My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3606 S Van Ness Ave - Plan
PBA
>
Building
>
ProjectDox
>
V
>
Van Ness Ave
>
3606 S Van Ness Ave
>
3606 S Van Ness Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2026 5:00:11 AM
Creation date
2/3/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
20187288
101125560
Full Address
3606 S Van Ness Ave
Street Number
3606
Street Direction
S
Street Name
Van Ness
Street Suffix
Ave
Text box
ID:
1
Creator:
Import Agent
Created:
2/3/2026 5:00 AM
Modified:
2/2/2026 10:05 AM
Text:
BLDG#: 101125560 ELEC# 20187288 APPROVALS: BLDG: KAhangian ELEC: MSmith
Stamp
ID:
1
Creator:
Import Agent
Created:
2/3/2026 5:00 AM
Modified:
2/2/2026 10:05 AM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
COVER SHEET <br />REVDATEDESCRIPTION <br />VERSION <br />10/13/2025INITIAL RELEASE <br />SHEET NAME <br />SHEET NUMBER <br />PV-0 <br />PROJECT NAME <br />36 <br />0 <br />6 <br /> <br />S <br /> <br />V <br />A <br />N <br /> <br />N <br />E <br />S <br />S <br /> <br />A <br />V <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />, <br /> <br />U <br />S <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />YE <br /> <br />Z <br />H <br />U <br />ME <br />T <br />E <br />R <br /> <br />N <br />O <br /># <br />: <br /> <br />3 <br />2 <br />2 <br />0 <br />1 <br />0 <br />1 <br />1 <br />5 <br />6 <br />6 <br />1 <br />AGE <br />AP <br />N <br /># <br />: <br /> <br />4 <br />1 <br />0 <br />1 <br />4 <br />1 <br />3 <br />6 <br />AH <br />J <br />: <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />I <br />T <br />Y <br />APTUS ENERGY <br />PHOTOVOLTAIC ROOF MOUNT SYSTEM <br /> 3606 S VAN NESS AVE, SANTA ANA, CA 92707, USA <br />GENERAL: <br />1. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF <br />PHOTOVOLTAIC SYSTEM. <br />2. 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL <br />BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY <br />RECOGNIZED TESTING LABORATORY ACCREDITED BY <br />THE UNITED STATES OCCUPATIONAL SAFETY HEALTH <br />ADMINISTRATION <br />3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS <br />PRIOR TO INITIATING CONSTRUCTION. <br />4. CONTRACTOR SHALL REVIEW ALL MANUFACTURER <br />INSTALLATION DOCUMENTS PRIOR TO INITIATING <br />CONSTRUCTION. <br />5. ALL EQUIPMENT AND ASSOCIATED CONNECTIONS, <br />ETC, <br />AND ALL ASSOCIATED WIRING AND <br />INTERCONNECTIONS SHALL BE INSTALLED ONLY BY <br />QUALIFIED PERSONNEL. <br />6. THE CONTRACTOR OR OWNER MUST PROVIDE ROOF <br />ACCESS (LADDER TO ROOF) FOR ALL THE REQUIRED <br />INSPECTIONS. LADDERS MUST BE OSHA APPROVED, <br />MINIMUM TYPE I WITH A 250LB. RATING, IN GOOD <br />CONDITION AND DESIGNED FOR ITS INTENDED USE. <br />7. CONTRACTOR SHALL VERIFY THAT THE ROOF <br />STRUCTURE WILL WITHSTAND THE ADDITIONAL LOADS. <br />8. LAG SCREWS SHALL PENETRATE A MINIMUM 2" INTO <br />SOLID SAWN STRUCTURAL MEMBERS AND SHALL NOT <br />EXCEED MANUFACTURER RECOMMENDATIONS FOR <br />FASTENERS INTO ENGINEERED STRUCTURAL <br />MEMBERS. <br />9. AN ACCESS POINT SHALL BE PROVIDED THAT DOES <br />NOT PLACE THE GROUND LADDER OVER OPENINGS <br />SUCH AS WINDOWS OR DOORS ARE LOCATED AT <br />STRONG POINTS OF BUILDING CONSTRUCTION AND IN <br />LOCATIONS WHERE THE ACCESS POINT DOES NOT <br />CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS <br />TREE LIMBS, WIRES, OR SIGNS. <br />10. WHERE DC CONDUCTORS ARE RUN INSIDE <br />BUILDING, <br />THEY SHALL BE CONTAINED IN A METAL RACEWAY; <br />THEY SHALL NOT BE INSTALLED WITHIN 10" OF THE <br />ROOF DECKING OR SHEATHING EXCEPT WHERE <br />COVERED BY THE PV MODULES AND EQUIPMENT. <br />11. PLUMBING AND MECHANICAL VENTS THROUGH THE <br />ROOF <br />SHALL NOT BE COVERED BY SOLAR MODULES- - NO <br />BUILDING, PLUMBING OR MECHANICAL VENTS TO BE <br />COVERED, CONSTRUCTED OR ROUTED AROUND SOLAR <br />MODULES. <br />12. ALL FIELD -INSTALLED JUNCTION, PULL AND OUTLET <br />BOXES LOCATED BEHIND MODULES SHALL BE <br />ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A <br />MODULE SECURED BY REMOVABLE FASTENERS. <br /> 15 MODULES-ROOF MOUNTED - 6.450 kWDC, 5.000 kWAC <br />2 VICINITY MAP <br />SCALE: NTSPV-0 <br />1 AERIAL PHOTO <br />SCALE: NTSPV-0 <br />DESIGN CRITERIA: <br />PV-0 COVER