Laserfiche WebLink
UP <br />18x36 <br />5 TIER <br />18x60 <br />5 TIER <br />18 <br />x <br />2 <br />4 <br />5 <br />T <br />I <br />E <br />R <br />A.03 <br />18x54 <br />5 TIER <br />18 <br />x <br />3 <br />6 <br />5 <br />T <br />I <br />E <br />R <br />18 <br />x <br />3 <br />6 <br />5 <br />T <br />I <br />E <br />R <br />2 <br />A-2.0 <br />MAX. 5% RUNNING SLOPE <br />& 2% CROSS SLOPE <br />MAX. 5% RUNNING SLOPE <br />& 2% CROSS SLOPE <br />MAX. 5% RUNNING SLOPE <br />& 2% CROSS SLOPE <br />108 <br />OUTDOOR DINING PATIO <br />106 <br />ALL GENDER RR <br />105 <br />ALL GENDER RR <br />104 <br />STORAGE <br />101 <br />DINNING AREA <br />107 <br />KITCHEN AREA <br />103 <br />HALLWAY <br />102 <br />SERVICE AREA <br />3' <br />- <br />1 <br />0 <br />" <br />3'-4"6'-7" <br />14 <br />' <br />- <br />9 <br />" <br />7'-9" <br />15 <br />' <br />- <br />5 <br />" <br />10'-2"10'-8"18'-2"12'-6" <br />18 <br />' <br />- <br />5 <br />" <br />16'-11" <br />7' <br />- <br />2 <br />" <br />4' <br />- <br />1 <br />" <br />14 <br />' <br />- <br />5 <br />" <br />9' <br />- <br />1 <br />0 <br />" <br />3' <br />- <br />0 <br />" <br />3'-0"3'-5" <br />RESTROOM <br />ACCESS SIGN SEE <br />DETAIL 8/ A-0.2, TYP. <br />3'-0" <br />8'-1" <br />106 <br />ALL GENDER RR <br />105 <br />ALL GENDER RR <br />1'-6"1'-6"3'-0" <br />8'-0" <br />3' <br />- <br />6 <br />" <br />10 <br />' <br />- <br />7 <br />" <br />3'-1" <br />3' <br />- <br />6 <br />" <br />8' <br />- <br />6 <br />" <br />4' <br />- <br />0 <br />" <br />13'-4" <br />10 <br />9 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />C <br />A <br /> <br />9 <br />2 <br />70 <br />1 <br />AR <br />T <br />E <br /> <br />R <br />E <br />S <br />T <br />A <br />U <br />R <br />A <br />N <br />T <br />SHEET NO.: <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />SHEET TITLE: <br />DATE: SCALE: <br />02/21/2025 <br />5- <br />2 <br />8 <br />- <br />2 <br />5 <br />1S <br />T <br /> <br />H <br />E <br />A <br />L <br />T <br />H <br /> <br />P <br />C <br />CD <br />I <br />Ci <br />r <br />c <br />a <br /> <br />D <br />o <br />m <br />i <br />n <br />i <br /> <br />I <br />n <br />t <br />e <br />r <br />n <br />a <br />t <br />i <br />o <br />n <br />a <br />l <br />, <br /> <br />L <br />L <br />C <br />En <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br /> <br />- <br /> <br />C <br />o <br />n <br />s <br />u <br />l <br />t <br />i <br />n <br />g <br />98 <br />9 <br />0 <br /> <br />R <br />e <br />s <br />e <br />a <br />r <br />c <br />h <br /> <br />D <br />r <br />. <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />1 <br />0 <br />0 <br />, <br /> <br />I <br />r <br />v <br />i <br />n <br />e <br />, <br /> <br />C <br />A <br /> <br /> <br />9 <br />2 <br />6 <br />1 <br />8 <br />Ph <br />o <br />n <br />e <br />. <br /> <br />( <br />9 <br />4 <br />9 <br />) <br /> <br />5 <br />3 <br />3 <br />- <br />4 <br />1 <br />1 <br />7 <br /> <br />9- <br />4 <br />- <br />2 <br />5 <br />2N <br />D <br /> <br />H <br />E <br />A <br />L <br />T <br />H <br /> <br />P <br />C <br />10 <br />- <br />7 <br />- <br />2 <br />5 <br />1S <br />T <br /> <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />P <br />C <br />10 <br />- <br />7 <br />- <br />2 <br />5 <br />3R <br />D <br /> <br />H <br />E <br />A <br />L <br />T <br />H <br /> <br />P <br />C <br />2N <br />D <br /> <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />P <br />C <br />EGRESS & <br />ENLARGED <br />RESTROOM PLAN <br />1EGRESS PLAN <br />1/4"=1'-0" <br />N <br />FIRE NOTES <br />1 <br />THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES ELECTRICAL <br />SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A <br />DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE <br />GENERATOR PER BUILDING CODE 1006.3 <br />2 WALL, FLOOR AND CEILING FINISHES SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS IN CBC TABLE 803.11 <br />3 ALL DECORATIVE MATERIALS AND TRIM SHALL COMPLY WITH THE PROVISIONS OF CBC 806 <br />4 THERMAL AND ACOUSTICAL INSULATION SHALL COMPLY WITH CBC 720 <br />ACCESSIBLE SEATING CALCULATION <br />REGULAR ADA TOTAL % <br />TABLE SEATING 19 1 20 5% <br />BAR SEATING 12 1 13 7.7% <br />OUTDOOR SEATING 11 1 12 8.3% <br />TOTAL SEATING 53 <br />2ENLARGED RESTROOM FLOOR PLAN <br />1/2"=1'-0" <br />SIGNAGE NOTES <br />1 DIRECTIONAL SIGN VISUAL CHARACTER SHALL BE 40 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND. (11B-216.3, <br />11B-216.6, 11B-703.5.6) <br />2 <br />WHERE BOTH VISUAL AND TACTILE CHARACTERS ARE REQUIRED, EITHER ON SIGN WITH BOTH VISUAL AND TACTILE <br />CHARACTERS, OR TWO SEPARATE SIGNS, ONE WITH VISUAL, AND ONE WITH TACTILE CHARACTERS, SHALL BE PROVIDED. <br />(11B-703.1) <br />3 <br />WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONG THE DOOR AT THE LATCH SIDE. WHERE <br />A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. <br />WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE <br />INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE <br />LOCATED TO THE RIGHT OF THE RIGHT AND DOORS. SIGNS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE 18x18 INCHES <br />MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING. (11B-703.4.2) <br />(FIGURE 11B-703.4.1) <br />4 <br />TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48" MINIMUM ABOVE FINISH FLOOR, MEASURED FROM THE BASELINE OF <br />THE LOWEST BRAILLE CELLS AND 60" MAXIMUM ABOVE FINISH FLOOR, MEASURED FROM THE BASE LINE OF THE HIGHEST LINE <br />OF THE RAISED CHARACTERS. (11B-703.4.1) (FIGURE 11B-703.4.1) <br />5 CORRESPONDING BRAILLE SHALL BE LOCATED BELOW CHARACTERS, 3/8" - 1/2", CENTERED OR FLUSH LEFT. (11B-216, 11B-216.2) <br />6 <br />WHEN SIGNS IDENTIFY PERMANENT ROOMS AND SPACES OF A BUILDING OR SITE, THEY SHALL COMPLY WITH CBC 11B-703.1; <br />11B-703.2; 11B-703.3 AND 11B-703.5. WHERE PICTOGRAMS ARE PROVIDED, IT SHALL COMPLY WITH SECTION 11B-703.6 AND SHALL <br />HAVE TEXT DESCRIPTIONS COMPLYING WITH SECTIONS 11B-703.2 & 11B-703.5. (11B-216.2) <br />N A-2.0 <br />5 <br />5