My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10180994_W ST ANNE - Plan (2)
PBA
>
Building
>
Plans
>
S
>
St Anne Pl
>
2309 W St Anne Pl
>
10180994_W ST ANNE - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2021 11:54:11 PM
Creation date
10/25/2020 9:50:03 PM
Metadata
Fields
Template:
Plan
Permit Number
10180994
Full Address
2309 W St Anne Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
LEVI BUILDERS <br />THE REYES RESIDENCE <br />43.27 kW PHOTOVOLTAIC SYSTEM 0 <br />ISSUE DATE <br />SHEET INDEX <br />CONSTRUCTION SHALL COMPLY WITH 2013 CBCMC CPC, CEC & CRC <br />ELECTRICAL TO COMPLY WITH 2014 NEC AND INTERNAAIONL ELECTRICAL CODEROOFING INFORMATION PHOTOVOLTAIC NOTES 3R <br />'LANS \ <br />90/3/17/2014 <br />REV.:DATE:-DESCRIPTION:-BY <br />Tl - TITLE SHEET <br />ARCHITECTURAL <br />Al - SITE PLAN <br />ELECTRICAL <br />El - ELECTRICAL SITE PLAN <br />E2 - SINGLE LINE <br />E3 - PHOTOVOLTAIC SIGNAGE <br />STRUCTURAL <br />Sl - TYP. CONNECTION DETAILS <br />OTHER PROJECT DETAILS <br />OPD1 -MODULE & INVERTER SPECIFICATIONS <br />EXISTING ROOF C <br />PITCH 1 <br />WIND SPEED 8 <br />EXPOSURECATEGORY C <br />ARRAY INFORMATION <br />MODULE WEIGHT 4 <br />MODULE LENGTH 6 <br />MODULE WIDTH 4 <br />MODULE DEPTH 1 <br />TOTALMODULES 1 <br />TOTAL ROOF AREA 1 <br />TOTAL ARRAY AREA 1 <br />°/0 AREA OF PANELS 1 <br />:OMP. SHINGLE ALL MATERIALS, EQUIPMENT, INSTALLATION AND <br />8 DEGREES WORK SHALL COMPLY W/: <br />5 <br />: - 2013 CBC / 2012 IBC <br />- 2013 CRC / 2013 IRC <br />- 2013 CEC / 2014 NEC <br />- 2013 CMC / 2013 UMC <br />2013 CPC /2013 UPC - + <br />- 2013 CFC / 2013 IFC <br />ALL EQUIPMENT SHALL BE LISTED AND <br />LABELED BY A RECOGNIZED ELECTRICAL <br />TESTING LABORATORY AND INSTALLED PER ' <br />LISTING REQUIREMENTS AND THE <br />MANUFACTURER'S INSTRUCTIONS. <br />1 LBS <br />ALL OUTDOOR EQUIPMENT SHALL BE NEMA <br />1.39" <br />3R RATED, INCLUDING ALL ROOF MOWNTED <br />1.18"TRANSITION BOXES AND SWITCHES. <br />81" A <br />0 ALL EQUIPMENTS SHALL BE PROPERLY <br />GROUNDED AND BONDED IN ACCORDANCE <br />WITH NEC ARTICLE 250. <br />241 SQ. FT./-Z=- <br />81.65 SQ. FT.ALL CIRCUITS CONNECTED TO MORE-J·+·1*R <br />4% <br />Tanges SUP'LYING POWER TO THE BUSBAR OR0BducTOR SHALL NOT EXCEED 120% OFJn tfom THE lrING OF BUSBAR OR CONDUCTOR. <br />- THE INTERCONNECTION POINT SHALL BE <br />s:ik\-0*;CTION EQUIPMENT. <br />ELINE SIDE OF THEGROUND FAULT <br />- EQUIPMENT CONTAINING OVERCURRENT <br />4 DEVICES IN CIRCUITS SUPPLYING POWER <br />TO THE BUSBAR OR CONDUCTOR SHALL BE <br />MARKED TO INDICATE THE PRESENCE OF <br />ALLUPWRCkS. <br />DaterIT BRKER, IF BACKFED, SHALL BE <br />SUITABLE FOI SUCH OPERATIONS. <br />TO MINIMIZE OVERHEATING