Laserfiche WebLink
THE DOT PRINTER <br />2525 Pullman Street <br />Santa Ana, CA <br />THE DOT PRINTER <br />12/2/2025 <br />1/20"= 1'-0" <br />G-2 <br />71 <br />4 <br />- <br />5 <br />7 <br />2 <br />- <br />4 <br />4 <br />1 <br />0 <br />co <br />m <br />p <br />l <br />y <br />@ <br />c <br />o <br />m <br />p <br />l <br />i <br />a <br />n <br />c <br />e <br />f <br />i <br />r <br />s <br />t <br />. <br />c <br />o <br />m <br />10 <br />5 <br />7 <br /> <br />E <br />. <br /> <br />I <br />m <br />p <br />e <br />r <br />i <br />a <br />l <br /> <br />H <br />w <br />y <br />. <br />Pl <br />a <br />c <br />e <br />n <br />t <br />i <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />7 <br />0 <br />Co <br />m <br />p <br />l <br />i <br />a <br />n <br />c <br />e <br /> <br />F <br />i <br />r <br />s <br />t <br />, <br /> <br />I <br />n <br />c <br />. <br /> R <br />A <br />C <br />K <br /> <br />S <br />T <br />O <br />R <br />A <br />G <br />E <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br />NOTES: GENERAL FIRE DEPARTMENT <br />1) Fire Department Final Inspection required. Scheduled inspection 2 Days in Advance. <br />2) Installation and Modifications of the Fire Sprinkler System Shall Be 2022 NFPA 13 Compliant, Plans To Be Submitted <br />Separately By A Contractor and Subject To Approval Prior To Installation. <br />3) Any Plans and Calculations for Sprinkler Modification Shall Be Submitted By A Contractor and Subject To Approval <br />Prior To Installation. <br />4) Location and Classification of Extinguishers Shall Be In Accordance With The 2022 CFC Section 906.The fire <br />extinguisher must be located in visible and accessible location. The location of the fire extinguisher must be chosen to <br />minimize damage from forklift traffic and merchandise handling. <br />5) Address Numbers Shall Be A Minimum Of 8" High And Plainly Visible From The Roadway. <br />6) Exit Door's Swing In Direction of Egress and Are Equipped With "No Knowledge" Hardware. <br />7) Private Fire Hydrants Sprinkler Controls and Post Indicator and Risers To Fire Department Shall Be Painted Red. <br />8) The door sizes for the Fire Department access doors. Per the 2022 CFC 3206.7.6, the minimum access door size shall <br />be 3'-0" X 6'-8". <br />9) For High Piled Storage Stock/Racking Area Exceeding 500 sq. ft. Plans To Be Submitted Separately To The Local Fire <br />Department and Subject To Approval Prior To Installation. Shall Comply with All Applicable Fire Codes. <br />10) OCFA Approval is Required Prior to Building Approval. <br />NOTES: BUILDING <br />A) Commodities Stored: <br />The company is a warehouse storage facility that houses electronics (such as microphones, headsets, monitors, <br />gaming controllers, earbuds, radio control cars, etc.), clothing made of cotton/synthetic cloth, pool displays, swimming fins <br />made of silicone/rubber, cleaning supplies, and other similar items. <br />1. Construction Type III-B. <br />2. Occupancy Classification S-1,B. <br />3. Existing Automatic Sprinkler System NFPA, 13 Compliant. <br />4. The owner shall maintain the structural integrity of the rack system by assuring proper operational, house keeping, and <br />maintenance procedures, but not limited to, the following: <br />a) Prohibit any over loading of any pallet positions and of the overall rack system. <br />b) Regularly inspect for damage. If damage is found, immediately unload the affected area and replace or repair any <br />damaged columns, beams, or other structural components. <br />c) Require all pallets to be maintained in good, safe, operating condition. <br />d) Ensure that pallets are properly placed onto pallet load support members in properly stacked and stable position. <br />e) When applicable require that all goods stored on each pallet to be properly stacked and stable. <br />f) Prohibit double stacking of any pallet position, including the top most position, unless the rack system is specifically <br />designed for such loading. <br />5. Aisles Widths Shall Be In Accordance with CFC 2022 3206.10.1.1 & 3206.10.1.2 The minimum aisle widths are 48 <br />inches. <br />6.CFC 2022 Chapter 10, 1001.1 General. Buildings or portions thereof shall be provided with a means of egress system <br />as required by Chapter 10 MEANS OF EGRESS. <br />7. Illuminated Lighting. <br />8. There are not stairways/platforms connected to Racking. <br />9. Storage Racks Not Open to The Public In Warehouse. <br />NOTES: MEANS OF EGRESS/EXITS <br />A) Means of Egress Continuity Shall Be In Accordance With 2022 CFC 1003.6. The Path of Egress Travel Along a <br />Means of Egress Shall Not Be Interrupted by Any Building Element Other Than The Means of Egress Component As <br />Specified. Obstructions Shall Not Be Placed In the Required Width of A Means of Egress. The Required Capacity of A <br />Means of Egress System Shall Not Be Diminished Along The Path of Egress. <br />B) Where required CFC 2022 1013.1 Exits and exit access doors shall be marked by an approved exit sign readily visible <br />from any direction of egress travel. The path of egress travel to exits and within exits shall be marked by readily visible <br />exit signs to clearly indicate the direction