E100 <br />MINIMUM <br />MOUNTED <br />MIN <br />MTD <br /> - M - <br />MAIN CIRCUIT BREAKER <br /> - K - <br />KILOWATT <br /> - L - <br />LIGHTING CONTROL PANEL <br />KILOVOLT AMPERE <br />MCB <br />LCP <br />KW <br />KVA <br />VM VOLTMETER <br />WEATHERPROOF <br /> - W - <br />WP <br />W WATT <br /> - U - <br />VOLT AMPERE <br />VOLT OR VOLTAGE <br /> - V - <br />UNLESS OTHERWISE NOTED <br />V <br />VA <br />TYP <br />UON <br />TYPICAL <br />GROUND FAULT INTERRUPTER <br />INSTRUMENT <br />INCANDESCENT <br /> - I - <br />IC <br />GROUND <br />INTERRUPTING CAPACITY <br />JUNCTION BOX <br /> - J - <br />INST <br />INCAND <br />JB <br />SECTION <br />SINGLE POLE <br />GRD <br /> - G - <br />G, GFI, <br />GFCI <br />SECT <br /> - T - <br />TRANSF <br />SPECIFICATION <br />SWITCHBOARD <br />TRANSFORMER <br />TELEVISION <br />TELEPHONE <br />SW <br />SWBD <br />TEL <br />TV <br />SP <br />SPEC <br />SWITCH <br /> - S - <br />SCHEDULESCHED <br />FLUSH WALL MOUNTED JUNCTION BOX <br />TYPE B - UON. <br />COMBINATION MOTOR CONTROLLER AND <br />UNFUSED DISCONNECT SWITCH- <br />MOTOR RATED TOGGLE SWITCH +44" TYP. <br />TRANSFORMER <br />MOTOR <br />3/4" CONDUIT WITH 4#12+1#12EG., U.O.N. <br />1/2" CONDUIT WITH 3#12+1#12EG., U.O.N. <br />1/2" CONDUIT WITH 2#12+1#12EG., U.O.N. <br />FLUSH MOUNTED PANELBOARD <br />SURFACE MOUNTED PANELBOARD <br />CONDUIT HOMERUN 3/4"C MIN. (U.N.O.) <br />GROUND CONNECTION <br />CEILING MOUNTED JUNCTION BOX. <br />CIRCUIT BREAKER-100 AMP FRAME/100AMP <br />TRIP, 3 POLE UON <br />POWER TRANSFORMER, DISTRIBUTION <br />GROUND FAULT RELAY <br />CONCEALED CONDUIT <br />FLUSH WALL MONTED DUPLEX CONVENIENCE <br />RECEPTACLE AT +15" TO BOTTOM OF OUTLET. <br />FLUSH WALL MONTED QUADRUPLEX CONVENIENCE <br />RECEPTACLE AT +15" TO BOTTOM OF OUTLET. <br />EXISTING TO REMAIN <br />(N) <br />(E) <br />INDICATES NEW <br />INDICATES "GROUND FAULT INTERRUPT" <br />INDICATES "SEPARATE 20 AMP. CIRCUIT" <br />INDICATES 24-HR NIGHT LIGHT WITH 90 MIN. BACK-UP BATTERY <br />FUSE, UNFUSED EXCEPT WHERE FUSE SIZE IS <br />DISCONNECT SWITCH-100A SWITCH, 60A <br />INDICATED 3 POLE EXCEPT WHERE NOTED <br />LTG <br />CABINET <br />LIGHTING <br />CONT <br />CLOS <br />CLG <br />CLOSET <br />CB <br />CIRCUIT <br />ABOVE FINISHED FLOOR <br />C <br />INDICATES RELOCATED <br /> - B - <br />(R) <br />CAB <br />ALUMINUM <br />A <br />CURRENT TRANSFORMERCT <br /> - A - <br />CU <br />FT <br />COMM <br />FL <br />FEET OR FOOT <br />CKT <br />CAT <br />CONTINUATION <br />FDR <br />FIXT <br />COMMUNICATION <br />COPPER <br />EMER <br />CIRCUIT BREAKER <br />ELEC <br />CATALOG <br />CEILING <br />FUSE <br />FIXTURE <br />AMERICAN WIRE GAUGE <br />AFF <br />BLDG. <br />EQUIPMENT <br />AL <br />ELEVATION <br />AWG <br />DIAMETER <br />AH <br />BUILDING <br />EG <br />CONDUIT <br /> - C - <br />DN <br />AMPERE-HOUR <br />DIST <br /> - E - <br />DISC <br />AMPERE <br />EQUIPMENT GROUND <br />ELECTRICAL CLOSET <br />FLOOR <br />EACH <br />DISCONNECT <br />DISTRIBUTION <br />EXIST, (E) <br />DOWN <br />DRAWING <br />F <br />EL <br />DEGREE <br />ROOM <br /> - D - <br />EQUIP <br />REQUIRED <br /> - F - <br />RECEPTACLERECEPT <br />FEEDER <br />REQD <br />RM <br />EMERGENCY <br />ELECTRICAL <br />OWNER FURNISH AND <br />POLE <br />EXISTING <br />DIA <br />POWER <br />PANEL <br />EA <br />EC <br />PNL <br />DWG PWR <br />Ø, PH <br />PB <br />P <br />OFOI <br />NORMALLY CLOSEDNC <br />NORMALLY OPEN <br />NON-FUSED <br />NOT IN CONTRACT <br /> - O - <br />DEG <br />OUTSIDE DIAMETER <br />NOT TO SCALE <br />ON CENTER <br />OD <br />NTS <br />OC <br />NIC <br />NO <br /> - R - <br />NF <br />OWNER INSTALL <br />NEUTRAL <br /> - N - <br /> - P - <br />PULL BOX <br />NL <br />N <br />NIGHT LIGHT <br />PHASE <br />DEVICE MOUNTING HEIGHT <br />SCALE: <br />NONE 1 <br />1. PROVIDE ALL LABOR, MATERIALS, INSURANCE, EQUIPMENT, INSTALLATION, <br />CONSTRUCTION TOOLS, TRANSPORTATION, ETC. FOR A COMPLETE AND PROPERLY <br />OPERATING ELECTRICAL SYSTEM. <br />2. CONSTRUCTION TERMINOLOGY, AND THE STANDARDS AND ACCEPTABLE METHODS OF <br />INSTALLATION REQUIRED BY THESE CONTRACT DOCUMENTS ARE BASED ON PUBLISHED <br />STANDARDS OF N.E.C.A. (NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION), NATIONAL <br />ELECTRICAL SAFETY CODE, AMERICAN NATIONAL STANDARDS INSTITUTE DOCUMENTS, <br />NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION, UNDERWRITERS LABORATORIES, <br />AND THE CALIFORNIA ELECTRICAL CODE. SUBMITTAL OF BID INDICATES THE CONTRACTOR <br />IS COGNIZANT OF THESE STANDARDS AND THE REQUIREMENTS NECESSARY TO PERFORM <br />ALL THE WORK AS SET FORTH IN THESE CONTRACT DOCUMENTS. <br />3. SECURE ALL NECESSARY ELECTRICAL PERMITS, UTILITY CHARGES AND PAY FOR SAME. <br />COORDINATE AND PAY FOR ALL TEMPORARY ELECTRICAL SERVICE, CHARGES WITH THE <br />SERVING UTILITY, AND OWNER. COORDINATE TEMPORARY CONSTRUCTION <br />REQUIREMENTS WITH ALL TRADES PRIOR TO CONSTRUCTION. <br />4. THESE PLANS ARE DIAGRAMMATIC ONLY, FOLLOW AS CLOSELY AS POSSIBLE AND REFER <br />TO ARCHITECTURAL DRAWINGS FOR DETAILS, EXACT EQUIPMENT AND OUTLETS <br />LOCATIONS. ALTHOUGH NOT SHOWN, CONTRACTOR SHALL PROVIDE ALL J-BOXES, <br />PULL-BOXES, ELLS, OFFSETS, ETC., FOR COMPLETE CODE APPROVED INSTALLATION. <br />FOOTAGE SHOWN ON ELECTRICAL SINGLE LINES AND RISER DIAGRAMS ARE FOR <br />CALCULATION PURPOSES ONLY AND ARE NOT FOR BIDDING PURPOSES OR MATERIAL <br />TAKEOFF. ALL LOCATIONS OF EVERY EQUIPMENT, DEVICES, OUTLETS, ETC. SHALL BE <br />VERIFIED PRIOR TO ROUGH-IN. <br />5. THE CONNECTION METHOD SHOWN IS FOR BIDDING PURPOSES. THE CONTRACTOR SHALL <br />COORDINATE AND PROVIDE FROM ACTUAL BUILDING SHOP DRAWING, THE CONNECTION <br />SHOWN ON THOSE DRAWINGS. <br />6. ALL MATERIALS SHALL BE NEW (U.O.N.) AND OF THE SAME MANUFACTURER FOR EACH <br />CLASS OF GROUP OF EQUIPMENT. MATERIALS SHALL BE LISTED AND APPROVED BY <br />UNDERWRITER'S LABORATORIES FOR THE USE AND