ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES <br />C\CM'acn»•ti'v,c„,gW'AdEPT- 11;9(3*AMMEM <br />A AMPERE <br />AC ALTERNATING CURRENT <br />BLDG BUILDING <br />CONC CONCRETE <br />DC DIRECT CURRENT <br />EGC EQUIPMENT GROUNDING CONDUCTOR <br />(ID EXISTING <br />EMT ELECTRICAL METALLIC TUBING <br />GALV GALVANIZED <br />GEC GROUNDING ELECTRODE CONDUCTOR <br />GND GROUND <br />HDG HOT DIPPED GALVANIZED <br />1 CURRENT <br />Imp CURRENT AT MAX POWER <br />Isc SHORT CIRCUIT CURRENT <br />kVA KILOVOLT AMPERE <br />kW KILOWATT <br />LBW LOAD BEARING WALL <br />MIN MINIMUM <br />(N) NEW <br />NEUT NEUTRAL <br />NTS NOT TO SCALE <br />OC ON CENTER <br />PL PROPERTY UNE <br />Pol POINT OF INTERCONNECTION <br />PV PHOTOVOLTAIC <br />SCH SCHEDULE <br />SS STAINLESS STEEL <br />STC STANDARD TESTING CONDITIONS <br />TYP TYPICAL <br />UPS UNINTERRUPTIBLE POWER SUPPLY <br />V VOLT <br />Vmp VOLTAGE AT MAX POWER <br />' Voc VOLTAGE AT OPEN CIRCUIT <br />W WAIT <br />jR NEMA 3R, RAINTIGHT <br />LICENSE <br />CA # 888104 <br />C-46, C-10 <br />MODULE GROUNDING METHOD: SLEEKMOUNT <br />AHJ: Sonta Ana <br />UTILITY: Southern California Edison (SCE) <br />1. WHERE ALL TERMINALS OF THE DISCONNECTING <br />MEANS MAY BE ENERGIZED IN THE OPEN POSITION, <br />A SIGN WILL BE PROVIDED WARNING OF THE <br />HAZARDS PER ART. 690.17. <br />2. EACH UNGROUNDED CONDUCTOR OF THE <br />MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY <br />PHASE AND SYSTEM PER ART. 210.5. <br />3. A NATIONALLY-RECOGNIZED TESTING <br />LABORATORY SHALL LIST ALL EQUIPMENT IN <br />COMPLIANCE WITH ART. 110.3. <br />4. CIRCUITS OVER 250V TO GROUND SHALL <br />COMPLY WITH ART. 250.97, 250.92(B) <br />5. DC CONDUCTORS EITHER DO NOT ENTER <br />BUILDING OR ARE RUN IN METALLIC RACEWAYS OR <br />ENCLOSURES TO THE FIRST ACCESSIBLE DC <br />DISCONNECTING MEANS PER ART. 690.31(E). <br />6. ALL WIRES SHALL BE PROVIDED WITH STRAIN <br />RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY <br />UL LISTING. <br />7. MODULE FRAMES SHALL BE GROUNDED AT THE <br />UL-LISTED LOCATION PROVIDED BY THE <br />MANUFACTURER USING UL LISTED GROUNDING <br />HARDWARE. <br />8. MODULE FRAMES, RAIL, AND POSTS SHALL BE <br />BONDED WITH EQUIPMENT GROUND CONDUCTORS AND <br />GROUNDED AT THE MAIN ELECTRIC PANEL. <br />9. THE DC GROUNDING ELECTRODE CONDUCTOR <br />SHALL BE SIZED ACCORDING TO ART. 250.166(B) & <br />690.47. <br />GENERAL NOTES <br />1. THIS SYSTEM IS GRID-INTERTIED VIA A <br />UL-LISTED POWER-CONDITIONING INVERTER. <br />2. THIS SYSTEM HAS NO BATTERIES, NO UPS. <br />3. SOLAR MOUNTING FRAMES ARE TO BE <br />GROUNDED. <br />4. ALL WORK TO BE DONE TO THE 2013 <br />CALIFORNIA BUILDING CODE. <br />5. ALL ELECTRICAL WORK SHALL COMPLY WITH <br />THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY <br />THE 2013 CALIFORNIA ELECTRIC CODE. <br />iEDECEI9 <br />MAR 1 0 2014 <br />City of Santa Ana <br />VICINITY MAP <br />t.2 <br />APPROVED <br />PLANNING DIVISION <br />bASTER I.D.1,0 1 4- 0 301 6 <br />G.P.LA zone 2 1 <br />PLANNER /70-71 -DATE 3-4 - 14 <br />TRANSFERRED BY DATE <br />F'LANNING ;NGFECTION REQUIRED: .-- <br />2.OUGH FINAL NONE - <br />i.:AME (714) . <br />RETA:N PLAR·'t '· 3t EUTURE REVISIONS. <br />UBJECT 1-0 : - ?.C:HECKED AN -2-ELOUY: <br />O INTER·..1 . ' Y <br />O NO O.,V. 1 U......CE,23.7;DNS:% <br />O ALL j.'·.1 '2-'H:.ril--FL; MATCH EX <br />O SCREENING RECU?RED <br />CL: SUE-,£11' 1.ANDSCAFE PLANS <br />-LECTR?CAL, PLUMBI (G & AE¢Dal'ARATE PERMI TS A RI <br />2.4-- - 417 GL ast of plans and specl icationa mu<'! times and it i• a,ni iwfliPW rm <br />INDE*Santa Ana,' lions on same withe i,t vr; 1 <br />PV1 COVER SHEET : <br />PV2 SITE PLAN held to permit nor be an approval o <br />PV4 THREE LINE DIAGRAM <br />Cutsheets Attached , <br />CC , OF SANTA AW <br />\- <br />REV BY DATE COMME*rS <br />REV A NAME 11/U2013 COMMENTS Chj <br />ARCH <br />1|)DIFICAceep'tING <br />CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER JB-927442 00 PREMISE OWNER:DESCRIPnON:DESIGN: <br />CONTAINED SHALL NOT BE USED FOR THE DUMAUAL, ERICKSON DUMAUAL RESIDENCE Brian Reole <br />BENEFIT OF ANYONE EXCEPT SOLARCITY INC..MOUNnNG SYSTDI: <br />NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C with Lifter 2526 W MANLY AVE 3.75 KW PV Array <br />PART TO OTHERS OUTSIDE THE REaPIENTS SANTA ANA, CA 92704ORGANIZATION, EXCEPT IN CONNECnON WITH MODULES: <br />THE SALE AND USE OF THE RESPECTIVE (15) TRINA SOLAR # TSM-250PA05.18 9ET:REV: DATE: <br />SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: <br />PAGE NAkE <br />PERMISSION OF SOLARCITY INC POWER-ONE # AURORA PVI-3.0-OUTD-S-US (714) 348-0782 COVER SHEET PV 1 11/2/2013