My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1501 N Ross St-REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Ross St
>
1501 N Ross St
>
1501 N Ross St-REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2026 5:00:11 AM
Creation date
1/27/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
20185807
101123623
Full Address
1501 N Ross St
Street Number
1501
Street Direction
N
Street Name
Ross
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
STRUT CONDUIT CLAMP <br />12 GA GALVANIZED <br />STEEL <br />SIZED AS APPROPRIATE <br />1-5/8" STRUT CHANNEL <br />12 GA, HDG <br />NOTE: ALL HOLES FOR CONDUIT SHALL BE PROVIDED WITH CONDUIT FITTINGS <br />HAVING AN ENVIRONMENTAL RATING APPROVED TO MAINTAIN NEMA 3R <br />ENCLOSURE RATING (UL508A, TABLE 19.2). IN GENERAL COMPONENTS MARKED <br />"WEATHERPROOF" OR "RAINPROOF" SHALL BE INSTALLED ONLY BELOW THE <br />LOWEST UNINSULATED LIVE PARTS WITHIN THE ENCLOSURE. CONDUIT <br />OPENINGS ABOVE THE LOWEST UNINSULATED LIVE PARTS SHALL BE PROVIDED <br />WITH CONDUIT FITTINGS MARKED "WET LOCATION" OR "RAINTIGHT". <br />WOOD: MIN. 2" EMBED W/ 3/8" LAG TO <br />(E) STUD OR 4"xBLOCK W/ A34 EA. <br />END T&B <br />MASONRY: USE ICC-APPROVED <br />MASONRY ANCHORS <br />STEEL: USE SELF-DRILLING, <br />SELF-TAPPING SCREWS <br />OPTION 1 OPTION 2 <br />2-HOLE 12 GA GALV <br />STEEL STRAP <br />NTS <br />CONDUIT SUPPORT - WALLC <br />USE EXISTING HOLES TO <br />TERMINATE CONDUCTORS, <br />TORQUE PER <br />MANUFACTURER <br />REQUIREMENTS. USE <br />GRADE 5 OR LARGER BOLT. <br />UL LISTED CRIMP RATED FOR 600 <br />VOLTS CRIMPED IN 2 PLACES. USE <br />MANUFACTURER APPROVED <br />CRIMPING DEVICE ONLY AND <br />APPLY ANTIOXIDANT COMPOUND <br />BEFORE CRIMPING. <br />SIDE VIEWFRONT VIEW <br />(E) BUS <br />NOTE: <br />ALUMINUM CONDUCTORS SHALL NOT BE TERMINATED WITH MECHANICAL LUGS. <br />TORQUE MARK BOLT WITH PAINT <br />PEN AFTER TORQUING NUT/BOLT <br />B CONDUCTOR TERMINATION DETAIL <br />NTS <br />CONTINUOUS GROUND <br />STRIP INSULATION AT LUG <br />ENCLOSURE <br />LOCK NUT <br />GROUNDING BUSHING <br />WITH LAY-IN LUG <br />CONDUIT COMPRESSION FITTING <br />NTS <br />CONDUIT GROUNDING DETAILA <br />NOTE: <br />ACCESSIBLE MEANS EXTERNAL TO ENCLOSURES FOR <br />CONNECTING INTERSYSTEM BONDING AND GROUNDING <br />CONDUCTORS SHALL BE PROVIDED. SEE NEC 250.94. <br />SERVICE DISCONNECT 1 OF 2 SHALL BE LISTED <br />AS SUITABLE FOR SERVICE EQUIPMENT <br />WHERE NEUTRAL TERMINAL BUS IS <br />INSULATED FROM THE ENCLOSURE, <br />INSTALL A MAIN BONDING JUMPER <br />OR SCREW WITH A GREEN SEE NEC <br />250.8, 250.28. NEUTRAL DISCONNECT <br />MEANS. SEE NEC 230.75. <br />WHERE SERVICE ENTRANCE <br />RACEWAY IS INSTALLED WITH <br />LOCKNUTS, INSTALL A GROUND <br />BUSHING OR DEVICE AND BOND TO <br />THE ENCLOSURE. SEE NEC 250.92 <br />(B) (4). <br />GROUNDING ELECTRODE SYSTEM – <br />SEE NEC 250.50. <br />IF METALLIC CONDUIT, BONDING <br />REQUIRED (BOTH ENDS) SEE NEC <br />250.92. <br />GROUNDING ELECTRODE <br />CONDUCTOR – SEE NEC 250.62 <br />FOR MATERIAL, NEC 250.64 FOR <br />INSTALLATION, AND NEC 250.66 <br />FOR SIZE. <br />CONNECTION TO ELECTRODE – <br />CONNECT GROUNDING ELECTRODE <br />CONDUCTOR TO GROUNDING <br />ELECTRODE WITH LISTED GROUND <br />SEE NEC 250.70. <br />BONDING JUMPER SEE NEC <br />250.92 (A) (2). FOR SIZES, <br />SEE NEC 250.102 (C). <br />LAY IN LUG. WHERE LUG IS <br />INSULATED FROM <br />ENCLOSURE, INSTALL A <br />BONDING JUMPER OR <br />SCREW. <br />GROUNDED (NEUTRAL) SERVICE <br />ENTRANCE CONDUCTOR <br />FROM PV SYSTEM <br />SERVICE <br />DISCONNECT <br />2 OF 2 <br />METER ENCLOSURE <br />D METER GROUNDING DETAIL <br />NTS <br />C:\USERS\BSCHULZE\DESKTOP\ROSS & DURANT II\2317_ROSS&DURANTII_CAD_VB\ROSS&DURANTII_VB.DWG <br />ELECTRICAL DETAILS <br />CONTRACTOR: <br />ENGINEERING APPROVAL: <br />600 CALIFORNIA ST #1800, SAN <br />FRANCISCO, CA 94104 <br />CA CL #750184 <br />UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN <br />PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT <br />LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. <br />ROSS & DURANT II <br />1501 N ROSS ST, SANTA <br />ANA, CA 92706, USA <br />APN:005-112-07 <br />DEVELOPER: <br />C&C DEVELOPMENT <br />DESCRIPTION DATE REV <br />0ORIGINAL04/28/25 <br />ASYSTEM DOWN SIZE 07/16/25 <br />BAHJ COMMENTS 08/04/25 <br />CEQUIPMENT LOCATION 10/21/25 <br />PROJECT DETAILS: <br />PV SYSTEM: <br />·57.4 kW DC <br />·40 kW AC <br />·53.49 CEC AC <br />ENERGY STORAGE: <br />·40 kW AC <br />·116.4 kWH <br />E400 <br />SHEET SIZE: <br />REVISION: <br />SHEET TITLE: <br />36" X 24" (ARCH D) <br />DESIGNER: FINS_MK <br />C <br />CONTRACT NUMBER: <br />3003200672 <br />PJT #: PROP-002137
The URL can be used to link to this page
Your browser does not support the video tag.