My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2150 & 2160 E Fourth St - Plumbing & Mechanical Revision - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fourth St
>
2150 E Fourth St
>
2150 & 2160 E Fourth St - Plumbing & Mechanical Revision - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 5:00:14 AM
Creation date
1/15/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
30149660
30149661
40141055
40141056
Full Address
2150 E Fourth St
2160 E Fourth St
Street Number
2160
Street Direction
E
Street Name
Fourth
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
MATERIAL AND FIXTURE SCHEDULES <br />FIXTURE FLOW RATES (2022 CAL GREEN MANDATORY MEASURES) <br />FIXTURE TYPE MAXIMUM FLOW <br />RATE <br />SHOWERHEADS, RESIDENTIAL 1.8 GPM @ 80 PSI <br />WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED <br />FLOW RATE OF ALL SHOWERHEADS AND/OR OTHER SHOWER OUTLETS <br />CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 1.8 GPM AT 80 PSI, OR THE <br />SHOWER SHALL BE DESIGNED TO ALLOW ONLY ONE SHOWER OUTLET TO BE IN <br />OPERATION AT A TIME <br />LAVATORY FAUCETS, RESIDENTIAL 1.2 GPM @ 60 PSI THE MINIMUM FLOW RATE OF RESIDENTIAL LAVATORY FAUCETS SHALL NOT BE <br />LESS THAN 0.8 GPM AT 20 PSI. <br />LAVATORY FAUCETS, PUBLIC AREAS 0.5 GPM @ 60 PSI <br />KITCHEN FAUCETS 1.8 GPM @ 60 PSI <br />KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM <br />RATE, BUT NOT TO EXCEED 2.2 GPM AT 60 PSI, AND MUST DEFAULT TO A MAXIMUM <br />FLOW RATE OF 1.8 GPM AT 60 PSI. <br />WATER CLOSETS 1.28 GALLONS/FLUSH <br />THE EFFECTIVE FLUSH VOLUME OF DUAL FLUSH TOILETS IS DEFINED AS THE <br />COMPOSITE, AVERAGE FLUSH VOLUME OF TWO REDUCED FLUSHES AND ONE FULL <br />FLUSH. <br />URINALS 0.125 GALLON/FLUSH <br />METERING FAUCETS 0.2 GALLON/CYCLE <br />1. FLOW RATES ARE BASED ON THE 2022 CALIFORNIA GREEN BUILDING CODE STANDARDS SECTION 4.303 & 5.303. <br />NOTES: <br />THE DIAMETER OF AN INDIVIDUAL VENT SHALL NOT BE LESS THAN ONE AND ONE-FOURTH (1-1/4) INCHES NOR LESS THAN ONE-HALF (1/2) <br />THE DIAMETER OF THE DRAIN TO WHICH IT IS CONNECTED. FIXTURE UNIT LOAD VALUES FOR DRAINAGE AND VENT PIPING SHALL BE <br />COMPUTED FROM CALIFORNIA PLUMBING CODE TABLES 702.1 AND 702.2. NOT TO EXCEED ONE-THIRD (1/3) OF THE TOTAL PERMITTED <br />LENGTH OF ANY VENT MAY BE INSTALLED IN A HORIZONTAL POSITION. WHERE VENTS ARE INCREASED ONE (1) PIPE SIZE FOR THEIR <br />ENTIRE LENGTH, THE MAXIMUM LENGTH LIMITATIONS SPECIFIED IN THIS TABLE DO NOT APPLY. <br />CPC TABLE 703.2 <br />DRAINAGE AND VENT PIPE SIZING TABLE <br />NOMINAL <br />PIPE <br />DIAMETER <br />DRAINAGE PIPING MAXIMUM UNITS (DFU) <br />VERTICAL 2% SLOPE 1% SLOPE <br />DRAINAGE <br />PIPING MAX <br />VERTICAL <br />LENGTH (FT) <br />VENT PIPING HORIZONTAL <br />AND VERTICAL (SEE NOTE) <br />MAXIMUM <br />UNITS (DFU) <br />MAXIMUM <br />LENGTH (FT) <br />1-1/4"1 1 45 1 45 <br />1-1/2" <br />2" <br />3" <br />4" <br />5" <br />6" <br />8" <br />2 <br />16 <br />48 <br />256 <br />600 <br />1380 <br />3600 <br />1 <br />8 <br />35 <br />216 <br />428 <br />720 <br />2640 <br />172 <br />342 <br />576 <br />2112 <br />65 <br />85 <br />212 <br />300 <br />390 <br />510 <br />750 <br />8 <br />24 <br />84 <br />256 <br />600 <br />1380 <br />3600 <br />60 <br />120 <br />212 <br />300 <br />390 <br />510 <br />750 <br />2 <br />3 <br />4 <br />3 <br />4 <br />5 <br />5 <br />5 <br />5 <br />3 <br />1 <br />5 <br />4 <br />3 <br />2 <br />1 EXCLUDING TRAP ARM. <br />EXCEPT SINKS, URINALS AND DISHWASHERS - EXCEEDING 1 FIXTURE UNIT. <br />EXCEPT SIX-UNIT TRAPS OR WATER CLOSETS. <br />NOT TO EXCEED FIVE WATER CLOSETS OR FIVE SIX-UNIT TRAPS. <br />BASED ON ONE-FOURTH (1/4) INCH PER FOOT (2%) SLOPE. FOR ONE-EIGHTH (1/8) INCH PER FOOT (1%) SLOPE, <br />MULTIPLY HORIZONTAL FIXTURE UNITS BY A FACTOR OF 0.8. <br />6 WHERE IMPRACTICAL TO MAINTAIN 1/4 INCH PER FOOT UNIFORM SLOPE, DRAINAGE PIPE FOUR (4) INCHES OR LARGER <br />MAY HAVE A SLOPE NOT LESS THAN 1/8 INCH PER FOOT, WHEN FIRST APPROVED BY AUTHORITY HAVING JURISDICTION. <br />6 <br />6 <br />6 <br />6 <br />FLOW IN GPM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 <br />FIXTURE <br />UNITS <br />FLUSH TANK 0 1 3 4 6 7 8 10 12 13 15 16 18 20 21 <br />FLUSH VALVE - <br />16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 <br />23 24 26 28 30 32 34 36 39 42 44 46 49 51 54 <br />5 6 7 8 9 10 11 12 13 <br />31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 <br />56 58 60 63 66 69 74 78 83 86 90 95 99 103 107 <br />14 15 16 18 20 21 23 25 26 28 30 31 33 35 37 <br />-------------- <br />------ <br />FIXTURE UNITS VS. GPM CONVERSION TABLE <br />46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 <br />111 115 119 123 127 130 135 141 146 151 155 160 165 170 175 <br />39 42 44 46 48 50 52 54 57 60 63 66 69 73 76 <br />62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 <br />185 195 205 215 225 236 245 254 264 275 284 294 305 315 326 <br />82 88 95 102 108 116 124 132 140 148 158 168 176 186 195 <br />92 94 96 98 100 105 110 115 120 125 130 135 140 145 150 <br />337 348 359 370 380 406 431 455 479 506 533 559 585 611 638 <br />205 214 223 234 245 270 295 329 365 396 430 460 490 521 559 <br />FLOW IN GPM <br />FIXTURE <br />UNITS <br />FLUSH TANK <br />FLUSH VALVE <br />FLOW IN GPM <br />FIXTURE <br />UNITS <br />FLUSH TANK <br />FLUSH VALVE <br />FLOW IN GPM <br />FIXTURE <br />UNITS <br />FLUSH TANK <br />FLUSH VALVE <br />FLOW IN GPM <br />FIXTURE <br />UNITS <br />FLUSH TANK <br />FLUSH VALVE <br />FLOW