DESCRIPTION OF OPERATION: <br />FS-1: MASTER <br />WH <br />BK <br />A B C D E F G H I <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />MOTOR POWER CIRCUIT <br />PANEL LID <br />COMPONENT LIST <br />LABEL DESCRIPTION <br />ST-X <br />varies <br />Starter <br />OL-X <br />varies <br />Overload <br />C-X <br />varies <br />Contactor <br />120 VAC <br />RELAY <br />RA-x <br />24 VDC <br />RELAY <br />RD-x <br />PS-1 <br />MDP18-24A-1C <br />Power Sup. 24VDC <br />BK <br />RA-x <br />34.110.0184.0 <br />120V Relay DPDT <br />WH <br />RA-x <br />34.110.0184.0 <br />120V Relay DPDT <br />GR <br />UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. <br />N1 <br />H1 <br />DC <br />- <br />GN <br />D <br />DC <br />+ <br />8H1 <br />7PCU <br />6ST <br />5KS <br />4KTS <br />3GAS <br />2AR1 <br />1N1 <br />120VJ9 <br />5OV1 <br />4SF1 <br />3EF1 <br />2B1 <br />1IO1 <br />120VJ7 <br />AR1 <br />H12x <br />N12x <br />B1 <br />EF1 <br />SF1 <br />BK IO1 <br />BK <br />BK <br />BK <br />JUMPERW1 <br />BK 14AWG BK <br />64 <br />RD-1 <br />BL PRDC+RO1 <br />RD-x <br />34.110.0188.0 <br />24VDC Light Relay <br />BK WHSF1RA-2 <br />RD-1 <br />24V <br />1 2 3 4 5 6 7 <br />8 9 10 11 12 13 14 <br />J6 <br />N1N1 <br />RO <br />1 <br />FAN <br />PANEL COOLING <br />DRY CONTACTS (SHOWN DE-ENERGIZED) <br />HOOD LIGHTS <br />J3 <br />ECPM03/DAISY CHAIN <br />AR1 H1JUMPER FIRE SYSTEM <br />BK <br />BK <br />BK <br />GAS <br />KS <br />ST <br />NOTE: Configure ECPM03 for CORE <br />SM-1 SM-2 <br />ECPM03 <br />J10 <br />IL <br />1 <br />A <br />IL <br />1 <br />B <br />JUMPER <br />MAKE UP AIR INTERLOCK. <br />1 <br />2 <br />11 <br />1 JUMPER <br />1 <br />2 <br />11 <br />1 JUMPER <br />NOTE: All items on ECPM03 J5 line to be daisy chained <br />from one component to the next, with EOL120A at end <br />of line. Place PN: EOL120A in empty RJ45 port. <br />J3 <br />ECPM03 or Previous EOL <br />J5 <br />MASTER CORE <br />RA-2-1 <br />SFC1 <br />SFO1 <br />14 AWG <br />YW <br />RA-2-2 <br />SFC2 <br />SFO2 <br />14 AWG <br />YW <br />FACTORY WIRING <br />SCHEMATIC <br />CIRCUIT BOARDS <br />ECPM03 <br />SC-20 x 18 x 8.62 BOX <br />CONTROL INPUT 120V <br />H1=LINE, N1=NEUTRAL, 15A <br />BREAKER. DO NOT CONNECT <br />TO SHUNT TRIP BREAKER. <br />SEE INSTALLATION <br />SCHEMATIC FOR ADDITIONAL <br />REQ. <br />NOTE: IF VFD HAS 1PH 240V INPUT, USE L1 & L2 ONLY. <br />IF VFD HAS 1PH 120V INPUT, USE L1 & N ONLY. <br />LEGEND <br />FIELD WIRING <br />FACTORY WIRING <br />BK- BLACK <br />BL- BLUE <br />BR- BROWN <br />OR- ORANGE <br />WH- WHITE <br />OR/BL- OR/BL STRIPE <br />BL/RD- BL/RD STRIPE <br />RD/GN- RD/GN STRIPE <br />WH/BL- WH/BL STRIPE <br />YW- YELLOW <br />GY- GREY <br />PR- PURPLE <br />RD- RED <br />GR- GREEN <br />WH <br />/ <br />B <br />L <br />BL <br />H1N1 <br />DC <br />- <br />DC <br />+ <br />LN <br />-+ <br />PS-01 <br />AC <br />24V <br />GN <br />D <br />DCKSKSBKKS <br />BK <br />BK <br />GAS <br />ST <br />BKEF1 <br />PR <br />WH <br />GR <br />/ <br />Y <br />W <br />WH <br />/ <br />B <br />L <br />BL <br />J4 J5 <br />J1 <br />ECPM03 <br />SCADA <br />WIRED BK <br />RD <br />+/24V <br />-/GND <br />DEST <br />DEST <br />ILB <br />ILC <br />ILA <br />DEST <br />DEST <br />TO ETH <br />CAT-5 <br />SCADA SCADA Module <br />SHDANT <br />Wired to <br />Master CORE <br />(if applicable) <br />Use shielded wire <br />BK <br />RD <br />SD <br />JUMPER <br />ECPM03 <br />J10 <br />IL <br />2 <br />A <br />IL <br />2 <br />B <br />TERMINAL GAS USED FOR <br />120V POWERED GAS VALVES <br />ONLY <br />8221654 <br />Arte Restaurant ... <br />FACTORY <br />DCV-1111 <br />9/5/2025 <br />ECP #1-6 <br />Demand Control Ventilation, w/ <br />control for 1 Exhaust Fan, 1 Supply <br />Fan, Exhaust on in Fire, Lights out <br />in Fire, Fans modulate based on <br />duct temperature. INVERTER DUTY <br />3 PHASE MOTOR REQUIRED FOR <br />USE WITH VFD. Room <br />temperature sensor shipped loose <br />for field installation.Verify distance <br />between VFD and Motor; additional <br />cost could apply if distance exceeds <br />50 feet. <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />U/T1 <br />V/T2 <br />W/T3 <br />L1 <br />L2 <br />L3/N <br />GR <br />GR <br />GND <br />VFD: <br />HP: <br />MTR: <br />FLA: <br />P107: <br />P108: <br />P410: <br />P150: <br />P100: <br />P194: <br />P101: <br />P131: <br />P167: <br />P103: <br />P102: <br />L1 <br />L2 <br />L3 <br />12 AWG <br />3 PH <br />30 A <br />208 V <br />U1 <br />V1 <br />W1 <br />SM-1 <br />ESV402N02TXB571 225 <br />01 <br />01 <br />11 <br />87 <br />00 <br />14.5 <br />5.000 <br />EF <br />N/A <br />N/A <br />62.8 <br />53.3 <br />0.0 <br />GND <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />BK <br />U/T1 <br />V/T2 <br />W/T3 <br />L1 <br />L2 <br />L3/N <br />GR <br />GR <br />GND <br />VFD: <br />HP: <br />MTR: <br />FLA: <br />P107: <br />P108: <br />P410: <br />P150: <br />P100: <br />P194: <br />P101: <br />P131: <br />P167: <br />P103: <br />P102: <br />L4 <br />L5 <br />L6 <br />14 AWG <br />3 PH <br />15 A <br />208 V <br />U2 <br />V2 <br />W2 <br />SM-2 <br />ESV751N02YXB571 225 <br />01 <br />01 <br />21 <br />90 <br />00 <br />3.8 <br />1.000 <br />MAU <br />N/A <br />N/A <br />64.4 <br />64.4 <br />0.0 <br />GND <br />A B C D E F G H I <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />FACTORY WIRING <br />SCHEMATIC <br />CORE FIRE <br />PROTECTION <br />COMPONENT LIST <br />LABEL DESCRIPTION <br />120 VAC <br />RELAY <br />RA-x <br />24 VDC <br />RELAY <br />RD-x <br />24 VOLT BATTERY PACK <br />5 AMP FUSE <br />RD <br />SHIELDED TWISTED PAIR <br />PCB-2 <br />J3-2 <br />J4-1 <br />J3-11 <br />J4-3 <br />J4-2 <br />J4-8 <br />J4-9 <br />J4-12 <br />J3-14 <br />J4-5 <br />J3-13 <br />J3-4 <br />J4-6 <br />J3-10 <br />J2-1 <br />J2-2 <br />J2-3 <br />J2-4 <br />J7-2 <br />J7-3 <br />J7-1 <br />J3-1 J3-3 <br />RD <br />RD BR <br />RD <br />MAX 16AWG <br />RD BK <br />ORRD <br />PKRD <br />BRRD <br />RD OR/BL <br />BK 18AWG <br />BK <br />BK <br />J3-5 <br />J1-1 <br />J1-2 <br />RD <br />BK <br />BK <br />RD <br />FIRE STAT SUPERVISED LOOP <br />May be mixed factory and field wiring. See <br />Installation Schematic. Multiple fire sensors <br />possible. <br />+ <br />+ <br />RD <br />BK <br />BK <br />RD <br />Shield <br />BK <br />RD <br />RS-485 CORE INTERLOCK <br />NETWORK. Connection to other <br />CORE Panels or Communication <br />Module. See Installation Schematic <br />for Connection. <br />N1D 3xH1D3x <br />DISCONNECT J1 <br />21 <br />22 <br />23 <br />24 <br />16AWG <br />WHN1 <br />H1 <br />PN: 1606-XLP-60EQ <br />Adjust power supply to 27.5 Volts with an <br />accurate Digital Volt Meter or with an HMI <br />plugged into the CORE board. <br />NL <br />+- <br />PS-02 60W <br />GR <br />BK <br />GND <br />PCB-2 <br />PCBCORE-APP <br />CORE PCB <br />PS-02 <br />1606-XLP-60E <br />CORE POWER SUPPLY <br />WS-x <br />varies <br />Water Solenoid <br />LT-06 <br />WL-1090D1-28V <br />24V Red Ind. Light <br />LL-01 <br />AQ5510 <br />Surf. Level Sensor <br />AA-01 <br />SCE120LA3FP1B <br />Audible Alarm <br />PB-XX <br />ZB4BA2/ZB4BZ1015 <br />Prime/Reset Switch <br />SW-04 <br />BZ-2RQ1-A2 <br />Tamper Switch <br />SP-1 <br />50000-805 <br />Surfactant Pump <br />PB-01 <br />Prime / Reset <br />RD-20 <br />Trouble Relay <br />RD-17 <br />Fire Relay <br />DRY CONTACTS (SHOWN DE-ENGERGIZED) <br />AA-01 <br />Audible Alarm <br />SW-04 <br />Door Tamper Switch <br />C NO <br />FS-01 <br />BK WH <br />Fire Stat <br />FS-02 <br />BK WH <br />Fire Stat <br />HIGH TEMP WIRE (842 F), PN: <br />SLPCON-xFT required for all <br />Supervised Loop wiring in contact with <br />a hood. All other wiring shall be PN: <br />6320UL, Belden or similar. Factory <br />mounted hood sensors will be <br />terminated at junction box on top of <br />hood. <br />GV-1 <br />varies <br />24v DC Gas Valve <br />INTERLOCK FOR AUTOMAN ACTIVATION. Used <br />for activating 120V automan or adjacent Master <br />CORE panels during active Fire Condition. <br />RD-18-1 <br />YW <br />J3-16 <br />J3-8 <br />LT-6 <br />R <br />FIRE INDICATOR <br />DIP Switch <br />ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD <br />BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES. <br />RD/GNRDRD-19 <br />Equipment Relay COOKING EQUIPMENT DISABLE RELAY. For UDS <br />Kill Switch, wire EKC and EKS terminals to like <br />terminals in UDS panel. <br />RD-19-1 <br />EKC <br />EST <br />EKS <br />YW <br />INTERLOCK FOR AUTOMAN ACTIVATION. Used <br />for activating 120V automan or adjacent Master <br />CORE panels during active Fire Condition. <br />RD-18-1 <br />YW <br />RD OR/BLRD-18 <br />Auxiliary Interlock Relay <br />FS-XX <br />12-F28021-000360 <br />Duct Fire Sensor <br />LT-05 <br />WL-1090D3-28V <br />24V YLW Ind. Light <br />PS-01 <br />Station STI-SS2431 <br />Remote Puill/Push <br />FOR SHIPMENT <br />J10-1 <br />J10-2 <br />J10-3 <br />J10-4 <br />RD <br />BK <br />BK <br />RD <br />101 <br />102 <br />103 <br />104 <br />MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM <br />LOOP. <br />Multiple manual actuation possible. <br />A Plug jumper with wires from pin1 to pin4 and from pin2 to <br />pin3 should be mounted on J10 if there is no manual <br />actuation device and no microswitch. <br />MAD-01 <br />C NO <br />Manual <br />Actuation <br />Device <br />MS-01 <br />C NO <br />Micro SW <br />1 2 3 4 5 6 7 8 <br />SW <br />1 <br />ON <br />PUT END OF LINE PLUG IN EMPTY RJ45 <br />J3 <br />ECPM03 <br />UNLESS PCU AFM OR OTHER COMPONENT IN SERIES. <br />CAT-5 WIRING (MASTER ONLY) <br />FIELD WIRED IF REMOTE PREWIRE <br />RD-XX <br />PLC-RPT-24DC/21 <br />24VDC Phoenix Relay <br />AUX-01 <br />AU1 AU2 <br />Auxiliary Interlock (AUX-01): <br />Wire AU1 / AU2 of adjacent Master CORE panel(s) in each <br />manual activation loop for simultaneous activation. <br />AU1/AU2 will have continuity for 10 seconds if adjacent panel <br />goes into fire condition, activating this CORE Panel but <br />allowing for a reset after 10 seconds. <br />NOTE: AU1/AU2 terminals of CORE Panel should not be <br />wired into its own manual activation loop.Adjacent <br />CORE Panel <br />Master CORE set DIP <br />SW 8 to CLOSED <br />position. Slave CORE <br />with address 1 set <br />DIP SW 8 to <br />CLOSED position. All <br />other CORES set DIP <br />SW 8 OPEN. <br />18AWG <br />LEGEND <br />FIELD WIRING <br />FACTORY WIRING <br />BK- BLACK <br />BL- BLUE <br />BR- BROWN <br />OR- ORANGE <br />WH- WHITE <br />OR/BL- OR/BL STRIPE <br />BL/RD- BL/RD STRIPE <br />RD/GN- RD/GN STRIPE <br />WH/BL- WH/BL STRIPE <br />YW- YELLOW <br />GY- GREY <br />PR- PURPLE <br />RD- RED <br />GR- GREEN <br />FIRE INDICATOR FAULT CONDITION FLASH CODES <br />2 Release Solenoid <br />3 Pressure Switch <br />4 Auxiliary Fault <br />5 Microcontroller Fault <br />6 N/A <br />7 Supervised Loop <br />8 Ground Fault <br />9 Surfactant Low <br />10 Battery Voltage Low <br />11 AC Power Failure <br />12 Door Tamper Switch <br />13 Test Mode <br />14 CORE Interlock Network <br />15 Fault on Hood in Interlock Network <br />16 Fault on PCU in Interlock Network <br />FIRE ALARM SYSTEM DRY CONTACTS. Termials <br />AL1 & AL2 make in FIRE. <br />To Building Fire Alarm <br />Panel <br />J9 <br />AL1 <br />AL2 <br />J3-7 <br />FIRE SYSTEM DRY CONTACTS. <br />Dry contacts will make C2 to AR2 when system is <br />armed. <br />RD-17-1 <br />C2 <br />AR2 <br />14 AWG <br />YW <br />TROUBLE RELAY. Contact terminals TBC & TBL <br />make if there is trouble. Contact terminals TBC & <br />TOK make if the system is ok. <br />RD-20-1 <br />TBC <br />TBL <br />TOK <br />YW <br />RD PS OR J4-9 <br />PS <br />EWC-PRESSURE <br />Pressure Switch <br />PR RS <br />SW-05-1 <br />Test