My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2130, 2150 & 2160 E Fourth St - Electrical Revision - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fourth St
>
2130 E Fourth St
>
2130, 2150 & 2160 E Fourth St - Electrical Revision - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 5:00:13 AM
Creation date
1/15/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
20187473
20187474
20187475
Full Address
2130 E Fourth St
2150 E Fourth St
2160 E Fourth St
Street Number
2160
Street Direction
E
Street Name
Fourth
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PC COMMENTS RESPONSE #1 01/29/2025A <br />al <br />l <br /> <br />i <br />d <br />e <br />a <br />s <br />, <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />s <br /> <br />a <br />n <br />d <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />r <br />e <br />p <br />r <br />e <br />s <br />e <br />n <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />t <br />h <br />i <br />s <br /> <br />d <br />r <br />a <br />w <br />i <br />n <br />g <br /> <br />a <br />r <br />e <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />c <br />l <br />u <br />s <br />i <br />v <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br />Go <br />u <br />v <br />i <br />s <br /> <br />E <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br /> <br />a <br />n <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />i <br />n <br /> <br />w <br />h <br />o <br />l <br />e <br /> <br />o <br />r <br /> <br />i <br />n <br /> <br />p <br />a <br />r <br />t <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br /> <br />p <br />r <br />i <br />o <br />r <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />o <br />f <br /> <br />s <br />a <br />i <br />d <br /> <br />e <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />s <br />, <br /> <br />a <br />n <br />y <br /> <br />u <br />n <br />a <br />u <br />t <br />h <br />o <br />r <br />i <br />z <br />e <br />d <br /> <br />r <br />e <br />u <br />s <br />e <br /> <br />o <br />f <br /> <br />t <br />h <br />e <br />s <br />e <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />o <br />t <br />h <br />e <br />r <br /> <br />t <br />h <br />a <br />n <br /> <br />f <br />o <br />r <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />j <br />e <br />c <br />t <br /> <br />a <br />n <br />d <br /> <br />l <br />o <br />c <br />a <br />t <br />i <br />o <br />n <br /> <br />s <br />h <br />o <br />w <br />n <br /> <br />i <br />s <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br />JOB NO. <br />SUBMITTAL <br />DATE <br />SHEET TITLE <br />SHEET NO. <br />CLIENT: <br />REVISION <br />DATE <br />21 <br />3 <br />0 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br /> <br /># <br />2 <br />0 <br />0 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />BSB: MR230056; Gouvis: 66467 <br />WATER REVISIONS <br />09/12/2025 <br />1ST PLAN CHECK SUBMITTAL 08/20/2024 <br />2ND PLAN CHECK SUBMITTAL 1/29/2025 <br />PC COMMENTS RESPONSE #2 04/17/2025B <br />3RD PLAN CHECK SUBMITTAL 04/17/2025 <br />PC COMMENTS RESPONSE #3 07/10/2025C <br />4TH PLAN CHECK SUBMITTAL 07/10/2025 <br />WATER REVISIONS 09/12/2025D <br />WATER REVISIONS 09/12/2025 <br />PC COMMENTS RESPONSE #4 10/10/2025E <br />CLIENT REVISIONS 10/10/20251 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />T <br />I <br />A <br />L <br />21 <br />5 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />A <br />N <br />D <br /> <br />2 <br />1 <br />6 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br />DATE SIGNED: 7/8/25 <br />ABBREVIATIONS <br />E-0.2 <br />ABBREVIATIONS & <br />SYMBOLS LIST <br />CIRCUIT BREAKER <br />DRAWOUT CIRCUIT BREAKER <br />FUSED SWITCH <br />TRANSFORMER <br />AUTOMATIC TRANSFER SWITCH <br />GENERATOR <br />PANELBOARD <br />METER <br />MOTOR OR EQUIPMENT AS NOTED <br />UNDERGROUND PULL SECTION LANDING LUGS <br />SHUNT TRIP <br />ELECTRONIC TRIP UNIT: <br />L - LONG-TIME TRIP <br />S - SHORT-TIME TRIP <br /> I - INSTANTANEOUS TRIP <br />G - GROUND-FAULT TRIP, GROUND FAULT SENSING INTEGRAL WITH CIRCUIT BREAKER. <br />FUSE CUTOUT <br />DRY TYPE <br />TRANSFORMER <br />WYE CONFIGURATION <br />DELTA CONFIGURATION <br />GROUND <br />UTILITY COMPANY METER. PROVIDE CT'S & PT'S AS REQUIRED. <br />REFER TO SINGLE LINE DIAGRAM. <br />CURRENT TRANFORMERS <br />DISCONNECT SWITCH FURNISHED W/ EQUIPMENT <br />START-STOP CONTROL STATION <br />HAND-OFF AUTO CONTROL STATION <br />GROUND FAULT RELAY <br />GROUND FAULT PROTECTION <br />PANEL <br />G <br />M <br />ST <br />LSIG <br />M kW <br />U <br />H <br />A <br />O <br />GF <br />GFP <br />LIGHT (SURFACE MOUNT) <br />LIGHT (RECESS MOUNT) <br />LIGHT (WALL MOUNT) <br />J-BOX ( CEILING MOUNTED) <br />EMERGENCY LIGHT( BUG EYE) <br />PENDANT LED LIGHT <br />UNDER CABINET LINEAR LIGHT FIXTURE <br />1' X 4' LIGHT <br />1' X 4' LIGHT <br />WITH 90 MINUTES BATTERY PACK <br />LIGHTING <br />TELEVISION OUTLET <br />PUSH-BUTTON SWITCH <br />DOOR BELL CHIME <br />TELEPHONE OUTLET <br />DATA OUTLET <br />COMBINATION TELEPHONE AND DATA OUTLET BOX WALL <br />SWITCH <br />SINGLE POLE, ab = CONTROL ZONES a & b <br />3-WAY <br />ab <br />3ab <br />4-WAY4ab <br />D DIMMER SWITCH <br />DAY LIGHT SENSOR(CEILING) <br />OCCUPANCY SENSOR(CEILING) <br />TRACK LIGHT <br />OCCUPANCY SENSOR(WALL) <br />J <br />DS <br />OS <br />TV <br />POWER PACKPP <br />OS <br />MECHANICAL <br />CONDENSING UNIT (CU) OR HEAT PUMP (HP) <br />FORCED AIR UNIT (FAU) OR FAN COIL UNIT (FC) <br />FUSED DISCONNECT SWITCH <br />MISC <br />SD <br />SMOKE DETECTOR AND CARBON MONOXIDE COMBO <br />HARDWIRED W/ BATTERY BACKUP <br />SMOKE DETECTOR HARDWIRED W/ BATTERY BACKUP <br />SD CO <br />SITE LIGHTING <br />X <br />FAU <br />POLE LIGHT <br />POST LIGHT <br />BOLLARD LIGHT <br />UPLIGHT LIGHT <br />TREE LIGHT <br />KEYED NOTE SYMBOL <br />LIGHT (SURFACE MOUNT) <br />WITH 90 MINUTES BATTERY PACK <br />LIGHT (RECESS MOUNT) <br />WITH 90 MINUTES BATTERY PACK <br />EXIT SIGN (CEILING MOUNTED) <br />P1 PANEL <br />JUNCTION BOX (WALL MOUNTED) <br />EXIT SIGN (WALL MOUNTED) <br />NOTE:VERIFY ALL LIGHT FIXTURES WITH OWNER/ ARCHITECT PRIOR TO BID. LIGHTS AND PANEL SHALL NOT <br />BE RECESSED IN FIRE RATED ASSEMBLIES UNLESS BOXED WITH EQUIVALENT CONSTRUCTION. <br />NOTE:LIGHT SWITCHES AND CONTROLS, WALL MOUNTED AT +48" AFF (MAX) <br />ALL WALL SWITCHES CONTROLLING EMERGENCY CIRCUITS SHALL BE ENGRAVED WITH <br />"EMERGENCY" ON RED FACE PLATE <br />NOTE:ALL A.I.C. RATINGS OF ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE VERIFIED WITH LOCAL <br />UTILITY COMPANY HAVING JURISDICTION PRIOR TO BID. <br />NOTE:ALL A.I.C.RATINGS OF ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE VERIFIED WITH <br />LOCAL UTILITY COMPANY HAVING JURISDICTION PRIOR TO BID. <br />EXHAUST FAN (EF)EF <br />X <br />EF <br />J <br />J <br />ABS ABOVE BACKSPLASH IG ISOLATED GROUND T TRANSFORMER <br />ADA AMERICAN WITH DISABILITY ACT IN OR "INCHES TC TIME CLOCK <br />AFF ABOVE FINISHED FLOOR INCAD INCANDESCENT TELC TELEPHONE CABINET <br />AFG ABOVE FINISHED GROUND TEL TELEPHONE <br />AFCI ARC FAULT CIRCUIT INTERRUPTER JB/JBOX JUNCTION BOX TELCOM TELECOMMUNICATIONS <br />AIC AMPERE INTERRUPTING CAPACITY TELE/DATA TELEPHONE & DATA <br />AF/AT AMP FRAME, AMP TRIP K DEGREE KELVIN TV TELEVISION <br />ANN FIRE ALARM ANNUNCIATOR PANEL KVA KILOVOLT AMPERES TP TAMPER PROOF <br />AS/AF AMP SWITCH, AMP FUSE KW KILOWATT TYP TYPICAL <br />AMP, A AMPERE KCMIL THOUSAND CIRCULAR MILS TSP TWISTED SHIELDED PAIR <br />ARCH ARCHITECTURAL <br />ASYM ASYMMETRICAL LC LIGHTING CONTACTOR UBP UTILITY BRANCH PANEL <br />ATS AUTOMATIC TRANSFER SWITCH LCL LINE CONTINUOUS LOAD UG UNDERGROUND <br />AV AUDIO VISUAL LCP LIGHTING CONTROL PANEL UGPS UNDERGROUND PULL SECTION <br />AWG AMERICAN WIRE GAUGE LF LINEAR FEET UON UNLESS OTHERWISE NOTED <br />LPS LOW PRESSURE SODIUM UPS UNINTERRUPTIBLE POWER SUPPLY <br />BATT BATTERY LT LIGHTING TRANSFORMER UT UTILITY POWER TRANSFORMER <br />BC BARE COPPER LTG/LTS LIGHTING UTP UNSHIELDED TWISTED PAIR <br />BCG BARE COPPER GROUND LSI LONG TIME, SHORT