Laserfiche WebLink
SCOPE OF WORK GENERAL NOTES <br />PAGE # DESCRIPTION <br />PV-1.0 COVER SHEET <br />PV-2.0 SITE PLAN <br />PV-3.0 LAYOUT <br />PV-3.1 MOUNTING DETAIL <br />PV-4.0 ELECTRICAL <br />PV-4.1 ELECTRICAL CONT. <br />PV-4.2 ELECTRICAL CALCS <br />PV-4.3 PANEL SCHEDULE <br />PV-5.0 SIGNAGE <br />PV-5.0 SIGNAGE 2 <br />VICINITY MAPABBREVIATIONS <br />A AMPERE <br />AC ALTERNATING CURRENT <br />AFC ARC FAULT CIRCUIT INTERUPTER <br />AZIM AZIMUTH <br />COMP COMPOSITION <br />DC DIRECT CURRENT <br />(E)EXISTING <br />ESS ENERGY STORAGE SYSTEM <br />MSP MAIN SERVICE PANEL <br />(N)NEW <br />PRE-FAB PRE-FABRICATED <br />PSF POUNDS PER SQUARE FOOT <br />PV PHOTOVOLTAIC <br />RSD RAPID SHUTDOWN DEVICE <br />TL TRANSFORMERLESS <br />V VOLTS <br />W WATTS <br />SHEET INDEX <br />PAGE <br />REV: A 11/5/2025 <br />ANNICE LIN <br />1852 W MEADOWBROOK DR, <br />SANTA ANA, CA, 92704 <br />PROJECT NUMBER: <br /> 109R-852LIN PR-3004558128 <br />SHEET <br />DESIGNER: <br />MAITENDRA SINGH <br />CUSTOMER RESIDENCE: <br />TEL. (714) 319-3666 <br />APN: 412-531-40 <br />(415) 580-6920 ex3 <br />PV-1.0 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />COVER SHEETREV NAME DATE COMMENTS <br />• ALL WORK SHALL GENERALLY CONFORM WITH 2022 CRC/CBC/CEBC, 7-16 ASCE & 2018 NDS, MUNICIPAL CODE, AND <br />ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. <br />• PHOTOVOLTAIC SYSTEM WILL COMPLY WITH CEC 2022. <br />• ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH CEC 2022. <br />• PHOTOVOLATIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM <br />COMPLIES WITH 690.41(A) <br />• MODULES CONFORM TO AND ARE LISTED UNDER UL 61730. <br />• INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. <br />• RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. <br />• SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. <br />• RAPID SHUTDOWN SYSTEM IN COMPLIANCE WITH CEC 2022 690.12(B)(1) WHERE CONDUCTORS OUTSIDE OF THE <br />ARRAY ARE LIMITED TO LESS THAN 30V IN 30 SECONDS AND CEC 2022 690.12(B)(2)(2) WHERE CONDUCTORS INSIDE <br />THE ARRAY BOUNDARY IS LIMITED TO LESS THAN 80V IN 30 SECONDS <br />• CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(D). <br />• ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. <br />• 14.29 AMPS MODULE SHORT CIRCUIT CURRENT. <br />• 22.33 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a)(1) & 690.8 (b)]. <br />• ENERGY STORAGE SYSTEM CONFORMS TO AND IS LISTED UNDER UL 9540. <br /> • ENERGY STORAGE SYSTEM LIVE PARTS ARE NOT ACCESSIBLE DURING ROUTINE MAINTENANCE. SYSTEM <br />VOLTAGE IN ACCORDANCE WITH CEC 706.20 AND EXCEPTION 1 CEC 706.20 (B). <br /> • ADDITIONAL DISCONNECTING MEANS SHALL BE INSTALLED WHERE THE CIRCUITS FROM THESE TERMINALS PASS <br />THROUGH A WALL OR PARTITION PER 706.15(D). <br /> • LISTED, COMBINATION TYPE AFCI SHALL BE INSTALLED WHERE BACKED UP CIRCUIT WIRING IS EXTENDED MORE <br />THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER CEC 210.12(D). <br />• ALL PASS-THROUGH CONDUCTORS MUST COMPLY WITH CEC 312.8 <br />• THE CAPACITY OF THE STANDALONE SYSTEM SUPPLY SHALL BE EQUAL TO OR GREATER THAN THE LOAD POSED <br />BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER CEC ARTICLE 710.15(A) <br />• SYSTEM SIZE: 18.92KW DC, 34.5KW AC <br />• MODULES: (43) SILFAB: SIL-440QD-DCA <br />• RAPID SHUTDOWN: (16) TESLA MID CIRCUIT INTERRUPTER <br />(MCI) ROOFTOP MODULE LEVEL RAPID SHUTDOWN DEVICE <br />• ENERGY STORAGE SYSTEM W/ INTEGRATED PV INVERTER: <br />(3) TESLA: POWERWALL 3 1707000-XX-Y, 13.5KWH, 11.5KW <br />INVERTER OUTPUT, LITHIUM-ION BATTERY (WEIGHT: 291.2 LB <br />EACH) <br />(1) EXPANSION PACK 1807000-XX-Y (WEIGHT: 261.2 LB EACH) <br />TOTAL ENERGY CAPACITY: (IN kWh): 54.0 kWh <br />• RACKING: ULTRAFOOT RAIL TO FRAMING SNR-DC-01507 <br />• POWER-CONTROLLED SYSTEM (PCS) ENABLED EQUIPMENT <br />INSTALLED, SEE PV-4.0 FOR INTERCONNECTION DETAILS <br />MAIN BREAKER DE-RATED FOR SOLAR <br />BACKFEED MAX 200A MAIN BREAKER <br />ALLOWED