t. <br />LEVIBUILDERS <br />a THE ALONZO RESIDENCE C <br />3.27 kW PHOTOVOLTAIC SYSTEM 1 x--Ae-©E*B FOR <br />ISSUE DATE <br />SHEET INDEX <br />CONSTRUCTION SHALL COMPLY WITH 2013 CBC, CMC, CPC, CEC & CRC <br />ELECTRICAL TO COMPLY WITH 2014 NEC AND INTERNATIONAL ELECTRICAL CODE <br />ROOFING INFORMATION PHOTOVOLTAIC NOTE'S <br />1 0122/2lillianst o <br />1 tvNLE <br />1 #Imm,9* <br />Tl -TITLE SHEET <br />ARCHITECTURAL <br />Al --SITE PLAN <br />ELECTRICAL <br />El -ELECTRICAL SITE PLAN <br />E2 - SINGLE LINE <br />E3 - PHOTOVOLTAIC SIGNAGE <br />STRUCTURAL <br />Sl -TYP. CONNECTION DETAILS <br />OTHER PROJECT DETAILS <br />OPD1 i, - MODULE & INVERTER SPECIFICATIONS <br />U <br />GENERAL ELECTRICAL NOTES <br />1. EQUIPMENT USED SHALL BE NEW, UNLESS <br />OTHERWISE NOTED. <br />2. EQUIPMENT USED SHALL BE UL LISTED, <br />UNLESS OTHERWISE NOTED. <br />3. EQUIPMENT SHALL BE INSTALLED PROVIDING <br />ADEQUATE PHYSICALWORKING SPACE <br />AROUND THE EQUIPMENT AND SHALL COMPLY <br />WITH NEC. <br />4. COPPER CONDUCTORS SHALL BE USED AND <br />SHALL HAVE INSULATION RATING 600V, 90 C. <br />UNLESS OTHERWISE NOTED. <br />5. CONDUCTORS SHALL BE SIZED IN ACCORD- <br />ANCE TO NEC. CONDUCTORS AMPACITY <br />SHALL BE DE-RATED FOR TEMPERATURE <br />INCREASE, CONDUIT FILL AND VOLTAGE <br />DROP. <br />6. EXPOSED NON-CURRENT'CARRYING METAL <br />PARTS SHALL BE GROUNDED AS PER NEC. <br />7. LOAD SIDE INTER-CONNECTION SHALL <br />COMPLY WITH NEC. <br />EXISTING ROOF <br />PITCH <br />W[ND SPEED <br />EXPOSURE CATEGORY <br />ARRAY INFORMATION <br />MODULE WEIGHT <br />MODULE LENGTH <br />MODULE WIDTH <br />MODULE:DEPTH <br />TOTAL MODULES <br />TOTAL ROOF AREA <br />TOTAL ARRAY AREA <br />% AREA OF PANELS <br />SUM: MODULE WEIGHT <br />SUM: MOUNTS AND RAIL WEIGHT (0.4 LB/SQ. FT.) <br />TOTAL INSTALLATION WEIGHT <br />TOTAL INSTALLATION AREA <br />DISTRIBUTION LOAD <br />PROPERTY AND CODE INF <br />PROPERTY OWNER: <br />ANTONIO ALONZO <br />PROJECT SITE: <br />2218 EVERGREEN ST <br />SANTA ANA, CA 92707 <br />OCCUPANCYGROUP R-3 <br />TYPE OF CONSTRUCTION VB <br />STGRIES 1 <br />SQ. FT.916 SQ. FI. <br />COMP. SHINGLE <br />18 DEGREES <br />110 <br />C <br />41 LBS <br />61.39' <br />41.18" <br />1.81" <br />10 <br />916 SO. FT. <br />181.65 SQ. FT. <br />19% <br />410 LBS. <br />72.66 LBS. <br />482.66 LBS. <br />181.65 SQ. FT. <br />2.65 LB@ / SQ. FT. <br />ALL MATERIALS, EQUIPMENT, INSTALLATION AND <br />WORKSHALL COMPLY W/: <br />-2013 CBC/2012 IBC <br />- 2013 CRC /2013 IRC <br />- 2013 CEC / 2014 NEC <br />- 2013 CMC / 2013 UMC <br />- 2013 CPC / 2013 UPC <br />- 2013 CFC / 2013 IFC <br />ALL EQUIPMENT SHALL BE LISTED AND <br />LABELED BY A RECOGNIZED ELECIRICAL <br />TESTING LABORATORY AND INSTALLED PER <br />LISTING REQUIREMENTS AND THE <br />MANUFACTURER'S INSTRUCTIONS. <br />ALL OUTDOOR EQUIPMENT SHALL BE NEMA <br />3R RATED, INCLUDING ALL ROOF MOUNTED <br />TRANSITION BOXES AND SWITCHES: <br />ALL EQUIPMENTS SHALL BE PROPERLY <br />GROUNDED AND BONDED IN-ACCORDANCE <br />WITH NEC ARTICLE 250. <br />ALL CIRCUITS CONNECTED TO MORE THAN <br />ONE SOURCE SHALL HAVE OVERCURRENT <br />DEVICES LOCATED SO AS TO PROVIDE <br />OVERCURRENT PROTECTION FROM ALL <br />SOURCES. <br />THE UTILITY-INTERACTIVE INVERTERS SHALL <br />AUTOMATICALLY DE-ENERGIZE iTS OUTPUT <br />TO THE CONNECTED ELECTRICAL PRODUCTION <br />AND DISTRIBUTION NETWORK UPON LOSS OF <br /> VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN <br />THAT STATE UNTIL THE ELECTRICAL <br />PRODUCTION AND DISTRIBUTION NEIWORK <br />VOLTAGE HAS BEEN RESTORED. <br />DUE TO THE FACT THAT PV MODULES ARE <br />ENERGIZED WHENEVER EXPOSED TO THE LIGHT, <br />PV CONTRACTOR SHALL DiSABLE THE ARRAY <br />DURING INSTALLATION AND SERVICE BY SHORT <br />CIRCUITING, OPEN CIRCUITING, OR COVERING <br />THE ARRAY WITH OPAQUE COVERING. <br />ALL CONDUCTORS EXPOSED TO WEATHER SHALL <br />BE LISTED AND IDENTIFIED FOR USE IN DIRECT <br />SUNLIGHT. <br />THE MODULE CONDUCTORS MUST BE TYPE USE-2 <br />OR LISTED FOR PHOTOVOLTAIC WIRE.PV SYSTEM <br />CONNECTED ON THE LOAD SIDE OF THE SERVICE <br />DISCONNECTING MEANS OF THE OTHER <br />SOURCES AT ANY DISTRIBUTION EQUIPMENT ON <br />THE PREMISES SHALL MEET THE FOLLOWING: <br />- EACH SOURCE CONNECTION SHALL BE <br />MADE AT THE DEDICATED CIRCUIT BREAKER <br />OR FUSiBLE DISCONNECTING MEANS. <br />- THE SUM OF THE AMPERE RATING OF THE <br />OVERCURRENT DEVICES IN CIRCUITS <br />SUPPLYING POWER TO THE BUSBAR OR <br />CONDUCTOR SHALL NOT EXCEED 120% OF <br />THE RATING OF BUSBAR OR CONDUCTOR. <br />THE INTERCONNECTION POINT SHALL BE <br />;ON THE LINE SIDE OF THE GROUND FAULT <br />PROTECTION EQUIPMENT. <br />- EQUIPMENT CONTAINING OVERCURRENT <br />DEVICES IN CIRCUITS SUPPLYING POWER <br />TO THE BUSBAR OR CONDUCTORSHALL BE <br />MARKED TO INDICATE THE PRESENCE OF <br />ALL SOURCES. <br />- CIRCUIT BREAKER, IF BACKFED, SHALL BE <br />SUITABLE FOR SUCH OPERATIONS. <br />TO MINIMIZE OVERHEATING OF THE BUSBAR <br />IN PANEL BOARD, THE PANEL BOARD MAIN <br />CIRCUIT BREAKER AND PV POWER SOURCE <br />CIRCUIT BREAKERSHALL BE PHYSICALLY <br />LOCATED AT THE OPPOSITE END OF THE BUSBAR. <br />ALL NEC REQUIRED WARNING SIGNS, MARKINGS, <br />AND LABELS SHALL BE POSTED ON EQUIPMENT <br />AND DISCONNECTS PRIOR TO ANY INSPECTIONS <br />TO BE PERFORMED BY THE BUILDING <br />DEPARTMENT INSPECTOR. <br />METALLIC RACEWAYS OR METALLIC <br />ENCLOSURES