ENVIRONMENT, AND SHALL BEAR THE <br />INSPECTION LABEL WHERE SUBJECT TO SUCH APPROVAL. MATERIALS SHALL MEET WITH <br />THE APPROVAL OF THE DIVISION OF INDUSTRIAL SAFETY, AND ALL GOVERNING BODIES <br />HAVING JURISDICTION. MATERIALS SHALL BE MANUFACTURED IN ACCORDANCE WITH <br />APPLICABLE STANDARDS ESTABLISHED BY A.N.S.I., U.L., AND N.E.M.A. INSTALL PER <br />MANUFACTURERS' RECOMMENDATIONS. ALL EXTERIOR EQUIPMENT SHALL BE <br />WEATHERPROOF. <br />7. ALL CONDUITS SHALL BE CONCEALED WHERE PHYSICALLY POSSIBLE CONNECTIONS <br />SHALL BE COMPRESSION TYPE ONLY. <br />8. CONTRACTOR SHALL PERFORM HIS WORK IN ACCORDANCE WITH ALL GOVERNING STATE, <br />COUNTY, LOCAL CODES, O.S.H.A. AND THE PRESENTLY ADOPTED CALIFORNIA ELECTRICAL <br />CODE (2022 CEC) . ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND <br />WORKMANLIKE MANNER (CEC 2022 SECTION110.12) <br />9. THE COMPLETE ELECTRICAL SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH THE <br />PRESENTLY ADOPTED EDITION OF THE C.E.C. ARTICLE #250, AND SHOWN ON THE <br />DRAWINGS. AT THE REQUEST OF AND IN THE PRESENCE OF THE AUTHORIZED INSPECTOR, <br />THE CONTRACTOR SHALL PROVIDE SYSTEM RESISTANCE READINGS. <br />10. UNLESS NOTES OTHERWISE, CONDUCTORS SHALL BE CODE GRADE, 600 VOLT CLASS, <br />MARKED 24" ALONG IT'S LENGTH SHOWING MANUFACTURER'S NAME, MAXIMUM <br />ALLOWABLE VOLTAGE AND SIZE. CONDUCTORS SHALL BE COPPER TYPE "THWN" (WET) OR <br />"THHN" (DRY). DELIVER THE WIRE TO THE SITE IN UNBROKEN PACKAGES. ALUMINUM <br />CONDUCTORS ARE NOT ALLOWED. <br />11. ALL CONDUIT ONLY (C.O.) SHALL INCLUDE A PULL WIRE. <br />12. ALL FEEDER AND BRANCH HOMERUNS GREATER THAN 100' SHALL BE INCREASED IN SIZE <br />AS REQUIRED TO COMPENSATE FOR VOLTAGE DROP. VOLTAGE DROP SHALL NOT EXCEED <br />3%. <br />13. PROVIDE TYPEWRITTEN PANEL SCHEDULES ON NEW AND REVISED PANELBOARDS. <br />14. RE-USE EXISTING CIRCUIT BREAKERS IN PANELS. PROVIDE NEW AS REQUIRED BY <br />SCHEDULES. <br />15. IDENTIFICATION NAMEPLATES SHALL BE MICARTA 1/8 INCH THICK AND OF APPROVED <br />SIZE WITH BEVELED EDGES AND ENGRAVED WHITE LETTERS A MINIMUM OF 1/4 INCH <br />HIGH ON BLACK BACKGROUND. NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN <br />THE SERVICE DISTRIBUTION AND POWER DISTRIBUTION SWITCHBOARDS OR <br />PANELBOARDS, CENTERS, LIGHTING DISTRIBUTION PANELBOARDS, DISCONNECT <br />SWITCHES, TRANSFORMERS, TERMINAL CABINETS, ETC. ALL NAMEPLATES SHALL BE <br />ATTACHED WITH SCREWS. PULL BOXES, JUNCTION BOXES AND DEVICE BOXES SHALL BE <br />MARKED WITH A PERMANENT MARKER. <br />16. MAXIMUM NUMBER OF CONDUCTORS IN OUTLET OR JUNCTION BOXES SHALL CONFORM <br />TO THE CALIFORNIA ELECTRICAL CODE ARTICLE 314.16. <br />17. WHENEVER A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT, WIRE, EQUIPMENT <br />DEVICES, CIRCUIT BREAKERS, GROUND FAULT PROTECTION SYSTEMS, ETC. (ALL <br />MATERIALS), ARISES ON THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL <br />BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES <br />REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE <br />SPECIFICATIONS TO ENSURE COMPLETE AND OPERABLE SYSTEMS AS REQUIRED BY THE <br />OWNER AND ARCHITECT/ENGINEER. EXACT METHOD AND LOCATION OF CONDUIT <br />PENETRATION AND OPENINGS IN CONCRETE WALLS OR FLOORS OR STRUCTURAL STEEL <br />MEMBERS SHALL BE AS DIRECTED BY THE STRUCTURAL ENGINEER. PERFORM CORING, <br />SAWCUTTING, PATCHING, AND REFINISHED OF WALLS AND SURFACES WHEREVER IT IS <br />NECESSARY TO PENETRATE. OPENINGS SHALL BE SEALED IN AN APPROVED METHOD TO <br />MEET THE FIRE RATING OF THE PARTICULAR WALL, FLOOR OR CEILING. <br />18. EXACT METHOD AND LOCATIONS OF CONDUIT PENETRATIONS AND OPENINGS IN <br />CONCRETE WALLS OR FLOORS SHALL BE UL APPROVED. <br />19. THE CONTRACTOR SHALL INSTALL EQUIPMENT GREEN GROUNDING CONDUCTOR SIZED <br />PER CEC TABLE 250.122 IN ALL CONDUITS. <br />20. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES AT THE SITE. <br />ANY COSTS TO INSTALL WORK TO ACCOMPLISH SAID COORDINATION WHICH DIFFERS <br />FROM THE WORK AS SHOWN ON THE DRAWINGS SHALL BE INCURRED BY THE <br />CONTRACTOR. ANY DISCREPANCIES, AMBIGUITIES OR CONFLICTS SHALL BE BROUGHT <br />TO THE ATTENTION OF THE ARCHITECT DURING BID TIME FOR CLARIFICATION. ANY SUCH <br />CONFLICTS NOT CLARIFIED PRIOR TO BID SHALL BE SUBJECT TO THE INTERPRETATION <br />OF THE ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. <br />21. ROUTE EXPOSED CONDUIT AND CONDUIT AT CEILING SPACES PARALLEL AND <br />PERPENDICULAR TO WALLS AND ADJACENT PIPING. ARRANGE CONDUIT TO MAINTAIN <br />HEADROOM AND TO PRESENT A NEAT APPEARANCE. <br />22. ALL FUSE PROTECTION DEVICES OF ALL EQUIPMENT SHALL CONFORM TO THE LISTING <br />OF THE NAMEPLATE RATING OF THE EQUIPMENT. <br />23. ALL EQUIPMENT DISCONNECT SWITCHES AND CONTROLLER LOCATIONS SHALL BE <br />VERIFIED WITH OWNER'S REPRESENTATIVE PRIOR TO ROUGH-IN. <br />24. ALL EQUIPMENT, DEVICES, CONDUIT AND WIRING SHOWN ARE NEW UNLESS OTHERWISE <br />NOTED. <br />25. PROVIDE PANEL CIRCUIT DIRECTORY AND FEEDER SOURCE IDENTIFICATION AT <br />PANELBOARDS PER CEC 408.4. <br />26. EACH CIRCUIT SHALL CONTAIN A DEDICATED NEUTRAL CONDUCTOR. <br />27. CONDUCTORS OF A MULTI-WIRE BRANCH CIRCUIT SHALL ORIGINATE FROM THE SAME <br />PANELBOARD. THE BRANCH CIRCUIT SHALL BE PROVIDED WITH A MEANS THAT WILL <br />SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS AT THE POINT WHERE <br />THE BRANCH CIRCUIT ORIGINATES. <br />TOTAL <br />WATTAGE REMARKVOLTLAMP TYPEDESCRIPTION <br />TYPE <br />FIXTURE MANUFACTURER/ <br />MODEL NUMBERSYMBOLS <br />NOTES: <br />1. ALL LAMPS INCLUDED. <br />33.22x4 LED DLIGHT FIXTURE RECESSED IN <br />T-BAR GRID CEILINGA LEDMVOLT <br />3.7SPEC: (MATCH BUILDING STANDARD) <br />E100 SYMBOL LIST, GENERAL NOTES AND ABBREVIATIONS <br />POWER, AND LIGHTING PLANS <br />E101 <br />E200 <br />SINGLE LINE DIAGRAM AND PANEL SCHEDULES <br />LED EXIT SIGN WITH 90 MINUTES EMERGENCY <br />BATTERY BACK-UP <br />0-10V DIMMING. <br />CONTROL BOX <br />3' <br />- <br />1 <br />0 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />P <br />A <br />R <br />A <br />L <br />L <br />E <br />L <br /> <br />A <br />P <br />P <br />R <br />O <br />A <br />C <br />H <br />2' <br />- <br />1 <br />0 <br />" <br /> <br />M <br />A <br />X <br />. <br />3' <br />- <br />6 <br />" <br />SWITCH, OUTLET, <br />THERMOSTAT,2'-0" <br />MAX. <br />3' <br />- <br />8 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />P <br />E <br />R <br />P <br />E <br />N <br />D <br />I <br />C <br />U <br />L <br />A <br />R <br /> <br />A <br />P <br />P <br />R <br />O <br />A <br />C <br />H <br />TOP OF <br />2022 CBC 11B-308.2.1 <br />2022 CBC 11B-308.3.1 <br />2022 CBC 11B-308.2.2 <br />2022 CBC 11B-308.3.2 <br />SWITCH, OUTLET, <br />THERMOSTAT, <br />TOP OF <br />CONTROL BOX <br />TO BOTTOM <br />15"MIN <br />OF BOX <br />(4 <br />' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />. <br />) <br />LIGHTING NOTES: <br />CONTRACTOR TO INSTALL EXTRA HOT WIRE ALL THE WAY TO THE <br />SOURCE FOR THE UNSWITCHED LEG, WHEREVER A LIGHT FIXTURE <br />EQUIPPED WITH AN EMERGENCY BATTERY OCCURS. <br />THE CONTRACTOR SHALL PROVIDE ALL LOW VOLTAGE CONTROL CABLE <br />AS REQUIRED FOR COMPLETE INSTALLATION AND OPERATION. <br />TELEPHONE AND DATA SYSTEM NOTES: <br />TELEPHONE SYSTEM AND DATA NETWORKING AND CABLING <br />SYSTEM IS AN OWNER FURNISHED SYSTEM. CONTRACTOR <br />TO PROVIDE CONDUIT ONLY WITH PULL CORD. <br />NOTE: <br />SYMBOLS SHOWN ARE NOT <br />NECCESARILY USED FOR <br />THIS PROJECT. <br />SAME AS TYPE "A" EXCEPT WITH 90 MINUTES <br />EMERGENCY BATTERY BACK-UP <br />AE <br />LED277 <br />SPEC: LITHONIA "STAK" <br />#2x4-4000L-80CRI-35K-COL-MIN10-MVOLT <br />(OR SIMILAR TO MATCH EXISTING) <br />ET24 TITLE 24 LIGHTING AND MANDATORY MEASURES <br />Sheet Title <br />Sheet Number <br />Project Number <br />TOWER 1851 <br />1851 E. First <br />St. <br />Santa Ana, Ca. 92705 <br />DGC <br />EXPANSION <br />SUITE 640 <br />TENANT <br />PROJECT <br />REVISIONS <br />DESCRIPTION DATENO. <br />DATE <br />CHECKED <br />DRAWN <br />1316 W. Norwood Street <br />Rialto, CA 92377 <br />Tel. (562) 299-4490 <br />www.jps-electric.com <br />JPS ELECTRIC, INC. <br />These drawings and ideas are not to be <br />reproduced, in whole, or in part, without <br />the express written permission of <br />9/24/2025 <br />XFMR TRANSFORMER <br /> - X - <br />J <br />J <br />WALL MOUNTED COMBINATION TELEPHONE AND DATA <br />DATA OUTLET, 15" TO BOTTOM OF DEVICE CONTRACTOR <br />TO PROVIDE 1"C.O. STUB-UP TO CEILING SPACE. (PROVIDE <br />1"C.O. TO TELEPHONE BACKBOARD AND NETWORK <br />CABINET WHERE EXPOSED CEILING OCCURRED.) <br />WALL MOUNTED TELEPHONE 15" TO BOTTOM OF DEVICE <br />WITH 3/4"C.O STUB-UP TO ACCESSIBLE CEILING SPACE. <br />(PROVIDE 3/4"C.O. TO TELEPHONE BACKBOARD AND <br />NETWORK CABINET WHERE EXPOSED CEILING <br />OCCURRED.)