Laserfiche WebLink
ONLY <br />EV CHARGING <br />ONLY <br />EV CHARGING <br />NO PARKING <br />SEBSEBSEB <br />SEBSEBSEB <br />SEB <br />(BM <br />1 <br />0 <br />0 <br />. <br />0 <br />0 <br />) <br />99.77 <br />100.11 <br />100.00 <br />NO PARKING <br />NO <br />PARKING <br />NO <br />PARKING <br />RS RS <br />RS <br />NO <br />PA <br />R <br />K <br />I <br />N <br />G <br />LP <br />BO <br />BO <br />LP <br />RS <br />RS <br />RS <br />NO <br />PA <br />R <br />K <br />I <br />N <br />G <br />NO <br />PA <br />R <br />K <br />I <br />N <br />G <br />NO <br />PA <br />R <br />K <br />I <br />N <br />G <br />NO <br />PA <br />R <br />K <br />I <br />N <br />G <br />NO <br />PA <br />R <br />K <br />I <br />N <br />G <br />NO <br />PA <br />R <br />K <br />I <br />N <br />G <br />NO <br />PA <br />R <br />K <br />I <br />N <br />G <br />LP <br />FIP <br />EPB <br />PIV <br />WV <br />IVAIVA <br />LP <br />EPB <br />IVA <br />LP <br />EPB <br />CVA <br />WV <br />IVA <br />CVA <br />RS <br />EXISTING SOLAR CANOPY <br />EXISTING SOLAR CANOPY <br />EXISTING SCE <br />TRANSFORMER, <br />P5510319 <br />NO <br /> <br />P <br />A <br />R <br />K <br />I <br />N <br />G <br />NO <br /> <br />P <br />A <br />R <br />K <br />I <br />N <br />G <br />AL <br />AL <br />ALET <br />EPB <br />EXISTING <br />INVERTER <br />MOUNTED <br />ON I-BEAM <br />(TYP) <br />CPB <br />W <br />W <br />W <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E E E E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E E E <br />E <br />E <br />E <br />E <br />E <br />E E <br />E <br />E <br />E <br />E E E <br />SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD <br />E <br />E <br />E <br />UNK <br />UNK <br />UN <br />K <br />UN <br />K <br />UN <br />K <br />UNK <br />UN <br />K <br />C <br />C <br />C C C <br />C <br />C <br />C <br />C <br />C <br />C <br />C <br />C <br />C <br />C <br />C <br />C C <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />IR <br />R <br />IR <br />R <br />IR <br />R <br />IR <br />R <br />IRR IRR <br />IRR <br />IRR <br />IRR IRR IRR IRR <br />IR <br />R <br />IR <br />R <br />IR <br />R <br />IR <br />R <br />IR <br />R <br />IRR <br />IR <br />R <br />UNK <br />UNK <br />UNK <br />UNK <br />UNK <br />UNK <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />E <br />SD <br />SD <br />W W W W W <br />E E E E E E E <br />E <br />E <br />C <br />C <br />C <br />C <br />C <br />C <br />C <br />C <br />1 <br />2 <br />5 <br />6 <br />910 <br />8 <br />7 <br />4 <br />3 <br />11 <br />12 <br />13 <br />14 <br />15161718 <br />1920 <br />EVSE-1EVSE-2 <br />EVSE-3 <br />EVSE-4 <br />EVSE-5 <br />EVSE-6EVSE-7 <br />EVSE-8 <br />EVSE-9 <br />EVSE-10 <br />EVSE-11 <br />(K1-K5, C2) <br />(K1-K4, C1-C2) <br />(K1,K2, C2) <br />(K5) <br />T <br />SCE TRANSFORMER, 12KV, <br />150KVA, 208Y/120V, 3Ø, 4W <br />(K6-K12, <br />C1) <br />(K8-K12, <br />C1) <br />(K9,K11, <br />K12, C1) <br />(K7-K12, <br />C1) <br />(K9,K11)(K12, <br />C1) <br />(P1,P2) <br />(K13, C1-C2) <br />A <br />B C <br />C <br />E <br />H <br />(TYP) <br />(K10) <br />(TYP) <br />(TYP) <br />F <br />D <br />(TYP) <br />(K1, C2) <br />G <br />SHEETSOF <br />SHEET NO. <br />SCALE AS NOTED <br />DATE: <br />CH. BY: <br />DR. BY: <br />REF. & REV. <br />CONSULTANT <br />06-17-2025 12 <br />CR <br />GSKAISER FOUNDATION HEALTH PLAN <br />CHARGE READY PROGRAM <br />SOUTHERN CALIFORNIA EDISON <br />Dr <br />a <br />w <br />i <br />n <br />g <br />: <br /> <br />P: <br />\ <br />2 <br />2 <br />1 <br />\ <br />2 <br />2 <br />1 <br />- <br />0 <br />2 <br />2 <br />3 <br />\ <br />S <br />i <br />t <br />e <br />\ <br />0 <br />0 <br />0 <br />0 <br />2 <br />1 <br />1 <br />2 <br />3 <br />0 <br />9 <br />_ <br />K <br />F <br />H <br />P <br />\ <br />C <br />D <br /> <br />P <br />h <br />a <br />s <br />e <br />\ <br />P <br />r <br />o <br />d <br />u <br />c <br />t <br />i <br />o <br />n <br />D <br />r <br />a <br />w <br />i <br />n <br />g <br />s <br />\ <br />21 <br />1 <br />2 <br />3 <br />0 <br />9 <br />_ <br />K <br />F <br />H <br />P <br />_ <br />e <br />l <br />0 <br />1 <br />. <br />d <br />w <br />g <br />; <br />La <br />y <br />o <br />u <br />t <br />1 <br /> - <br /> <br />BC <br />F <br />. <br />c <br />t <br />b <br />Pl <br />o <br />t <br /> <br />b <br />y <br />: <br /> <br />dp <br />a <br />r <br />t <br />i <br />d <br />a <br /> <br /> <br />Oc <br />t <br /> <br />2 <br />3 <br />, <br /> <br /> <br />2 <br />0 <br />2 <br />5 <br /> <br />- <br /> <br />1 <br />: <br />5 <br />6 <br />p <br />m <br />00002112309 <br />Date Signed: <br />06-17-2025 <br />PROJECT LOCATION: 3401 S HARBOR BLVD., SANTA ANA, CA 92704 <br />6 <br />ELECTRICAL CONDUIT PLAN <br />E1.0 <br />SCALE IN FEET <br />0 5 10 20 <br />SCALE: 1"=10' <br />ELECTRICAL LEGEND: <br />FURNISH AND INSTALL SERVICE CT METER AND MAIN SWITCHBOARD <br />PER DETAILS [A/E2.0], [A/E3.0], AND [C/E3.0] <br />FURNISH AND INSTALL POWERFLEX NEXUS CORE TERMINAL BOX <br />PER DETAILS [C/E2.0] AND [E/E2.0] <br />SEE DETAIL [B/E2.0] FOR THE FURNISHING AND INSTALLATION OF <br />BELOW GRADE PVC CONDUIT. SEE CONDUIT SCHEDULE FOR COUNT <br />AND CONDUIT SIZE <br />FURNISH AND INSTALL TEMPORARY TERMINAL BLOCK AND <br />APPURTENANCES FOR EV CHARGER PEDESTALS. CONSTRUCT PER <br />DETAIL [B/E2.1] <br />FURNISH AND INSTALL TEMPORARY TERMINAL BOX AND <br />APPURTENANCES FOR PAYMENT KIOSK. CONSTRUCT PER DETAILS <br />[C/E2.0] AND [A/E2.1] <br />FURNISH AND INSTALL TEMPORARY TERMINAL BLOCK AND <br />APPURTENANCES FOR EV CHARGER PEDESTALS WITH ADDED <br />WIRELESS ACCESS POINT. CONSTRUCT PER DETAIL [B/E2.1] <br />FURNISH AND INSTALL (JENSEN PRECAST) 11"X17"X12"D CLOSED <br />BOTTOM FLAT WALL PULL BOX WITH TRAFFIC RATED SECURITY <br />BOLTED MARKED "ELECTRIC" COVER. GROUT SEAL CONDUIT <br />PENETRATIONS AND SEAL CONDUITS WITH DUCT SEAL OR EQUAL <br />TO PREVENT WATER ENTRY. SEE DETAIL [E/E2.0] <br />GROUND ROD 12" (MIN) BELOW SURFACE <br />PROPOSED SERVICE CT METER AND MAIN SWITCHBOARD <br />POWERFLEX NEXUS CORE. TO BE INSTALLED BY OTHERS. (SHOWN <br />FOR REFERENCE ONLY) <br />PAYMENT KIOSK. TO BE INSTALLED BY OTHERS. (SHOWN FOR <br />REFERENCE ONLY) <br />GROUND ACCESS WELL AND 5/8" X 8' COPPER CLAD GROUND ROD <br />SOUTHERN CALIFORNIA EDISON ELECTRICAL TRANSFORMER, BY <br />T&D <br />(SHOWN FOR REFERENCE ONLY) <br />PROPOSED LITEON SC48 DUAL CHARGE PORT STYLE CHARGERS TO <br />BE INSTALLED BY OTHERS. SEE DETAILS [A/R1.0], [B/R1.0], [D/R1.0], <br />AND [E/R1.0] (SHOWN FOR REFERENCE ONLY) <br />PROPOSED LITEON SC48 SINGLE CHARGE PORT STYLE CHARGERS <br />TO BE INSTALLED BY OTHERS. SEE DETAILS [A/R1.0], [B/R1.0], <br />[C/R1.0], AND [E/R1.0] (SHOWN FOR REFERENCE ONLY) <br />BURIED BARE COPPER GROUND WIRE <br />ELECTRICAL CONDUIT; SIZE AND COUNT AS NOTED <br />SOUTHERN CALIFORNIA EDISON ELECTRICAL SERVICE SUPPLY TO <br />METER, BY T&D <br />(SHOWN FOR REFERENCE ONLY) <br />A <br />B <br />C <br />D <br />E <br />F <br />G <br />H <br />T <br />CONDUIT SCHEDULE <br />CONDUIT <br />NUMBER FROM TO CONDUCTORS ALL 90°C THWN-2 OR <br />SIMILAR UNLESS NOTED OTHERWISE <br />CONDUCTOR <br />LENGTH (FT)VOLTAGE DROP CONDUIT <br />SIZE/TYPE COMMENTS <br />P1 PROPOSED SCE TRANSFORMER SERVICE CT METER AND MAIN <br />SWITCHBOARD PER SCE --4" PVC <br />P2 PROPOSED SCE TRANSFORMER SERVICE CT METER AND MAIN <br />SWITCHBOARD PER SCE --4" PVC <br />K1 SERVICE CT METER AND MAIN <br />SWITCHBOARD <br />EVSE-1 <br />(CHARGE PORTS 1 & 2) <br />SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED <br />EVSE-1, CHARGE PORTS 1 & 2 (L1,L2,GND)92 2.2%1" PVC <br />K2 SERVICE CT METER AND MAIN <br />SWITCHBOARD <br />EVSE-2 <br />(CHARGE PORTS 3 & 4) <br />SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED <br />EVSE-2, CHARGE PORTS 3 & 4 (L1,L2,GND)91 2.2%1" PVC <br />K3 SERVICE CT METER AND MAIN <br />SWITCHBOARD <br />EVSE-3 <br />(CHARGE PORTS 5 & 6) <br />SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED <br />EVSE-3, CHARGE PORTS 5 & 6 (L1,L2,GND)75 1.8%1" PVC <br />K4 SERVICE CT METER AND MAIN <br />SWITCHBOARD <br />EVSE-4 <br />(CHARGE PORTS 7 & 8) <br />SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED <br />EVSE-4, CHARGE PORTS 7 & 8 (L1,L2,GND)74 1.8%1" PVC <br />K5 SERVICE CT METER AND MAIN <br />SWITCHBOARD <br />EVSE-5 <br />(CHARGE PORTS 9 & 10) <br />SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED <br />EVSE-5, CHARGE PORTS 9 & 10 (L1,L2,GND)80 1.9%1" PVC <br />K6 SERVICE CT METER AND MAIN <br />SWITCHBOARD <br />EVSE-6 <br />(CHARGE PORTS 11 & 12) <br />SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED <br />EVSE-6, CHARGE PORTS 11 & 12 (L1,L2,GND)34 0.8%1" PVC <br />K7 SERVICE CT METER AND MAIN <br />SWITCHBOARD <br />EVSE-7 <br />(CHARGE PORTS 13 & 14) <br />SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED <br />EVSE-7, CHARGE PORTS 13 & 14 (L1,L2,GND)38 0.9%1" PVC <br />K8 SERVICE CT METER AND MAIN <br />SWITCHBOARD <br />EVSE-8 <br />(CHARGE PORTS 15 & 16) <br />SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED <br />EVSE-8, CHARGE PORTS 15 & 16 (L1,L2,GND)52 1.3%1" PVC <br />K9 SERVICE CT METER AND MAIN <br />SWITCHBOARD <br />EVSE-9 <br />(CHARGE PORTS 17 & 18) <br />SOUTHWIRE (4) #8, (2) #8 GRN GROUND, TAGGED <br />EVSE-9, CHARGE PORTS 17 & 18 (L1,L2,GND)66 1.6%1" PVC <br />K10 SERVICE CT METER AND MAIN <br />SWITCHBOARD <br />EVSE-10 <br />(CHARGE