TIME, INSTANTANOUS <br />BKR BREAKER LSIG LONG TIME, SHORT TIME, INSTANTANOUS, GROUND V VOLTS <br />BLDG BUILDING VA VOLTS AMPETERS <br />BOT BOTTOM OF TRAY M METER VD VOLTAGE DROP <br />MAX MAXIMUM VFD VARIABLE FREQUENCY DRIVE <br />C CONDUIT MCA MINIMUM CIRCUIT AMPACITY <br />°C CELSIUS MCB MAIN CIRCUIT BREAKER W WIRE <br />CAB CABINET MCC MOTOR CONTROL CENTER WP WEATHERPROOF <br />CB CIRCUIT BREAKER MFR MANUFACTURER <br />CKT CIRCUIT MH MOUNTING HEIGHT XFMR TRANSFORMER <br />CLCB CURRENT LIMITING CIRCUIT BREAKER MH METAL HALIDE XFR TRANSFER <br />CLF CURRENT LIMITING FUSE MLO MAIN LUGS ONLY <br />CLG CEILING MOCP MAXIMUM OVERCURRENT PROTECTION Y WYE CONNECTION <br />CM/GC CONSTRUCTION MANAGER/GENERAL CONTRACTOR MTD MOUNTED <br />C.O.CONDUIT ONLY, COMPLETE WITH PULL WIRE MS MAIN SWITCHBOARD <br />COMM COMMUNICATIONS MV MERCURY VAPOR <br />CONN CONNECTED MW MICROWAVE <br />CONST CONSTRUCTION <br />CONT CONTINUATION N NEUTRAL <br />CPT CONTROL POWER TRANSFORMER NC NORMALLY CLOSED <br />CT CURRENT TRANSFORMER NEC NATIONAL ELECTRICAL CODE <br />CPT CLEAN POWER TRANFORMER NF NON-FUSED <br />NIC NOT IN CONTRACT <br />Δ DELTA CONNECTED NL NIGHT LIGHT <br />DB DISTRIBUTION BOARD NO NORMALLY OPEN <br />DIA DIAMETER NO. OR #NUMBER <br />DISC SW DISCONNECT SWITCH <br />DIST DISTRIBUTION OFCI OWNER FURNISHED, CONTRACTOR INSTALLED <br />DEG DEGREE <br />DP DISTRIBUTION PANELBOARD P POLE <br />DT DIRTY POWER TRANFORMER PA PUBLIC ADDRESS <br />DWG DRAWING PB PULL BOX <br />DW DISH WASHER PC PHOTOCELL <br />PH OR ɸ PHASE <br />EF EXHAUST FAN PL POLE <br />EG EQUIPMENT GROUND PR PAIR <br />(E)EXISTING PRI PRIMARY <br />EL ELEVATION PRIMARY OVER 600 VOLTS <br />ELEC ELECTRICAL PROVIDE FURNISH, INSTALL, AND CONNECT <br />ELEV ELEVATOR PT POTENTIAL TRANSFORMER <br />EMER EMERGENCY PWR POWER <br />EMS ENERGY MANAGEMENT SYSTEM <br />EMT ELECTRICAL METALLIC TUBING QTY QUANTITY <br />ENT ELECTRICAL NON-METALLIC TUBING <br />E.O.L.END-OF-LINE CIRCUIT TERMINATOR RECPT, REC RECEPTACLE <br />EP EXPLOSION PROOF REF REFRIGERATOR <br />EQPT EQUIPMENT REQD REQUIRED <br />EWC ELECTRIC WATER COOLER RGS RIGID GALVANIZED STEEL <br />EXIST EXISTING RM ROOM <br />RP REC BUILDING PANEL <br />FA FIRE ALARM ROIC RESIDENT OFFICER IN CHARGE OF CONSTRUCTION <br />FACP FIRE ALARM CONTROL PANEL <br />FATC FIRE ALARM TERMINATION CABINET SBG STANDBY GENERATOR <br />FDR FEEDER SDPB STANDBY DISTRIBUTION PANELBOARD <br />FIXT FIXTURE SEC SECURITY <br />FLA FULL LOAD AMPS SECONDARY 600 VOLTS AND LESS <br />FLR FLOOR SECT SECTION <br />FLOUR FLUORESCENT SF/SQFT SQUARE FOOT <br />FT OR 'FEET SN SOLID NEUTRAL <br />FP FIRE PUMP SPEC SPECIFICATION <br />SP SUMP PUMP <br />G/GND GROUND SQ SQUARE <br />GEF GARAGE EXHAUST FAN SSG SECONDARY SWITCHGEAR <br />GFCI GROUND FAULT CIRCUIT INTERRUPTER ST SHUNT TRIP <br />GFP GROUND FAULT PROTECTION SURF SURFACE <br />SW SWITCH <br />H HOT (UNSWITCHED)SYM SYMMETRICAL <br />HID HIGH INTENSITY DISCHARGE SYS SYSTEMS <br />HOA HAND OFF AUTO <br />HP HORSE POWER <br />HPS HIGH PRESSURE SODIUM <br />HTR HEATER <br />HVAC HEATING, VENTILATION, & AIR CONDITIONING <br />H.W.D.L.HEIGHT, WIDTH, DEPTH, LENGTH <br />LIGHT MARK <br />X <br />CU <br />X <br />HP <br />F <br />NON-FUSED DISCONNECT SWITCH <br />T THERMALLY RATED 2P MOTOR SWITCH <br />X <br />FC <br />SMOKE DUCT DETECTOR (SDD)X <br />SDDSDD <br />M MANUAL MOTOR RATED SWITCH <br />OUTLETS <br />DUPLEX RECEPTACLE <br />QUAD RECEPTACLE <br />SPECIAL RECEPTACLE <br />DUPLEX USB <br />GFCI DUPLEX RECEPTACLE <br />GFCI DUPLEX RECEPTACLE WITH WEATHERPROOF COVER <br />DUPLEX RECEPTACLE, BOTTOM HALF SWITCHED <br />DUPLEX CEILING RECEPTACLE <br />DUPLEX FLOOR RECEPTACLE <br />DUPLEX ABOVE COUNTER <br />CONTROLLER ABOVE COUNTER <br />DUPLEX W/USB (TYP. ABOVE COUNTER) <br />CONTROLLER W/USB (TYP. ABOVE COUNTER) <br />NOTE:ALL WALL MOUNTED RECEPTACLE SHALL BE +18" AFF U.O.N. <br />ALL WALL COUNTER MOUNTED RECEPTACLE SHALL BE GFCI AND 6" ABOVE SPLASH. COORDINATE <br />WITH ARCHITECTURAL DRAWINGS. <br />QUAD FLOOR RECEPTACLE <br />GFCI DUPLEX ABOVE COUNTER <br />TV <br />LOW VOLTAGE KEYED NOTES <br />TV (CATV). PROVIDE OUTLET (1) RG6. RUN CABLE TO THE CATV BOX. VERIFY WITH <br />TV SERVICE PROVIDER AND IT CONSULTANT BEFORE ROUGH-IN. <br />COMBINATION PHONE AND DATA. PROVIDE (1) CAT 6 CABLE PHONE AND (1) CAT6 <br />CABLE FOR DATA BACK TO STRUCTURED MEDIA ENCLOSURE. PROVIDE 2-PORT <br />COVER PLATE MOUNTED WITHIN 2-FEET OF 120V RECEPTACLE. <br />PHONE. PROVIDE (1) CAT 6 CABLE PHONE BACK TO STRUCTURED MEDIA <br />ENCLOSURE. PROVIDE 1-PORT COVER PLATE MOUNTED +42" AFF. <br />DATA. PROVIDE (1) CAT 6 CABLE BACK TO STRUCTURED MEDIA ENCLOSURE. <br />PROVIDE 1-PORT COVER PLATE MOUNTED 2-FEET OF 120V RECEPTACLE. <br />STRUCTURED MEDIA ENCLOSURE. COORDINATE WITH LOW VOLTAGE <br />CONTRACTOR. PROVIDE DUPLEX RECEPTACLE OUTLET INSIDE ENCLOSURE, <br />SURGE PROTECTED 15 AMP I.E. LEGRAND 5362WSP OR LEVITON 47605-ACS. <br />IN-BOUND SERVICES SHALL TERMINATE IN THIS ENCLOSURE AND INDIVIDUAL <br />CONNECTIONS SHALL BE PROVIDED TO TELEVISION, DATA AND TELEPHONE <br />DEVICES. PROVIDE CONDUIT RUN FROM THE STRUCTURED ENCLOSURE TO THE <br />TELEPHONE AND CABLE COMPANY "POC". <br />VACANCY SENSOR(WALL)VS <br />SINGLE LINE DIAGRAM <br />DUPLEX RECEPTACLE, CONTROLLEDC <br />SYMBOLS LIST <br />1 <br />WP
The URL can be used to link to this page
Your browser does not support the video tag.