-Resistant Coatings <br />□Exterior Insulation and Finish Systems (EIFS) <br />□Wood for High-Load Diaphragms <br />□Others <br />□Others <br />□Others <br />□Others <br />DECLARATION BY OWNER OR ARCHITECT/ENGINEER OFRECORD: <br />I, the □ Owner □ Engineer or □ Architect of record, declare that the above listed Special Inspector(s) is/are hired by me. <br />_____________________________ _______________________________ _____________________ <br />Print Name Signature Date <br />NON <br />E <br /> <br />R <br />E <br />Q <br />U <br />I <br />R <br />E <br />D <br />N/A N/A N/A <br />300 N. Flower Street, Santa Ana, CA 92703 www.ocpublicworks.com <br />P.O. Box 4048, Santa Ana, CA 92702-4048 <br />Revised 02/2017 <br />P:714.667.8888 I F: 714.667.7575 <br /> ocpCustomerCare@ocpw.ocgov.com <br />Structural Observation Program <br />Designation of Structural Observation <br />PROJECT ADDRESS: _______________________________ PERMIT APPL. NO.__________ <br />Description of Work: ____________________________________________________________________ <br />Owner: _______________________ Architect: ________________________ Engineer: _______________ <br />DECLARATION BY OWNER I, the Owner of the project, declare that the above listed firm or individual <br />is hired by me to be the Structural Observer. <br />Signature______________________________ Date _________________ <br />Declaration by Engineer or Architect of Record (required if different from the listed Structural Observer) I, the <br />Engineer or Architect of record for the project, declare that the above listed firm or individual is designated by me <br />to be responsible for the Structural Observation. <br />Signature______________________________ Date__________________ <br />STRUCTURAL OBSERVATION (Only checked items are required) <br />Firm or individual to be responsible for the Structural Observation: <br />Name: Phone: (562) 850-1223 Calif. Registration: <br />FOUNDATION WALL FRAME DIAPHRAGM <br />Footing, Stem Walls, Piers Concrete Steel Moment Frame Concrete <br />Mat Foundation Masonry Steel Braced Frame Steel Deck <br />Caisson, Piles, Grade Beams Wood Concrete Moment Frame Wood <br />Stepp’g/Retaining Foundation, <br />Hillside Special Anchors <br />Others:Masonry Wall Frame Others: <br />The structure is classified as Occupancy Category III or IV. <br />The Height of the structure is greater then 75 feet (22,860 mm) above the base. The structure is assigned to Seismic <br />Design Category E, is classified as Occupancy Category I or II. <br />2431 Bonnie Brae, Santa Ana 92706 101125207 <br />Kitchen remodel, includes removal of interior load-bearing wall <br />Jeffrey Schaefer, P.E.Allison and David Levy <br />Jeffrey Schaefer, P.E. <br />NONE REQUIRED <br />C91734 <br />N/A N/A <br />N/A N/A