IN GPM <br />FIXTURE <br />UNITS <br />FLUSH TANK <br />FLUSH VALVE <br />155 160 165 170 175 180 185 190 200 210 220 230 240 250 260 <br />665 692 719 748 778 809 840 879 945 1018 1091 1173 1254 1335 1418 <br />596 631 666 700 739 775 811 850 931 1009 1091 1173 1254 1335 1418 <br />FLOW IN GPM <br />FIXTURE <br />UNITS <br />1583 1668 1755 1845 1926 2018 2110 2204 2298 2388 2480 2575 2670 2765 <br />FLOW IN GPM <br />FIXTURE UNITS FLUSH TANK <br />FLUSH VALVE 1500 <br />420 430 440 450 500 550 600 650 700 750 800 850 900 950 1000 <br />2960 3060 3150 3620 4070 4480 4930 5380 5830 6280 6780 7280 7790 8300 <br />FLOW IN GPM <br />FIXTURE UNITS 2862 <br />270 280 290 300 310 320 330 340 350 360 370 380 390 400 410 <br />FLUSH TANK <br />FLUSH VALVE <br />FLUSH TANK <br />FLUSH VALVE <br />GPM EQUIVALENTS ARE BASED ON CPC CHARTS A 103.1(1) AND A 103.1(2). <br />INSULATION WALL THICKNESS <br />NOMINAL PIPE DIAMETER <br /> (INCHES) <br />LESS THAN 1"2 TO <4" <br />1"2" <br />1.75"1" TO 1.5" <br />1.5"1.75" <br />PIPE INSULATION THICKNESS <br />WATER HEATING SYTEMS <br />(105°-140° OPERATING RANGE) <br />R 7.7 R 12.5 R 11 R 11R-VALUE <br />8" & LARGER4" TO <8" <br />R 9 R 8 <br />2"2" <br />1.THE INSULATION FOR HOT WATER PIPES SHALL MEET THE MINIMUM THICKNESS PER CPC 609.12 AND CEC TABLE 120.3-A OR THE MINIMUM <br />R-VALUE PER CEC TABLE 120.3.-A. <br />2.INSULATION THICKNESSES SHOWN REPRESENT THE LARGER REQUIREMENT FOR DESIGNATED PIPE SIZES PER CPC SECTION 609.12 AND CEC <br />TABLE 120.3-A. <br />3.THE R-VALUES FOR ALL PIPE DIAMETERS ARE BASED ON TABLE 120.3-A OF THE CALIFORNIA ENERGY CODE. <br />GENERAL PIPE SIZING TABLES <br />WALL CLEANOUT <br />VENT <br />P-TRAP <br />GROUND CLEANOUT <br />WYE W/CLEANOUT PLUG <br />WYE <br />SANITARY TEE <br />FLOOR SINK, KITCHEN <br />FLOOR DRAIN, SQUARE <br />PLUMBING FIXTURES <br />FLOOR DRAIN <br />RISER ID TAG <br /># <br />TAG EQUIPMENT ID TAG <br />CONNECT TO EXISTING <br />VALVE SYMBOL <br />GLOBE <br />BALL <br />GATE <br />DIAPHRAGM <br />BUTTERFLY <br />3-WAY <br />4-WAY <br />SYMBOL REMARKS <br />TAG <br /># <br />SYMBOL REMARKS <br />PRESSURE REDUCING <br />ANGLE GATE <br />ANGLE GLOBE <br />RELIEF OR SAFETY <br />CHECK <br />TRIPLE DUTY VALVE <br />SOLENOID <br />DIAPHRAGM VALVE <br />S <br />(NORMALLY CLOSED) <br />VALVE (PRV) <br />W/PURGE PORTS <br />HOSE BIBB <br />UNION <br />PIPE CAP <br />90 DEG ELBOW DOWN <br />90 DEG ELBOW UP <br />TEE, SIDE <br />TEE, DOWN <br />TEE, UP <br />WATER HAMMER ARRESTER <br />PIPING FIXTURES <br />PIPE STUB <br />BUILDING SUPPLY <br />PIPE POINT OF CONNECTION <br />BACKFLOW PREVENTOR <br />WATER SUB-METER <br />TWH TERMINATION <br />CW CW <br />HW HW <br />HWR HW_RETURN <br />TEXT <br />SYMBOLS <br />CD CONDENSATE WASTE_BELOW <br />WASTE_ABOVE <br />VENT <br />RD ROOF DRAIN <br />SUBSURFACE <br />SD SD_ABOVE <br />OVERFLOW OFD <br />DRAIN <br />STORM DRAIN <br />PLUMBING LEGEND <br />SYMBOL REMARKS SYMBOL REMARKS <br />ABBREVIATIONS <br />SYMBOL REMARKS <br />ABOVE <br />CONDENSATE DRAIN <br />ABV <br />CD <br />HWR <br />CW <br />HW <br />CPC <br />CEC <br />CA PLUMBING CODE <br />CA ENERGY CODE <br />DOMESTIC COLD WATER <br />DOMESTIC HOT WATER <br />DOMESTIC HW RETURN <br />FORCED AIR UNIT <br />FLOOR <br />FEET PER SECOND <br />FAU <br />FLR <br />FPS <br />DN DOWN <br />GALLONS PER MINUTEGPM <br />TBD <br />V <br />TO BE DETERMINED <br />VENT <br />VTR <br />W <br />WCO <br />VENT TO ROOF <br />WASTE <br />WALL CLEANOUT <br />BELOWBLW <br />(E)EXISTING <br />SQ FT SQUARE FEET <br />NEW(N) <br />PSI POUND PER SQUARE INCH <br />BRITISH THERMAL UNITS PER HOURBTUH <br />CEILINGCLG <br />SD STORM DRAIN <br />OVERFLOW DRAINOFD <br />POINT OF CONNECTIONPOC <br />SOV SHUTOFF VALVE <br />INVERT ELEVATIONIE <br />SYMBOL REMARKS <br />RW RECYCLED <br />GW GREY_BELOW <br />GW GW GREY_ABOVE <br />GREASE WASTEGSW <br />GROUND CLEANOUTGCO <br />RW RECYCLED WATER <br />GREYWATERGW <br />SSD SUBSURFACE DRAIN <br />WATER <br />EQUIP <br />GSW GREASE_BELOW <br />GSW GSW GREASE_ABOVE <br />FIXTURE SCHEDULE <br />ITEM FIXTURE <br />CO <br />L <br />D <br />WA <br />T <br />E <br />R <br />HO <br />T <br />WA <br />T <br />E <br />R <br />WA <br />S <br />T <br />E <br />VE <br />N <br />T <br />ST <br />O <br />R <br />M <br />DR <br />A <br />I <br />N <br />DESCRIPTION <br />ICE MAKER BOX 1/2"----SELECTION TBD BY OWNER. PROVIDE WATER HAMMER ARRESTOR. <br />PROVIDE A FIRE-RATED OUTLET BOX WHERE APPLICABLE. <br />DISHWASHER -3/4"---DRAIN TO KITCHEN SINK. SELECTION TBD BY OWNER. PROVIDE <br />WATER HAMMER ARRESTOR. <br />KITCHEN SINK 3/4"3/4"2"1-1/2"-1.8 GPM FAUCET. SELECTION TBD BY OWNER. <br />HUB DRAIN --2"1-1/2"-SIOUX CHIEF OXBOX DRAIN BOX WITH SECONDARY DRAIN FUNNEL. <br />PROVIDE TRAP PRIMER. <br />WATER CLOSET, FLUSH <br />TANK 3/4"-3"2"-1.28 GPF, FLUSHTANK TYPE. SELECTION TBD BY OWNER. <br />TUB-SHOWER COMBO 3/4"3/4"2"1-1/2"- <br />SELECTION TBD BY OWNER.1.8 GPM SHOWER HEAD. PROVIDE A <br />THERMOSTATIC OR PRESSURE BALANCE TYPE MIXING VALVE FOR <br />THERMAL SHOCK AND SCALD PROTECTION. <br />LAVATORY 1/2"1/2"2"1-1/2"-1.2 GPM FAUCET. SELECTION TBD BY OWNER. <br />CLOTHES WASHER BOX (3 <br />OR MORE)3/4"3/4"3"2"-SELECTION TBD BY OWNER. PROVIDE WATER HAMMER ARRESTOR. <br />PROVIDE A FIRE-RATED OUTLET BOX WHERE APPLICABLE. <br />FIRE SPRINKLER HUB <br />DRAIN <br />TRAP <br />PRIMER -4"2"-STANDPIPE FOR FLUSHING FIRE SPRINKLER SYSTEM <br />ELECTRONIC TRAP <br />PRIMER 1/2"---- <br />P.P.P NO. MPB-500 (120/60 VOLT, 6.3 WATTS), MINI-PRIME <br />ELECTRONIC TRAP PRIMING MANIFOLD W/BOX (INSTALL PER <br />MANUFACTURER'S RECOMMENDATIONS). <br />TRAP PRIMER 1/2"---- <br />PPP PR-500 PRESSURE DROP ACTIVATED TRAP PRIMER (INSTALL <br />PER MANUFACTURER'S RECOMMENDATIONS). SELECT THE <br />DISTRIBUTION UNIT DU-U OPTION IF CONNECTED TO TWO FLOOR <br />DRAINS. <br />FLOOR DRAIN --2"1-1/2"-SELECTION TBD BY OWNER. PROVIDE TRAP PRIMER. <br />HOSE BIBB 3/4"----WALL MOUNTED WITH ATMOSPHERIC VACUUM BREAKER. <br />ARROWHEAD ARROWBREAKER MODEL OR EQUIVALENT. <br />MOP SINK 3/4"3/4"3"2"-SELECTION TBD BY OWNER. <br />IMB <br />1 <br />DW <br />1 <br />KS <br />1 <br />HD <br />1 <br />WC <br />1 <br />BT <br />1 <br />L <br />1 <br />WSH <br />1 <br />SHD <br />1 <br />TP <br />1 <br />TP <br />2 <br />FD <br />1 <br />HB <br />1 <br />MS <br />1 <br />PIPING MATERIAL SCHEDULE <br />DOMESTIC WATER PIPING <br />INSIDE BUILDING ABOVE FLOOR <br />SIZES 1/2" TO 2" <br />UPONOR 'AQUAPEX' PEX TUBING WITH PROPEX (EP) FITTINGS, OR ALTERNATE BRANDS CONFORMING TO ASTM <br />F876 AND ASTM F877 STANDARDS AND SDR9 DIMENSIONAL STANDARD. <br />NOTE: <br />1. THE INSTALLATION OF PEX TUBING IN POTABLE WATER SUPPLY SYSTEMS MUST FOLLOW INDIVIDUAL MANUFACTURERS' INSTALLATION <br />PROCEDURES AND THE PROCEDURES SET FORTH IN 2022 CPC SECTIONS 605.9 THRU 605.9.3. <br />2. PEX TUBING WHEN PLACED IN THE SOIL AND USED IN POTABLE WATER SYSTEMS INTENDED TO SUPPLY DRINKING WATER, THE TUBING <br />SHALL BE SLEEVED WITH A MATERIAL APPROVED FOR POTABLE PAGE 3 OF 3 PERMIT TRACKING NUMBER 3014-6191-241 WATER USE IN <br />SOIL OR MATERIAL(S) THAT ARE IMPERVIOUS TO SOLVENTS OR PETROLEUM PRODUCTS. 2022 CPC TBL. 604.1 FOOTNOTE #3. <br />3. PEX TUBING SHALL MEET OR EXCEED THE REQUIREMENTS OF ASTM F876-2015A WHEN USED IN CONTINUOUSLY RECIRCULATING HOT <br />WATER SYSTEMS WHERE PEX TUBING IS EXPOSED TO THE HOT WATER 100% OF THE TIME. 2022 CPC TBL. 604.1 FOOTNOTE #4. <br />4. NEW POTABLE WATER SYSTEMS ARE REQUIRED TO BE DISINFECTED BY CHLORINATION. 2022 CPC SEC.609.10 (1, 2, 3, 4). <br />SEWER, WASTE AND VENT PIPING <br />INSIDE BUILDING ABOVE FLOOR <br />SCHEDULE 40 PVC OR ABS PLASTIC PIPE WITH DWV TYPE FITTINGS. <br />SEWER, WASTE AND VENT PIPING <br />INSIDE BUILDING BELOW GRADE <br />SCHEDULE 40 PVC OR ABS PLASTIC PIPE WITH DWV TYPE FITTINGS. <br />1.BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH CPC SECTIONS 701.0 AND 903.0. <br />2.ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTING AGENCY. <br />3.ANY COPPER PIPING JOINTS UNDER CONCRETE SLAB SHALL BE BRAZED INSTEAD OF SOLDERED. <br />4.TYPE M COPPER TUBING MAY BE USED FOR ABOVE GROUND WATER PIPING INSIDE OR ON THE BUILDING. <br />5.CPVC TUBING MAY BE USED FOR CONDENSATE DRAIN PIPING WHEN DISCHARGE FROM FLUE-BURNING APPLIANCES IS ACIDIC OR CORROSIVE. <br />6.ALL COPPER PIPING INSTALLED BELOW GRADE SHALL BE COATED. <br />EQUIP. NUMBER <br />LOCATION <br />MANUFACTURER <br />SERIES <br />MODEL <br />TYPE <br />TOTAL VOLUME <br />ACCEPTANCE FACTOR <br />MAX TEMPERATURE <br />MAX PRESSURE <br />FACTORY PRECHARGE <br />PH <br />Y <br />S <br />DA <br />T <br />A <br />DIAMETER <br />HEIGHT <br />CONNECTION <br />SHIPPING WEIGHT <br />EXPANSION TANK SCHEDULE <br />*ANY WATER SYSTEM PROVIDED WITH A CHECK VALVE <br />OR BACKFLOW PREVENTER SHALL BE PROVIDED WITH AN <br />APPROVED, LISTED, ADEQUATELY SIZED EXPANSION <br />TANK OR OTHER APPROVED DEVICE HAVING A SIMILAR <br />FUNCTION TO CONTROL THERMAL EXPANSION. <br />AMTROL <br />THERM-X-TROL <br />ST-5 <br />IN-LINE <br />2.0 GALLONS <br />0.45 <br />200°F <br />150 PSIG <br />50 PSIG <br />8" <br />13" <br />3/4" NPT <br />5 LBS <br />ET <br />BY WH-1 <br />1 <br />WATER HEATER ROOM <br />RHEEM <br />PROH50 T2 RH310BM <br />HYBRID ELECTRIC <br />67 <br />26 <br />37-145°F <br />N/A <br />3.50 <br />22-1/4"D X 61"H <br />172 <br />3/4" NPT <br />208-240V - 1PH <br />24 A <br />WH <br />1 <br />HYBRID ELECTRIC WATER <br />HEATER SCHEDULE <br />EQUIPMENT NUMBER <br />MANUFACTURER <br />LOCATION <br />MODEL <br />TYPE <br />WATER CONN. <br />PH <br />Y <br />S <br />DA <br />T <br />A <br />WEIGHT (EMPTY) <br />DIMENSIONS <br />CO <br />N <br />N <br />. <br />SI <br />Z <br />E <br />SUPPLY <br />POWEREL <br />E <br />C <br />. <br />DA <br />T <br />A <br />1ST HOUR RATING GPH <br />AMBIENT OPERATING RANGE <br />ENERGY FACTOR (ELECTRIC) <br />RECOVERY 90°F RISE, GPH <br />ENERGY FACTOR (EFFICIENT) <br />HYBRID ELECTRIC WATER <br />HEATER SCHEDULE <br />EQUIPMENT NUMBER <br />MANUFACTURER <br />LOCATION <br />MODEL <br />TYPE <br />WATER CONN. <br />PH <br />Y <br />S <br />DA <br />T <br />A <br />WEIGHT (EMPTY) <br />DIMENSIONS <br />CO <br />N <br />N <br />. <br />SI <br />Z <br />E <br />SUPPLY <br />BREAKER SIZEEL <br />E <br />C <br />. <br />DA <br />T <br />A <br />1ST HOUR RATING GPH <br />RECOVERY 90°F RISE, GPH <br />AMBIENT OPERATING RANGE <br />ENERGY FACTOR (EFFICIENT) <br />*OR APPROVED EQUAL <br />2 <br />WH <br />RHEEM* <br />HPLD80* <br />HYBRID ELECTRIC <br />WATER HEATER ROOM <br />244 <br />24-1/4"D X 74"H <br />3/4" NPT <br />89 <br />29 <br />35-145°F <br />3.70 <br />208V- 1PH - 30 AMPS <br />30 <br />P-0.2 <br />MATERIAL AND <br />FIXTURE SCHEDULES <br />PC COMMENTS RESPONSE #1 01/29/2025A <br />al <br />l <br /> <br />i <br />d <br />e <br />a <br />s <br />, <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />s <br /> <br />a <br />n <br />d <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />r <br />e <br />p <br />r <br />e <br />s <br />e <br />n <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />t <br />h <br />i <br />s <br /> <br />d <br />r <br />a <br />w <br />i <br />n <br />g <br /> <br />a <br />r <br />e <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />c <br />l <br />u <br />s <br />i <br />v <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br />Go <br />u <br />v <br />i <br />s <br /> <br />E <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br /> <br />a <br />n <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />i <br />n <br /> <br />w <br />h <br />o <br />l <br />e <br /> <br />o <br />r <br /> <br />i <br />n <br /> <br />p <br />a <br />r <br />t <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br /> <br />p <br />r <br />i <br />o <br />r <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />o <br />f <br /> <br />s <br />a <br />i <br />d <br /> <br />e <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />s <br />, <br /> <br />a <br />n <br />y <br /> <br />u <br />n <br />a <br />u <br />t <br />h <br />o <br />r <br />i <br />z <br />e <br />d <br /> <br />r <br />e <br />u <br />s <br />e <br /> <br />o <br />f <br /> <br />t <br />h <br />e <br />s <br />e <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />o <br />t <br />h <br />e <br />r <br /> <br />t <br />h <br />a <br />n <br /> <br />f <br />o <br />r <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />j <br />e <br />c <br />t <br /> <br />a <br />n <br />d <br /> <br />l <br />o <br />c <br />a <br />t <br />i <br />o <br />n <br /> <br />s <br />h <br />o <br />w <br />n <br /> <br />i <br />s <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br />JOB NO. <br />SUBMITTAL <br />DATE <br />SHEET TITLE <br />SHEET NO. <br />CLIENT: <br />REVISION <br />DATE <br />21 <br />3 <br />0 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br /> <br /># <br />2 <br />0 <br />0 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />BSB: MR230056; Gouvis: 66467 <br />WATER REVISIONS <br />09/12/2025 <br />1ST PLAN CHECK SUBMITTAL 08/20/2024 <br />2ND PLAN CHECK SUBMITTAL 1/29/2025 <br />PC COMMENTS RESPONSE #2 04/17/2025B <br />3RD PLAN CHECK SUBMITTAL 04/17/2025 <br />PC COMMENTS RESPONSE #3 07/10/2025C <br />4TH PLAN CHECK SUBMITTAL 07/10/2025 <br />WATER REVISIONS 09/12/2025D <br />WATER REVISIONS 09/12/2025 <br />PC COMMENTS RESPONSE #4 10/10/2025E <br />CLIENT REVISIONS 10/10/20251 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />T <br />I <br />A <br />L <br />21 <br />5 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />A <br />N <br />D <br /> <br />2 <br />1 <br />6 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br />DATE SIGNED: 7/8/25
The URL can be used to link to this page
Your browser does not support the video tag.