OF THE BUSBAR <br />IN PANELppARD1THE PANEL BOARD MAIN <br />/-0€€2&22*Rek AND PV POWER SOURCE <br />_1+ERCUIT BREAKER SHALL BE PHYSICALLY <br />-0- LOCATED AT THE OPPOSITE END OF THE BUSBAR <br />NO BUILDING, PLUMBING OR MECHANICAL <br />VENTS TO BE COVERED OR OBSTRUCTED <br />BY THE SOLAR MODULES. <br />NOTIFY SERVING UTILITY BEFORE ACTIVATION <br />OF PV SYSTEM. <br />V.7.ENA BACKFED BREAKER IS T, U METHOD OF <br />UTILITY INTERCONNECTION, BREAKER SHALL NOT <br />READ LINE AND LOAD. <br />CONDUITS TO BE PAINTED TO MATCH RESIDENCE <br />SMOKE AND CARBON MONOXIDE DETECTORS <br />WILL BE INSTALLED IF RESIDENCE DOES NOT <br />HAVE ANY <br />( Code references: CBC § 907.2.11.5 and CRC § R314) <br />( Code references: CBC § 420.4 and CRC § R315) <br />PROJECT INFORMATION <br />10 SUNPOWER <br />E20-327 <br />SOLAR MODULES <br />& <br />1 PVI-3.0-OUTD-S-US-A <br />INVERTER <br />ROOF MOUNT <br />COMP. SHINGLE <br />GENERAL ELECTRICAL NOTES <br />1. EQUIPMENT USED SHALL BE NEW, UNLESS <br />OTHERWISE NOTED. <br />2. EQUIPMENT USED SHALL BE UL LISTED, <br />UNLESS OTHERWISE NOTED. <br />3. EQUIPMENT SHALL BE INSTALLED PROVIDING <br />ADEQUATE PHYSICAL WORKING SPACE <br />AROUND THE EQUIPMENT AND SHALL COMPLY <br />WITH NEC. <br />4. COPPER CONDUCTORS SHALL BE USED AND <br />SHALL HAVE INSULATION RATING 600V, 90 C. <br />UNLESS OTHERWISE NOTED. <br />5. CONDUCTORS SHALL BE SIZED IN ACCORD- <br />ANCE TO NEC. CONDUCTORS AMPACITY <br />SHALL BE DE-RATED FOR TEMPERATURE <br />INCREASE, CONDUIT FILL AND VOLTAGE <br />DROP. <br />6. EXPOSED NON-CURRENT CARRYING METAL <br />PARTS SHALL BE GROUNDED AS PER NEC. <br />7. LOAD SIDE INTER-CONNECTION SHALL <br />COMPLY WITH NEC. <br />8. ALL ELECTRICAL CONDUIT TO BE METAL <br />CONDUIT. <br />SUM: MODULE WEIGHT <br />SUM: MOUNTS AND RAIL- WEIGHT (0.4 LB/SQ. FT.) <br />TOTAL INSTALLATION WEIGHT <br />TOTAL INSTALLATION AREA <br />DISTRIBUTION LOAD <br />PROPERTY AND CODE INF <br />PROPERTY OWNER: <br />MARISELA REYES <br />PROJECT SITE: <br />2309 W ST ANNE PL <br />SANTA ANA, CA 92704 <br />OCCUPANCY GROUP R-3 <br />TYPE OF CONSTRUCTION VB <br />STORIES 1 <br />SQ. FT.1241 SQ. FT. <br />410 LBS. <br />72.46 LBS. <br />482.46 LBS. <br />181.65 SQ. FT. <br />2.65 LBS / SQ. FT. <br />ONE SOURCE SHALL HAVE OVERCURRENT <br />DEVICES LOCATED SO AS TO PROVIDE <br />OVERCURRENT PROTECTION FROM ALL <br />SOURCES. <br />THE UTILITY-INTERACTIVE INVERTERS SHALL <br />AUTOMATICALLY DE-ENERGIZE ITS OUTPUT <br />TO THE CONNECTED ELECTRICAL PRODUCTION <br />AND DISTRIBUTION NETWORK UPON LOSS OF <br />VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN <br />THAT STATE UNTIL THE ELECTRICAL <br />PRODUCTION AND DISTRIBUTION NETWORK <br />VOLTAGE HAS BEEN RESTORED. <br />DUE TO THE FACT THAT PV MODULES ARE <br />ENERGIZED WHENEVER EXPOSED TO THE LIGHT, <br />PV CONTRACTOR SHALL DISABLE THE ARRAY <br />DURING INSTALLATION AND SERVICE BY SHORT <br />CIRCUITING, OPEN CIRCUITING, OR COVERING <br />THE ARRAY WITH OPAQUE COVERING. <br />ALL CONDUCTORS EXPOSED TO WEATHER SHALL <br />BE LISTED AND IDENTIFIED FOR USE IN DIRECT <br />SUNLIGHT. <br />THE MODULE CONDUCTORS MUST BE TYPE USE-2 <br />OR LISTED FOR PHOTOVOLTAIC WIRE.PV SYSTEM <br />CONNECTED ON THE LOAD SIDE OF THE SERVICE <br />DISCONNECTING MEANS OF THE OTHER <br />SOURCES AT ANY DISTRIBUTION EQUIPMENT ON <br />THE PREMISES SHALL MEET THE FOLLOWING: <br />- EACH SOURCE CONNECTION SHALL BE <br />MADE AT THE DEDICATED CIRCUIT BREAKER <br />OR FUSIBLE DISCONNECTING MEANS. <br />ALL NEC REQUIRED WARNING SIGNS, MARKINGS <br />AND LABELS SHALL BE POSTED ON EQUIPMENT <br />AND DISCONNECTS PRIOR TO ANY INSPECTIONS <br />TO BE PERFORMED BY THE BUILDING <br />DEPARTMENT INSPECTOR. <br />METALLIC RACEWAYS OR METALLIC <br />APPROVED <br />PLANNING DIVISIONritEETSHTA?LEDNURFEODRW'YGSMTHSOD MASTER I. D._2/1.1-=--tl.1.%.ENL.___L <br />FLEXIBLE, FINE-STRANDED CABLES SHALL BE <br />TERMINATED ONLY WITH TERMINALS, LUGS,G. P. L A <br />DEVICES, OR CONNECTOR THAT ARE IDENTIFIED -z-Li <br />AND LISTED FOR SUCH USE.PLANNER__zz_51-19_____ DATE__tid£·fCONNECTORS SHALL BE LATCHING OR LOCKING <br />TYPE. CONNECTORS THAT ARE READILY IRANSFERRED SY-ACCESSIBLE AND OPERATING AT OVER 30 VOLT <br />SHALL REQUIRE TOOL TO OPEN AND MARKEDDO DATEZTRRS:?%&20'ER.LOAD• OR "NOT FOR PLANNING INSPECTION R -.CQUIRED <br />EQUIPMENT GROUNDING CONDUCTOR FOR PV ROUGH- FINAL- NONE VMODULES SMALLER THAN 6AWG SHALL BE <br />PROTECTED FROM PHYSICAL DAMAGE BY A NAME - <br />RACEWAY OR CABLE ARMOR.--(714) - <br />tmf,Z-2mTUNGDRINCDOFNADUULCTTPORROFRC1TA!1PLA.NE FOR FUTURE RFV'RIA At Q::W12%':!c:fEUSN::'us#*T TO ITE;WS CHECKED-k;;B"23'NDITIONSTEMPERATURE AND CONDUIT FILL CORRECTED <br />CIRCUIT CONDUCTOR AMPACITY.O INTERIOR Ti ONLY <br />FINE-STRANDED CABLES USED FOR BATTERY <br />O ALL MATERIALS TO MATCH EXISTINGO NO EXTEREOE ALTERATIONS/MODIFICATIONSTERMINALS, DEVICES, AND CONNECTIONS <br />REQUIRE LUGS AND TERMINALS LISTED AND U SCREENliNG REQUIREDMARKED FOR THE USE. <br />O SUBMIT LANDSCAPE PLANS <br />CONDITIONS: €o (er pe· n /13 <br />DRAWN BY: - CHK.: - APV.:- <br />GSS <br />CLIENT INFORMATION <br />MARISELA <br />REYES <br />2309 W ST ANNE PL <br />SANTA ANA, CA <br />92704 <br />PHOTOVOLTAIC <br />SOLAR SYSTEM <br />SHEET TITLE <br />TITLE SHEET <br />0 <br />SHEET NUMBER rL / I rh ch 1/11
The URL can be used to link to this page
Your browser does not support the video tag.