Laserfiche WebLink
REVDATEDESCRIPTION <br />VERSION <br />10/13/2025INITIAL RELEASE <br />SHEET NAME <br />SHEET NUMBER <br />PROJECT NAME <br />36 <br />0 <br />6 <br /> <br />S <br /> <br />V <br />A <br />N <br /> <br />N <br />E <br />S <br />S <br /> <br />A <br />V <br />E <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />, <br /> <br />U <br />S <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />YE <br /> <br />Z <br />H <br />U <br />ME <br />T <br />E <br />R <br /> <br />N <br />O <br /># <br />: <br /> <br />32 <br />2 <br />0 <br />1 <br />0 <br />1 <br />1 <br />5 <br />6 <br />6 <br />1 <br />AGE <br />AP <br />N <br /># <br />: <br /> <br />41 <br />0 <br />1 <br />4 <br />1 <br />3 <br />6 <br />AH <br />J <br />: <br /> <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />I <br />T <br />Y <br />APTUS ENERGY <br />BATTERY MOUTING <br />PLAN <br />SUNKET-ESS LFP <br />16kWh BATTERY <br />FLOOR-MOUNTED SUNKET-ESS LFP 16 KWH <br />BATTERY SHALL BE SECURED AT THE TOP USING <br />MANUFACTURER-SUPPLIED L-BRACKETS. <br />BRACKETS SHALL BE ANCHORED TO A <br />STRUCTURAL WALL WITH (2) M6 EXPANSION <br />ANCHORS INTO CONCRETE/MASONRY OR (2) 1/4″ <br />LAG BOLTS INTO WOOD STUDS, MINIMUM 70 MM <br />EMBEDMENT. ATTACHMENT SERVES AS ANTI-TIP <br />RESTRAINT ONLY; THE FLOOR SUPPORTS THE <br />FULL BATTERY WEIGHT. ANCHORS SHALL BE <br />INSTALLED INTO LOAD-BEARING CONSTRUCTION <br />ONLY (NO DRYWALL). <br />90 <br />0 <br />m <br />m <br />530mm <br />300mm <br />300mm <br />CLEARANCES: MAINTAIN A MINIMUM 300MM (12") <br />CLEARANCE ON ALL SIDES AND ABOVE THE UNIT <br />FOR VENTILATION AND EMERGENCY ACCESS. <br />ENSURE THE UNIT IS MOUNTED ON A <br />NON-FLAMMABLE SUBSTRATE TO MEET FIRE <br />SAFETY REQUIREMENTS. <br />70 <br />m <br />m <br />70 <br />m <br />m <br />BASE ANCHORING: SECURE THE BATTERY BASE <br />TO THE FLOOR USING (4) M6 EXPANSION BOLTS <br />DRILLED TO A MINIMUM DEPTH OF 70MM. BOLTS <br />MUST BE TORQUED TO 6 NM TO PREVENT <br />LATERAL DISPLACEMENT. <br />SUNKET-ESS LFP 16kWh BATTERY <br />WEIGHT - 120KG <br />DIMENSIONS (WIDTH X HEIGHT X DEPTH) <br />-530 X 900 X 245mm <br />THE UNIT SHALL BE INSTALLED ON <br />A LEVEL, NON-COMBUSTIBLE <br />CONCRETE SURFACE. THE STATIC <br />FLOOR LOAD IS APPROXIMATELY <br />265 LBS; VERIFY THE SLAB IS <br />CAPABLE OF SUPPORTING THIS <br />CONCENTRATED LOAD PER LOCAL <br />BUILDING CODES. <br />NOTE: BATTERY IS FLOOR-MOUNTED WITH WEIGHT SUPPORTED BY <br />CONCRETE SLAB. TOP WALL ATTACHMENT PROVIDED AS AN ANTI-TIP <br />RESTRAINT ONLY. L-BRACKETS ANCHORED TO BUILDING STRUCTURE <br />USING (2) MINIMUM 3/8" MECHANICAL ANCHORS (OR STRUCTURAL <br />SCREWS INTO STUDS), INSTALLED PER MANUFACTURER <br />SPECIFICATIONS AND LOCAL CODE REQUIREMENTS. <br />PV-10.1