/ce/ <br />DESIGN CRITERIA <br />MAX DISTRIBUTED LOAD: 3 PSF <br />SNOW LOAD: 0 PSF <br />WIND SPEED: <br />96 MPH 3-SEC GUST.FASTENERS: <br />(1) 5/16" DIA S.S. LAG SCREW: 2.5" <br />MIN EMBEDMENT INTO FRAMING <br />PAGE <br />REV: A 11/5/2025 <br />ANNICE LIN <br />1852 W MEADOWBROOK DR, <br />SANTA ANA, CA, 92704 <br />PROJECT NUMBER: <br /> 109R-852LIN PR-3004558128 <br />SHEET <br />DESIGNER: <br />MAITENDRA SINGH <br />CUSTOMER RESIDENCE: <br />TEL. (714) 319-3666 <br />APN: 412-531-40 <br />(415) 580-6920 ex3 <br />PV-3.0 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />LAYOUT <br />D1 - AR-01 - SCALE: 1/8" = 1'-0" <br />AZIM: 360° <br />PITCH:30° <br />D2 - AR-02 - SCALE: 1/8" = 1'-0" <br />AZIM:180° <br />PITCH:30° <br />4" <br />SOLAR MODULE <br />SNAPNRACK <br />RACKING <br />MODULE ELEVATION DETAIL - SCALE: NTS <br />ROOF INFO ATTACHMENT INFORMATION <br />Name Type Height Detail Max Landscape <br />OC Spacing <br />Max Landscape <br />Overhang <br />Max Portrait <br />OC Spacing <br />Max Portrait <br />Overhang Configuration <br />AR-01 COMP SHINGLE - UR - ULTRAFOOT 2-Story ULTRAFOOT RAIL TO FRAMING SNR-DC-01507 6'-0"2'-4"6'-0" 2'-3"STAGGERED <br />AR-02 COMP SHINGLE - UR - ULTRAFOOT 2-Story ULTRAFOOT RAIL TO FRAMING SNR-DC-01507 6'-0" 2'-4" 6'-0" 2'-3" STAGGERED <br />INSTALLERS SHALL NOTIFY ENGINEER OF ANY <br />POTENTIAL STRUCTURAL ISSUES OBSERVED <br />PRIOR TO PROCEEDING W/ INSTALLATION. <br />ATTACHMENTS FOR THIS INSTALLATION ARE DESIGNED FOR A STANDARD <br />WOOD FRAMED ROOF STRUCTURE FREE FROM DAMAGE, DETERIORATION, <br />OR MODIFICATION THAT WOULD COMPROMISE ITS ORIGINAL DESIGN <br />INTEGRITY. INSTALLERS SHALL OBSERVE THE FRAMING FOR <br />CONFORMANCE TO THE BELOW REQUIREMENTS AND NOTIFY THE ENGINEER <br />OF ANY POTENTIAL STRUCTURAL ISSUES FOR GUIDANCE PRIOR TO <br />PROCEEDING WITH INSTALLATION. <br />ⅰ: MINIMUM 2x WOOD FRAMING (NOMINAL) FREE FROM DAMAGE, <br />DETERIORATION, OR MODIFICATION <br />ⅱ: FRAMING SPACING AT 24"" O.C. MAX <br />ⅲ: FASTENER SHALL BE EMBEDED INTO COMPETENT MATERIAL <br />• IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" (48" FOR TILT KITS) BOUNDARY <br />REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), <br />THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN <br />THE 12" (48" FOR TILT KITS) BOUNDARY REGION ONLY AS <br />FOLLOWS: <br />•• ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE <br />REDUCED BY 50%. <br />•• ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF <br />ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. <br />(E) CHIMNEY <br />33'-11" <br />22'-9" <br />11'-4" <br />22'-7" <br />9'-8"3'-11" <br />1'-2" <br />1'-7" <br />10" <br />3'-4" <br />10'-5" <br />11'-3"21'-4"11'-3" <br />12'-4" <br />8"3'-1" <br />1'-7" <br />8'-11" <br />1'-9" <br />12'-3" <br />Exp. 12/31/2026Digitally Signed On: 11/05/25