Armed <br />3 4 YW RS-1 <br />RELEASE SOLENOID <br />BLBR <br />RD ORSW-05-3 <br />Test Armed <br />3 4 J4-13 <br />SW-05 <br />ZB5AD2 <br />TEST/ARM Switch <br />RS2PRSW-05-2 <br />Test Armed <br />3 4 YW <br />PS-1 <br />Pressure Switch <br />WH <br />PWS-01 <br />24VDC 18W POWER <br />24VDC Power Suppl <br />CA <br />CB <br />CC <br />AU1AU1 <br />AU2AU2 <br />TR2 <br />MAD-01 <br />DEVICE <br />MANUAL ACTIVATION <br />GAS VALVES SHOULD BE WIRED TO <br />MASTER CORE BOARD ONLY. <br />RDRD <br />GV-1 <br />24V DC Gas ValveLGVPK TERMINAL LGV USED FOR 24VDC <br />POWERED GAS VALVES ONLY. <br />(2nd Contact) <br />BK WHH1 N1 <br />FAN <br />PANEL COOLING <br />*POWER FROM H1/N1 ONLY ON STANDALONE PACKAGE W/O ECP <br />8221654 <br />Arte Restaurant ... <br />FACTORY <br />DCV-1111 <br />9/5/2025 <br />ECP #1-7 <br />Fire System #1 TANK FS - 4.0/4.0. <br />Tank-based Fire Protection System <br />equipped with Electronic Detection <br />utilizing CORE board as a Listed <br />Release Mechanism. Installed in <br />Wall Mounted Utility Cabinet <br />separate from prewire. Includes 12" <br />box housing circuit board, batteries, <br />and terminals for connection to main <br />control panel. <br />FS-1: MASTER <br />CONTROL PANEL. <br />LCD <br />INTERFACE. <br />DUCT TEMPERATURE SENSOR. <br />ROOM TEMPERATURE <br />SENSOR. <br />DEMAND CONTROL VENTILATION HOOD CONTROL PANEL SPECIFICATIONS: <br />-CONTROLS SHALL BE LISTED BY ETL (UL 508A) AND SHALL COMPLY WITH DEMAND VENTILATION SYSTEM <br />TURNDOWN REQUIREMENTS OUTLINED IN IECC 403.7.5 (2021). <br />-THE CONTROL ENCLOSURE SHALL BE NEMA 1 RATED AND LISTED FOR INSTALLATION INSIDE OF THE <br />EXHAUST HOOD UTILITY CABINET. THE CONTROL ENCLOSURE MAY BE CONSTRUCTED OF STAINLESS STEEL <br />OR PAINTED STEEL. <br />-TEMPERATURE PROBE(S) LOCATED IN THE EXHAUST DUCT RISER(S) SHALL BE CONSTRUCTED OF <br />STAINLESS STEEL. <br />-A DIGITAL CONTROLLER SHALL BE PROVIDED TO ACTIVATE THE HOOD EXHAUST FANS DYNAMICALLY BASED <br />ON A FIXED DIFFERENTIAL BETWEEN THE AMBIENT AND DUCT TEMPERATURES SENSORS. THIS FUNCTION <br />SHALL MEET THE REQUIREMENTS OF IMC 507.1.1. <br />-A DIGITAL CONTROLLER SHALL PROVIDE ADJUSTABLE HYSTERESIS SETTINGS TO PREVENT CYCLING OF THE <br />FANS AFTER THE COOKING APPLIANCES HAVE BEEN TURNED OFF AND/OR THE HEAT IN THE EXHAUST <br />SYSTEM IS REDUCED. <br />-A DIGITAL CONTROLLER SHALL PROVIDE AN ADJUSTABLE MINIMUM FAN RUN-TIME SETTING TO PREVENT FAN <br />CYCLING. <br />-VARIABLE FREQUENCY DRIVES (VFDS) SHALL BE PROVIDED FOR FANS AS REQUIRED. THE DIGITAL <br />CONTROLLER SHALL MODULATE THE VFDS BETWEEN A MINIMUM SETPOINT AND A MAXIMUM SETPOINT ON <br />DEMAND. THE DUCT TEMPERATURE SENSOR INPUT(S) TO THE DIGITAL CONTROLLER SHALL BE USED TO <br />CALCULATE THE SPEED REFERENCE SIGNAL. <br />-THE VFD SPEED RANGE OF OPERATION SHALL BE FROM 0% TO 100% FOR THE SYSTEM, WITH THE ACTUAL <br />MINIMUM SPEED SET AS REQUIRED TO MEET MINIMUM VENTILATION