SHEET <br />PV-1 SITE PLAN <br />PV-2 ATTACHMENT PLAN <br />PV-3 FLOOR PLAN <br />PV-4 STANDOFF DETAILS <br />PV-5 SINGLE LINE DIAGRAM & CALCULATION <br />PV-6 THREE LINE DIAGRAM & CALCULATION <br />PV-7 STRING MAP <br />PV-8 PLACARDS & WARNING LABELS <br />PV-9 ELEVATION DETAILS <br />PV-10 MAIN PANEL PHOTO <br />PV-11 MODULES DATASHEET <br />PV-12 INVERTER DATASHEET <br />PV-13 BATTERY DATASHEET <br />PV-14 OPTIMIZERS DATASHEET <br />PV-15 ATTACHMENT DATASHEET <br />PV-16 RAIL DATASHEET <br />SHEET INDEX <br />CONSTRUCTION: SFR <br />ZONING: RESIDENTIAL <br />GROUND SNOW LOAD : 0 PSF <br />WIND SPEED : 95 MPH <br />WIND EXPOSURE: B <br />RISK CATEGORY: II <br />GOVERNING CODES: <br />2022 CALIFORNIA ELECTRIC CODE <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />OWNER: <br />NAME: YE ZHU <br />ADDRESS: 3606 S VAN NESS AVE, SANTA <br />ANA, CA 92707, USA <br />AUTHORITIES HAVING JURISDICTION: <br />BUILDING: SANTA ANA CITY <br />ZONING: SANTA ANA CITY <br />UTILITY : SOUTHERN CALIFORNIA EDISON (SCE) <br />SYSTEM SUMMARY: <br />(N)15 - SUNKET SKT430M10-108D5 (430W) SOLAR <br />MODULES <br />(N)01 - AMENSOLAR N3H-X5US HYBRID INVERTER <br />(N)15 - TS4-A-O OPTIMIZERS <br />(N) 1 - JUNCTION BOX <br />(N) 1 - 100A FUSED AC DISCONNECT <br />(N) 1 - SUNKET-ESS LFP 16kWh BATTERY <br />(N) 100A BACKUP LOAD PANEL <br />ELECTRICAL: <br />1. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM <br />CONTINUOUS CURRENT OUTPUT AT 25°C AND <br />MAXIMUM VOLTAGE AT 600V; WIRE SHALL BE WET <br />RATED AT 90°C. <br />2. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON <br />THE ROOF WILL BE USE 2 OR PV-TYPE WIRE. <br />3. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE <br />IDENTIFIED AND GROUPED. THE MEANS OF <br />IDENTIFICATION SHALL BE PERMITTED BY SEPARATE <br />COLOR-CODING, MARKING TAPE, TAGGING OR OTHER <br />APPROVED MEANS. <br />4. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL <br />BE RAIN-TIGHT AND APPROVED FOR USE IN WET <br />LOCATIONS. <br />5. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE <br />BONDED AND ELECTRICALLY CONTINUOUS. <br />6. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND <br />CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL <br />SIZE THEM ACCORDING TO APPLICABLE CODES. <br />7. REMOVAL OF A UTILITY-INTERACTIVE INVERTER OR <br />OTHER EQUIPMENT SHALL NOT DISCONNECT THE <br />BUILDING CONNECTION BETWEEN THE GROUNDING <br />ELECTRODE CONDUCTOR AND THE PV SOURCE <br />AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. <br />8. FOR GROUNDED SYSTEMS, THE PHOTOVOLTAIC <br />SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED <br />WITH A GROUND-FAULT PROTECTION DEVICE OR <br />SYSTEM THAT DETECTS A GROUND FAULT, INDICATES <br />THAT FAULT HAS OCCURED AND AUTOMATICALLY <br />DISCONNECTS ALL CONDUCTORS OR CAUSES THE <br />INVERTER TO AUTOMATICALLY CEASE SUPPLYING <br />POWER TO OUTPUT CIRCUITS. <br />9. FOR UNGROUNDED SYSTEMS, THE INVERTER IS EQUIPPED <br />WITH GROUND FAULT PROTECTION AND A GFI FUSE <br />PORT FOR GROUND FAULT INDICATION. <br />10. PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL <br />OR BARE COPPER GEC/GEC PER THE MODULE <br />MANUFACTURER'S LISTED INSTRUCTION SHEET. <br />11. PV MODULE RACKING RAIL SHALL BE BONDED TO BARE <br />COPPER GEC VIA WEEB LUG, ILSCO GBL-4DBT LAY-IN <br />LUG, OR EQUIVALENT LISTED LUG. <br />12. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 <br />COMPLIANT. <br />13. RACKING AND BONDING SYSTEM TO BE UL2703 RATED. <br />14. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR <br />WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS <br />AS BUS BARS WITHIN LISTED EQUIPMENT. <br />15. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY <br />INTERCONNECTION, THE BREAKERS SHALL NOT READ <br />"LINE AND LOAD". <br />16. WHEN APPLYING THE 120% RULE, THE SOLAR BREAKER <br />TO BE POSITIONED AT THE OPPOSITE END OF THE BUS <br />BAR FROM THE MAIN BREAKER. <br />17. THE WORKING CLEARANCE AROUND THE EXISTING <br />ELECTRICAL EQUIPMENT AS WELL AS THE NEW <br />ELECTRICAL EQUIPMENT WILL BE MAINTAINED. <br />Signed-12/08/2025 <br />EXP. 09/30/2026
The URL can be used to link to this page
Your browser does not support the video tag.