Laserfiche WebLink
MAIN UTILITY METER (240\4 <br />GREEN SOURCE SOLUTION, <br />LLC <br />BUS BAR RATING <br />100 AMPS <br />22325 WYANDOTTE ST <br />CANOGA PARK, CA 91303 <br />PROVIDE NEW <br />CIRCUIT BREAKER 7 <br />2 POLE 20 AMP \ <br />100 AMP MAIN 111 <br />CIRCUIT BREAKER .3'Tr,9 Re,CR <br />LIC. # 862304 0 6 -04# E <br />ISSUE DATE 3!3STRU <br />+ <br />6 QTY. <br />SUNPOWER <br />E20-327 <br />MODULES <br />IN SERIES <br />\ BACKFEED CALCS PER NEC690 <br />.. <br />. I <br />I . . . EXISTING 100A MAIN PANEL <br />100A X 1.2 = 120A - 100A MAIN BREAKER <br />= 20A MAX PV BACKFEED PER NEC690 <br />SUNPOWERDCPOWERONE 30A NON-FUSED SPR-3000p (240V)DISCONNECT ,/VI-3.0-OUTD-S-US-A AC DISCONNECT EXISTING GROUND ROD INVERTER SPECS <br />SWITCH /240V SWITCH _ MAX MAX OUTPUT- Pmax =(LOCKABLE) - INPUT VOLTAGE VOLTAGE <br />3000 W =600 V DC =240V AC <br />#8 AWG ARMOURED GROUND -NEW / EXISTING GROUND ROD : MAX OUTPUT <br />AMPS = 14.5A <br />5/8" X 10' <br />0 <br />9 1 L_N <br />4 QTY. <br />SUNPOWER <br />E20-327 <br />MODULES <br />IN SERIES <br />- - JUNCTION <br />BOX <br />t> <br />2/22/2014 <br />REV.:DATE:-DESCRIPTION:-BY <br />PROJECT INFORMATION <br />10 SUNPOWER <br />E20-327 <br />SOLAR MODULES <br />& <br />1 PVI-3.0.-OUTD-S-US-A <br />INVERTER <br />E REQUI <br />MECHAP <br />.s must be <br />o make 8 <br />Iten permi <br />Decificatie <br />ial of the <br />4 State Le <br />n <br />TA ANA <br />NOTES: <br />1. SYSTEM CONSISTS OF 1 PARALLEL <br />STRING OF 6 MODULES WIRED IN <br />SERIES (MPPT1), AND 1 PARALLEL <br />STRING OF 4 MODULES WIRED IN <br />SERIES (MPPT2) <br />DC CONTINUOUS CURRENT: <br />ARRAY 1&2 <br />ISC X 156% = 6.46 A X 1.56 = 10.09 AMPS <br />AC CONTINUOUS CURRENT AND OCPD SIZING: <br />(INVERTER OUTPUT CURRENT) X 125% <br />PVI-3.0-OUTD-S-US-A INVERTER <br />14.5 AX1.25 = 18.12 AMPS <br />(OVERCURRENT DEVICE) >>> 20 AMP BREAKER / FUSE <br />ROOF MOUNTSUNPOWER <br />SPR-327NE-WHT-D MODULE <br />SPECS COMP. SHINGLE <br />DC AND AC CONDUCTOR SIZING <br />(AMBIENT TEMP.) + (NEC 310.15(B)(2)(c) TEMP. ADJUSTMENT)Pmax = 327 W VMP = 54.7 V IMP = 5.98 A <br />110 DEGREE FAHRENHEIT + 40 DEGREES FAHRENHEIT DRAWN BY: - CHK.: - APV.:- <br />= 150 DEGREES FAHRENHEIT =.58 (DERATION FACTOR) <br />VOC = 64.9 V ISC = 6.46 A WV <br />DC SIDE: #10 @ 40A <br />CONDUIT FILL = 0.8 <br />40 x .58 x .8 = 18.56 A CLIENT INFORMATION <br />18.56A > 10.09A ARRAY <br />DC CONDUCTOR SIZE = #10 AWG THWN-2 -IV CURVE ANGEL <br />TORO <br />AC SIDE: #10 @ 40A Pmax VMP = 328.2V IMP = 5.98 A40 x.87 = 34.8 A - =3.27 kW 2230 COTTER ST34.8A > 18.12A <br />SANTA ANA, CACONDUCTOR SIZE = #10 AWG THWN VOC x 1.14 <br />= 443.9 V ISC = 6.46 A 92706 <br />PHOTOVOLTAIC <br />SOLAR SYSTEM <br />MAX <br />TAG RATED RATED CURRENT <br />VOLTAGE AMPS 690.8(A) <br />*1.25 OR *1.56 <br />NO. OF DESCRIPTION OR CONDUCTOR COND. GAUGE COND AMP TEMP. <br />PARALLEL TYPE ff 310.15(B)(16)}RATING CORRECTION OF <br />CIRCUITS NO. OF CURRENT 90*C (194*F) COPPER {T 310.15(B)(16)}CONDUCTOR <br />CARRYING CONDUCTORS {T 690.31(c)} <br />CONDUIT FILL ADJUSTED COND. <br />DERATING FACTOR RATING <br />ff 310.15(B)(2)} <br />OCPD CONDUIT CONDUIT TYPE SHEET TITLE <br />SIZE <br />SINGLE LINE <br />443.9V 6.46A 10.09A 1 2 USE-2 FACTORY CABLES 10 AWG 40A .58 .8 17.36A N/A N/A N/A <br />N/A N/A N/A N/A <br />1 BARE COPPER <br />SYSTEM GROUNDING COND.8 AWG N/A N/A N/A N/A N/A N/A N/A <br />SHEET NUMBER <br />443.9V 6.46A 10.09A 1 4 THWN-2 (CONDUIT)(4) 10 AWG 40A .58 .8 ' 18.56A N/A 3/4"EMT SHEET NUMBER(1) 8 AWG GROUND <br />240V 14.5A 18.12A 1 3 THWN-2 (CONDUIT)(3) 10 AWG <br />(1) 8 AWG GROUND 40A .87 N/A 34.8A 20A/2P 3/4"EMT E 2 <br />. <br />I. <br />4 .