REQUIREMENTS. <br />-AN INTERNAL ALGORITHM TO THE DIGITAL CONTROLLER SHALL MODULATE SUPPLY FAN VFD SPEED <br />PROPORTIONAL TO ALL EXHAUST FANS THAT ARE LOCATED IN THE SAME FAN GROUP AS THE SUPPLY FAN. <br />-THE SYSTEM SHALL OPERATE IN PREP MODE DURING LIGHT COOKING LOAD OR COOL DOWN MODE WHEN <br />SUFFICIENT HEAT REMAINS UNDERNEATH THE HOOD SYSTEM AFTER COOKING OPERATIONS HAVE <br />COMPLETED. OPERATION DURING EITHER OF THESE PERIODS WILL DISABLE THE SUPPLY FANS AND PROVIDE <br />AN EXHAUST FAN SPEED THAT IS EQUAL TO THE MINIMUM VENTILATION REQUIREMENT. <br />-A DIGITAL CONTROLLER SHALL DISABLE THE SUPPLY FAN(S), ACTIVATE THE EXHAUST FAN(S), ACTIVATE <br />THE APPLIANCE SHUNT TRIP, AND DISABLE AN ELECTRIC GAS VALVE AUTOMATICALLY WHEN FIRE CONDITION <br />IS DETECTED ON A COVERED HOOD. <br />-A DIGITAL CONTROLLER SHALL ALLOW FOR EXTERNAL BMS FAN CONTROL VIA DRY CONTACT (EXTERNAL <br />CONTROL SHALL NOT OVERRIDE FAN OPERATION LOGIC AS REQUIRED BY CODE). <br />-AN LCD INTERFACE SHALL BE PROVIDED WITH THE FOLLOWING FEATURES: <br />A. ON/OFF PUSH BUTTON FAN & LIGHT SWITCH ACTIVATION. <br />B. INTEGRATED GAS VALVE RESET FOR ELECTRONIC GAS VALVES (NO RESET RELAY REQUIRED). <br />C. VFD FAULT DISPLAY WITH AUDIBLE & VISUAL ALARM NOTIFICATION. <br />D. DUCT TEMPERATURE SENSOR FAILURE DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION. <br />E. MIS-WIRED DUCT TEMPERATURE SENSOR DETECTION WITH AUDIBLE & VISUAL ALARM NOTIFICATION. <br />F. A SINGLE LOW VOLTAGE CAT-5 RJ45 WIRING CONNECTION. <br />G. AN ENERGY SAVINGS INDICATOR THAT UTILIZES MEASURED KWH FROM THE VFDS. <br />SEQUENCE OF OPERATIONS: <br />THE HOOD CONTROL PANEL IS CAPABLE OF OPERATING IN ONE OR MORE OF THE FOLLOWING STATES AT ANY <br />GIVEN TIME: <br />-AUTOMATIC: THE SYSTEM OPERATES BASED ON THE DIFFERENTIAL BETWEEN ROOM TEMPERATURE AND <br />THE TEMPERATURE AT THE HOOD CAVITY OR EXHAUST DUCT COLLAR. FANS ACTIVATE AT A <br />CONFIGURABLE TEMPERATURE DIFFERENTIAL THRESHOLD. DEPENDING ON THE JOB CONFIGURATION EACH FAN <br />ZONE CAN BE CONFIGURED AS STATIC OR DYNAMIC. THESE TERMS REFER TO WHETHER A VARIABLE <br />MOTOR (SUCH AS EC MOTORS OR VFD DRIVEN MOTORS) MODULATE WITH TEMPERATURE. IF THE PANEL IS <br />EQUIPPED WITH VARIABLE SPEED FANS AND THE ZONE IS DEFINED AS "DYNAMIC", THESE WILL MODULATE <br />WITHIN A USER-DEFINED RANGE BASED ON THE TEMPERATURE DIFFERENTIAL. PANELS EQUIPPED WITH <br />VARIABLE SPEED FANS AND A FAN ZONE DEFINED AS "STATIC", FANS WILL RUN AT A SET SPEED <br />CALCULATED FOR THE DRIVE. DEMAND CONTROL VENTILATION SYSTEMS ARE CAPABLE OF MODULATING <br />EXHAUST AND MAKE UP AIR FAN SPEEDS PER THE REQUIREMENTS OUTLINED IN IECC 403.7.5 (2021). <br />-MANUAL: THE SYSTEM OPERATES BASED ON HUMAN INPUT FROM AN HMI. <br />-SCHEDULE: A WEEKLY SCHEDULE CAN BE SET TO RUN FANS FOR A SPECIFIED PERIOD THROUGHOUT THE <br />DAY. THERE ARE THREE OCCUPIED TIMES PER DAY TO ALLOW FOR THE USER TO SET UP A TIME THAT IS <br />SUITABLE TO