ARE REQUIRED WIRING METHOD <br />FOR INSIDE THE BUILDING FOR PV SYSTEMS. <br />FLEXIBLE, FINE-STRANDED) CABLES;SHALL BE <br />TERMINATED ONLY WITH TERMINALS, LUGS, <br />DEVICES, OR CONNECTOR THAT ARE IDENTIFIED <br />AND LISTED FOR SUCH USE. <br />CONNECTORS SHALL BE LATCHING OR LOCKING <br />TYPE. CONNECTORS THAT ARE READILY <br />ACCESSIBLE.AND OPERATING ATYOVER 30 VOLTS <br />SHALL REQUIRE TOOL TO OPEN AND MARKED '[DO <br />NOT DISCONNECT UNDER LOAD" OR "NOT FOR <br />CURRENT INTERRUPTING'. <br />EQUIPMENT GROUNDING CONDUCTOR FOR PV <br />MODULES SMALLER THAN 6AWG SHALL BE <br />PROTECTED FROM PHYSICAL DAMAGEBY A <br />RACEWAY OR CABLE ARMOR. <br />EQUIPMENT GROUNDING CONDUCTOR FOR PV <br />SYSTEM WITHOUT GROUND FAULT PROTECTION <br />AND INSTALLED ON NON-DWELLING UNIT MUST <br />HAVE AMPACITY OF AT LEAST 2 TIMES THE <br />TEMPERATURE AND CONDUIT FILL CORRECTED <br />CIRCUIT CONDUCTOR AMPACITY <br />FINE-STRANDED CABLES USED FOR BATTERY <br />TERMINALS, DEVICES, AND CONNECTIONS <br />REQUIRE LUGS AND TERMINALS. LISTED AND <br />MARKED FOR THE USE. <br />NO BUILDING, PLUMBING OR MECHANICAL <br />VENTS TO BE COVERED OR OBSTRUCTED <br />BY THESOLAR MODULES. <br />NOTIFY SERVING UTILITY BEFORE ACTIVATION <br />OF;PV SYSTEM. 1 <br />1 1 <br />WHEN A BACKFED BREAKER IS THE METHOD OF .A™*aG By --0-» <br />UTILITY INTERCONNECTION, BREAKER SHALL NOT <br />READ LINE AND LOAD.PROJECT INFORMATION , 7 <br />CONDUITS TO BE PAINTED TO MATCH RESIDENCE <br />SMOKE AND CARBON MONOXIDE DETECTORS 10 SVNPOWER <br />WILL BE INSTALLED IF RESIDENCE DQES NOT E20-327 <br />HAVE ANY SOLAR MODULES <br />( Code references: CBC § 907.2.11.5 and CRC § R314) & <br />( Code references: CBC §420.4 and CRC § R31@ 1 PVI-3.0-OUID-S-US-A <br />INVERTER <br />ROOF MOUNT <br />COMP. SHINGLE <br />106 --*· - 'm-" '9·r: r':rrhA.- 1 - ..I ..y_ DRAWN BY: - CHIC: - APV.:- <br />- I . :··1 11<2669.=TIC=ge. -S-E 'e :4-1 019 <br />LD._70 N - 11 3 3 01 GSS <br />G.p. l..0 ame 21 CLIENT INFORMATION '1 <br />PLANNER 9- 501-0 DATE 3 //1 ) IM ANTONIO <br />ALONZO <br />1-RANSFERRED BY DATE <br />2218 EVERGREEN ST <br />PLANNING INSPECTION REQUIRED:SANTA ANA, CA <br />ROUGH FINAL_NONE >t -92707 <br />NAME (714) - PHOTOVOLTAI <br />- - SOLAR SYSTE <br />RETAIN PLANE FOR FUTURE REVIS]O·NS. --, <br />SUBJECT TO ITEMS CHECKED AND CONDITIONEHEETTITLEBELOW: .':.3 <br />O INTERIOR TI ONLY <br />O NO EXTERK>R ALTERATIONS/MODIFICAT,ONS TITLE SHEET O ALL MATERIALS TO MATCH EXISTING <br />O SCREENING REQUIRED <br />O SUBMIT LANDSCAPE PLANS <br />0 <br />8. ALL ELECTRICAL CONDUIT TO BE METAL ECEI V:E <br />CONDUIT.R D CONDITIONS: fol©·r .RA fe'e'\ i SHEET NUMBER! <br />MAR 1 8 2014 <br />City of Santa Ana Th