Laserfiche WebLink
WIRE/CONDUIT SCHEDULE <br />NUMBER OF CONDUITTAGDESCRIPTIONCONDUCTOR TYPE/SIZE NOTES <br />CONDUCTORS SIZE/TYPE <br />1 ARRAY TO JUNCTION BOX #10 AWG PV WIRE 4 N/A FREE AIR <br />2 JUNCTION BOX TO INVERTER #10 AWG THWN-2 4 1" EMT <br />3 NVERTER TO PV METER #10 AWG THWN-2 3 *' EMT <br />4 'V METER TO AC DISCONNECT #10 AWG THWN-2 3 *' EMT <br />5 AC DISCONNECT TO MSP #10 AWG THWN-2 3 *' EMT <br />6 BARE COPPER WIRE #8 AWG SOLID COPPER 1 N/A <br />7 EQUIPMENT GROUND CONDUCTOR #8 AWG THWN-2 1 *' EMT <br />8 EQUIPMENT GROUND CONDUCTOR #6 AWG THWN-2 1 *' EMT <br />9 DC GROUND ELECTRODE CONDUCTOR #6 AWG THWN 1 ARMORED <br />GENERAL ELECTRICAL NOTES: <br />1. EQUIPMENT USED SHALL BE NEW, UNLESS OTHERWISE NOTED. <br />2. EQUIPMENT SHALL BE INSTALLED PROVIDING ADEQUATE PHYSICAL WORKING SPACE AROUND THE <br />| 5 PANELS 5 PANELS EQUIPMENT AND SHALL COMPLY WITH NEC. <br />OTHERWISE NOTED. <br />3. COPPER CONDUCTORS SHALL BE USED AND SHALL HAVE INSULATION RATING 600V, 90°C, UNLESS <br />4. CONDUCTORS SHALL BE SIZED IN ACCORDANCE TO NEC. CONDUCTORS AMPACITY SHALL BE DE-RATED <br />FOR TEMPERATURE INCREASE, CONDUIT FILL AND VOLTAGE DROP. <br />5. ALL CONDUCTORS, EXCEPT USE-2, SHALL BE INSTALLED IN APPROVED CONDUITS OR RACEWAY. CONDUITS <br />SHALL BE ADEQUATELY SUPPORTED AS PER NEC. <br />6. RACKING AND MODULES ARE GROUNDED VIA A CONTINUOUS #10 AWG COPPER CONDUCTOR, GROUNDING <br />' I CLIPS, GROUNDING LUGS AND/OR BONDING JUMPERS. <br />7. LOAD SIDE INTER-CONNECTION SHALL COMPLY WITH NEC <br />8. SMOKE ALARM AND CARBON MONOXIDE DETECTORS SHALL BE LOCATED AS REQD PER SEC. R314 & R315 <br />OF THE CALIFORNIA RESIDENTIAL CODE (CRC) <br />9. ALL EQUIPMENT SHALL BE LISTED FOR THE APPLICATION, UL 1703 FOR MODULES, UL 1741 FOR INVERTERS <br />10. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM <br />1 11. WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ <br />1+ 1 LINE AND LOAD <br />12. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET <br />LOCATIONS ACCORDING TO NEC 314.15 <br />13. ALL METALLIC RACEWAYS SHALL BE BONDED AND ELECTRICALLY CONTINUOUS ACCORDING TO NEC <br />250.90,250.96 <br />14. GROUNDING BUSHINGS ARE PERMITTED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE DC <br />SIDE OF THE SYSTEM, NEC 250.97 <br />15. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS EXCEPT FOR SPLICES OR JOINTS AT <br />BUSBARS WITHIN LISTED EQUIPMENT, NEC 250.64(C) <br />rl A <br />MODULE SPECIFICATION <br />PHONO SOLAR <br />MODEL NO. <br />PS300P-24/T <br />PEAK POWER 300W <br />RATED VOLTAGE (Vmp)35.6V <br />RATED CURRENT (Imp)8.44A Q <br />OPEN CIRCUIT VOLTAGE (Voc)45.6V 23 <br />SHORT CIRCUIT CURRENT (Isc)8.65A 0 a <br />0- U <br />INVERTER SPECIFICATION D 2620 2INVERTER MAKE POWER ONE 005 a1-(DUINVERTER MODEL PVI-3.0-OUTD-S-US OU)- <br />MAX. DC VOLT RATING 600V &ia <br />1- m r <br />MAX. AC APPARENT POWER 3000W Z Z <1 <br />010 <br />NOMINAL AC VOLTAGE 240V OU)C <br />MAX AC CURRENT 14.5A <br />ARRAY DETAILS <br />NO. OF MODULE PER STRING 5 <br />NO. OF STRINGS 2 <br />ARRAY WATTS AT STC 3.OkW 1 <br />0 <br />MAX. VOLTAGE 246.4V E <br />NOTE: A CENTER-FED BUS WILL * 2 <br />NOT BE USED.Ag <br />NOTE: INTERSYSTEM BONDING <br />KIT WILL BE ACCESSIBLE 00 <br />UTILITY INSTALLED ON THE WALL NEXT <br />Bl-DIRECTIONAL TO MAIN SERVICE PANELELECTRIC METER ) <br />-/ OVERHEAD <br />SERVICE <br />EXISTING <br />MAIN SERVICE PANEL <br />100A, 240VAC, 1PH <br />INTERACTIVE CIRCUIT BREAKER .\.1 <br />WILL BE PLACED AT EXTREME\ <br />END OF BUSS OPPOSITE UTILITY SUPPLY ././ <br />MAIN <br /> OCPD <br />100A <br />COMBINER BOX <br />WITH 15A FUSE <br />2 <br />DC INTERFACE POWER ONE PVI-3.0-OUTD-S-US <br />INTEGRATED DC 3000W, 96% CEC <br />DISCONNECT 240VAC, 14.5A AC INTERFACE <br />PV METER <br />ITRON <br />AC DISCONNECT 240VAC, <br />30A NEMA 3R, UL LISTED <br />KNIFE BLADE TYPE <br />DC+ <br />9 MPPT 1 <br />V <br />OMPPT 2 <br />0 <br />3 <br />-0 <br />20A FUSE <br />C-T-/ <br />0-1- <br />, 20A <br />3Nll <br />0 <br />0 V <br />Ll - <br />DC <br />9 MPPT 1- --418- <br />4 <br />88 MPPT 2 <br />DC DISCONNECT <br />25A. 600V <br />D <br />V <br />GND <br />N L2 · Ll <br />NOTE: WHEN METALLIC CONDUIT IS USED. <br />IT MUST BE BONDED AT BOTH ENDS. <br />r <br />1 <br />- - WATER(#4 AWG) <br />EXISTING <br />UFER GROUND OR <br />GROUND ROD PV 3 <br />(/14) /44-10/3 <br />5Kt=A, LA 9262 1 <br />V <br />T: 714-676-8888