of egress travel in cases where the exit or the path of egress travel is not <br />immediately visible to the occupants. Intervening means of egress doors within exits shall be marked by exit signs. Exit <br />sign placement shall be such that any point in an exit access corridor or exit passageway is within 100 feet (30 480 mm) <br />or the listed viewing distance of the sign, whichever is less, from the nearest visible exit sign. <br />C) 2021 NFPA 101, Section 7.10.1.8. Signs must be located in such a location and be of such a size, distinctive color, <br />and design that they are readily visible. All signs must also provide contrast with decorations, interior finish, or other signs, <br />and may not be blocked by decorations, furnishings, or equipment that impairs visibility of a sign. Further, no brightly <br />illuminated sign, display, or object that could detract from an Exit sign are permitted in or near the line of vision of an Exit <br />sign. <br />D) 2021 NFPA 101, Section 7.10.5.1. Every sign required for Exit or Exit access--other than those where operations or <br />processes require low lighting levels--must be suitably illuminated by a reliable light source. Externally and internally <br />illuminated signs must be legible in both normal and emergency lighting mode. <br />E) 2021 NFPA 101, Section 7.10.8.3.1. All doors, passages or stairways that are neither an exit nor a way of exit <br />access--yet are likely to be mistaken for an exit--be identified with a "No Exit" sign. <br />F) CFC 2022, Section 1008.3.4 Duration of Emergency Power. The emergency power system shall provide power for a <br />duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The <br />installation of the emergency power system shall be in accordance with Section 2702 of the California Building Code. <br />G) 2021 NFPA 101, Section 7.10.7.2. Photoluminescent Signs. The face of a Photoluminescent sign shall be continually <br />illuminated while the building is occupied. The illumination levels on the face of the Photoluminescent sign shall be in <br />accordance with its listing. Recharging illumination shall be a reliable light source as determined by the authority having <br />jurisdiction. The charging light source shall be of a type specified in the product markings. <br />H) The installation of storage racks shall meet the CBC requirements of the means of egress for exit signs, egress <br />illumination, and emergency power systems. These are to be verified by the field inspector, who may require plans <br />showing compliance of such items. Additional permit(s) may be required for means of egress added improvements. <br />I) Exit access travel distance, measured from the most remote point to an exit, not to exceed the allowable distance per <br />CBC Table 1017.2. Building Equipped with an NFPA 13 Compliant Sprinkler System. <br />Rack Storage - Floor Plan <br />According To 2022 CBC <br />Note: Conditions of adhering to this plan are the sole responsibility of the <br />Owner/Tenant. If modifications to the building are conducted it is the <br />Owner/Tenant's responsibility to obtain a licensed contractor to perform such <br />work along with any necessary plan submittals to the local agencies for approval <br />of permits. <br />The Company acknowledges that it is the responsibility of <br />“THE DOT PRINTER” to contact “Building” to conduct a “Final <br />Inspection” for sign-off of the “Approved Plan.”N <br />Office <br />Areas <br />EXIT <br />ACCESS <br />EXIT <br />ACCESS <br />EXIT <br />ACCESS <br />EXIT <br />ACCESS <br />EXIT <br />ACCESS <br />EXIT <br />ACCESS <br />EXIT <br />ACCESS <br />EXIT <br />ACCESS <br />EXIT <br />ACCESS <br />Warehouse Area <br />± 96,300 Sq.Ft. <br />RISERS WITH <br />ALARM VALVES RISER WITH <br />ALARM VALVE <br />5'-3" <br />4'-0" <br />2' <br />- <br />4 <br />3 <br />16 <br />" <br />EXIT PATH 245' <br />2'-3" <br />5'-6" <br />10'-0"9'-9" <br />9'-6"9'-6"9'-6"9'-6"9'-6" <br />9'-6" <br />1'-6" <br />9'-9"10'-0"6'-0"10'-0" <br />9'-6"9'-6"9'-6"9'-6"9'-6" <br />8'-4"2'-3" <br />2' <br />- <br />3 <br />" <br />18 <br />0 <br />' <br />- <br />0 <br />" <br />65'-5" <br />11 <br />2 <br />' <br />- <br />1 <br />" <br />56'-11" <br />10 <br />' <br />- <br />1 <br />1 <br />" <br />EXIT PATH 181' <br />EXITEXIT <br />EXITEXIT <br />EXITEXIT <br />EX <br />I <br />T <br />EX <br />I <br />T <br />EX <br />I <br />T <br />EX <br />I <br />T <br />EXITEXIT <br />EXITEXIT <br />EX <br />I <br />T <br />EX <br />I <br />T <br />12/2/25 <br />(6)6,2 251$3 /'((15*(7 ,16,(*((55 <br />$&/),)2 2(571$,7 $6 9 ,,/& <br />((55 <br />$&/),)2 2(555555555555555555555555555555555555555555555555555555555777777777777777777777777777777777777777777777777111111111111111111111111111111111111111111111111111111111$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$7 ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,7$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$66666666666666666666666666666666666666666666666 <br />1R1R <br />(([S[S7 <br />THE P.E. CERTIFICATION PROVIDED HEREIN PERTAINS <br />TO THE ADEQUACY OF THE STORAGE RACK <br />STRUCTURAL COMPONENTS ONLY. ALL <br />OTHER AREAS ARE OUTSIDE THE SCOPE OF <br />WORK OF THIS CERTIFICATION. .