My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2130, 2150 & 2160 E Fourth St - Electrical Revision - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fourth St
>
2130 E Fourth St
>
2130, 2150 & 2160 E Fourth St - Electrical Revision - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 5:00:13 AM
Creation date
1/15/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
20187473
20187474
20187475
Full Address
2130 E Fourth St
2150 E Fourth St
2160 E Fourth St
Street Number
2160
Street Direction
E
Street Name
Fourth
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DS <br />DS <br />DS <br />DS <br />DS <br />DS <br />RI <br />D <br />G <br />E <br />RIDGE RIDGE <br />RI <br />D <br />G <br />E <br />RI <br />D <br />G <br />E <br />VAL <br />L <br />E <br />Y <br />VAL <br />L <br />E <br />Y <br />VAL <br />L <br />E <br />Y <br />VAL <br />L <br />E <br />Y <br />VAL <br />L <br />E <br />Y <br />VAL <br />L <br />E <br />Y <br />1.ALL ELECTRICAL DEVICES LOCATED OUTDOOR SHALL BE W.P. <br />2.ALL PENETRATIONS TO THE ROOF SHALL BE W.P. <br />3.ALL ELECTRICAL ROOF PENETRATION SHALL BE 12 " AWAY FROM ANY EQUIPMENTS. <br />4.ALL CONDUIT RUNS SHALL BE INSTALLED IN THE CEILING SPACE BELOW ROOF. <br />EXPOSED HORIZONTAL CONDUIT RUNS ON ROOF ARE NOT PERMITTED. <br />5.COORDINATE EXACT POINT OF CONNECTION TO HVAC UNITS WITH HVAC <br />CONTRACTOR PRIOR TO ROUGH - IN. <br />6.PROVIDE & INSTALL 3/4"C., 8 # 18 FROM EACH HVAC UNIT TO RESPECTIVE <br />THERMOSTAT. <br />7.REFER TO HVAC DRAWINGS FOR EXACT LOCATION OF ALL HVAC UNITS. <br />8.PROVIDE & INSTALL 3/4"C., WITH REQUIRED CONTROL WIRES FROM NEW <br />CONDENSING UNITS (LOCATED ON ROOF) TO NEW FAN COIL UNITS (LOCATED <br />ABOVE CEILING) AND TO RESPECTIVE THERMOSTAT. <br />9.E.C. SHALL REFER TO HVAC PLANS AND DETAILS FOR ADDITIONAL LABOR AND <br />MATERIAL REQUIRED AS NOTED. <br />10.SEE SINGLE LINE DIAGRAM AND PANEL SCHEDULES FOR FEEDER SIZE AND <br />ADDITIONAL INFORMATION. <br />11.ALL CONDUIT SHALL PENETRATE THE ROOF AT THE POINT OF CONNECTION AND <br />SHALL BE ROUTED TIGHT UNDER THE DECK , ROOF MOUNTED CONDUIT SHALL NOT <br />BE PERMITTED. <br />12.COORDINATE ALL REQUIREMENTS AND POINTS OF CONNECTION WITH THE <br />MECHANICAL CONTRACTOR. <br />13.MOUNT DISCONNECTS ON UNITS OR FREESTANDING ON ROOF USING UNISTRUT <br />SUPPORTS. <br />14.MAKE FINAL CONNECTIONS TO UNITS USING WEATHERTIGHT FLEXIBLE CONDUIT. <br />15.PROVIDE FINAL FUSE SIZES FOR THE MANUFACTURES REQUIREMENTS. <br />ROOF PLAN NOTES <br />PC COMMENTS RESPONSE #1 01/29/2025A <br />al <br />l <br /> <br />i <br />d <br />e <br />a <br />s <br />, <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />s <br /> <br />a <br />n <br />d <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />r <br />e <br />p <br />r <br />e <br />s <br />e <br />n <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />t <br />h <br />i <br />s <br /> <br />d <br />r <br />a <br />w <br />i <br />n <br />g <br /> <br />a <br />r <br />e <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />c <br />l <br />u <br />s <br />i <br />v <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br />Go <br />u <br />v <br />i <br />s <br /> <br />E <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br /> <br />a <br />n <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />i <br />n <br /> <br />w <br />h <br />o <br />l <br />e <br /> <br />o <br />r <br /> <br />i <br />n <br /> <br />p <br />a <br />r <br />t <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br /> <br />p <br />r <br />i <br />o <br />r <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />o <br />f <br /> <br />s <br />a <br />i <br />d <br /> <br />e <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />s <br />, <br /> <br />a <br />n <br />y <br /> <br />u <br />n <br />a <br />u <br />t <br />h <br />o <br />r <br />i <br />z <br />e <br />d <br /> <br />r <br />e <br />u <br />s <br />e <br /> <br />o <br />f <br /> <br />t <br />h <br />e <br />s <br />e <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />o <br />t <br />h <br />e <br />r <br /> <br />t <br />h <br />a <br />n <br /> <br />f <br />o <br />r <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />j <br />e <br />c <br />t <br /> <br />a <br />n <br />d <br /> <br />l <br />o <br />c <br />a <br />t <br />i <br />o <br />n <br /> <br />s <br />h <br />o <br />w <br />n <br /> <br />i <br />s <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br />JOB NO. <br />SUBMITTAL <br />DATE <br />SHEET TITLE <br />SHEET NO. <br />CLIENT: <br />REVISION <br />DATE <br />21 <br />3 <br />0 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br /> <br /># <br />2 <br />0 <br />0 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />BSB: MR230056; Gouvis: 66467 <br />WATER REVISIONS <br />09/12/2025 <br />1ST PLAN CHECK SUBMITTAL 08/20/2024 <br />2ND PLAN CHECK SUBMITTAL 1/29/2025 <br />PC COMMENTS RESPONSE #2 04/17/2025B <br />3RD PLAN CHECK SUBMITTAL 04/17/2025 <br />PC COMMENTS RESPONSE #3 07/10/2025C <br />4TH PLAN CHECK SUBMITTAL 07/10/2025 <br />WATER REVISIONS 09/12/2025D <br />WATER REVISIONS 09/12/2025 <br />PC COMMENTS RESPONSE #4 10/10/2025E <br />CLIENT REVISIONS 10/10/20251 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />T <br />I <br />A <br />L <br />21 <br />5 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />A <br />N <br />D <br /> <br />2 <br />1 <br />6 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br />DATE SIGNED: 7/8/25 <br />BUILDING A1 - ROOF PLAN 1 <br />12' <br /> 1/4" = 1'-0" <br />2'8'4'0 <br />E-2.3 <br />BUILDING A1 <br />ROOF PLAN
The URL can be used to link to this page
Your browser does not support the video tag.