THEIR NEEDS. ANY TIME THAT IS WITHIN THE DEFINED OCCUPIED TIME, THE SYSTEM WILL RUN <br />AT MODULATION MODE AND FOLLOW THE FAN PROCEDURE ALGORITHM BASED ON TEMPERATURE DURING THIS <br />TIME. DURING UNOCCUPIED TIME, THE SYSTEM WILL HAVE AN EXTRA OFFSET TO PREVENT UNINTENDED <br />ACTIVATION OF THE SYSTEM DURING A TIME WHERE THE SYSTEM IS NOT BEING OCCUPIED. <br />-OTHER: THE SYSTEM OPERATES BASED ON THE INPUT FROM AN EXTERNAL SOURCE (DDC, BMS OR <br />HARD-WIRED INTERLOCK). <br />FIRE:UPON ACTIVATION OF THE HOOD FIRE SUPPRESSION SYSTEM, THE EXHAUST FAN WILL COME ON OR <br />CONTINUE TO TO RUN, THE HOOD MAKEUP AIR WILL SHUTDOWN, AND A SIGNAL WILL BE SENT FOR <br />ACTIVATING THE SHUNT TRIP BREAKER PROVIDED BY THE ELECTRICIAN. FUEL GAS WILL SHUT OFF VIA A <br />MECHANICAL/ELECTRICAL GAS VALVE ACTUATED BY THE HOOD FIRE SUPPRESSION SYSTEM. <br />- <br />SYSTEM DESIGN VERIFICATION (SDV) <br />IF ORDERED, CAS SERVICE WILL PERFORM A SYSTEM DESIGN VERIFICATION (SDV) ONCE ALL EQUIPMENT HAS HAD A <br />COMPLETE START UP PER THE OPERATION AND INSTALLATION MANUAL. TYPICALLY, THE SDV WILL BE PERFORMED AFTER <br />ALL INSPECTIONS ARE COMPLETE. <br />ANY FIELD RELATED DISCREPANCIES THAT ARE DISCOVERED DURING THE SDV WILL BE BROUGHT TO THE <br />ATTENTION OF THE GENERAL CONTRACTOR AND CORRESPONDING TRADES ON SITE. THESE ISSUES <br />WILL BE DOCUMENTED AND FORWARDED TO THE APPROPRIATE SALES OFFICE. IF CAS SERVICE HAS TO <br />RESOLVE A DISCREPANCY THAT IS A FIELD ISSUE, THE GENERAL CONTRACTOR WILL BE NOTIFIED AND <br />BILLED FOR THE WORK. SHOULD A RETURN TRIP BE REQUIRED DUE TO ANY FIELD RELATED DISCREPANCY THAT CANNOT <br />BE RESOLVED DURING THE SDV, THERE WILL BE ADDITIONAL TRIP CHARGES. <br />DURING THE SDV, CAS SERVICE WILL ADDRESS ANY DISCREPANCY THAT IS THE FAULT OF THE MANUFACTURER. SHOULD A <br />RETURN TRIP BE REQUIRED, THE GENERAL CONTRACTOR AND APPROPRIATE SALES OFFICE WILL BE NOTIFIED. THERE <br />WILL BE NO ADDITIONAL CHARGES FOR MANUFACTURER DISCREPANCIES. <br />SHEET NO. <br />SCALE: <br />DWG.#: <br />DRAWN <br />DATE: <br /> BY: <br />REVISIONS <br />ww <br />w <br />. <br />c <br />a <br />p <br />t <br />i <br />v <br />e <br />a <br />i <br />r <br />e <br />. <br />c <br />o <br />m <br /> <br /> <br /> <br />AC <br />C <br />O <br />R <br />D <br />A <br />N <br />C <br />E <br />No <br />. <br /> <br />9 <br />6 <br />BU <br />I <br />L <br />T <br />NF <br />P <br />A <br />WI <br />T <br />H <br />IN <br />S <br />LI <br />D <br />TE <br />R <br />8221654 <br />MASTER DRAWING <br />AR <br />Ar <br />t <br />e <br /> <br />R <br />e <br />s <br />t <br />a <br />u <br />r <br />a <br />n <br />t <br /> <br />- <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />R <br />e <br />v <br />1 <br />10 <br />9 <br /> <br />E <br />a <br />s <br />t <br /> <br />4 <br />t <br />h <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br />, <br />So <br />u <br />t <br />h <br />e <br />r <br />n <br /> <br />C <br />a <br />l <br />i <br />f <br />o <br />r <br />n <br />i <br />a <br /> <br />O <br />f <br />f <br />i <br />c <br />e <br />30 <br />0 <br />2 <br /> <br />D <br />o <br />w <br /> <br />A <br />v <br />e <br />. <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />2 <br />0 <br />2 <br />, <br /> <br />T <br />u <br />s <br />t <br />i <br />n <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />8 <br />0 <br /> <br />P <br />H <br />O <br />N <br />E <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />9 <br />5 <br />7 <br /> <br />- <br /> <br />1 <br />5 <br />0 <br />0 <br /> <br />F <br />A <br />X <br />: <br /> <br />9 <br />1 <br />9 <br />2 <br />2 <br />7 <br />5 <br />9 <br />7 <br />5 <br /> <br />E <br />M <br />A <br />I <br />L <br />: <br /> <br />r <br />e <br />g <br />8 <br />6 <br />@ <br />c <br />a <br />p <br />t <br />i <br />v <br />e <br />a <br />i <br />r <br />e <br />. <br />c <br />o <br />m <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />SHEET TITLE: <br />DATE: SCALE: <br />AR <br />T <br />E <br /> <br />R <br />E <br />S <br />T <br />A <br />U <br />R <br />A <br />N <br />T <br /> <br />03/03/2025 <br />PLOT DATE: 10/24/2025 4:42:11 PM <br />CD <br />I <br /> <br />Ci <br />r <br />c <br />a <br /> <br />D <br />o <br />m <br />i <br />n <br />i <br /> <br />I <br />n <br />t <br />e <br />r <br />n <br />a <br />t <br />i <br />o <br />n <br />a <br />l <br />, <br /> <br />I <br />n <br />c <br />. <br />En <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br /> <br />- <br /> <br />C <br />o <br />n <br />s <br />u <br />l <br />t <br />i <br />n <br />g <br />98 <br />9 <br />0 <br /> <br />R <br />e <br />s <br />e <br />a <br />r <br />c <br />h <br /> <br />D <br />r <br />. <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />1 <br />0 <br />0 <br />, <br /> <br />I <br />r <br />v <br />i <br />n <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />1 <br />8 <br />Ph <br />o <br />n <br />e <br /> <br />( <br />9 <br />4 <br />9 <br />) <br /> <br />3 <br />3 <br />6 <br />- <br />6 <br />6 <br />3 <br />6 <br /> <br />| <br /> <br />d <br />k <br />a <br />n <br />g <br />@ <br />c <br />d <br />i <br />e <br />n <br />g <br />. <br />c <br />o <br />m <br />10 <br />9 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />DRAWN: CHECKED: <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />R <br />E <br />V <br />. <br /> <br />0 <br />5 <br />/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br />FI <br />E <br />L <br />D <br /> <br />C <br />H <br />A <br />N <br />G <br />E <br /> <br />0 <br />9 <br />/ <br />0 <br />5 <br />/ <br />2 <br />0 <br />2 <br />5 <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />R <br />E <br />V <br />. <br /> <br />0 <br />9 <br />/ <br />2 <br />9 <br />/ <br />2 <br />0 <br />2 <br />5 <br />M206 <br />HOOD <br />INFORMATION <br />D.L.R.C.