Laserfiche WebLink
PHOTOVOLTAIC REQUIREMENTS <br />PER CALIFORNIA ELECTRICAL CODE ARTICLE 690 <br />PV SYSTEM AC DISCONNECT <br />RATED AC OUTPUT CURRENT - AMPS <br />AC NORMAL OPERATING VOLTAGE 240 VOLTS <br />WARNING <br />DO NOT TOUCH TERMINALS ON BOTH <br />LINE AND LOAD SIDES MAY BE <br />ENERGIZED IN THE OPEN POSITION <br />113 <br />WARNING <br />ELECTRIC SHOCK HAZARD. <br />IF GROUND FAULT IS INDICATED . -OC <br />NORMALLY GROUNDED *gE <br />CONDUCTORS MAY BE U. 6 95 <br />UNGROUNDED AND ENERGIZED DEck zgo*- @ <br />MAIN SERVICE <br />SERVICE METER0 -01METERDISCONNECT|SOCKET <br />0 09 <br />WARNING <br />DUAL POWER SOURCES SECOND SOURCE IS <br />PHOTOVOLTAIC SYSTEM <br />RATED AC OUTPUT CURRENT 28 AMPS <br />AC NORMAL OPERATING VOLTAGE 240 VOLTS <br />WARNING <br />INVERTER OUTPUT CONNECTION. DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE <br />This label is to be located adjacent to the PV breaker <br />AC <br />0 DC <br />L E <br />Q. U.1 <br />Smart En <br />9 (C-46) <br />UC. # <br />Date <br />Revision/Issue <br />No. <br />1 tz@ 8 <br />OFCA - DC CONDUIT (EVERY 10)225NTERIOREXTERIOR0 M COWARNING0 N 5DO NOT TOUCH TERMINALS ON BOTH 2 0 <br />LINE AND LOAD SIDES MAY BE CAUTION: SOLAR CIRCUIT O <br />- ENERGIZED IN THE OPEN POSITION * COMBINER / 111 <br />INVERTER JUNCTION ARRAY - <br />C 3 Box <br />ON g <br />DISCONNECT _ <br />e - <br />DC DISCONNECT <br />| -| OFF <br />PV SYSTEM DC DISCONNECT <br />RATED MAX POWER POINT CURRENT - 8.29 AMPS <br />RATED MAX POWER POINTVOLTAGE - 422.8 VOLTS <&! No. C58724MAXIMUM SYSTEM VOLTAGE - 595.30 VOLTS <br />SHORT CIRCUIT CURRENT - 13.79 AMPS \*< Exp. 3-31-15 <br /> CAL 5 <C <br />36" to 75" above the floor or grade <br />level to center of performance meters <br />(IF APPLICABLE) <br />1 NOTE: If the Photovoltaic Disconnect is remote and not within <br />sight from the Main Service Disconnect, then a directory <br />showing the locations of the Main Service Disconnect and the <br />Photovoltaic Disconnect must be installed at the Main Service Panel <br />location. (SEE SAMPLE DIRECTORY IF APPLICABLE) <br />Recommended signage or labeling specifications . <br />A, Red background with white lettering <br />B. 3/8" letter height <br />C. All capital letters , <br />D. Arial or similar font f <br />E. Weather resistant material (i.e engraved plastic) <br />F. Reflective <br />www. Loyd W Martin .com <br />Solar Structures Engineering <br />#2014-313 Structural Only <br />Project PEOU <br />Sheet <br />Date 02/26/2014 <br />Scale As Noted PV5 <br />31 <br />170. <br />Drawn <br />By DA