PORT 19) <br />SOUTHWIRE (2) #8, (1) #8 GRN GROUND, TAGGED <br />EVSE-10, CHARGE PORT 19 (L1,L2,GND)61 1.5%1" PVC <br />K11 SERVICE CT METER AND MAIN <br />SWITCHBOARD <br />EVSE-11 <br />(CHARGE PORT 20) <br />SOUTHWIRE (2) #8, (1) #8 GRN GROUND, TAGGED <br />EVSE-11, CHARGE PORT 20 (L1,L2,GND)69 1.7%1" PVC <br />K12 SERVICE CT METER AND MAIN <br />SWITCHBOARD PAYMENT KIOSK SOUTHWIRE (2) #12, (1) #12 GRN GROUND, <br />TAGGED (L1,L2,N,GND)66 0.9%1" PVC <br />K13 SERVICE CT METER AND MAIN <br />SWITCHBOARD POWERFLEX NEXUS CORE SOUTHWIRE (2) #12, (1) #12 GRN GROUND, <br />TAGGED (PFLMC,L1,N,GND)25 0.3%1" PVC / RMC <br />C1 POWERFLEX NEXUS CORE PAYMENT KIOSK SHIELDED CAT6 CABLE 71 -1" PVC COMMUNICATION TO <br />POWERFLEX SYSTEM <br />C2 POWERFLEX NEXUS CORE POWERFLEX WIFI ACCESS <br />POINT SHIELDED CAT6 CABLE 78 -1" PVC <br />A <br />E1.0 <br />CONDUIT SCHEDULE <br />ELECTRICAL NOTES: <br />1.ELECTRICAL UTILITY LINE TO BE PROTECTED IN PLACE WHEN POSSIBLE. IF <br />EXISTING LINES INTRODUCE EXCESSIVE CONSTRAINTS DURING THE <br />INSTALLATION OF THE ELECTRICAL EQUIPMENT, REMOVE AND RELOCATE <br />EXISTING LINES AS NEEDED, USING THE PROPOSED UTILITY TRENCH. IF THE <br />ELECTRICAL LINE CANNOT BE SALVAGED THE CONTRACTOR MUST <br />LAWFULLY DISPOSE OF THE ELECTRICAL LINE AND REPLACE WITH <br />LIKE-IN-KIND. <br />2.ALL ELECTRICAL POWER IN CLOSE PROXIMITY TO THE INSTALLATION OF <br />THE ELECTRICAL EQUIPMENT MUST BE POWERED OFF PRIOR TO THE <br />START OF CONSTRUCTION, TO PREVENT ANY ELECTRICAL INJURIES. <br />3.HAND DIG ALL UTILITIES IN CLOSE PROXIMITY TO THE INSTALLATION OF THE <br />ELECTRICAL EQUIPMENT TO AVOID DAMAGING ANY UTILITY LINE. <br />4.SEE SINGLE LINE DIAGRAM ON SHEET E3.0. <br />5.SEE CONDUIT SCHEDULE ON SHEET FOR WIRE SIZE, CONDUIT FILL AND <br />WIRE TAGS. <br />6.THE METHODS CONTAINED IN CEC/NEC ARTICLE 250 SHALL BE FOLLOWED <br />TO COMPLY WITH GROUNDING AND BONDING OF ELECTRICAL SYSTEMS <br />AND NON-CURRENT CARRYING CONDUCTIVE MATERIALS, ENCLOSURES, OR <br />ITEMS FORMING PART OF ANY SUCH EQUIPMENT THAT ENCLOSES OR <br />CARRIES ELECTRICAL CONDUCTOR OR EQUIPMENT THAT IS LIKELY TO <br />BECOME ENERGIZED. SEE CEC/NEC 250.4(A)(1) THROUGH (5) FOR FURTHER <br />DESCRIPTION. <br />7.WHERE TWO OR MORE GROUND RODS ARE TO BE INSTALLED, THE MINIMUM <br />SEPARATION SHALL BE 6' PER CEC/NEC 250.53 (A)(2), AND (3) RESISTANCE <br />OF ELECTRODES. <br />8.MINIMUM CONDUIT BURIAL DEPTH SHALL BE 24". <br />9.PER CEC/NEC 110.26 "ACCESS AND WORKING SPACE SHALL BE PROVIDED <br />AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO PERMIT READY <br />AND SAFE OPERATION AND MAINTENANCE OF SUCH EQUIPMENT." <br />10.CONDUIT BODIES SHALL BE USED AS NEEDED TO MAINTAIN LESS THAN 360° <br />OF CONDUIT BENDS BETWEEN PULL POINTS. <br />11.CONDUIT ROUTING AND DETAILS SHOWN IN PLANS ARE DIAGRAMMATIC <br />ONLY. FINAL CONDUIT INSTALLATION MAYBE FIELD FIT AS NEEDED. <br />12.FINAL LOCATION OF POWERFLEX WIRELESS ACCESS POINT MAY BE FIELD <br />FIT, AND ADDITIONAL WIRELESS ACCESS POINTS MAY BE ADDED AS <br />NEEDED, TO ENSURE CONNECTIVITY AND CONTINUITY OF CHARGER <br />NETWORK. SEE DETAIL [D/R1.1]