Laserfiche WebLink
October 1, 2013 SIGN COMPONENTS MANUAL (SAM)150 <br />4. Power Supply is intended for use in indoor Dry and Damp location only. <br />5. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of housing. Adjacent power supplies shall be spaced at least 1 in. end to end and 4 in. in <br />any other direction. If required spacings are not provided, a temperature test is required. <br />6. The input and output leads were not subjected to the strain relief test. <br />7. The primary (Black-White) and the output (Red-Black) connection wires of the power supply are R/C (AVLV2), (AVL\/8)/CN, 18 <br />AWG, 90°C. The suitability of the leads shall be determined in the end-use application. <br />8. The metal case must be grounded in the end use. <br />LED Class 2 Modules, designated as Cat. Nos. LSA-25W, LSA-25WH, LSA-25R and LSA-25WW 1. These products are only <br />suitable for connection to a Class 2 power source rated 12 Volt DC or less. <br />2. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output <br />rating of the Class 2 supply. <br />3. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volts DC or less. <br />4. These products are not required to be enclosed or protected from the weather in the end product. <br />5. These products may be secured in place in the end product by any means available. <br />LED Power Supply with Class 2 output, models L12V60UNV-Q, and D12V60UNV-Q. <br />1. The drivers shall be installed in compliance with the applicable requirements of the end-product standard for, mounting, spacing, <br />casualty and segregation. <br />2. The maximum available output parameters were within the maximum allowable limits for Class 2, inherently limited as specified <br />in the UL 1310, Standard for Class 2 Power Units for wet location and also in accordance with the Canadian Safety Standard <br />CSA C22.2 No. 223. <br />3. The drivers were tested for a maximum manufacturer's recommended Tc location, should not exceed 69°C, in ambient of 40°C. <br />If adjacent LED power supplies are spaced closer than 1 in. end to end or 4 in. side to side a temperature test shall be <br />conducted in the end use product. <br />4. The drivers are suitable for use in "DRY", "DAMP", and 'WET" locations. <br />5. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. Adjacent power supplies shall be spaced at least 1 in. end to end and 4 in. in <br />any other direction. <br />6. The input and output leads were not subjected to the strain relief test. However, the drivers are potted and the need to perform <br />the Strain Relief and/or Pushback Relief Tests on the lead wires should be determined in the end-use application. <br />7. The primary (Black/White/GREEN) and the output (Red-Black) connection wires of the power supply are R/C (AVLV2/AVLV8), <br />18 AWG, 90°C. The suitability of the leads shall be determined in the end-use application. <br />8. The leakage current test was performed in accordance with the UI 1310 standard while the driver was connected to a 120 V and <br />also while connected to a 240 V source of supply and the maximum measured leakage current was 0.25 mA. Therefore, a <br />maximum of two LED Drivers can be used for portable signs. <br />9. The Output Cable is Listed, Power-Limited Circuit Cable (QPTZ), type PLTC, marked "sunlight resistant" or "sun res", 'WET" or <br />'WET LOCATION" 3 conductor, -40°C. <br />10.The minimum thickness of the aluminum of the housing of the drivers is 0.91 mm. This is in compliance with the minimum <br />required thickness that is specified in Table 6.1 of UL8750 standard for nonferrous sheet metal. <br />Power Supply with Class 2 output, models L24V100UNV-Q, and D24V1 OOUNV-Q. <br />1. The drivers shall be installed in compliance with the applicable requirements of the end-product standard for, mounting, spacing, <br />casualty and segregation. <br />2. The maximum available output parameters were within the maximum allowable limits for Class 2, inherently limited as specified <br />in the UL 1310, Standard for Class 2 Power Units for wet location and also in accordance with the Canadian Safety Standard <br />CSA C22.2 No. 223. <br />3. The drivers were tested for a maximum manufacturers recommended Tc location, should not exceed 67°C, in ambient of 40°C. <br />If adjacent LED power supplies are spaced closer than 1 in. end to end or 4 in. side to side a temperature test shall be <br />conducted in the end use product. <br />4. The drivers are suitable for use in "DRY", "DAMP", and 'WET" locations. <br />5. In the end product, spacings between transformers, ballast, nea power supplies, and LED power supplies shall be at least 25.4 <br />mm (1 in.) from end to end and 101.6 mm (4 in.) from side to side. Minimum 25.4 (1 in.) spacing between thermoplastic, wood, <br />fiber or other combustible material and enclosed LED power supply when only one LED power supply is provided; and minimum <br />12.7 mm (0.50 in.) between thermoplastic, wood, fiber, or other combustible material and unenclosed LED power supply. <br />6. The input and output leads were not subjected to the strain relief test. However, the drivers are potted and the need to perform <br />the Strain Relief and/or Pushback Relief Tests on the lead wires should be determined in the end-use application. <br />7. The primary (BlackAA/hite/GREEN) and the output (Red-Black) connection wires of the power supply are R/C (AVLVBAVLV8), <br />18 AWG, 90°C. The suitability of the leads shall be determined in the end-use application. <br />8. The leakage current test was performed in accordance with the UI 1310 standard while the driver was connected to a 120 V and <br />also while connected to a 240 V source of supply and the maximum measured leakage current was 0.50 mA. Therefore, a <br />maximum of one LED Driver can be used for portable signs. <br />9. The Output Cable is Listed, Power-Limited Circuit Cable (QPTZ), type PLTC, marked "sunlight resistant" or "sun res", "WET" or <br />"WET LOCATION", 3 conductor, -40 °C. <br />10. The minimum thickness of the aluminum of the housing of the drivers is 0.91 mm. This is in compliance with the minimum <br />required thickness that is specified in Table 6.1 of UL8750 standard for nonferrous sheet metal. <br />11. The "IP67" has not been evaluated by UL and should be considered in the end-use application. <br />VENTEX TECHNOLOGY INC E319052 <br />1201 JUPITER PARK DR <br />JUPITER, FL 33458 <br />LED Lighting System, VenBrite, Consisting of Models VL-R100, VI--CW100, VL-W100, VL-x100, VL-xlOON, VL-x100SC, VL-x200 <br />Single LED Modules and Models VLP100-120, VLP100-277, VLP200-120, VLP200-277 LED Drivers. Provided with Low-Voltage <br />LED Wire Cat. Nos. VA-V\/09, VA-W02, VA-WOO and Wire Connector Part No VA-WN01, where x represents the color of the <br />LEDs (W, CW, \AM/, R, B, G, A, RO or any alphanumeric character). 1. The VL-x100 and VL-nl OONS LED modules have been <br />.