Laserfiche WebLink
CITY OF SANTA ANA <br />Planning and Building Agency <br />ES <br />ICC-ES Evaluation Report ESR-1118 F <br />RE <br />This report is subject to rE <br />Supplement <br />ued January 2025 <br />Aa efalliary 2027. <br />www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the lnternatyonal Code Council° <br />DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES <br />Section: 06 17 53—Shop-Fabricated Wood Trusses <br />REPORT HOLDER: <br />ITW BUILDING COMPONENTS GROUP INC. <br />EVALUATION SUBJECT: <br />ALPINE TRUSS PLATES (METAL CONNECTOR PLATES): WAVE, H AND SS, TRULOX AND HINGE PLATES <br />1.0 REPORT PURPOSE AND SCOPE <br />Purpose: <br />The purpose of this evaluation report supplement is to indicate that the Alpine Truss Plates (Metal Connector Plates), <br />described in ICC-ES evaluation report ESR-1118, have also been evaluated for compliance with the codes noted below. <br />Applicable code editions: <br />■ 2023 Florida Building Code —Building <br />■ 2023 Florida Building Code —Residential <br />2.0 CONCLUSIONS <br />The the Alpine Truss Plates (Metal Connector Plates), described in Sections 2.0 through 7.0 of the evaluation report <br />ESR-1118, comply with the Florida Building Code —Building and the Florida Building Code —Residential. The design <br />requirements must be determined in accordance with the Florida Building Code —Building or the Florida Building <br />Code —Residential, as applicable. The installation requirements noted in ICC-ES evaluation report ESR-1118 for the 2021 <br />International Building Code® meet the requirements of the Florida Building Code —Building or the Florida Building <br />Code —Residential, as applicable, with the following condition: <br />a) Compliance with Section 2304.10.5 of the Florida Building Code —Building and Section R317.3 of the Florida Building <br />Code —Residential is required. Alternatively, connectors must be protected as described in Section 5.7 of the evaluation <br />report ESR-1118. <br />Use of the the Alpine Truss Plates (Metal Connector Plates) has also been found to be in compliance with the High -Velocity <br />Hurricane Zone provisions of the Florida Building Code —Building and the Florida Building Code —Residential with the following <br />condition: <br />a) For connections subject to uplift in accordance with FBC Section 2321, the connection must be designed for no less <br />than 700 pounds (3114 N). <br />For products falling under Florida Rule 61 G20-3, verification that the report holder's quality assurance program is audited by <br />a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the <br />responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the <br />Commission). <br />This supplement expires concurrently with the evaluation report ESR-1118, reissued January 2025. <br />ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed nor are they to be construed �� d <br />as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as �o ANrA6 <br />to arty finding or other matter in this report, or as to any product covered by the report <br />d <br />JANCE <br />Copyright © 2025 ICC Evaluation Service, LLC. All rights reserved. Page 10 of 10 <br />